Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (98)
cro4a1 a�0;) RECEIVED JUN 7 2018 CITY OF TIGARD BUILDII4°P "1IVIP!ON OREGON Submittal Date: May 9, 2018 Customer: Wolcott Project Name: James Templeton ES Engineer: PAE Location: Tigard OR Spec Section: - Johnson Barrow respectfully submits the following equipment for review: LG Building Management System Install General Notes: • This submittal is for approval. Approval is required in order for equipment to be released for fabrication Engineered Control Drawings included after approved Equipment Submittals Submitted By: Rudy Caffall Scott Bissell Johnson Barrow Oregon Johnson Barrow Oregon Direct/Cell: 503-260-0439 Direct/Cell: 206-637-4151 Email: RudyC@JBarrow.com Email:SBissell@jbarrow.com Sign Date Approved as Noted Approved with Comments Revise and Re-submit 735 SW 20 " Place 230 , Portland , OR 97205 PHONE (971) 717-7123 f f 11 JB.4 OREGON Submittal Contents Scope of Offer and Clarifications 3 Global/Supervisory Controller for System 4 Air Handler Unit Controller 15 Air Handler Temperature Sensors 25 Relays 28 Controls Enclosure 31 24VAC Transformer 33 • 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 JB4 OREGON Submittal Scope of Offer and Clarifications Scope of Supply: • Controls material submittals and shop drawings. • Project management of all controls responsibilities, including low voltage wiring. • Provision of BMS controllers and necessary controls components. • Programming and graphics development of HVAC systems: o AHU-101 with LG AHU Kit mechanical heating and cooling and DCV control. o Twelve (12) cafeteria heat pumps. ■ One master space temperature sensor. o One (1) split system. • Mechanical systems startup and commissioning support. • Owner training on BMS. • O&M documentation including manuals and as-built control drawings. Exclusions: UL listing, access panels, access, rigging, provision of VFDs, extended warranty, power metering, gas metering, water metering, cutting/patching/painting of surfaces, line voltage wiring, provision of fire smoke dampers, control or integration of fire smoke dampers, provision of control dampers. 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 JB4 OREGON Submittal Global/Supervisory Controller for System LG MuItiSITE VM3 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 , Job Name/Location: Tag#: Date: For: ❑ File ❑ Resubmit PO No.: ❑ Approval ❑ Other Architect: GC: Engr: Mech: Rep: (Company) (Project Manager) — PBACNBTR1A LG LG MuItiSITETM VM3 Life's Good Electrical: Supported Network Protocols: Power Supply 24VAC/24VDC/Optional wall power adapter BACnet® Power Consumption 24 VA LonWorks® 40 VA transformer recommended. MOdbus® Surrounding Conditions: Fox® Operating Temperature -4-140"F Storage Temperature -40-185°F Connectivity: Humidity 5-95%(non-condensing) LG V-Net Shipping and Vibration ASTM D4169,Assurance Level II 10/100 Ethernet MTBF 10+years Wireless Connectivity Unit Data: Wi-Fi: Dimensions 7.05"W x 4.33"H x 2.40"D IEEE802.11a/b/g/n Maximum Number of Devices 128(Expandable to 256) IEEE802.11n HT20 @ 2.4 GHz Maximum Number of Outdoor Units 16 per V-net IEEE802.11n HT20/HT40 @ 5 GHz USB Type A connector Configurable radio(Off,WAP,or Client)WPAPSK/WPA2PSK supported Removeable micro-SD card with 4GB flash total storage/2 GB user storage Communications Cabling Specifications(V-Net): Two(2)isolated V-Net communication ports Type 2-conductor,stranded,shielded copper cable/ Two(2) 10/100 MB Ethernet ports PVC or vinyl jacket Size AWG 18 x 2 Standard Features •Integrates All LG Multi VT"systems,Multi F systems,and select LG Maximum Length 3,280 ft(end to end) single zone systems with any building management system AWG-American Wire Gauge •MultiSITE VM3 standard licensing includes 5 devices(additional licensing available) Optional Accessories(sold separately): •Operates with Niagara 4,the latest version of the Niagara ❑ LON Module-ZHWLONWKO Framework®,for optimum performance o System view from any browser or device ❑ MultiSITE Supervisor-ZSWSUPDEM o Easier Integration Platform ❑ Adder pack for up to 128 additional LG VRF units for a total of o Enhanced Security 256 LG VRF Units-ZSWADD128 *Includes the LG Graphical User Interface ❑ 10 Device Upgrade-ZSWDVUP10 o Operation—On/Off o Mode—Auto/Cool/Dry/Heat/Fan Only ❑ 25 Device Upgrade ZSWDVUP25 o Fan Speed—Auto/Low/Med/High/Power ❑ Wall Power Adapter-ZHWPWADTR o Louver Swing o Two Setpoint Auto-Changeover o Two Setpoint Setback o Speed,Controller Lock,and Louver Swing o Temperature Setpoint Range Limit o Remote Controller Lock(All,Setpoint,Mode,Fan Speed) AsHIE •Powered by •Enterprise-scale control system B fl � diagara •On-board wireless capabilityRAMEwoRk LonWorks® is a trademark of Echelon Notes: Must follow installation instructions in the applicable LG installation manual. Available may functions featuresdiffer based on the connected system. / For continual product development,LG reserves the right to change specifications without notice. BACnet®is a trademark of ASHRAE. ©LG Electronics U.S.A.,Inc.,Englewood Cliffs,NJ.All rights reserved."LG Life's Good"is a registered trademark of LG Corp./www.Ighvac.com SB_MultiSITE_VM3_PBACNBTR1A_03_17 Page 1 of 10 , Job Name/Location: PBACNBTR1A0 Tag#: LG MuItiSITETM VM3 LG Date: Life's Good PO No.: 2.40" 2.19" 6.74" ► 0.34" � A 11 IIDI 0h _ ____._ _ .165" � �, 1 Dia 1.77" '' 4.33" 3.31" 3.31 -. 1 4.33" I4."."4\iiiiiimmi a F rpm . k6.38" . --►1 2.07" 1+ Unit:inch _ — 7.05". .-- 2.41° Compatible with (DlN43880) enclosures Suitable for mounting to a panel or to an EN50022 standard 35mm rail — . ' " •. i - \ / .00UA SOCK)a IOU A IOU a,CEN A CEN B 12V Cr-.E7 ‘ / RSAfI� / .M. _ in I gas / ;�., e+ 3H •\ 1 iiii/ ,� I , 1 / .. 1 ,,,.....i„ ....5,„4. al / .... ... ,_ _____ .�....-. ." .:" ' _ / -- ~ L ... ■IN■ I UN' s ni' L i ■NW- ■lla r 1111111111, NNS' Notes: Available functions/features may differ based on the connected system. For continual product development,LG reserves the right to change specifications without notice. ©LG Electronics U.S.A.,Inc.,Englewood Cliffs,NJ.All rights reserved."LG Life's Good"is a registered trademark of LG Corp./www.Ighvac.com SB_MuItiSITE_VM3_PBACNBTRSA_03_17 Page 2 of 10 Job Name/Location: PBACNBTR1A Tag#: LGLG MuItiSITETM VM3 Date: Life's Good PO No.: MuItiSITE VM3 BACnet® Object List Indoor Unit Monitor and Control Points Name Object Type Description On/Off BO Start Stop Command On/Off BI Start Stop Status Lock BO Lock Command Lock BI Lock Status FilterSign 81 Filter Sign FilterSign Release BV Filter Sign Reset OperationMode MO Operation Mode Command OperationMode MI Operation Mode Status Vane BO Vane Command Vane BI Vane Status FanSpeed MO Fan Speed Command FanSpeed MI Fan Speed Status RoomSetPoint AV Room Temperature Setpoint Setting RoomSetPoint Al Current Setpoint Status RoomTemp Al Room Temperature ERROR Al Malfunction Code PipelnTemp Al Pipe In Temperature PipeOutTemp Al Pipe Out Temperature UpperSetTempRange AV Upper Temperature Range Setting UpperSetTempRange AI Upper Temperature Range Status LowerSetTempRange AV Lower Temperature Range Setting LowerSetTempRange Al Lower Temperature Range Status FuncLock BO All Lock Command FuncLock 81 All Lock Status ModeLock BO Mode Lock Command ModeLock 81 Mode Lock Status FanLock BO Fan Lock Command FanLock BI Fan Lock Status TempLock BO Setpoint Temperature Lock Command TempLock BI Setpoint Temperature Lock Status Occ BO Occupancy Command Occ BI Occupancy Status CoolSetTemp AV Cooling Setpoint Setting CoolSetTemp Al Cooling Setpoint Status HeatSetTemp AV Heating Setpoint Setting HeatSetTemp Al Heating Setpoint Status CoolUpperTemp AV Cooling Upper Temperature Setting Indoor Unit M&C points continued on next page. Notes: Available functions/features may differ based on the connected system. For continual product development,LG reserves the right to change specifications without notice. ©LG Electronics U.S.A.,Inc.,Englewood Cliffs,NJ.All rights reserved."LA Life's Good"is a registered trademark of LA Corp./www.lghvac.com SB_MultiSITE_VM3_PBACNBTR1A_03_17 Page 3 of 10 Job Name/Location: PBACNBTR1A Tag#: LG MuItiSITETM VM3 L.G Date: Life's Good PO No.: MuItiSITE VM3 BACnet®Object List Indoor Unit Monitor and Control Points-continued Name Object Type Description CoolUpperTemp Al Cooling Upper Temperature Status HeatUpperTemp AV Heating Upper Temperature Setting HeatUpperTemp Al Heating Upper Temperature Status CoolLowerTemp AV Cooling Lower Temperature Setting CoolLowerTemp Al Cooling Lower Temperature Status HeatLowerTemp AV Heating Lower Temperature Setting HeatLowerTemp Al Heating Lower Temperature Status ThermoOn/Off MI Thermal On/Off Status AccumPoweriDU Al Accumulator Power Distribution Status CurrentPowerlDU Al Current Indoor Power Deadband Al Deadband Status 2SetAuto AO Enable 2Set Auto 2SetAuto Al 2Set Auto Status Override BI Override Status OccSensor BI Occupancy Sensor Status OccSensorinstalled BI Occupancy Sensor Installed 2SetFuncSupport BI 2Set Auto Support MuItiSITE VM3 BACnet'' Object List ERV Monitor and Control Points Name Object Type Description On/Off BO Start Stop Command On/Off 131 Start Stop Status Lock BO Lock Command Lock BI Lock Status FilterSign BI Filter Sign FilterSignRelease BV Filter Sign Reset Fan Speed MO Fan Speed Setting Fan Speed MI Fan Speed Status Malfunction Code Al Malfunction Code Operation Mode MO Operational Mode Operation Mode MI Operational Mode Status Heater BO Heater Command ^� Heater BI Heater Status Power Saving Status of ERV 80 Power Saving Status of ERV Command Power Saving Status of ERV 131 Power Saving Status of ERV Status Rapidity Status of ERV BO Rapidity Status of ERV Command Rapidity Status of ERV BI Rapidity Status of ERV Status RoomTemperature Al Room Temperature Notes: Available functions/features may differ based on the connected system. For continual product development,LG reserves the right to change specifications without notice. ®LG Electronics U.S.A.,Inc.,Englewood Cliffs,Ni.All rights reserved."LG Life's Good"is a registered trademark of LG Corp./www.lghvac.com SB_MultiSITE_VM3_PBACNBTR1A_03_17 Page 4 of 10 . Job Name/Location: PBACNBTR1A I� Tag#: � LG Date: LG MuItiSITELM VM3 Lifes Good PO No.: MuItiSITE VM3 BACnet® Object List ODU Monitor Only Points A/ Name Object Type Description RefrigerantType MI Type of Refrigerant ODUTypeUpperdigit Al HP, HR or Cool Only ODUTypelowerdigit Al Generation ERROR Al Malfunction Code SlaveUnitQuantity Al Slave ODU Quantity Unithaserror BI Error Status ODU_OperationMode MI Operational Mode of Outdoor Unit InvlCompCurrentFrequency Al Compressor_1 Current Frequency Inv2CompCurrentFrequency Al Compressor_2 Current Frequency CurrentFan1 Frequency Al Fan_1 Frequency CurrentFan2Frequency Al Fan_2 Frequency OutsideTemp Al Outdoor Air Temperature CurrentHighPressure Al High Pressure CurrentLowPressure Al Low Pressure SuctionTemp Al Suction Temperature InvldischargeTemp Al Inverter_1 Discharge Temperature Inv2dischargeTemp Al Inverter_2 Discharge Temperature LiquidpipeTemp Al Liquid Pipe Temperature HeatExchangetemp Al Heat Exchange Temperature HeatExchangeuppertemp Al Heater Exchange Upper Temperature HeatExchangelowertemp Al Heater Exchange Lower Temperature SubcoolpipeinTemp Al Sub Cool Pipe-In Temperature SubcoolpipeoutTemp Al Sub Cool Pipe-Out Temperature MainEEVIPosition Al Main EEV_1 Position MainEEV2Position Al Main EEV_2 Position SubcoolEEVPosition Al Sub Cooling EEV Position OILEQEEV Al Oil EEV VaporinjectionEEV1 Al Vapor Injection EEV_1 VaporinjectionEEV2 Al Vapor Injection EEV_2 Compquantity Al Compressor Quanity Inv1 Heater BI Inverter_1 Heater Inv2Heater BI Inverter_2 Heater InvlOilsensor BI Inverter_1 Oil Sensor Inv2Oilsensor BI Inverter_2 Oil Sensor InvlBackup BI Inverter_1 Backup Inv2Backup BI Inverter_2 Backup InvlCapacity Al Inverter_1 Capacity ODU Monitor Only points continued on next page. Notes: Available functions/features may differ based on the connected system. For continual product development,LG reserves the right to change specifications without notice. 0 LG Electronics U.S.A.,Inc.,Englewood Cliffs,N1.All rights reserved."LG Life's Good"is a registered trademark of LG Corp./www.lghvac.com SB_MultiSITE_VM3_PBACNBTR1A_03_17 Page 5 of 10 Job Name/Location: PBACNBTR1A Tag#: LG MuIt1SITETM VM3 LG Date: life's Good PO No.: MuItiSITE VM3 BACnet® Object List ODU Monitor Only Points -continued Name Object Type Description Inv2Capacity Al Inverter_2 Capacity IDUqauntity Al Indoor Unit Quantity ODUcapacityHP Al Outdoor Unit HP Capacity Operating Capacity Control given by 10 ControlStepEnhaceCapacity Al Module TargetCompPercent AV Operating Capacity Control TargetCompPercent Al Operating Capacity Status MuItiSITE VM3 BACnet®Object List Hydrokit Monitor and Control Points Name Object Type Description On/Off BO On/Off Command On/Off BI On/Off Command Status Lock BO Lock Command Lock BI Lock Status OperationMode MO Operational Mode Setting OperationMode MI Operational Mode Status Air/WaterSetPoint AO Room Temperature Setpoint Air/WaterSetPoint Al Room Temperature Setpoint Status HotwaterSetPoint AV Hot Water Setpoint HotwaterSetPoint Al Hot Water Setpoint Status ControlMode BO Control Mode Command ControlMode BI Control Mode Status HotwaterOnly BI Hot Water Only Status RoomTemp Al Room Temperature ERROR Al Malfunction Code HotwaterOperation BO Hot Water Operation Command HotwaterOperation BI Hot Water Operation Status WaterinTemp Al Water In Temperature WaterOutTemp Al Water Out Temperature HotwaterTankTemp Al Hot Water Tank Temperature SolarSourceTemp Al Solar Temperature SetPipeOutWaterTempCommand AV Supply Water Temperature Command SetPipeOutWaterTempStatus Al Supply Water Temperature Status Notes: Available functions/features may differ based on the connected system. For continual product development,LG reserves the right to change specifications without notice. 0 LG Electronics U.S.A.,Inc.,Englewood Cliffs,NJ.All rights reserved."LG Life's Good"is a registered trademark of LG Corp./www.lghvac.com SB_MultiSITE VM3_PBACNBTR1A_03_17 Page 6 of 10 Job Name/Location: PBACNBTR1A I Tag#: LG MuItiSITETM VM3 LG Date: Life's Good PO No.: MuItiSITE VM3 LonWorks° Network Variables List Indoor Unit Monitor and Control Points Name Network Variable Description nviLock SNVT_switch Start Stop Command nvoLock SNVT_switch Start Stop Status nviFilterSign SNVT_switch Filter Sign nvoFilterSignRelease SNVT_switch Filter Sign Reset nviMode SNVT_hvac_mode Operation Mode Command nvoMode SNVT_hvac_mode Operation Mode Status nviSwing SNVT_switch Vane Command nvoSwing SNVT_switch Vane Status nviFanSpeed SNVT_switch Fan Speed Command nvoFanSpeed SNVT_switch Fan Speed Status nviSetPoint SNVT_temp_p Room Temperature Setpoint Setting nvoSetPoint SNVT_temp_p Current Setpoint Status nvoRoomTemp SNVT_temp_p Room Temperature nvoERROR SNVT_hvac_status Malfunction Code nvoPipelnTemp SNVT_temp_p Pipe In Temperature nvoPipeOutTemp SNVT_temp_p Pipe Out Temperature nviUpperSetTempRange SNVT_temp_p Upper Temperature Range Setting nvoUpperSetTempRange SNVT_temp_p Upper Temperature Range Status nviLowerSetTempRange SNVT_temp_p Lower Temperature Range Setting nvoLowerSetTempRange SNVT_temp_p Lower Temperature Range Status nviFuncLock SNVT_switch All Lock Command nvoFuncLock SNVT_switch All Lock Status nviModeLock SNVT switch Mode Lock Command nvoModeLock SNVT__switch Mode Lock Status nviFanLock SNVT switch Fan Lock Command nvoFanLock SNVT switch Fan Lock Status nviTempLock SNVT_switch Setpoint Temperature Lock Command nvoTempLock SNVT_switch Setpoint Temperature Lock Status nviOcc SNVT_switch Occupancy Command nvoOcc SNVT_switch Occupancy Status nviCoolSetTemp SNVT_temp_p Cooling Setpoint Setting nvoCoolSetTemp SNVT_temp_p Cooling Setpoint Status nviHeatSetTemp SNVT_temp_p Heating Setpoint Setting nvoHeatSetTemp SNVT_temp_p Heating Setpoint Status nviCoolUpperTemp SNVT_temp_p Cooling Upper Temperature Setting nvoCoolUpperTemp , SNVT_temp_p Cooling Upper Temperature Status nviHeatUpperTemp SNVT_temp_p Heating Upper Temperature Setting nvoHeatUpperTemp SNVT_temp_p Heating Upper Temperature Status Indoor Unit M&C points continued on next page. Notes: Available functions/features may differ based on the connected system. For continual product development,LG reserves the right to change specifications without notice. ©LG Electronics U.S.A.,Inc.,Englewood Cliffs,NJ.All rights reserved."LG Life's Good"is a registered trademark of LG Corp./www.Ighvac.com SB_MultiSITE_VM3_PBACNBTR1A_03_17 Page 7 of 10 Job Name/Location: P BACN BTR1A Tag#: LG MuItiSITETM VM3 0 L. G Date: Life's Good PO No.: MuItiSITE VM3 LonWorks® Network Variables List Indoor Unit Monitor and Control Points -continued Name Network Variable Description nviCoolLowerlemp SNVT_temp_p Cooling Lower Temperature Setting nvoCoolLowerTemp SNVT_temp_p Cooling Lower Temperature Status nviHeatLowerTemp SNVT_temp_p Heating Lower Temperature Setting nvoHeatLowerTemp SNVT_temp_p Heating Lower Temperature Status nvoThermoOn/Off SNVT_switch Thermal On/Off Status nvoAccumPowerlDU SNVT_count_f Accumulator Power Distribution Status nvoCurrentPowerlDU SNVT_count_f Current Indoor Power nvoDeadband SNVT_temp_p Deadband Status nvi2SetAuto SNVT_switch Enable 2Set Auto nvo2SetAuto SNVT_switch 2Set Auto Status nvoOverride SNVT_switch Override Status nvoOccSensor SNVT_switch Occupancy Sensor Status nvoOccSensorinstalled SNVT_switch Occupancy Sensor Installed nvo2SetFuncSupport SNVT_switch 2Set Auto Support MuItiSITE VM3 LonWorks® Network Variables List ERV Monitor and Control Points Name Network Variable Description nviOperation SNVT_switch Start Stop Command nvoOperation SNVT_switch Start Stop Status nviLock SNVT_switch Lock Command nvoLock SNVT_switch Lock Status nviFilterSign SNVT_switch Filter Sign nvoFilterSignRetease SNVT_switch Filter Sign Reset nviFanSpeed SNVT_switch Fan Speed Setting nvoFanSpeed SNVT switch Fan Speed Status nvoERROR SNVT_hvac_status Malfunction Code nviMode SNVT hvac_mode Operational Mode nvoMode SNVT_hvac_mode Operational Mode Status nviHeater SNVT_switch Heater Command nvoHeater SNVT_switch Heater Status nviDrift SNVT_count Power Saving Status of ERV Command nvoDrift SNVT_count Power Saving Status of ERV Status nviQuick SNVT_switch Rapidity Status of ERV Command nvoQuick SNVT_switch Rapidity Status of ERV Status nvoRoomTemp SNVT_temp_p Room Temperature Notes: Available functions/features may differ based on the connected system. For continual product development,LG reserves the right to change specifications without notice. 0 LG Electronics U.S.A.,Inc.,Englewood Cliffs,NJ.All rights reserved."LG Life's Good"is a registered trademark of LG Corp./www.lghvac.com SB_MuItiSITE_VM3_PBACNBTR1A_03_17 Page 8 of 10 Job Name/Location: PBACNBTR1A Tag#: LLG MuItiSITETM VM3 Date: Life's Good PO No.: MuItiSITE VM3 LonWorks® Network Variables List ODU Monitor Only Points Name Network Variable Description nvoRefrigerantType SNVT_count_f Type of Refrigerant nvoODUTypeUpperdigit SNVT_count_f HP, HR or Cool Only nvoODUTypelowerdigit SNVT_countf Generation nvoERROR SNVT_hvac_mode Malfunction Code nvoSlaveUnitQuantity SNVT_count_f Slave ODU Quantity nvoUnithaserror SNVT_switch Error Status nvoODU_OperationMode SNVT_count_f Operational Mode of Outdoor Unit nvolnvlCompCurrentFrequency SNVT_count_f Compressor_1 Current Frequency nvalnv2CompCurrentFrequency SNVT_count_f Compressor 2 Current Frequency nvoCurrentFanl Frequency SNVT_count_f Fan_1 Frequency nvoCurrentFan2Frequency SNVT count_f Fan_2 Frequency nvoOutsideTemp SNVT_temp_p Outdoor Air Temperature nvoCurrentHighPressure SNVT_count f High Pressure nvoCurrentLowPressure SNVT_count_f Low Pressure nvoSuctionTemp SNVT_temp_p Suction Temperature nvolnvldischargeTemp SNVT_temp_p Inverter_1 Discharge Temperature nvolnv2dischargeTemp SNVT_temp_p Inverter_2 Discharge Temperature nvoLiquidpipeTemp SNVT_temp_p Liquid Pipe Temperature nvoHeatExchangetemp SNVT_temp_p Heat Exchange Temperature Heater Exchange Upper nvoHeatExchangeuppertemp SNVT_temp_p Temperature Heater Exchange Lower nvoHeatExchangelowertemp SNVT_temp_p Temperature nvoSubcoolpipeinTemp SNVT_temp_p Sub Cool Pipe-In Temperature nvoSubcoolpipeoutTemp SNVT_temp_p Sub Cool Pipe-Out Temperature nvoMainEEVlPosition SNVT_count_f Main EEV_1 Position nvoMainEEV2Position SNVT_count_f Main EEV_2 Position nvoSubcoolEEVPosition SNVT_count_f Sub Cooling EEV Position nvoOILEQEEV SNVT_count_f Oil EEV nvoVaporinjectionEEV1 SNVT_count_f Vapor Injection EEV_1 nvoVaporinjectionEEV2 SNVT_count_f Vapor Injection EEV_2 nvoCompquantity SNVT_count_f Compressor Quanity nvolnvlHeater SNVT_switch Inverter_1 Heater nvolnv2Heater SNVT_switch Inverter_2 Heater nvolnvlOilsensor SNVT_switch Inverter_1 Oil Sensor nvolnv2Oilsensor SNVT_switch Inverter_2 Oil Sensor nvolnvlBackup SNVT_switch Inverter_1 Backup ODU Monitor Only points continued on next page. Notes: Available functions/features may differ based on the connected system. For continual product development,LG reserves the right to change specifications without notice. ®LG Electronics U.SA.,Inc.,Englewood Cliffs,NJ.All rights reserved."LG Life's Good"is a registered trademark of LG Corp./www.lghvac.com SB_MultiSITE_VM3_PBACNBTR1A_03_17 Page 9 of 10 Job Name/Location: PBACNBTR1A Tag#: LG MuItiSITETM VM3 L_G Date: Life's Good PO No.: MuItiSITE VM3 LonWorks® Network Variables List ODU Monitor Only Points-continued Name Network Variable Description nvolnv2Backup SNVT_switch Inverter 2 Backup nvolnvl Capacity SNVT_count_f Inverter_l Capacity nvoinv2Capacity SNVT count f Inverter_2 Capacity nvolDUqauntity SNVT_count_f Indoor Unit Quantity nvoODUcapacityHP SNVT_count_f Outdoor Unit HP Capacity Operating Capacity Control given nvoControlStepEnhaceCapacity SNVT_count_f by 10 Module nviTargetCompPercent SNVT_count_f Operating Capacity Control nvoTargetCompPercent SNVT_count_f Operating Capacity Status MuItiSITE VM3 LonWorks® Network Variables List Hydrokit Monitor and Control Points Name Network Variable Description nviOperation SNVT_switch On/Off Command nvoOperation SNVT_switch On/Off Command Status nviLock SNVT_switch Lock Command nvoLock SNVT_switch Lock Status nviOperationMode SNVT_hvac_mode Operational Mode Setting nvoOperationMode SNVT_hvac_mode Operational Mode Status nviAirANaterSetPoint SNVT_temp_p Room Temperature Setpoint nvoAir/WaterSetPoint SNVT_temp_p Room Temperature Setpoint Status nviHotwaterSetPoint SNVT_temp_p Hot Water Setpoint nvoHotwaterSetPoint, SNVT_temp_p Hot Water Setpoint Status nviControlMode SNVT_switch Control Mode Command nvoControlMode SNVT_switch Control Mode Status nvoHotwaterOnly SNVT_switch Hot Water Only Status nvoRoomTemp SNVT temper Room Temperature nvoERROR SNVT_hvac_status Malfunction Code nviHotwaterOperation SNVT_switch Hot Water Operation Command nvoHotwaterOperation SNVT_switch Hot Water Operation Status nvoWaterinTemp SNVT_temp_p Water In Temperature nvoWaterOutTemp SNVT_temp_p Water Out Temperature nvoHotwaterTankTemp SNVT temp_p Hot Water Tank Temperature nvoSolarSourceTemp SNVT_temp_p Solar Temperature SetPipeOutWaterTempcommand SNVT temp_p Supply Water Temperature Command SetPipeOutWaterTempStatus SNVT_temp_p Supply Water Temperature Status Notes: Available functions/features may differ based on the connected system. For continual product development,LG reserves the right to change specifications without notice. ©LG Electronics U.S.A.,Inc.,Englewood Cliffs,Ni.All rights reserved."LG Life's Good"is a registered trademark of LG Corp./www.Ighvac.com SB MuItiSITE_VM3_PBACNBTR1A_03_17 Page 10 of 10 Ihje4 OREGON Submittal Air Handler Unit Controller Taco Clarity 3 735 SW 20 " Place 230 , Portland , OR 97205 PHONE (971) 717-7123 Clarity3 CLAR-FPC Series alirawC0 BACnet General Purpose Controllers (B-AAC) ComfortiSo/utionse A Taco Family Company DESCRIPTION Canty3 TMmnI Taco Clarity3 CLAR-FPC series controllers are designed to ClU`impi `""°' control building systems and HVAC equipment.The integrated 11111111 alarming,scheduling,and trending enable these BACnet clarity Advanced Application Controllers to be powerful edge devices for the modern smart building ecosystem. ie The controllers feature simple,menu-driven setup choices using a Clarity3 CLAR-NS series digital sensor,which can be installed permanently as the room sensor or used temporarily _ as a technician's service tool. 0 CE C �L O US LISTED MADE IN USA C 1��. Alternately,quick configuration of controller properties can APPLICATIONS be done using NFC(Near Field Communication)from a smart phone,tablet,or computer(using o Vison Lite app)while the Can be used with the following types of equipment: controller is unpowered. I fie Cil lel ilet-enabled CLAR-t i' ;-iP c . also be configured by connecting an HTML5-compatible web • Air handling units browser to the built-in configuration web pages. • Boilers • Chillers To meet the most demanding building automation custom • Chilled beams requirements,these controllers are also fully programmable. • Cooling towers Custom configuration and programming,with wizards for • Fan coil units application programming selection/configuration,are enabled • Heat pump units by Taco Vision software. • Pumps • Roof top units • Unit ventilators • Other HVAC and building automation system equipment NOTE: Applications generally require custom programming. (See also Sample Installation on page 5.) MODELS FEATURES APPLICATIONS INPUTS* OUTPUTS* MODEL Real Time Ethernet MS/TP Clock(RTC) Port Port AHU,chillers, 10 total: 8 universal: boilers,cooling • 2 analog(temperature sensor • Software configur- ✓ CLAR-FPC-C towers,pumps, port) able as analog or lighting, FCU, HPU, • 8 universal inputs(software binary RTU,unit ventila- configurable as analog,binary, • Override boards give to, CLAR-FPC-CIP tors,other HVAC or accumulator on terminals) additional options** *Up to four CLAR-EM-FPC I/O expansion modules can be used with BAC-5900 series controllers to provide up to(internal and external) 42 inputs and 40 outputs. ** series output override board series provide(triac,NC/NO relays,4-20 mA,adjustable 0-10 VDC)options for devices that cannot be powered from a standard universal output.The boards can also be used with the CLAR-EM-FPC. Taco, Inc., 1160 Cranston Street, Cranston, RI 02920 / 401-942-8000 / Fax 401-942-2360 / www.tacocomfort.com SPECIFICATIONS A -- E Output Override Room Output Power/Status $®® m® ®® ®®$ $$ 11111,_ Board Slots&Cover Sensor Port Terminals LED (7.,, ____j •Il ° \ (Optional) �f.� :444.4s MS/TP �ii �'- Status LED, ''.' ''. Power + Network `�- �►� Terminals 0 '�+ B C F Bulbs,EOL •\ ,� li Switch,and \A ' Terminals \\'4_ y, wi NFC Ill Target \En 0 . 2 -1 IS 1144-4744 Obi IN D (Optional) Input EIO Terminals Status Ethernet Ports Terminals and EOL Switch LED DIMENSIONS A 6.750 inches 171 mm B 5.500 inches 140 mm Outputs,Universal (8 on Terminal Blocks) C 5.000 inches 127 mm Universal outputs Configurable as an analog (0 to 12 D 6.000 inches 152 mm VDC) or binary object(0 or 12 VDC, E 2.012 inches 51 mm on/off);alternately,an output over- F 6.300 inches 160 mm ride board is installed for devices that cannot be powered from a standard TERMINAL COLOR CODE universal output Black 24 VAC/VDC Power Power/protection Each short-circuit protected universal Gray MS/TP and CAN Communications output capable of driving up to 100 mA(at 0-12 VDC)or 300 mA total for Green Inputs and Outputs I all outputs Resolution 12-bit digital-to-analog conversion Inputs and Outputs 9 9 Wire size 12-24 AWG,copper,in removable Inputs, Universal (8 on Terminal Blocks) screw terminal blocks Universal inputs Configurable as analog,binary,or accumulator objects Communications Termination 1K and 10K ohm sensors,0-12 VDC, Auxiliary One serial port with mini Type B con- or 0-20 mA(without need for an nector(reserved for future use) external resistor) Expansion(E10) One CAN serial bus connection Resolution 16-bit analog-to-digital conversion (terminal block)for daisy-chaining Protection Overvoltage protection(24 VAC, I/O expansion modules up to 200 feet continuous) (61 meters)from the controller via standard shielded twisted-pair wire Wire size 12-24 AWG,copper,in removable screw terminal blocks Ethernet(optional) On "E"model only,two 10/100BaseT Ethernet connectors for BACnet IP, Input, Dedicated Room Sensor Port Foreign Device,and Ethernet 802.3 (ISO 8802-3);segmentation support- Connector Modular connector for Clarity' CLAR- ed;up to 328 ft(100 m) between series NetSensors(digital wall controllers (using T568B Category 5 sensors)or C.L4:' a analog tempera- or better cable) ture sensors Cable Uses standard Ethernet patch cable up to 150 feet (45 meters) 2 MS/TP(optional) One EIA-485 port(removable terminal Configuring, Programming, and Designing block)for BACnet MS/TP,operat- ing at 9.6, 19.2,38.4, 57.6,or 76.8 SETUP PROCESS kilobaud;max. length of up to 4,000 feet(1,200 meters) of 18 AWG shield- Programming TOOL ed twisted-pair,no more than 51 pf/ft Configuration (Control Basic) (167 pf/m);use repeaters for longer distances ✓ Taco Clarity'NetSensor NFC NFC(Near Field Communication) up Taco Vision Lite(NFC)app* to 1 inch (2.54 cm)from the top of the enclosure V V Taco Vision software Room sensor Modular connector for LAR-NS se- ries digital wall sensors or CLAR-RS *Near Field Communication via enabled smart phone or tablet analog temperature sensors running the Taco Vision L app. Configurability Hardware Features OBJECTS* MAX': 1 # Processor, Memory,and Clock Inputs and Outputs Processor 32-bit ARM®Cortex-M4 Memory Programs and configuration parame- Analog,binary,or accumulator input 42 ters are stored in nonvolatile memory; Analog or binary output 40 auto restart on power failure Values RTC Real time clock with(capacitor) pow- er backup for 72 hours("C"model Analog value 120 only)for network time synchroniza- Binary value 80 tion or full stand-alone operation Multi-state value 40 Indicators and Isolation Program and Control LED indicators Power/status,MS/TP and CAN com- Program (Control Basic) 10 munication,and Ethernet status PID loop 10 MS/TP bulbs One network bulb assembly indicates reversed polarity and isolates circuit Schedules Switches EOL(end of line)for MS/TP and CAN Schedule 2 bus Calendar 1 Logs Installation Trend log 20 — Power Trend log multiple(must be created) 4(default 0) Supply voltage 24 VAC (50/60 Hz)or 24 VDC;-15%, Alarms and Events +20%;Class 2 only;non-supervised Notification class 5 (all circuits,including supply voltage, Event enrollment 40 are power limited circuits) Required power 14 VA,plus external loads *Configuration allows creation and deletion of objects(maxi- mum number of objects shown).The number and configuration Wire size 12-24 AWG,copper,in a removable of default objects depends on the selected application. For lists screw terminal block of default objects,see the KMC Conquest Controller Application C-.'.See also the PIC statement for all supported BACnet objects. 3 Enclosure and Mounting ACCESSORIES Weight 14 ounces(0.4 kg) ACC-7700 Series Output override(triac,NC/NO relays, Case material flame-retardant plastic 4-20 mA)board series for devices Mounting Direct mounting to panels or DIN rails that cannot be powered from a stand ard universal output Environmental Limits CLAR-BACROUTER Single-port BACnet router Operating 32 to 120° F(0 to 49°C) CLAR-NS Series Digital NetSensor room temperature Shipping —40 to 160° F(-40 to 71°C) sensors for viewing and configuration and optional humidity,occupancy, Humidity 0 to 95%relative humidity and CO2 sensing (non-condensing) CLAR-RS-W Series Analog temperature sensors Warrant Protocol, and Approvals ACC-RFTERMBLOCKCLAR Controller replacement parts kit with Y, PP terminal blocks(1 gray,1 black,2 green 3-terminal,4 green 4-terminal, Warranty 2 green 5-terminal,2 green 6-termi- 5yearsmfg. date code) nal)and DIN clips (2 small for router Limited Warranty (from 9 and 1 large for controllers) g t ) BACnet Protocol CLAR-EM-FPC Input/output expansion module,8 x 8 Standard Meets or exceeds the specifications in ANSI/ASHRAE BACnet Standard 135-2010 for Advanced Application Controllers Type BTL-certified as a B-AAC controller type CAN (External Inputs Outputs) Protocol CAN CAN (Controller Area Network)bus on(EIO)terminals Regulatory Approvals UL UL 916 Energy Management Equip- ment listed BTL BACnet Testing Laboratory listed as Advanced Application Controller (B-AAC) CE CE compliant RoHS 2 RoHS 2 compliant(pending) FCC FCC Class A, Part 15,Subpart B and complies with Canadian ICES-003 Class A* *This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)This device may not cause harmful interference,and (2)this device must accept any interference received,including interference that may cause undesired operation. (NFC operation meets FCC compliance while the controller is in an unpowered state.) 4 SAMPLE INSTALLATION OPIII „ Communication with Other Network Devices and Remote Monitoring Configuration 1111 via NFC-Enabled Smart Phone and I CL.AR-FPC-C Vision Lite App \\ Up to 8 Inputs(to —..,_ terminal blocks) 11111111 Up to 8 Universal / mil Clarity' Outputs(plus,ACC-770x NetSensor Output Override Board CO2 - (to modular options for 4-20 mA, (lC connector) triac,NO/NC relays, or 0-10 VDC with 000` a` djustable override) 0 3ulnlintlul Quick(temporary)Network Optional Access Through Computer CLAR-EM-FPC Data Port I/O Expansion Modules r; 'milli i,,,, Other Sensors NOTE: For more information about installation and operation, see the I_.=.R-`PC Series Controller Installation Guide. © 2018 Taco, Inc. Specifications and design are subject to change without notice xxxxxxxxxA "al ac® Clarity3 NetSensors Co/Wortt/Solutions® NS 100/200 Series Digital Room Sensors A Taco Family Company DESCRIPTION Taco100/200 series NetSensors are wall-mounted digital space temperature sensors designed for use with Taco Clarity3 series controllers. Key features include the following: 111 • Up to four sensors in a single package minimizes labor,wir- ing,and wall space,while optional humidity, motion,and CO2 C E sensors allow expanded energy-efficient control of humidity, temperature setback, lighting,and ventilation. • A user-friendly three-button integrated operator interface provides system viewing and adjusting for occupants. • The upper(default) LCD display shows room temperature and setpoints.A lower(default)display shows local time and can be enabled to show(dependent on sensors and controller 0°S LISTED configuration) %relative humidity,CO2 ppm,and outside air r7C® temperature(°F or°C) in rotation. Both displays can be con- figured to show any controller default or calculated analog or binary values (such as airflow or energy consumption),and APPLICATIONS multiple values can show in rotation. • It allows up to two separate passwords for adjusting set- Temperature sensing to Clarity3 series controllers for such points and configuring/commissioning/balancing. applications as RTUs, HPUs, FCUs, AHUs, VAV terminal units, • Up to 32 additional command points can be configured for and unit ventilators. user control and monitoring of a connected system (e.g., lighting,fan,or AHU control)from the display Optional humidity sensing is for dehumidification and/or • It connects to a controller via a modular jack connection sequences. using standard Ethernet patch cables. • It installs permanently as a room sensor or temporarily as Optional motion sensing enhances occupancy-based control a service tool;as a service tool,it commissions controllers for lighting control,temperature setback,or self learning without software,configures communication and application schedules. settings,and balances VAV air flow. Optional CO2 sensing enables demand-control ventilation • An HPO-9001 NetSensor®distribution module allows up to ; ,;r=for optimizing ventilation and energy efficiency. eight 100/200 series NetSensors to be linked to one control- ler or allows one STE-6010/6014/6017 analog temperature sensor to be connected with up to seven NetSensors. MODELS APPLICATIONS:TEMPERATURE CONTROL PLUS... INTEGRATED SENSORS* MODEL** Temp. Humidity Motion CO2 Temperature control only CLAR-NS-101 Humidity control for dehumidification/humidification / CLAR-NS-201 Enhanced occupancy-based control(lighting/setback/self-learning) I/ CLAR-NS-102 Humidity and occupancy control ✓ `/ CLAR-NS-202 DCV(Demand-Control Ventilation) / CLAR-NS-111 Humidity and ventilation control / V CLAR-NS-211 Occupancy and ventilation control / I/ CLAR-NS-112 Humidity,occupancy,and ventilation control t,/ `/ `/ CLAR-NS-212 *All units have a temperature sensor(standard).See above for additional sensor options. Document#601-005 Effective Date: February 1, 2018 SPECIFICATIONS A 1 1_IA iii E c ' ' ID l'-> . $ t'} () j->; 1 D 1x151 leek,t'1L1 ovk � 0 _ C �pCOOLHEAT SE�TP��OINT I{elf, j/M�!1)Fyl 1 ,S6 _Il gM: B gm 7-----'---- ------- DIMENSIONS , V ' A 3.500 inches 89 mm B 5.124 inches 130 mm II0•,-,•, •05-,5" C 1.125 inches 29 mm o� s.-•., D 1.336 inches 34 mm Sensors Temperature Sensor(without humidity sensor) Operating limits 34°to 122° F(1.1 to 50° C) Sensor type Thermistor, 10K Type II Shipping limits -22°to 140° F(-30°C to 60° C) Accuracy ±0.36° F(±0.2° C) CO2 range 0 to 2000 ppm,0-1% Resistance 10,000 ohms at 77° F(25° C) Accuracy ±50 ppm,±3%of reading* Operating range 48 to 96° F(8.8 to 35.5° C) Non-linearity < 1%of full scale Calibration Automatic calibration built-in* Temperature Sensor(with humidity sensor) Pressure dependence 0.13%of reading per mm Hg Sensor type CMOS Oper. pressure range 950 to 1050 bar Accuracy ±0.9° F(±0.5°C)offset from Warm-up time 10 seconds 40 to 104° F(4.4 to 40° C) Operating range 36 to 120° F(2.2 to 48.8° C) *NOTE: The CO2 sensor uses a self-calibration technique designed to be used in applications where CO2 Humidity Sensor(optional) concentrations will periodically drop to outside ambient conditions(approximately 400 ppm),typically Sensor type CMOS during unoccupied periods.The sensor will typically Range 0 to 100% RH reach its operational accuracyafter 25 hours of 9 Accuracy @ 25°C ±2%RH (10 to 90% RH) continuous operation if it was exposed to ambient reference levels of air at 400±10 ppm CO2.The sensor Response time Less than or equal to 4 seconds will maintain accuracy specifications if it is exposed to the reference value at least four times in 21 days. CO2 Sensor(optional) Detector type Non Dispersive Infrared(NDIR),with Motion Sensor(optional) solid-state source and detector Detector type Passive infrared Sample method Diffusion Range and Coverage 33 feet(10 meters)—see(Optional) Rated life 15 years minimum Motion Sensing Coverage on page 3 2 (Optional)Motion Sensing Coverage Enclosure and Mounting 70rt " 10rn Y Weight 2.8 ounces(80 grams) 46.5° Case material Flame-retardant plastic Mounting Surface mount directly to any flat Agt surface or to a 2 x 4 inch or 4 x 4 inch electrical box(mounting on a 4 x 4 ppP, box or a horizontal 2 x 4 box re irequ s •► —_ °. i �_.�,� os an HMO-10000/10000W mounting backplate) `\V4 \44%;-7; Environmental Limits 34° 125° ° C)* \ Lt,\44\ Operating to 125 F(1.1 to 51.6° Shipping -40°to 140° F(-40°C to 60° C)* Pp 9 6 YOm 1 55° 10m � Humidity 0 to 95%relative humidity Top View Side View non condensing *NOTE: For models with the optional CO2 sensor,see the reduced range in the operating and shipping limits in Installation CO.Sensot (optional)on page 2. Connections Warranty, Protocol, and Approvals Connector type Eight-wire RJ-45 modular jack Warranty Cable type Standard T568B(Category 5 or bet- ter) Ethernet patch cable up to 150 Taco Limited Warranty 5 years(from mfg.date code) feet(45 meters) Power Supplied by connected controller Controller Protocol Compatibility BACnet Clarity Controllers Display Regulatory Approvals Type Multifunctional LCD with backlight Size 1.88 x 1.25 inches(48 x 32 mm) UL UL 916 Energy Management Equip- ment listed Icons Language-independent symbols for CE CE compliant mode and operating status Features Four-character upper display(with RoHS 2 RoHS 2 compliant(pending) units of°F,°C,CFM, LPS,OVR,COOL, FCC FCC Class A,Part 15,Subpart B and HEAT,and SETPOINT)for room complies with Canadian ICES-003 temperature and setpoints(see the Class A* drawing under Specifications on *This device complies with part 15 of the FCC Rules. Operation page 2) is subject to the following two conditions: (1)This device may Icons showing fan,speed,occupancy, not cause harmful interference,and (2)this device must accept heating, cooling,9.and auto any interference received,including interference that may cause Seven-character lower display(with undesired operation. units of AM, PM,PPM,%,RH,and OAT)for local time and optional analog or binary values 3 HPO-9001 DISTRIBUTION MODULE The(future release) HPO-9001 NetSensor distribution module Enclosure and Mounting allows up to eight STE-9000 series NetSensors to be linked to one Clarity3 series controller. Mounting Provided with 3.25 x 4 inch(83 x 102 mm)Snap Track The module provides power(from a connected 24 VAC transformer) and addressing (according to the connected Environmental Limits port)for each NetSensor. It also allows one Operating 32 to 120° F(0 to 49° C) STE-6010/6014/6017 analog temperature sensor to be connected to a controller along with up to seven NetSensors. Shipping -40 to 160° F(-40 to 71° C) Humidity 0 to 95%relative humidity The module may be connected to a controller with an Ethernet (non-condensing) patch cable up to 150 feet(45 meters) long. Cables from the module to any NetSensors may also be up to 150 feet(45 meters) long. Warranty, Protocol, and Approvals The module board is mounted via supplied Snap Track. Warranty Taco Limited Warranty 5 years(from mfg.date code) Controller Compatibility P Y BACnet Clarity3 series t Regulatory `, f '' UL UL 916 Energy Management Equip- ment(pending) CE CE compliant(pending) Installation RoHS 2 RoHS 2 compliant(pending) Connections FCC FCC Class B, Part 15,Subpart B and complies with Canadian ICES-003 Connector type Eight-wire RJ-45 modular jacks Class B (pending)* Cable type Standard (Category 5 or better) Eth- *This device complies with part 15 of the FCC Rules. Operation ernet patch cable up to 150 feet(45 is subject to the following two conditions: (1)This device may meters) not cause harmful interference,and(2)this device must accept any interference received,including interference that may cause Power undesired operation. Supply voltage 24 VAC(-15%,+20%),50/60 Hz, Class 2 only;non-supervised (all circuits, including supply voltage,are power limited circuits) Wire size 12-24 AWG,copper,in removable screw terminal block SUPPORT Additional resources for installation,configuration, application, operation, programming, upgrading,and much more are available on the web at :,.tacocomfort.com. CO 2017 Taco Comfort Solutions. Specifications and design are subject to change without notice JE14 O P E fl O N Submittal Air Handler Temperature Sensor ACI A/AN Series Thermistor 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 Product Data Thermistor 1 1 1 1 1 1 A/AN Seriesannow A . . A/CP Series A/3K Series Automation Components, Inc. A/1.81( Series 1 A/20K Series j_, Product Description Temperature Sensor The A/10K-AN (Type III),A/10K-CP(Type II),A/3K,A/1.8K and Attributes A/20K Series temperature sensors are thermistor type sensors. These sensors provide a predictable output over a specified temperature range • Offer high accuracy and to meet each manufacturer's required input values. (See interchangeability over a www.workaci.com for complete curve chart specifications) id temperature range. - NI These units are offered in Room, Room with Setpoint, Room with • Higher resistance output Override, Room with Setpoint and Override, and Room w/ Setpoint, relative to Platinum RTD's Override, and RJ11 Jack, Stainless Steel Duct and Duct without Box, ; Immersion, Stainless Plate, Raw, Bendable Copper and Stainless Steel Rigid Averaging, Strap-On, Bullet Probe, Button Sensor, and Outdoor • Non-polarity sensitive Air Configurations. r • CE approval for thermistors All ACI Room sensors may be ordered with an optional setpoint(see except for: chart on the following page), override, or with a 4 pin RJ11 or 6 pin -Averaging sensors RJ12 communication jack with terminal blocks, for remote - LCDs and units that p okramming. These units are also available with a 1/8" RS232 Stereo have leads longer than 3 meters These products are covered by ACPs Five(5)Year Limited Warranty,which is located in the front of _ ACI'S SENSORS&TRANSMITTERS CATALOG or can be found on ACI's web site,which is: www.workaci.com. Applications • OEM / Industrial • Light Industrial c r, h • DDC Systems c.G c Sensor Output 10K Ohms @ 77°F(25°C)Type III c, 10K Ohms @ 77°F(25°C)Type II 3K Ohms @ 77°F(25°C) 1.8K Ohms @ 77°F(25°C) 20K Ohms @ 77°F(25°C) Accuracy(0 to 70°C) +/-0.2°C (+/-0.36°F) r r Stability +/-0.13°C(0.23°F) Operating Temperature Range -40 to 302°F(-40 to 150°C) r. Operating Humidity 0 to 90%RH non-condensing g �um..s„aor Interchangeability +/-0.2°C(+1-0.36°F) Power Dissipation Constant 3 mW/°C 7 For sensors with Display option,see LCD Series Temp display cut sheet r 7 Automation Components, Inc. 2305 Pleasant View Rd. r !Middleton,Vs 153562 PH: (608)831-2585 "c Wiring Diagrams available at www.workaci.com Fix: (608)831-707 ( z-5 Ordering Information AN=type III CP=type II A/AN, A/CP, A/3K, A/1.8K or A/20K (choose configuration below) -Configuration -Length -Enclosure Type -Optional Plenum Wire A l' D (Duct) 4",8",12",18" PB,GD,BB,4X,EH DO (Duct without Box) 4",8",12",18" 6'CL2P,10'CL2P,20'CL2P _ I (Immersion w/well) 2.5",4",6" PB*,GD,BB,4X,EH INW (Immersion no well) A 2.5",4",6" PB*,GD,BB,4X,EH (Copper Averaging) 8',12',24' PB,GD,BB,4X,EH FA (Flex.Cable Averaging) 8',12',24' PB,GD,BB,4X,EH • RA (Rigid Averaging) 18",24",36" PB,GD,BB,4X,EH •i >r S (Strap) PB*,GD,4X 0 (Outdoor Air) EH,BB,4X SP (Stainless Plate) W (Raw Potted Sensor) Enclosure Key W-6' (Raw w/6'Leads) PB=Plastic Box BP (Bullet Probe) GD=Galvanized Box BP-20'Z (BP w/20'of Zip Wire) BB=NEMA 3R i BBS (Brass Button Sensor) 4X=NEMA 4X SBS (Stainless Button Sensor) EH=Euro Housing (Weather tight) PBS (Plastic Button Sensor) *Please note that the-PB(Plastic Box)is rated to 140°F and may not be suitable for high temperature applications. Example: A/AN-D-4"-PB r. v Room configurations: .J Configuration Communication Jack Pot Value* Setpoint Indicator* Pot Action* [ �1 - [�l -[ �� -[ Al -[ A � R2 (Room) RJ4 (4 Pin RJl l) 400 5K Cool I W arm DA (Direct) R2S* (Room w/Setpoint) RJ6 (6 Pin RJI2) 1K 8.5K 55 t o 85 RA (Reverse) x R20 (Room w/Override) RS232 (Stereo Jack) 2K 10K 10 t o 30°C e. R2SO* (Room w/Setpoint&Override) 3K 20K r 100K r_ 1 Room Sensors with*require setpoint specs(value,indication,and action)and are not listed on your packing slip or invoice. R2=New Aries Enclosure OR R=Previous Infinity Enclosure (Please contact AC1 for display options) Example:A/AN-R2SO- 10K-Cool/Warm-DA or A/CP-R r.. NEW x Standard enclosure defaults: R r — 3.60"-- z.ts^ r titin 2\2 —[fi9.ssmml J 4 O Immersion units include / I` _ 1 1 09' / a 304 SS thermowell I —' [z7evmml li 1 � /0 �\. 4.060" �/ V -- _L__ a.3 5.00"—Z_ [11 2•000.. PROBE(3 0250" I62 J._V P> ., --{ f-- 0.85" I Z Duct Immersion I���, Outdoor Air z (Plastic Box) Room (Galvanized Box) (Euro Enclosure) J i 2305 Pleasant View Road Middleton, WI 53562 PH: (888) 967-5224 www.workaci.com ( T6 JB4 OREGON Submittal Relays RIB Pilot Series Relays 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 RELAYS & CONTACTORS FUNCTIONAL DEVICES RELAY IN A BOX RIB,RIBT l ith DESCRIPTION 'Functional RIB. Lrev}ces, me The Relay In A Box(RIB)Pilot Series controls most BAS, HVAC, low-horsepower motor and lighting applications.The relays come mounted and pre-wired in a housing, saving the a< installer the time,trouble, and expense of buying separate components(relay,socket, mounting rail,and enclosure)and assembling them on the job or at the shop. The RIB Pilot Series has a protruding 1/2"or 3/4" NPT nipple from which all wires exit(except T series).To install, remove a conduit knockout in the equipment, insert the wires *, and nipple through the hole,tighten the locknut, and connect • .,•- the wires. RIB Pilot Series-10A Relays RIBU1C RIBU1S The RIB Pilot Series has relay contacts rated for 10A and is used to control light electrical loads,drive power relays/ COus contactors,or sense the voltage being fed to electrical loads. The RIB Pilot Series requires a low coil-drive current and is FEATURES provided with circuitry to allow powering the relay coil from a wide range of AC or DC voltages. • Convenient and economical to use • Relay status indicator via LED RIBT Series-High/Low Voltage Separation • Coil uses low current and accepts a wide range of AC The RIBT Series is designed to provide physically separate and DC voltages entrances for connections to the relay input coil and output • Closed/Open/Auto switch option available contacts.Relay contact wires exit the housing through a • Nipple-or screw-mountable 1/2"or 3/4"NPT nipple.The cover of the RIBT Series is • Compact,gray plastic enclosure cc removable, and the coil drive wires can enter the housing • Color-coded wires for eliminating errors 0 through one of two convenient openings with star bushings • UL listed for UL916 Energy Management and UL864 U or 1/2"conduit.The coil drive wires are secured to screw Fire < terminals within a separate wiring compartment in the • Made in the USA RIBT Series.Most of the RIB's in the Pilot Series are also 0 available in the RIBT Series. 025 >-- LLIQ J SPECIFICATIONS-GENERAL Wire Length 16"(40.6 cm) Approvals UL listed, UL 916 Energy Life Rating 10 million cycles minimum Management UL 864 Fire,cUL listed, mechanical CSFM Relay Status LED, ON- relay activated Weight 1.0 lb(0.45 kg) 20 Operating Temperature -30°to 140°F(-34°to 60°F),-30°to Warranty 1 year 140°F(-34°to 60°C) Operating Humidity 5 to 95%non-condensing Housing Type Plenum rated, NEMA 1, NEMA 4 Coil pull-in/drop-out(nominal values) Conduit Hub 1/2" NPT, 3/4"NPT Dimensions A size enclosures: PULL IN DROP-OUT 1.7"H x 2.8"W x 1.5"D COIL DRIVE DC AC DC AC (4.32 x 7.11 x 3.81 cm), 10-30 VACNDC 10 9 2.8 2.1 24 VACNDC 20 18 3.8 3 B size enclosures: 120 VAC - 102 - 9 4.0" H x 4.0"W x 1.8" D 208-277 VAC — 176 — 13 (10.16 x 10.16 x 4.57 cm), G size enclosures: 2.3"H x 3.2"W x 1.8" D (5.84 x 8.13 x 4.57 cm) 942 ©2012 Kele,Inc All rights reserved.The Kele name and logo are registered trademarks of Kele,Inc. January 202 RELAYS & CONTACTORS - FUNCTIONAL DEVICES RELAY IN A BOX 'ir RIB, RIBT PILOT SER/ES LI SPECIFICATIONS- PILOT SERIES COIL SIZE/ OVR RELAY RELAY RELAY COIL MODEL TYPE DRIVE HUB SW CONTACT RATINGS CONTACT WIRING DRIVE DATA RIBU 1 C' 1 OA resistive 120/240/277 VAC Relay#1 RIBU1C-N4t 1-SPDT — 10A resistive 28 VDC NC —(blue) 12 VACCNDc A-1/2 480 VA pilot duty 240/277 VAC COM (yellow) RIBU2C* 2-SPDT 50/60 Hz — 480 VA ballast 277 VAC NO L(orange) G-3/4 600W tungsten 120 VAC N.O. 240W tungsten 120 VAC N.C. Relay#2(if present) RIBHIC* 1-SPDT 10-30 VAC — 1/3 hp for N.O. 120/240 VAC NC r—(gray) Wiring RIBH1C-N4t 208-277 VAC A-1/2 1/6 hp for N.C. 120/240 VAC711-i Relay#1 50/60 Hz 1/4 hp for N.O. 277 VAC COM I (purple) Common-White/Yellow wire RIBH2C' 2-SPDT G-3/4 1/8 hp for N.C. 277 VAC NO -L(brown) 10-30 VACNDC-White/Blue wire 1030 VACNDC 11. 120 VAC-White/Black wire If— 208-277 VAC-White/Brown wire 120 VAC Auto Vow) Relay#2(if present) RIBU1SC* 1-SPDT 50/60 Hz G-1/2 Yes-2 Manual CCoommmon Common-White/Purple wire 10-30 VAC N.C.-Closed o (blue)N.C. 10-30 VACNDC-Gray/White wire RIBH1SC* 1-SPOT 208-277 VAC Yes-2 Open120 VAC WhitelRed wire 50/60 Hz G-1/2 ND 0 (orange)N.O. 1 OA resistive 277 VAC .o. 208-277 VAC- -White/Orange wire RIBU1 S' 1-SPST-NO" Yes 480 VA pilot duty 277 VAC Rely(orange) Closed G-1/2 480 VA ballast 277 VAC RIBU2SC 1-SPST-NO" Yes 600W tungsten 120 VAC N.O. (orange)_------o Open i 1030 VACNDC 240W tungsten 120 VAC N.C. 9 Auto 1-SPDT 120 VAC G-3/4 1/3 hp for N.O. 120-240 VAC Input Current RIBU2S2 2-SPST-NO" 50/60 Hz B-3/4 Yes-2 1/6 hp for N.C. 120-240 VAC Relay#2 of RIBU2S2 30 mA @ 10 VAC Closed (brown) RIBU1 SM 1-SPST-NO" Yes+ 1/4 hp for N.O. 277 VAC Open o (brown) 32 mA @ 12 VAC G 1/2 Status 1/8 hp for N.C. 277 VAC , 42 mA @ 24 VAC oy Auto 50 mA 0 30 VAC RIBH1S* 1-SPST-NO" Yes Relay#2 of RIBU2SC 25 mA 0 120 VAC G-1/2NC r—(gray) 35 mA 0 208-277 VAC Status Contact COM r-_(purple) 12 mA @ 10 VDC on RIBU1SM and RIBH1SM: NO Z_(brown) 14 mA it 12 VDC 10-30 VACNDC Yes+ 5A max @ 277 VAC 77 208-277 VAC STATUS=2nd Pole of 16 mA @ 24 VDC m RIBH1SM 1-SPST-NO" Status switch of RIBU1SM,RIBH1SM 18 mA©30VDC r- 50/60 Hz G-1/2 Closed o—(brown) Open off—(purple) (_/) Auto o—(gray) Qo 24 VACNDC 1 OA resistive 30 VDC Wiring n RIB2401 D' 1-DPDT — Common-White/Yellow wire 120 VAC 10A resistive 277 VAC NC (blue) O RIB2401 D-N4t 50/60-Hz A-1/2 1/2 hp for N.O. 120/240 VAC COM' (yellow) 24 VACNDC-White/Blue wire Z 11/3 hp for N.C. 120/240 VAC NO --(orange) 208-27708 VAC-1C-White/ wire —I VAC-White/Brown wire 24 VACNDC 10A resistive 30 VDC NC (gray) Input Current n RIB2402D 1-DPDT 208-277 VAC — 10A resistive 277 VAC "-- 24mA ,18VAC 20mA 0 20VDC `50/60 Hz A 180 VA pilot duty 120 VAC M (brown) 32 mA @ 24VAC 24 mA @ 30VDC 0 1/8 hp for N.C. 120 VAC t ) 4omA@30 VAC 36mA@30VDC 70 RI62402D-N4t 1 /2 NO 31 mA 0 120 VAC(RIB2401D) 36 mA CO 208-277 VAC(RIB2402D) 10A resistive 120-277 VAC Relay#(black) Wiring RIBL3C 3 SPSTNO 10A resistive 28 VDC Common-White/Red wire 3gpSTNO 10-30VACNOC B-1/2 _ Z—(black) 50160 Hz 480 VA pilot duty 240-277 VAC Relay#1-White/Black wire RIBL4C 1-SPOT B-1/2 — 480 VA ballast 277 VAC Relay#2 (blue) Relay#2-White/Blue wire 600W tungsten 120 VAC N.O. —(blue) Relay#3-White/Yellow wire 240W tungsten 120 VAC N.C. Relay#3 Relay#4-White/Brown wire 1/3 hp for N.O. 120-240 VAC (yellow) (if present) 1/6 hp for N.C. 120-240 VAC —(yellow) Input Current 1/4 hp for N.O. 277 VAC Relay#4(if present) 30 mA©10 VAC 12 mA©10 VDC 1/8 hp for N.C. 277 VAC NC (gray) 32 mA CO 12 VAC 14 mA @ 12 VDC COM t (purple) 42 mA 0 24 VAC 16 mA @ 24 VDC NO T--(brown) 50 mA CO 30 VAC 18 mA @ 30 VDC SPDT .—(blue) $1802$ Manual — Yes Switch ratings . —(yellow) No Relay Switch A-1/2 20A 277 VAC (orange) Switch O^� ORDERING INFORMATION Order by model number 'Models may be ordered in RIBT Series with high/low voltage separation. **Can be ordered normally closed by adding-NC after model number. t N4 has NEMA 4 housing January 2012 O70II Kele,Inc.All rights reserved.The Kele name and logo are registered trademarks of Kele,Inc. kele.com 1888-397-5353 USA 1001-901-382-6084 International . . JB4, OREGON Submittal Controls Enclosure Kele HC Series NEMA 1 Cover Box 735 SW 20 " Place 230 , Portland , OR 97205 PHONE (971) 717-7123 „A ENCU NEMA 1 HINGE COVER BOXES 2sii f DESCRIPTION The Kele HC Series NEMA 1 hinge cover boxes serve as surface-mounted junction boxes or switch boxes.With the addition of a field-installed perforated subpanel,they can also house controls and instruments in areas that do not require oil-tight and dust-tight ratings. ) FEATURES 1,1 • 16-gauge steel construction meets NEMA 1 • Removable doors with butt hinges #? • Door hinge on left or right side • Mounting holes on back of enclosure • Easy operation of flush latch with a screwdriver or coin • Various sizes of easily removable knockouts on all sides HC Series • ANSI 61 gray polyester-powder finish inside and out a t:®'s over phosphatized surfaces Fj • Available with optional perf panel L,-):: • UL File#E27525 -- • CSA File#LL42184,RoHs DIMENSIONS cc = • One-year warranty Four mounfing in holes c p (cm)/0-3gado -.- (-) V - 0 -� Hush- 0- [ n-1.06(269) mounted U can latch Owing � O e-,.06(269) 0 - �- operu5 ~- 9Knockouts/// on all side. Patterns and sizes vary w,6,enclosure size. ORDERING INFORMATION ENCLOSURE DIMENSIONS WEIGHT OPTIONAL PERF PANEL MODELt A x B x C in(cm) lb(Kg) DIMENSION SIZE H x W in(cm) HC664 6 x 6 x 4 (15 x 15 x 10) 3.2 (1.5) 4.25 x 4.25(11 x 11) HC666 6 x 6 x 6 (15 x 15 x 15) 4.0 (1.8) 4.25 x 4.25 (11 x 11) HC886 8 x 8 x 6 (20 x 20 x 15) 6.0 (2.7) 6.25 x 6.25 (16 x 16) HC1084 10 x 8 x 4 (25 x 20 x 10) 7.0 (3.2) 8.25 x 6.25(21 x 16) HC1284 12 x 8 x 4 (30 x 20 x 10) 8.0 (3.6) 10.25 x 6.25 (26 x 16) HC12104 12 x 10 x 4 (30 x 25 x 10) 8.0 (3.6) 10.25 x 8.25 (26 x 21) HC12124 12 x 12 x 4 (30 x 30 x 10) 8.8 (4.0) 10.25 x 10.25 (26 x 26) HC12126 12 x 12 x 6 (30 x 30 x 15) 10.3 (4.7) 10.25 x 10.25 (26 x 26) HC16124 16 x 12 x 4 (41 x 30 x 10) 12.0 (5.5) 14.25 x 10.625 (36 x 26) HC16126 16 x 12 x 6 (41 x 30 x 15) 13.0 (5.9) 14.25 x 10.25 (36 x 26) HC18124 18 x 12 x 4 (46 x 30 x 10) 12.0 (5.4) 16.25 x 10.25 (41 x 26) HC18126 18 x 12 x 6 (46 x 30 x 15) 14.0 (6.4) 16.25 x 10.25 (41 x 26) t Add P to the end of part number to order optional perf panel.(Standoffs are field installed,drilling required.) See Hoffman Enclosure Accessory page in the Enclosure section for locks, latches,heaters,fans,and ventilation kits.Additional box sizes available. 817-826-9037 USA kele.com ONE CALL.ONE INVOICE. ONE SOURCE. September 2016 OREGON Submittal 24VAC Transformer RIB PSH300A 735 SW 20 " Place 230 , Portland , OR 97205 PHONE (971) 717-7123 t ' RSB. Functional Devices, InC." ` (800)888-5538 ►r sales@functionaldevices.com ® www.functionaldevices.com AC POWER SUPPLY .... - PSH300A PSMN300A C �l us Enclosed 300VA Power Supply with Three 100VA )pen Style 300VA Power Supply with Three 100VA Class 2 Outputs,480/277/240/120 Vac to 24 Vac Class 2 Outputs,480/277/240/120 Vac to 24 Vac LISTED PSH300A Class 2 Shown ;�r-> ��1�� 7 With C E . 480 Cover 277 Al 240'• a RoHS 120 O COM ( Made USA (D -c—a-N ..,-_ ,. 24V Q ,,.P of ARRA 2009 U PSH300A 4__. © '''F 0$ COM .6 Shown b {.,� 0 0‘. 24V 3 Without Ti to c._ `C]0 OFF + COM Cover _r W3e- , © Cr ' + 24V cOi N ® OFF 0$ COM is ......?„..Y- ......9...„, Switch Indicator ii Breaker P5MN300A SPECIFICATIONS Transformer: One(1)300 VA 3 Secondaries: Standby Wattage: Over Current Protection: Circuit Breaker 24 Vac,with LED Indicators 16.61 W @ 120 Vac Primary: 480/277/240/120 Vac 4 Amp breaker for each output 17.70 W @ 240 Vac Frequency: 50/60 Hz 16.26 W @ 277 Vac Dimensions: 12.125"x 12.125"x 6.000"(PSH300A) 24 Vac ON/OFF: 19.20 W @ 480 Vac 11.330"x 11.400"x 4.500"(PSMN300A) On/Off Switch&Breaker Approvals: Class 2(UL Approved UL5085-3), Full Load Primary Current: UL916,UL508,C-UL,CE,RoHS,Special Input: 2.66 A @ 120 Vac A Seismic Certification of Equipment 480/277/240/120 Vac Finger-Safe Terminals, 136 A @ 240 Vac and Components:OSP-0201-10 8-18 AWG 1.18 A @ 277 Vac Sub-Panel: Plenum Rated Polymetal 0.68 A @ 480 Vac Sub-Panel(PSMN300A) Output: Housing: NEMA1 Metal Enclosure(PSH300A) 3 Ungrounded,Isolated,100 VA,Class 2,24 Vac Secondary Output Voltage vs.Load: Weight: 20.00 lbs.(PSH300A) Outputs.Terminals accept 12-26 AWG wire. 24.5 V @ 1 Amp 11,00 lbs.(PSMN300A) 23.5 V @ 2 Amp Ambient Temperature Derating: 22.8V @ 3 Amp 4Aupto40`C;3Aupto50°C;2Aupto55°C 22.3V @ 4Amp (When All 3 Outputs Operated Simultaneously) .With 120 Vac primary input voltage •When all 3 outputs operated Notes: simultaneously,at room •To order UL508,add"-IC"to end of model number. temperature •Open style(PSMN300A)is mounted to sub-panel SP3303 for shipping.Sub-panel may be removed to suit application. •Primary voltage terminal cover available.See model APS53-TC on page 141. •Design is in accordance with ASCE 7-05 Chapter 13:A www.oshpd.ca.gov/FDD/Pre-Approval/OSP-0201-10.pdf GREAT FOR VAV APPLICATIONS 102615