Loading...
Plans (245) hew Deck Project:Providence_Biggi Construction_Lot 8 Oak Woods ;'"U '.� vase - Keith A Kudrna Location:Beam Nr.03a-Rear Deck Beam Suntel Design Uniformly Loaded Floor Beam 16865 Boones Ferry Rd [2012 International Building Code(2012 NDS)] ,r y, Lake Oswego,Oregon 97035 5.5 IN x 11.25 IN x 13.5 FT #1 -Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 1/18/2018 11:25:31 AM Section Adequate By:57.6% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.21 IN L/755 Dead Load 0.05 in Total Load 0.26 IN L/623 Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240 REACTIONS A4 ] Live Load 2025 lb 2025 lb Dead Load 428 lb 428 lb Total Load 2453 lb 2453 lb Bearing Length 0.71 in 0.71 in SEAM DATA Center Span Length 13.5 ftUnbraced Length-Top 0 ft 13.5 ft Floor Duration Factor 1.00 Notch Depth 0.00 MATERIAL PROPERTIES FLOOR LOADING #1 -Douglas-Fir-Larch Side 1 Side 2 ease Values Adjusted Floor Live Load FLL= 60 psf 0 psf Bending Stress: Fb= 1350 psi Fb'= 1350 psi Floor Dead Load FDL= 10 psf 0 psf Cd=1.00 CF=1.00 Floor Tributary Width FTW= 5 ft 0 ft Shear Stress: Fv= 170 psi Fv'= 170 psi Cd=1.00 Wall Load WALL= 0 plf Modulus of Elasticity: E= 1600 ksi E= 1600 ksi Comp.-I-to Grain: Fc- = 625 psi Fc--- = 625 psi BEAM LOADING Beam Total Live Load: wL= 300 plf Controlling Moment: 8279 ftIb Beam Total Dead Load: wD= 50 plf 6.75 ft from left support Beam Self Weight: BSW= 13 plf Created by combining all dead and live loads. Total Maximum Load: wT= 363 plf Controlling Shear: 2159 lb At a distance d from support. Created by combining all dead and live loads. Comparisons with required sections: Req Provided Section Modulus: 73.59 in3 116.02 in3 Area(Shear): 19.05 in2 61.88 in2 Moment of Inertia(deflection): 311.34 in4 652.59 in4 Moment: 8279 ft-lb 13052 ft-lb Shear: 2159 lb 7013 lb NOTES