Plans (133) I I IDA.,. : ,11/4r' O - Lr a ‘ttilsLS ` q{,\CAb(...- \-kk")'1/4:,IS NOTES: 1, SCOPE OF WORK IS FOR THE DESIGN OF THE POLES, BASE PLATE,ANCHORAGE AND FOOTING. 2. SEE FOLLOWING PAGES FOR STRUCTURAL NOTES. 4,-O" I 1 1 ,�:::2::4 ‘ PROFFssi i`' ,', •: GON o .1 I I i4Ry 08, I"NIS: s JOSEPH O% I EXPIRES: 12-31-2018 0 — ISI lo 11" 7" HSS 8x3x1 4, 3/4"DIA. HOG ROD / EMBEDDED 30"INTO TYP. FOOTING WITH DOUBLE NUT AND ©III O WASHER, TTP. s/eI 7W• 2"MAX 5,000 PSI NON-SHRINK GROUT TYP © . #5 AT 12"D.C. EA I V ��r WAY AT FRONT AND 04 1 111111111111111 ' ,_ .�,- BACK OF FOOTING `!may 1111111111111111 �� i PLATE STEEL CONCRETE FOOTING 6-O" x 2'-0" I ®SIGN ELEVATION 0 BASE PLATE 1/2"=1'-0• 3"4.1.-0. 9570 SW Barbur Blvd Project Name Shell Pylon Sign Project# 180804 Suite One Hundred at Portland,OR 97219 Pacific Highway, Ti ard, Oregon la Location 9 9 Client Ramsay Signs MILLER Phone 503.246.1250 p CONSULTING Fax 503.246.1395 CJM L f 6/7/18 Si of 4 www.miller-se.com By Ck'd Date Page ENGINEERS • GENERAL THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND CORRELATION OF ALL ITEMS AND WORK NECESSARY - • FOR COMPLETION OF THE PROJECT AS INDICATED BY THE CONTRACT DOCUMENTS. SHOULD ANY QUESTION ARISE REGARDING THE CONTRACT DOCUMENTS OR SITE CONDITIONS, THE CONTRACTOR SHALL REQUEST INTERPRETATION AND CLARIFICATION FROM THE ENGINEER BEFORE BEGINNING THE PROJECT. THE ABSENCE OF SUCH REQUEST SHALL SIGNIFY THAT THE CONTRACTOR HAS REVIEWED AND FAMILIARIZED HIMSELF WITH ALL ASPECTS OF THE PROJECT AND HAS COMPLETE COMPREHENSION THEREOF. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE TO ALL SAFETY REGULATIONS DURING CONSTRUCTION. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE SPECIFICALLY NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION OR CONSTRUCTION LOADS. ONLY THE CONTRACTOR SHALL PROVIDE ALL METHODS, DIRECTION AND RELATED EQUIPMENT NECESSARY TO PROTECT THE STRUCTURE, WORKMEN AND OTHER PERSONS AND PROPERTY DURING CONSTRUCTION. THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, ENGAGE PROPERLY QUALIFIED PERSONS TO DETERMINE WHERE AND HOW TEMPORARY PRECAUTIONARY MEASURES SHALL BE USED AND INSPECT SAME IN THE FIELD. ANY MATERIAL NOT AS SPECIFIED OR IMPROPER MATERIAL INSTALLATION OR WORKMANSHIP SHALL BE REMOVED AND REPLACED WITH SPECIFIED MATERIAL IN A WORKMANLIKE MANNER AT THE CONTRACTOR'S EXPENSE. THESE PLANS, SPECIFICATIONS, ENGINEERING AND DESIGN WORK ARE INTENDED SOLELY FOR THE PROJECT SPECIFIED HEREIN. MILLER CONSULTING ENGINEERS DISCLAIMS ALL LIABILITY IF THESE PLANS AND SPECIFICATIONS OR THE DESIGN, ADVICE AND INSTRUCTIONS ATTENDANT THERETO ARE USED ON ANY PROJECT OR AT ANY LOCATION OTHER THAN THE PROJECT AND LOCATION SPECIFIED HEREIN. OBSERVATION VISITS TO THE JOB SITE AND SPECIAL INSPECTIONS ARE NOT PART OF THE STRUCTURAL ENGINEER'S RESPONSIBILITY UNLESS THE CONTRACT DOCUMENTS SPECIFY OTHERWISE. NON STRUCTURAL PORTIONS OF PROJECT, INCLUDING BUT NOT LIMITED TO PLUMBING, FIRE PROTECTION, LAND USE, SITE PLANNING, EROSION CONTROL, ELECTRICAL, MECHANICAL, FLASHING AND WATER-PROOFING ARE BEYOND THE SCOPE OF THESE DRAWINGS AND ARE PROVIDED BY OTHERS. EXISTING STRUCTURAL ELEMENTS ARE DESIGNED BY OTHERS. SPECIAL INSPECTION OF WELDS AND POST INSTALLED ANCHORS ARE TO BE PROVIDED BY A SPECIAL INSPECTION AGENCY AS REQUIRED BY THE BUILDING OFFICIAL FOR ELEMENTS OF THE PROJECT THAT DO NOT MEET THE APPROVAL OF CONSTRUCTION OF A MINOR NATURE OR AS WARRANTED BY CONDITIONS IN THE JURISDICTION (SECTION 1704.2, EXCEPTION 1). CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO FABRICATION OR INSTALLATION. ENGINEER OF RECORD FOR THE PROJECT IS TO BE NOTIFIED IF CONDITIONS DIFFER FROM WHAT IS SHOWN ON THE DRAWINGS. BUILDING CODE ALL PHASES OF THE WORK SHALL CONFORM TO THE 2014 OREGON STRUCTURAL SPECIALTY CODE, BASED ON THE 2012 INTERNATIONAL BUILDING CODE, INCLUDING ALL REFERENCE STANDARDS, UNLESS NOTED OTHERWISE. 4 ED PROF4, (WI7G t N F 14 72 25P C •: GON o Yip- JOSEPH VP' EXPIRES: 12-31-2018 9570 SW Barbur Blvd Project Name Shell Pyion Sign Project# 180804 Suite One Hundred Portland,OR 97219 Pacific Highway, Tigard, Oregon Location Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJM Lf� 6/7/18 S2of4 www.miller-se.com BY Ckd Date Page ENGINEERS DESIGN LOADS THE FOLLOWING ARE THE DESIGN REQUIREMENTS: . STRUCTURAL DESIGN CRITERIA RISK CATEGORY II WIND DESIGN DATA BASIC WIND SPEED(3 SEC GUST) 120 MPH EXPOSURE B FOOTINGS FOUNDATION CRITERIA CONTRACTOR SHALL VERIFY SOIL CONDITIONS AT THE FOOTINGS AND MAKE ANY NECESSARY CORRECTIONS TO PLACE THEM ON FIRM NATIVE SOIL OR STRUCTURAL FILL COMPACTED TO 95% OF MAXIMUM DENSITY AT OPTIMUM MOISTURE CONTENT PER AMERICAN SOCIETY FOR TESTING AND MATERIALS, ASTM D698 (STANDARD PROCTOR), OR ASTM D1557 (MODIFIED PROCTOR). THE COMPACTION SHALL BE VERIFIED BY A QUALIFIED INSPECTOR APPROVED BY THE BUILDING OFFICIAL. COMPACTED STRUCTURAL FILL FOR DEPTHS GREATER THAN 12 INCHES SHALL COMPLY WITH PROVISIONS OF AN APPROVED GEOTECHNICAL REPORT. ASSUMED SOIL BEARING PRESSURE 1500 POUNDS PER SQUARE FOOT(PSF). CONCRETE CONCRETE MIXING, PLACING AND CURING OF CONCRETE SHALL BE IN ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE,ACI 318 AND IBC CHAPTER 19. CONCRETE SHALL BE 2500 POUNDS PER SQUARE INCH (PSI) MINIMUM AT 28 DAYS. ALL CONCRETE WITH REINFORCEMENT SHALL HAVE NO CHLORINE OR CHLORIDES. WHERE NEW CONCRETE IS PLACED AGAINST EXISTING CONCRETE, THE EXISTING CONCRETE SURFACE SHALL BE CLEANED AND ROUGHENED TO A MINIMUM 1/4" AMPLITUDE PER ACI 318 11.6.9. SET ALL ANCHOR BOLTS AND DOWELS BEFORE POURING CONCRETE. REINFORCING STEEL ALL REINFORCING STEEL SHALL BE DEFORMED BARS PER ASTM A615 OR A706 GRADE 60.ALL REINFORCING STEEL TO BE WELDED SHALL BE ASTM A706.ALL WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. UNLESS NOTED OTHERWISE, SET MAIN REINFORCING STEEL 3"FROM EARTH AND 2"FROM FORMED SURFACES. BAR LENGTHS DETAILED ARE OUT TO OUT AND DO NOT INCLUDE ALLOWANCE FOR HOOKS OR BENDS. USE MINIMUM 30" LAP FOR#4 BAR AND SMALLER UNLESS NOTED OTHERWISE (UNO). USE MINIMUM 36" LAP FOR#5 BAR UNO. ALL REINFORCING STEEL SHALL BE SUPPORTED ON WELL-CURED CONCRETE BLOCKS OR APPROVED METAL CHAIRS, AS SPECIFIED BY THE CRSI MANUAL OF STANDARD PRACTICE, MSP-1, AND SHALL BE SECURELY TIED IN PLACE WITH#16 ANNEALED IRON WIRE. REINFORCING STEEL SHALL BE DETAILED IN ACCORDANCE WITH THE "ACI MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES,"ACI 315. NON-SHRINK GROUT ALL NON-SHRINK GROUT SHALL BE NON-METALLIC GROUT CONFORMING TO ASTM C1107, AND SHALL HAVE A SPECIFIED MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 5000 PSI. PRE-GROUTING OF BASE PLATES IS NOT PERMITTED. <��D PRO,�j �o ` NF42 ks; 4,4 4/ 72 25P Ilia C •; GON o �G o qRY Oa .15,O' i. �`� JOS EPH'IPs EXPIRES:12-31-2018 9570 SW Barbur Blvd Project Name Shell Pylon Sign Project# 180804 Suite One Hundred at Portland,OR 97219 Pacific Highway, Ti Tigard, Oregon Ila Location g 9 Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395CJM www.miller-se.com By Ck'd Date Page ENGINEERS STRUCTURAL STEEL STRUCTURAL STEEL • • ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE ASTM A992 FOR W-SECTIONS AND ASTM A36 FOR ALL OTHER SECTIONS, PLATES AND BARS. ALL RECTANGULAR HSS SECTIONS SHALL BE ASTM A500, GRADE B, FY=46000 PSI AND ALL ROUND HSS SECTIONS SHALL BE ASTM A500, GRADE B, FY=42000 PSI. ALL STRUCTURAL STEEL PIPE SHALL BE ASTM A53, GRADE B, TYPE E OR S, FY= 35000 PSI. ALL STEEL IN CONTACT WITH ALUMINUM TO BE STAINLESS OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. UNLESS NOTED OTHERWISE, ALL BOLTS TO BE ASTM A307 AND ALL ANCHOR RODS TO BE ASTM F1554 GRADE 36, WITH MATCHING NUTS. ALL FASTENERS IN CONTACT WITH ALUMINUM TO BE TYPE 304 STAINLESS STEEL WITH MATCHING NUTS OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. NUTS SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION PER RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (RCSC) SPECIFICATION FOR STRUCTURAL JOINTS, SECTION 8.1. ALL STRUCTURAL STEEL SHALL HAVE ONE COAT OF PRIMER, EXCEPT SURFACES TO BE EMBEDDED IN CONCRETE OR MASONRY. EMBEDDED SURFACES SHALL BE FREE OF CONTAMINANTS. ALL ZINC (GALV.) COATINGS ON IRON AND STEEL PRODUCTS SHALL CONFORM TO ASTM A123. REPAIRS OF GALVANIZED COATINGS ARE TO CONFORM TO ASTM A780. ALL EXPOSED STRUCTURAL STEEL TO HAVE ONE FINISH COAT OF RUST INHIBITING PAINT, COLOR BY OWNER. ALL WELDING SHALL CONFORM TO AMERICAN WELDING SOCIETY (AWS) D1.1 USING E70XX ELECTRODES. WELD LENGTHS SHOWN ARE EFFECTIVE AS SPECIFIED PER THE SPECIFICATIONS OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). WELDING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS FOR WELD TYPES SPECIFIED. WHERE WELD LENGTHS ARE NOT SHOWN, THE WELD SHALL BE FULL LENGTH OF MEMBERS BEING JOINED. ALL BUTT WELDS SHALL BE FULL PENETRATION WELDS UNLESS NOTED OTHERWISE ON STRUCTURAL DRAWINGS.ALL WELDS SHALL RECEIVE THE SAME FINISH COAT AS THE MEMBER BEING WELDED. OD PRO, c., GtNF � 4` 7225P � i . •• GON o ttt , qRy 05 ti��QQ s JOSEPH MPS©. EXPIRES:12-31-2018 Shell Pylon Sign 180804 9570 SW Barbur Blvd Project Name Project# Suite One Hundred E Portland,OR 97219 Pacific Highway, Tigard, Oregon Location Client Ramsay Signs MILLER Phone 503.246.1250 CONSULTING Fax 503.248.1395CJM L P3" 6/7/18 S4 of 4 www.miller-se.com By Ck d Date Page ENGINEERS