Report (51)
• -1•e\ ,s‘zZQ I (A-1 y d Project: .;;v,S:CN To install a fire sprinkler alarm monitoring system to be monitored by a 24 hr. U.L. Approved Central Station For: Agityx Corp 7904 SW Hunziker St, Tigard, OR 97223 Contractor: Protection SECA/Rill' SOLUTIONS Protection One 7312 SW Durham Rd., Portland , OR 97224 CCB# 116325 & 34-428CLE Phone: (503) 443-2923 Fax: (866) 223-9925 N.F.PA Record of Completion Instructions: There are 3 copies of this document each requires the following: All areas of the document have been completed with the exception of: (Please verify the counts and types of devices as this document is based on equipment that was specified before plans check) Section 1 The date the contract for service is signed, shall be added to this section prior to the final inspection with the AHJ. A copy of this agreement shall be providing for verification by the AHJ at the final. Note: Contact amounts may be whited out. The AHJ only wants to see the signatures, dates, and services to be provided on the contract. Section 2 This is to be completed when the installation of the system is complete and is found to be in operational order by the installer. Section 3 This is to be completed when the persons doing the pre test, test the installation prior to the final inspection with the AHJ.As Protection One will be assuming the responsibility for this installation and the associated liability, this test is to be performed by a Protection One employee that is experienced in this type of installation and understands the functions of the system being tested. Section 11 This is to be completed at the time the system is inspected and tested with the IE... and Protection One personnel. When section 11 has been completed and signed by all parties the distribution shall be has follows: 1copY to the aco nt file Protection One 1 copy to the AHJ 1 copy to the owner or owner's representative 2 N.F.PA. Record of Completion Name of Protected Property: Agilyx Corp Address: 7904 SW Hunziker St. Rep. of Protected Prop_ (Name\phone) Authority Having Jurisdiction. Tigard City Fire Address/ Phone: / - 1. Type(s) of system services n/a NFPA 72, Chapter 6 - Local If alarm is transmitted to location(s) off premise, list where received: n/a NFPA 72, Chapter 6- Emergency Voice/Alarm Service Quantity of voice\alarm channels: single: multiple: Quantity of speakers installed: quantity of speaker zones: Quantity of telephones or telephone jacks included in system: n/a NFPA 72, Chapter 9 -Auxiliary Indicate type of connection: Local energy, shunt, parallel telephone, Location and telephone number for receipt of signals: n/a NFPA 72, chapter 6 - Remote Station Location for receipt of alarm signals: Location for receipt of supervisory signals: n\a NFPA 72, chapter 6 - Proprietary If alarms are retransmitted to public fire service communications center or others, indicate location and telephone number of the organization receiving Alarm: Indicate how alarm is retransmitted: NFPA 72, chapter 6- Central Station the prime contractor: Protection One 4221 W.John Carpenter Freeway Irving, TX 75063 Central station location: Same As Above 3 Means of transmission of-signals from the protected premise to the Central - - Station: McCulloh multiplex one way radio other Digital alarm communicator two way radio Means of transmission of the alarms to the public fire service communications center: 1. 2. System location: Organization name\phone representative name\phone Installer Protection One (503) 443.2923 Supplier Protection One (503) 443.2923 Service Co. Protection One (503) 443.2923 Location of record (as-built) drawings: Protection One 7312 SW Durham Rd. Portland, OR 97224 Location of owner's manuals: Operation directions on site Location of test report: A contract, dated , 2015, for test and inspection in accordance with NFPA Standard(s) no.(s) 72 , dated 2013 , is in effect. 2. Certification of system installation (Fill out after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting the operational acceptance tests.) This system has been installed in accordance with the NFPA standards as listed below, and was inspected by on , includes the Devices listed below and have been in service since XXX NFPA 72, chapters 1 3 4 5 6 7 8 9 10 11 (circle all that apply) XXX NFPA 70, national electrical code, article 760 )(XX manufacturer's instructions XXX Other(specify): OFC 2012, OBC 2012, Title 19 & 24 as Amended Signed: date: Organization: Protection One 4 3. Certification of system operation All operational features and functions of this system were tested by , on_ _and found to be operating Properly in accordance with the requirements of: XXX NFPA 72, chapters 1 3 4 5 6 7 8 9 10 11 (circle all that apply) XXX- NFPA 70, national electrical code, article 760 XXX Manufacturer's instructions XXX Other(specify) OFC 2012, OBC 2012 title 19 & 24 as amended Signed: date: Organization: Protection One Alarm Monitoring Co. (Protection One) 4. Alarm initiating devices and circuits (indicate quantity of devices) Manual: a) 1 manual stations X no coded, activating transmitter(s) coded b) Combination manual fire alarm and guard's tour coded stations Automatic: *note: this count is for new devices only Coverage: complete: partial: a) 1 smoke detectors ion X photo b) duct detectors ion photo c) heat detectors ft rr X ft\rr rc d) 1 sprinkler water flow switches: X noncoded, activating transmitters coded e) Other (list): 5. Supervisory signal initiating devices and circuits (indicate quantity of devices) Guard's tour: A) coded stations B) noncoded stations activating transmitters C) compulsory guard tour system comprised of transmitter stations and Intermediate stations Note: combination devices recorded under 4(b) and 5(a) a) 2 Valve supervisory signaling attachments b) Valve supervisory switches activating transmitters B) building temperature points C) site water temperature points D) site water supply level points Electric fire pump: E) fire pump power F) fire pump running G) phase reversal Engine-driven fire pump: H) selector in auto position I) engine or control panel trouble 5 J) fire pump running _ Engine-driven generator: K) selector in auto position L) control panel trouble _ - M) transfer switches N) engine running Other supervisory function(s) (specify: 6. Alarm notification appliances and circuits Quantity of indicating appliance circuits connected to the system: Types and quantities of alarm indicating appliances installed: A) bells inch B) speakers C) horns D) chimes E) other: F) 1 visual signals type: Horn Strobes 9 with audible w\0 audible G) 1 local annunciator *Note: this count is for new devices only 7. Signaling line circuits: Quantity and style (see NFPA 72, table 6-6) of signaling line circuits connected to system: Quantity: N/A style: N/A 8. System power supplies A) Primary (main): ac nominal voltage: 18.5 current rating: 40 va Over current protection: type: FUSED current rating: 40 va Location: B) Secondary (standby): XXX storage battery: amp-hour rating 7.0 Calculated capacity to drive system, in hours: X 24 60 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: C) Emergency or standby system used as backup to primary power supply, instead of Using a secondary power supply: Emergency system described in NFPA 70, article 700 Legally required standby system described in NFPA 70, article 701 Optional standby system described in NFPA 70, article 702, which also meets the performance requirements of article 700 or 701. 6 9. System software A) Operating system software revision level(s): 5.24 B) Application software revision level(s): N/A C) Revision completed by: From company: 10. Comments No Comment (signed) for Central Station or alarm Service Company Title date 11. Final acceptance For central station or alarm Service Company Title date Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA Standards: None System deviations from the referenced NFPA Standards are: None (signed) for Central Station or alarm Service Company Title date Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction) AHJ. Representative Title date 7 Product Line Information - 005220:City Box Transmitter Module. MS-25:Combination DACT/Fire Alarm Control Panel with one 007860: DACT Phone Cord(2 required). SLC loop.Includes main circuit board with display,transformer. IPDACT 2/211D, IPDACT Internet Monitoring Module: backbox with door, manual, and required screws, cables, key, Connects to primary and secondary DACT telephone output etc. Red, 120 VAC. ports for internet communications over customer provided eth- MS-25E:Same as MS-25,but operates from 220/240 VAC. ernet internet connection. Requires compatible Teldat . VisorALARM Central Station Receiver. Can use DHCP or MS-25C: Same as MS-25, but listed for Canadian applica- static IP. (See DF-60407 or DF-52424 for more information.) tions.For details on the Canadian version,see DF-60704. IPSPLT: Y-adaptor option allows connection of both panel HONEYWELL FIRE SYSTEMS DEVICES dialer outputs to one-IPDACT-2/2UD cable input. HFS-P: Honeywell Fire Systems addressable photoelectric IPENC: External mounting enclosure-consisting of mounting smoke detector.Includes base. bracket IPBRKT, and screws.When using the supplied phone HFS-PT: Honeywell Fire Systems addressable photoelectric cables,enclosure must be mounted within 6"(15.24 cm)of the smoke detector with thermal sensor.Includes base. FACP. Red. HFS-T: Honeywell Fire Systems addressable fixed tempera- Wiring Requirements ture heat detector.Includes base. HFS-MM: Honeywell Fire Systems addressable Mini-Monitor While shielded wire is not required, it is recommended that all module for normally open contact devices. SLC wiring be twisted-pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. HFS-MR:Honeywell Fire Systems addressable relay module. HFS-D: Honeywell Fire Systems addressable photoelectric duct smoke detector.Includes detector. FIRE•LITE EQUIVALENT DEVICES BG-12LX:Addressable dual-action manual pull station. SD355:Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detec- • tor with thermal sensor. H355: Fast-response,low-profile heat detector. D355PL: InnovairFlex low-flow non-relay duct-detector hous- ing;includes SD355R. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts,which operate as a DPDT switch. 1300:This module isolates the SLC loop from short circuit con- ditions COMPATIBLE ANNUNCIATORS ANN-80(-W): Remote LCD annunciator mimics the informa- tion displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is red; order-W version for white;see DF-52417.) ANN-SB8OKIT R: Red surface mount backbox with angled wedge. ANN-SB8OKIT W: White surface mount backbox with angled wedge. MISCELLANEOUS SB-I/O:Surface-mount backbox for the BG-12LX,plastic. BG12TR: Optional trim ring for semi-flush mounting the pull- station. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F:Battery box,houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG 120F:Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional BB- 55F for mounting. BAT Series:Batteries. See DF-52397. DF-60702:A1•9/16/2011—Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Temperature and Humidity Ranges • Intelligent Signalling Line Circuits 1 This system meets NFPA requirements for operation at 0 — • Addressable device capacity 25 49°C/32— 120°F and at a relative humidity 93% ± 2% RH • Programmable software zones 5 (noncondensing) at 32°C ±2°C (90°F± 3°F). However, the useful life of the system's standby batteries and the electronic • Annunciators 2 components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that Electrical Specifications -this system and its peripherals be installed in an environment AC Power: MS 25: 120 VAC, 60 Hz, 1.5 A. MS 25E: 230 with a normal room temperature of 15—27°C/60—80°F. • VAC, 50/60 Hz, 0.75 A. AC wire size is minimum 14 AWG (2.00 mm2)with 600 V insulation. Nonpower-limited,super- Agency Listings and Approvals vised. The listings and approvals below apply to the basic MS-25(E) • Battery: Charging capacity 7-33 AH (18 AH for ULC appli- control panel. In some cases, certain modules may not be cations). MS-25 cabinet holds maximum of two 7 AH batter- listed by certain approval agencies, or listing may be in pro- ies. Larger batteries require a separate battery cabinet, cess.Consult factory for latest listing status. such as the BB-26 or BB-55F. • UL Listed:S624 • Communication Loop:Supervised and power-limited. • CSFM:7165-0075:0217 • Notification Appliance Circuits: For the ULC-listed version,see DN-60641. —Terminal Strip provides connections for two NACs,Style Y (Class B). NFPA Standards —Maximum signaling current:2.0 A. —End-of-Line Resistor: 4.7 kOhm, 1/2 watt (P/N 71252 UL The MS-25(E)complies with the following NFPA 72 Fire Alarm listed)for Style Y(Class B)NAC.Refer to the MS-25 man— ual for listed compatible devices. —LOCAL (Automatic, Manual, Waterflow and Sprinkler • Standby Current: 135 mA Supervisory). • Alarm Current 220 mA —AUXILIARY(Automatic, Manual and Waterflow)(requires 5220 module). • Aux Power Circuits: 1.OA @ 24 VDC per circuit, power- —REMOTE STATION (Automatic, Manual, Waterflow and limited Sprinkler Supervisory) (Where a DACT is not accepted, • Two Programmable Relays and One Fixed Trouble the alarm, trouble and supervisory relays may be con- Relay: nected to UL 864 listed transmitters. • —Contact rating:2.5 A @ 24 VDC(resistive). —PROPRIETARY(Automatic,Manual and Waterflow). —Form-C relays,nonpower-limited,nonsupervised. —CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). Physical Specifications • Dimensions: 15.2"H (38.42 cm)x 12.75"W(32.39 cm)x 3.4"D(8.57 cm) • Weight: 11.5 lbs.(5.2 kg) • Color: Red Fire•Lite® Alarms®, JumpStart®, and System Sensor® are registered trademarks of Honeywell International Inc. X011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. 'rr�rrr We cannot cover all specific applications or anticipate all requirements. GEflTIIFIE.D 8ICINEEIIIV 8 MAININTIMIN All specifications are subject to change without notice. onimmiimoromm QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 4 of 4—DF-60702:A1•9/16/2011 Panel Capabilities Cabinet Specifications The IPGSM-4G is compatible with fire panels that use the Dimensions:14.875°H x 12.75°W x 3.0°D(37.8 cm H x 32.4 Contact ID communications format as described in the SIA cm W x 7.6 cm D). DC-05 standard. Color: Red. AlarmNet Shipping Specifications Honeywell's AlarmNet has been the nationwide leader in Weight:5.3 lbs.(6.94 kg). alarm communications technology since 1986.A reliable alter- Dimensions: 15.625° H x 13.79°W x 9.25° D (39.7 cm H x native for the transmission of alarm signals, our radio network 3.49 cm W x 23.9 cm D) provides extensive coverage in the United States and Canada. AlarmNet Network Control center processes signals from pow- erful servers in multiple locations equipped with 24/7 infra- Temperature and Humidity Ranges structure support.The AlarmNet network consist of redundant This system meets NFPA requirements for operation at 0 - hardware servers,hot back-up databases and generators with 49°C/32-120°F and at a relative humidity 93%±2%RH(non battery back-up at all locations to ensure continuity of service. condensing at 32°C±2°C (90°F±3°F). However, the useful Signals from Alarm-Net are transmitted to the central station's life of the system's standby batteries and the electronic corn- receivers using multiple communications paths consisting of ponents may be adversely affected by extreme temperature the Internet, radio network or toll-free POTS service. ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with Installation Requirements a normal room temperature of 15-27°C/60-80°F. UL COMPLIANCE Product Line Information To meet UL864/NFPA,ensure the following: IPGSM-4G: Internet and Digital Cellular Fire Alarm Communi- • IPGSM-4G must be installed in accordance with NFPA cator Panel. Includes red cabinet with ademco key and lock, (National Fire Protection Association)standards 70 and 72. wall outlet box,Dialer Capture Module,iGSM Communications • IPGSM-4G must be mounted in the same room and within Module, antenna & mounting adapter, PowerBoostl power 20 feet of the fire panel. supply, LED display board, transformer, manual, & required • IPGSM-4G, and all equipment used for the IP connection screws,cables,etc. (such as the router, hub, modem,etc.)shall be listed, must GSM-ANT3DB:3db gain external/remote antenna. be powered from an un-switched branch circuit,and be pro- 7626-50HC:50 ft.antenna cable, low loss. vided with appropriate standby power. 7626-25HC:25 ft.antenna cable,low loss. • IPGSM-4G must use the 7AH battery(not supplied)to pro- WA7626-CA:SNA to N Adapter. vide 24-hour backup capability. 7720P: IPGSM-4G hand held programmer. Electrical Specifications HPTCOVER:Plug in transformer box for IPGSM communicator. BAT-1270:Battery 12 Volts,7 AH,sealed. Transformer: —Primary 120VAC,60Hz,0.5A. Agency Listings and Approvals —Secondary: 18VDC,50VA. The listings and approvals below apply to the basic IPGSM-4G Battery: communicator panel.In some cases,certain modules may not be —One 12 V 7.0 AH lead acid battery(not supplied). listed by certain approval agencies,or listing may be in process. —Battery charging current: 1 Amp maximum. Consult factory for latest listing status. —Battery discharge current: Standby 230mA, Active UL Listed:S789. 950mA. CSFM:7300-1645:0199. FDNY:COA#6150. This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. ©2013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Automation and Control Solutions Honeywell Honeywell 12 Clintonville Road 1(877)HPP-POWR Northford, CT 06472-1610 hpp_techsery@honeywell.com www.honeywellpower.com DH-60769:B June 2013 Made in the U.S.A. ISO ®U.S.Registered Trademark e.2013 Honeywell International Inc. MICIMFYK` ME Page 2of2 QUALITY SYSTEMS ANN-BUS DEVICE ADDRESSING After calculating the total worst case current draw, the following Each ANN-BUS device requires a unique address(ID Number) table specifies the maximum distance the modules can be in order to communicate with the FACP.A maximum of 8 devices located from the FACP on a single wire run. The table ensures can be connected to the FACP ANN-BUS communication circuit. 6.0 volts of line drop maximum. In general,the wire length is lirn- See the FACP manual for more information. ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. WIRE REQUIREMENTS:COMMUNICATIONS CIRCUIT These cases are marked in the chart with an asterisk(*). Maxi- The ANN-80 connects to the FACP ANN-BUS communications mum length can never be more than 6,000 feet (1,800 m), circuit. To determine the type of wire and the maximum wiring regardless of gauge used. See table below. distance that can be used with FACP ANN-BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus.The total worst • 14 to 18 AWG (0.75-2.08 mm2)wire for 24 VDC power cir- case current draw is calculated by adding the individual worst cult is acceptable. Power wire distance limitation is set by 1.2 case currents for each module. volt maximum line drop form source to end of circuit. NOTE: For total worst case current draw on a single ANN-BUS • All connections are power-limited and supervised. refer to appropriate FACP manual • A maximum of eight ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case 22 Gauge 18 Gauge 16 Gauge 14 Gauge Current Draw(amps) 0.100 1,852 ft. 4,688 ft. *6,000 ft. *6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 517 ft. 1,563 ft. 2,488 ft. 3,937 ft. • 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000(max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION ORDERING OPTIONS: The following figure illustrates the wiring between the FACP and ANN-80:Red 80 character LCD Annunciator. ANN-BUS devices. ANN-80-W:White,80 character LCD Annunciator. ANN-BUS and power ANN-SB8OKIT R: Red surface mount backbox with angled wiring are supervised wedge. and power-limited. ANN-SB8OKIT W: White surface mount backbox with angled ® 0 L1 a wedge. TB1 02O J 9t 4 3 2 1 ANN-BUS Device EeToTtru 0 MS-9050UD TB3 0 Q Q Co GI 0 rI fI 1 2 3 4 5 6 7 8 FACP Wiring to ANN-BUS Device FireLite®Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. -' " ____ n CE is-r i v.s E n We cannot cover all specific applications or anticipate all requirements. ' ENSINEBIINi S MANIFAL1URIN: All specifications are subject to change without notice. •" r"�' QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—df-52417:c•05/22/09 Manual stations shall connect with two wires to one of the con- BG12TR: Optional trim ring. trot panel SLC loops. The manual station shall, on command 17003: Keys,set of two. from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Agency Listings and Approvals In some cases,certain modules or applications may not be Product Line Information listed by certain approval agencies,or listing may be in pro- BG-12LX: Dual-action addressable pull station. Includes key cess.Consult factory for latest listing status. locking feature. • UL Listed:S711 SB-10: Surface backbox;metal. • MEA:67-02-E SB-I/O: Surface backbox;plastic. CSFM:7150-0075:184 • FM Approved .c 47 9 r ` i i .. if A t =' • 1' v .� �r o Detail of -) R . �� ,5 BREAKAWAY TAB* .�. ` x� t g e 1415 0 1 ADDRESS 0 1 't ' �' 13 2 I;, 2 ,spa ? az w 12 [. 3illCI f 11 �/ 4 4 ; -i _` • 5 LOOK � 5 Back of station t. ,o without door a , 8 , Terminal Connections: — 1 SLC(-);2 SLC(+) ^ ' . i� , i o o' LED c `iz `;;' ' ROTARY DECIMAL SWITCHES Remove tab to select addresses above 99. :)-- I: '6°1'414:rep t� jii 'i n 1 -..--------=— — 1 cti,s=____ _61.1.14'. 7?1.11.11' 11'1'1111 ° Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Patented: U.S.Patent No.D428,351;6,380,846;6,314,772;6,632,108. Flre-Lite is a registered trademark of Honeywell International Inc. LEXANO is a registered trademark of GE Plastics, a subsidiary of General Electric Company. ©2008 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'S® ®®1 This document is not intended to be used for installation purposes. w:....... We try to keep our product information up-to-date and accurate. _ rrrrr CERTIFIED We cannot cover all specific applications or anticipate all requirements. ,...,......... 911CIK=SMANIFICT1IIr1C All specifications are subject to change without notice. �""" ""o QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—DF-52013:B•10/20/2008 -- • LED latches steady to indicate alarm on command from 3 1415 0 1 ADDRESS 0 1 control panel. 132 2 The MMF-302 Interface Module is intended for use in intelli- 3 12 � 3 LOOP 0.34 gent, addressable systems, where the individual address of 11 %v// 4 each module is selected using built-in rotary switches. This 105 5 module allows intelligent panels to interface and monitor two- 9 8 7 6 - 9 8 7 6 wire conventional smoke detectors.It transmits the status(nor-- - TENS - ONES---=- mal,open,or alarm)of one full zone of conventional detectors r1 0 back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 can be used to replace M302 modules in existing systems. I-- LJ.J U MMF-302APPLICATIONS O W CI _ _, , Use the MMF-302 to monitor a zone of two-wire smoke detec- Ca tors.The monitored circuit may be wired as an NFPA Style B (Class B)or Style D(Class A)Initiating Device Circuit.A 3.9 K ohm End-of-Line Resistor(provided)terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- 1 I 11 tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. The MMF-301 Mini Monitor Module can be installed in a sin- gle-gang junction directly behind the monitored unit. Its small MMF-302 OPERATION size and light weight allow it to be installed without rigid mount- Each MMF-302 uses one of the available module addresses ing. The MMF-301 is intended for use in intelligent, two-wire on an SLC loop. It responds to regular polls from the control systems where the individual address of each module is panel and reports its type and the status (open/normaVshort) selected using rotary switches. It provides a two-wire initiating of its Initiating Device Circuit(IDC). A flashing LED indicates device circuit for normally-open-contact fire alarm devices. that the module is in communication with the control panel. The MMF-301 can be used to replace M301 modules in exist- The LED latches steady on alarm (subject to current limita- ing systems. tions on the loop). MMF-301 APPLICATIONS MMF-302 SPECIFICATIONS Use to monitor a single device or a zone of four-wire smoke Nominal operating voltage: 15 to 32 VDC. detectors,manual fire alarm pull stations,waterflow devices,or other normally-open dry-contact devices. May also be used to Maximum current draw: 5.1 mA(LED on). monitor normally-open supervisory devices with special super- Maximum IDC wiring resistance: 25 ohms. visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B(Class B)Initiating Device Circuit. Maximum operating current: 270µA(LED flashing). A 47K ohm End-of-Line Resistor(provided)terminates the dr- EOL resistance: 3.9K ohms. cult. External supply voltage(between Terminals T3 and T4): MMF-301 OPERATION DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms Each MMF-301 uses one of the available module addresses maximum.Current:90 mA per module maximum. on an SLC loop. It responds to regular polls from the control Temperature range: 32°F to 120°F(0°C to 49°C). panel and reports its type and the status (open/normaVshort) Humidity range: 10%to 93%noncondensing. of its Initiating Device Circuit(IDC). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x MMF-301 SPECIFICATIONS 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Nominal operating voltage: 15 to 32 VDC. 2.125"(5.398 cm)deep box. Maximum operating current: 375µA. MDF-300 Dual Monitor Module Maximum IDC wiring resistance: 1,500 ohms. The MDF-300 Dual Monitor Module is intended for use in intel- EOL resistance: 47K ohms. ligent,two-wire systems. It provides two independent two-wire Temperature range: 32°F to 120°F(0°C to 49°C). initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact Humidity range: 10%to 93%noncondensing. fire alarm and supervisory devices. The module has a single Dimensions: 1.3" (3.302 cm) high x 2.75"(6.985 cm)wide x panel-controlled LED. 0.65"(1.651 cm)deep. NOTE: The MDF-300 provides two Class B(Style B)IDC circuits Wire length: 6"(15.24 cm)minimum. ONLY. Class A (Style D) IDC circuits are NOT supported in any application. MMF-302 Interface Module MDF-300 SPECIFICATIONS • Supports compatible two-wire smoke detectors. Normal operating voltage range: 15 to 32 VDC. • Supervises IDC wiring and connection of external power Maximum current draw: 6.4 mA(LED on). source. Maximum operating current: 750µA(LED flashing). • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. Maximum IDC wiring resistance: 1,500 ohms. • Direct-dial entry of address: 01 - 159 on MS-9600 series EOL resistance: 47K ohms. panels,01 -99 on other compatible systems. Temperature range: 32°to 120°F(0°to 49°C). • LED flashes during normal operation. Humidity range: 10%to 93%(non-condensing). Page 2 of 4—df-52121:b•11/13/08 Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125"(5.398 cm)deep. MDF-300 AUTOMATIC ADDRESSING The MDF-300 automatically assigns itself to two addressable points, starting with the original address. For example, if the MDF-300 is set to address_"26", then it will automatically assign itself to addresses"26"and"27". NOTE:"Ones"addresses on the MDF-300 are 0,2,4,6,or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300,MMF-302,and MDF-300 modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box.They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes,ordinances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S2424 • ULC: S3705 (A"suffix models) • FM Approved • CSFM:7300-0075-185 • MEA:72-01-E Product Line Information NOTE:"A"suffix indicates ULC Listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module,miniature. MMF-302(A): Monitor module,two-wire detectors. MDF-300(A): Monitor module,dual,two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual,PN 51309. Architects'/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. df-52121:b•11/13/08—Page3 of 4 • Fire-Lite@ and LiteSpeed® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. c E FST o F 1 E D We cannot cover all specific applications or anticipate all requirements. 91611fIN6 A MANIMOIMM6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 4 of 4—df-52121:b•11/13/08 OPERATION PRODUCT LINE INFORMATION Each SD355(T)uses one of 99 possible addresses on the MS- NOTE:'A"suffix indicates ULC-Listed model. 9200 series and up to 318(159 on each loop)on the MS-9600 SD355: Adressable photoelectric detector; B350LP base Signaling Line Circuit(SLC). It responds to regular polls from included. the system and reports its type and status. The SD355(T)addressable photoelectric sensor's unique uni- SD355A: Sames as SD355 with ULC Listing (B350LPA base polar chamber responds included). p quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to SD355T: Same as SD355 but with thermal element; B350LP 4,000 feet-per-minute (20 m/sec.) without sending an alarm base included. level signal. Because or its unipolar chamber,the SD355(T)is SD35.5TA•Same as SD355T with ULC Listing(B350LPA base approximately two times more responsive than most photo- included). electric sensors.This makes it a more stable detector. B350LP(A): Plug-in detector base. Dimensions: 6.1' (15.5 DETECTOR SENSITIVITY TEST cm). Mounting:4.0• (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5° (8.89 cm) Each detector can have its sensitivity tested (required per octagonal box, or single-gang box.All mounting boxes have a NFPA 72,Chapter 10 on Inspection, Testing and Maintenance) minimum depth of 1.5°(3.81 cm). when installed/connected to a MS-9200 series or MS-9600 B224RB(A): Plug-in System Sensor relay detector base. series addressable fire alarm control panel.The results of the Diameter:6.2°(15.75 cm).Mounting:4.0"(10.16 cm)square sensitivity test can be printed off the MS-9200 series or MS- box with or without plaster ring,4.0"(10.16 cm)octagonal box, 9600 series for record keeping. or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5"(3.81 cm). SPECIFICATIONS B224Bl(A): Plug-in System Sensor isolator detector base. Voltage range: 15-32 VDC(peak). Maximum 25 devices between isolator bases(see DF-52389). Standby current:300NA 24 VDC. Diameter:6.2"(15.75 cm).Mounting:4.0"(10.16 cm)square box with or without plaster ring,4.0"(10.16 cm)octagonal box, LED current:6.5 mA Ce?24 VDC(latched"ON"). or 3.5" (8.89 cm) octagonal box. All mounting boxes have a Air velocity:4,000 ft./min. (20 m/sec.)maximum. minimum depth of 1.5"(3.81 cm). Diameter:6.1"(15.5 cm)installed in B350LP base. B501BH 2(A): Plug-in System Sensor sounder detector base. Diameter:6.0° (15.24 cm). Mounting:4.0" (10.16 cm) Height:2.1"(5.33 cm)installed in B350LP base. square box with or without plaster ring. Mounting box has a Weight:3.6 oz.(102 g). minimum depth of 1.5°(3.81 cm). Operating temperature range: for SD355(A): 0°C to 49°C B501BHT2(A): Plug-in System Sensor temporal tone (32°F to 120°F); for SD355T(A):0°C to 38°C(32°F to 100°F). sounder detector base. Temperature:0°C-49°C(32°F-120°F). ACCESSORIES: Relative humidity: 10%-93%,non-condensing. RA400Z(A): Remote LED annunciator.3-32 VDC.Mounts to • a U.S. single-gang electrical box. For use with B501(A) and LISTINGS B350LP(A)bases only. Listings and approvals below apply to the SD355(A) and SMK400E: Surface mounting kit provides for entry of surface SD355T(A) detectors. In some cases, certain modules may wiring conduit. For use with B501(A)base only. not be listed by certain approval agencies,or listing may be in RMK400: Recessed mounting kit. For use with B501(A)base process.Consult factory for latest listing status. only. • UL Listed,file S1059. M02-04-00:Test magnet. • ULC Listed,file S6963. M02-09-00:Test magnet with telescoping handle. • CSFM approved:file 7272-0075:194. XR2B:Detector removal tool.Allows installation and/or removal • MEA approved:file 243-02-E. of detector heads from bases in high ceiling applications. • FM approved. XP-4: Extension pole for XR2B. Comes in three 5-foot(1.524 m)sections. T55-127-010:Detector removal tool without pole. BCK-200B:Black detector covers,box of 10. WCK-200B:White detector covers,box of 10. FlashScan® registered trademark of Honeywell International Inc. Bay- blend®is a registered trademark of Bayer Corporation. 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'S® 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T I F7 E O We cannot cover all specific applications or anticipate all requirements. ENCINEWNJ 8 MAN9FAC10AINC All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2-df-52384:a1•05/8/09 SpectrAlert Advance Specifications Architect/Engineer Specifications General -- SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync-Circuit-Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 175 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings including 15,15/75,30, 75,95,110,115,135,150,177,185. - Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at • 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounderThe horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 411/18x 411/18x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) K Series Operating Temperature -40°F to 151°F(-40°C to 66°C) Humidity Range 1 oto 93%non-condensing(indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR1 Operating Voltage Rangel 8 to 175 V(12V nominal)or 16 to 33 V(24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Wall mount dimensions(including lens) 5.61 x 4.7W x 2.5D(142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61x4.7'Wx1.3'D(142 mm Lx 119mmWx33mmD) Wail-mount back box skirt dimensions(BBS-2,BBSW-2) 5.91 x 5.0W x 2.2"D(151 mm L x 128 mm W x 56 mm 0) Ceiling-mount back box skirt dimensions(BBSC-2,BBSCW-2) 7.1`diameter x 2.25-high(180 mm diameter x 57 mm high) Wall-mount weatherproof back box dimensions(SA-WBB) 5.71 x 5.1-W x 2.0-D(145 mm L x 1.30 mm W x 51 mm D) Ceiling-mount weatherproof back box dimensions(SA-WBBC) 7.1-diameter x 2.0"high(180 mm diameter x 51 mm high) Wall-mount trim ring dimensions(TR-HS,TRW-HS) 5.71 x 4.812-W x 0.35"D(146 mm L x 122W mm x 9 D mm) Ceiling-mount trim ring dimensions(TRC-HS,TRCW-HS) 6.9"diameter x 0.35 high(176 mm diameter x 9 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time varying power source that is used on some power supply and panel outputs. 2.P S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-005 UL Current Draw Data UL Max.Strobe Current Draw(mA HMS) UL,Max..Horn'Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15* 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75* 142 - 148 77 81 Temporal Medium 44 49 58 69 - 30* NA NA 94 96 Temporal Low 38 44 44 48 75* NA NA 158 153 Non-temporal High 57 56 69 75 95* NA _ NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-wire Horn/Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 • 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 . UL Max.Current Draw(mA RMS),2-wire Horn/Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299" Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating . Horn Tones and Sound Output Data For K series products used at low temperatures,listed candela Horn and Horn/Strobe Output(dBA) ratings must be reduced in accordance with this table. 8-17.5 16-33 24 Volt Nominal Strobe Output(cd) Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at-40°F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32°F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non-temporal High 82 82 88 88 93 92 100 100 95 70 5 Non-temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non-temporal Low 75 75 81 81 88 84 96 92 • 115 115 7t Coded High 82 82 88 88 93 92 101 101 135 135 8t Coded Medium 78 78 85 85 90 90 97 98 150' 150 9t Coded Low 75 75 81 81 88 85 96 92 177 177 i • tSettings 7,8,and 9 are not available on 2-wire horn/strobe. 185 185 R05-295-005 SpectrAlert Advance Dimensions j.—a.r 2 s—. Dia. >,�P Dia. 11111 11111 I,. 1*4.I ile 11-11 1� ���,i, l � _ , J_ J 1I!!L6IP - . ,,(( :/j,, � :Iji\ Wall-mount horn/strobes Ceiling-mount horn/strobes 7.1- 2.251 '2.0- Dia 5.05" 2.23+1 Dia. I r `r H e o e o 5.98 R. [ ' 1 c ® 6.2" tIIIIII O id), �.—. ----5.1" I,i 4 illk' -:!) Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model' Description Wall Horn/Strobes Ceiling Horn/Strobes(cont d.) P2R*1- 2-wire Horn/Strobe,Standard cd*,Red PC4W 4-wire Horn/Strobe,Standard cd,White - P2RH* 2-wire Horn/Strobe,High cd,Red PC4WH 4-wire Horn/Strobe,High cd,White P2RK*° 2-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P2RHK° 2-wire Horn/Strobe,High cd,Red,Outdoor SCR* Strobe,Standard cd,Red P2W* 2-wire Horn/Strobe,Standard cd,White SCRH* Strobe,High cd,Red P2WH* 2-wire Horn/Strobe,High cd,White SCRK° Strobe,Standard cd,Red,Outdoor P4R* 4-wire Horn/Strobe,Standard cd,Red SCRHK° Strobe,High cd,Red,Outdoor P4RH* 4-wire Horn/Strobe,High cd,Red SCW*t Strobe,Standard cd,White P4RK° 4-wire Horn/Strobe,Standard cd,Red,Outdoor SCWH*t Strobe,High cd,White P4RHK" 4-wire Horn/Strobe,High cd,Red,Outdoor Horns P4W* 4-wire Horn/Strobe,Standard cd,White HR Horn,Red P4WH" 4-wire Horn/Strobe,High cd,White HRK° Horn,Red,Outdoor Wall Strobes HW Horn,White SR*t Strobe,Standard cd,Red Accessories SRH*t Strobe,High cd,Red BBS-2 Back Box Skirt,Wall,Red SRK" Strobe,Standard cd,Red,Outdoor BBSW-2 Back Box Skirt,Wall,White SRHK Strobe,High cd,Red,Outdoor BBSC-2 Back Box Skirt,Ceiling,Red SW* Strobe,Standard cd,White BBSCW-2 Back Box Skirt,Ceiling,White SWH* Strobe,High cd,White TR-HS Trim Ring,Wall,Red Ceiling Horn/Strobes TRW-HS Trim Ring,Wall White • PC2R" 2-wire Horn/Strobe,Standard cd,Red TRC-HS Trim Ring,Ceiling,Red PC2RH* 2-wire Horn/Strobe,High cd,Red TRCW-HS Trim Ring,Ceiling,White PC2RK° 2-wire Horn/Strobe,Standard cd,Red,Outdoor Notes: PC2RHK° 2-wire Horn/Strobe,High cd,Red,Outdoor *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g., PC2W*t 2-wire Horn/Strobe,Standard cd,White P2R-P. t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. PC2WH*t 2-wire Horn/Strobe,High cd,White #"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 PC4R 4-wire Horn/Strobe,Standard cd,Red candela settings."High cd',"refers to strobes that include 135,150,177,and 185 PC4RH 4-wire Horn/Strobe,High cd,Red candela settings. PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor All outdoor units ending in"K"include a weatherproof back box. PC4RHK° 4-wire Horn/Strobe,High cd,Red,Outdoor n Add"-R"to model number for weatherproof replacement device(no back box • included). • 02008 System Sensor. //rill"' 3825 Ohio Avenue•St.Charles,IL 60174 Product speafications subject to change wahcut notice.Mot systemsensoccom for current prodSORuct duct inducing information,indug the latest version of this data sheet. ' Phone:800-SENSOR2•Fax:630-377-6495 805-039S-005.8/08•#2018