Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (8)
RECEIVED MAY 022013 CITY OF TIGARD STRUCTURAL CALCULATION§LDINGDIVISION FOR ANYTIME FITNESS 16200 SW Pacific Hwy TIGARD, OR 97224 -- ROOF MECHANICAL UNIT REPLACEMENTS -- 0.D pROFE CITY OF TIGARD 0,G I " FR /� Approved..kh1 tAc —[�r •,187 r Conditionally Approved [ ] ti See Letter to:Follow [ ] Attached OR ON a Permit Nu ber:U' -GZ©(3-0O2 ]C, ✓04 g' Address: (02-CO Ns:— a' • % W v° ' 15, 4, . By: j Date: -1E (' . NOR�� EXPIRES: 12/31/14 Approved plan: shall be on job site. OFFICE COPY Contents Details A-B D1 - D2 Gravity Calculations G1 Lateral Calculations L1 -L2 Contact Person: John E Nordling,PE Enclosures El -E9 NORDLING Proj. No.: 13-142 U5C TIGARD GYM STRUCTURAL ENGINEERS, LLC SPECIALTY HEATING&COOLING, INC. 6775 SW 111th.Suite 200•Beaverton OR,97008 Date: APR 2013 By: JEN Sheet No.: COVER .-� _• • .. .,..:�.Y ,_. =+cam--. - .IIP ,,c.. - A- c, 16200 SW -acific Hwy;Tig: 4, .• # ",, , V .. :t .- .=,a.. ;Unit 2 replacement . � � F , r S � r- Unit 1 repia ement is--; r. _ -- . i.= r' replacement _ -�, F r Unit 4 replacement ti r _ t" �,-. r ` 4 IlitIlli A 1 UPI bizovia. ... e • a r e.4 ?te• ~ F L ..'.f MINN■ ie.ii.:. ..,- . ' Google'earth ,r i d^ f.. T�71, (u gLearth• feet meters ly 1 `. E - M • _ ::ale I .. .. raimi ■ 1.. .. . ...‘0 .. ' GY !k W011Jt MrNL Cf ,... V 3) 'iCLsY+6 — ' , �t��.t� ■f fll-4 Pr ! .o 1 f �• % . ; %0 -.V74 * ... . ....... ... . ti . . . 1 1 , , i I I , It r .....iy! tl. 4ve • ® F)Gll l 44 : lF•.KtiaiN A.$ui _ T 1 b tl kG01dp (*fl P %Ner5. >ws04,.. trsix- 490 , c.,0,p PR0,44. ite\V`w lr _ SAS 4. 1�M'1`M AI,�{`..Ito ...= y^�. ��J �N F,4 /b 1/5 - 1 ,187 .• 4 0 OR ON , A•` ✓O 'L4 e 1 5 ,95� \-\4 - A Vied:P. fisAMAANic.M.. '‘) .1 . ti-.1•1,AizesAtOr I EXPIRES: 12/31/14 I u5cNORDLING Proj. No.: 13-142 STRUCTURAL TIGARD GYM ENGINEERS, LL SPECIALTY HEATING&COOLING,INC. 6775 SW 111th,Suite 200•Beaverton OR,97008 Date:APR 2013 By:JEN Sheet No.: VA (4) GALVANIZED STEEL BRACKETS W/ (4) "10 x I/?' TEK SCREWS TO (E) CURB 4 (4) "10 x 1/2' TEK SCREWS TO UNIT BASE RAIL p (4) "10 SCREWS—�� (4) "10 SCREWS ■—MECHANICAL UNIT II *12 SCREWS 612' o/c ALL SIDES BASE RAIL R^ � A--STEEL BRACKET l —ADAPTER CURB 9 VERIFY (E) CURB BEARS ON A MINIMUM OF (3) (E) ROOF TRUSSES ' �CE) CURB (E) ROOF TRUSS /' \ \ \ I I / \ 11:0 PROFFs�/O GINe 12,187r l EGON .4 Dm DETAIL 5 OyN E. NOR°-I EXPIRES: 12/31/14 tl5kNORDLING Proj. No.: 13-142 , STRUCTURAL TIGARD GYM ENGINEERS, LLC SPECIALTY HEATING&COOLING,INC. 6775 SW 111th.Suite 200•Beaverton OR.97008 Date:APR 2013 By:JEN Sheet No.: D2 • GCO%p mss...:... :.......... .... )., -� 1 *A15 .H.1../ 1, Kik- , fa je.. lea.s.4.6 wrk.c,1..T JCS 4- (E\ t '�440 . a 0�r-� N. . 7;j -n C(NI ctirA'x. 235 ) - c.')1 U-S a-5 5.rfhAJC P . ' 14. 4+at - 49--l;.y l b5 y ir oto *--1-141,5 "" 1--`k 0 '1/4) .----"""Thi .__ J I M ctrl- 1�(tft.ci*LA ZdtA�. 24441 :kNa S*y„ ... O j►isr I,10(4. r :�wtk;a,= �,f tr 2 t}4 . . . '` � ` 31►o�iug/� w , G/0044 3 o M,,,a,„4.4. 14s eliA(1 c *t•o° " 45 4,sT-1.I/ h .z., � (..1tti.Cki I * — G 1u- t ststvot... r=4 .-04..... ..... "jiINS 3 -Dim 'l ws.cir' -6 - - NORDLING Pro]. No.: 13-142 5 STRUCTURAL TIGARD GYM ENGINEERS, LLC SPECIALTY HEATING&COOLING,INC. 6775 SW 111th,Suite 200 Beaverton OR,97008 Date:APR 2013 By:JEN Sheet No.: ‘ USGS Earthquake Hazards Program • 2005 ASCE 7 Standard Location 45°24' 10.15"N Ss and SI=Mapped Spectral Acceleration Values 122°47'38.15"W 16200 SW Pacific Hwy,Tigard,OR 97224 Ground Motion Ss 0.914 Si 0.332 Occupancy Category II Site Coefficients Fa 1.13 Site Class 1.74 Importance Factor 1.00 Height of Structure 20.0 ft SMS Fa* Ss 1.037 SMi F, * Si 0.576 Design Category(SDC) D SDS (2/3)SMS 0.691 SDI (2/3)SM1 0.384 Air Side HVAC Eq= 0.274W+ 0.2 SDS W ap 2.50 Rp 6.00 W :Weight of Unit F, 0.4 apRSDS •j"Irl+2 h l•W _ l J p P z= 20.0 ft ASD Fp= 0.35 WP->* 0.7 0.242 z= 24.0 ft Fp= 0.39 Wp->* 0.7 0.274 FP MIN= 0.3 SDS IP WP 0.207 Wp->* 0.7 0.145 FP MAX= 1.6 SDS IP WP = 1.11 Wp->* 0.7 0.774 NORDLING Proj. No.: 13-142 " 111C TIGARD GYM STRUCTURL ENGINEERS,A LLC SPECIALTY HEATING&COOLING,INC. 6775 SW 111th,Suite 200 Beaverton OR.97008 Date:APR 2013 By:JEN Sheet No.: L1 t<e vEQ 114 lbs '�_ W: 725 lbs Height 36" Weight 725 lbs Length 72" Width 45" Curb+A 36" VEQ= 0.274* 725 lbs +0.2* 0.691 * 725 lbs = 1991bs+100 lbs vE Q 221 lbs T= 199 lbs * (36" +36"/2)/45" + 100 lbs/2 C: 95 lbs - 0.6* 725 lbs/2 = 71 lbs Net Uplift V= 199 lbs (4) STEEL BRACKETS W/ (4) "10 x 1/2' TEK SCREWS TO ADAPTER 4 (4) "10 x 1/2" TEK SCREWS TO UNIT BASE RAIL "12 19l2" o/c SCREWS FROM ADAPTER TO (E) ROOF CURB BELOW. _ok_ NORDLING Proj. No.: 13-142 tit5c TIGARD GYM STRUCTURAL ENGINEERS, LLC SPECIALTY HEATING&COOLING,INC. 6775 SW 111th.Suite 200•Beaverton OR,97008 Date:APR 2013 By:JEN Sheet No.: L2 YCC042A3SF1A Library Service Literature Product Section Unitary Product Rooftop Air Conditioning Model YCC Literature Type Service Facts • Sequence 1A S ER V/I CE FACTS Date File No. February AA 2188 Supersedes CONTAINS WIRING AND SERVICE INFORMATION Gas/Electric Rooftop Since The Trans Company has a policy of continuous to product o sand°es nwit without no right h change all Models: YCC042A3LOAA, specifications and mat witfwut malice.The installation and servicing of the equipment referred to in this booklet should be done by qualified,experienced technicians. ULOAA, UHOAA IMPORTANT—This document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. PRODUCT SPECIFICATIONS OPTIONAL EQUIPMENT MODEL YCCO42A3 MODEL YCC042A3 Model/Comp Description RATED VOLTS/PH/HZ 208-230/3/60 OUTDOOR PAN{Coati AY28X092 Thermostat-Heat/Cad J.RAMOS Type Drive/No.Speeds Direct/2 BAYCURSO24A Roof Mounting Curb A R ICOOL1N01m No.Motor—HP 1-.33 BAYDMPRO32A 0-25%Manuel Outside Air BTUH 41.0 Motor Speed R.P.M. 1090 BAYECON045A Downflow Economizer Indoor Air Row(CFMI 1400 Volts/Ph/Hz 208-230/3/80 BAYGAKTOO7 High Guard System Power(KIM) 4.87 Ft Ampa—LR.Amps 2.4-5.0 BAYHAKT007 High Ah Conversion Kit BAYKSKT006 Herd Start Kit EER/SEER IBTU/Wen-Hr.) 8.3/9.1 INDOOR FAN—Type Centrifugal BAYLPKT011 A LP Gas Conversion Kit Noise Rating No. 8.0 Dia.x Width IIn.) 9.031 x 8 BAYNXKT003 NOx Emission Kit RATINGS(HEATINOJe No.Used 1 BAYLPKT01 OA LP Gas Conversion Kit Input BTUH 100000 Drie/Speeds(No.) Direct/2 Capacity BTUH' 77000 No.Motors—HP 1-.33 Temp.Flee—Min./Max,F 40/80 Motor Speed R.P.M. 1075 Type ofGesm Natural Volts/Ph/Hz 208-230/3/60 POWER CONNS.—V/Ph/Hz 208-230/3/60 F.L Amps—LR.Amps 4.08.8— Min.8rch.Cr.Ampacity 23 COMBUSTION FAN—Tip. Centrifuge Fuse Size—Max.(Amps) 35 No.Used 1 Drive—Speeds Direct-1 COMPRESSOR Copeland Motor .d{RPM) 000 No. Volts/Ph/Hz 206-230/3/ 6 0 ANA R N I N G Vow/Ph/Hr 206-230/3/60 FL Amps .42 R.L.Artge—L.R.Arnim 12.8-74.0 RLTER—Ftrrdshsd7 No OUTDOOR COQ—Type Plate Fin Type Recommended Disposable SAFETY NOTICE Rows/F.P.I. 2/18 No.of Filters Used 2 Face Area Mo.Ft.) 7.29 THIS INFORMATION IS INTENDED FOR USE BY INDI- Tube Size(In.) .375 Fits Sat 18x 25 x 1 VIDUALS POSSESSING ADEQUATE BACKGROUNDS REFRIGERANT OF ELECTRICAL AND MECHANICAL EXPERIENCE.. INDOOR COIL—Type Rate Fin Charge RN.of R-2214 5.4 vO ANY ATTEMPT TO REPAIR A CENTRAL AIR CONDI- Ro /F.P.I. 2/15 TIONING PRODUCT MAY RESULT IN PERSONAL Face Ana(Sq.Ft.) 4.58 OAS PIPE SIZE NO .75 INJURY AND/OR PROPERTY DAMAGE.THE MANU- FACTURER Size(In.) .375 DIMENSIONS H x W x D FACTURER OR SELLER CANNOT BE RESPONSIBLE amC)xtvot Capillary Crated IO 34.Ox68.5x49.0 FOR THE INTERPRETATION OF THIS INFORMATION, Refrigerant NOR CAN IT ASSUME ANY LIABILITY IN CONNEC- Dnin Conn.Size(In.) %'NPT Uncrated See Outline Drawing TION WITH ITS USE. Duct Connections Se•Ouline l Al CAUTION OUTDOOR FAN—Type Propeller Shipping Ilbs.)!NN ILbs.l /490 No.Used/Dia.(In.) 1/20/20 ID Capacity rated in accordance with A.R.I.Standard 210.Noise rated in accordance with A.R.I.Standard 270. col!.?.Standard rating conditions are:e0 0.B.67 W.B..merino air to indoor coil.95 0.9.entering air to outdoor ALL GROUNDING T rn , on AN models are American Gas Association Certified.Limit settings and rating data wars established and approved ALL PARTS OF THIS PRODUCT CAPABLE OF CON- C) under laboratory test conditions using American National Standards Institute Standards.Ratings shown an for DUCTING ELECTRICAL CURRENT ARE GROUNDED. —I elevations up to 2000 feet.For elevations above 2000 feet.ratings should be reduced at the rate of 4%for each IF GROUNDING WIRES, SCREWS, STRAPS, CLIPS, SJ 1000 feet above sea bevel. NUTS OR WASHERS USED TO COMPLETE A PATH TO C) a Convertible to LPG with orifice change. GROUND ARE REMOVED FOR SERVICE,THEY MUST BE RETURNED TO THEIR ORIGINAL POSITION AND 5'This value is approximate.For mots precise value;see unit nameplate and service instructions. PROPERLY FASTENED. S Based on U.5 Government Standard tests. -- A DANGER ri r- DISCONNECT �Y`I ! , y ..J r,. POWER BEFORE SERVICING 4 ©American Standard Inc.1998 Page G-225-007 Date: Apr 11 2013 Job : TIGARD GYM Customer: Address: PORTLAND/HILLSBORO, OR Mechanical Contractor: SPECIALTY HEATING Submitted By: GARY MITCHELL FOR AARON MCNALLY RUUDi New t..r Equipment List for Project: TIGARD GYM - Dated: Apr 11 2013 Units Tag No Model No Description 3 ton, 13 SEER, R410A Commercial Package Gas Electric RTU - 1 RKNL-A036CK08E Voltage: 208-230/60/3 Factory Options: Standard Accessories For Tag No Field Model Description RTU - 1 AXRF-FBA1 Fresh Air Damper Manual Notes �3 Dimensions,Weight&Clearances Dimensions- Length: 76 - 1/4 Width: 48 -1/16 Height: 35 Weight (lb)-Weigh 543 Clearances (inches)- Front:48 Cond. Coil: 18 Duct Side: 12 • Clearances (inches)- Evap End: 36' Top: 60 Product Submittal#:410b59de-a1d5-4002-aff8-05f7728c2c7f !RUUD Submittal Printed on:4/11/2013 1:30:24 PM For Model:RKNL-A036CK08E In keeping with its policy of continous progress and product improvement,reserves the right to make changes without notice. Gross capacity does not include the effect of motor heat.AHRI rating is'net capacity and includes the effect of fan motor heat.All net capacities also accounts for the effect of motor heat. ASHRAE Weather Data©2009 American Society of Heating,Refrigerating and Air-Conditioning Engineers,Inc.,Atlanta,GA,USA.www.ashrae.org All rights reserved.Used by permission in this pm gram. • • .f P f hf� ),G 1 Unit Drawings for RTU - 1 - RKNL-A036CK08E UNIT DIMENSIONS RKNL/RKPL- 3 TO 5 TON PACKAGE GAS ELECTRIC UNITS [10.6 TO 17.6 kW] MODELS 48%. [1161 mm] 75 ha"m] (191"8 m DISCONNECT BRACKET FLUE OUTLET SUPPLIED W/UNR' SUPPLY GAS /,in'i' 1��11 , ENTRY ♦. ,W \... r 7.l',/s"[13 mm NPT [183 mm] 1688 We1 COMBUSTION kit ,AIR INLET �, i' 24+1." ` 1618 mm, :]4,IIIIIIII / III\11 POWER ENTRY BURNER ACCESS , ,` CONTROL ENTRY CONTROL BOX (457 18']'� t pas ACCESS I1 1 [238 mm] '"i BASE ELECTRICAL ENTRY BASE GAS . ENTRY NO �.N'-. 1 I .; pe lb Oliiii 1 VA ........,•?:._.s lib" ..............% ..................,,." -..._.■ 1846 mm) j - - , 20. �\ • �, �.sot• 1508 mm, ` 2" i q` 134.• siI 151 mmj ` 0.N tek a). i� (367 mini <,":-.............,<:: �[243 mm] 8+ � 1173 n mj 724i —,r�i��F1 11835 m m) BOTTOM VIEW 11121 mm ` �� IP °%.4%;•146% AiA � 2' ( j Designates Metric Conversions 151 mm] es Unit Drawings for RTU - 1 - RKNL-A036CK08E UNIT DIMENSIONS RKNL/RKPL- 3TO 5TON PACKAGE GAS ELECTRIC UNITS [10.6T0 17.6 kW] MODELS . 7-- `I ? L/FILTER /�� ka N ACCESS `\\ ``,_„, . BLOWER fr ........, 313/,8^ =.= ACCESS [792 mm] `` 1 [97 mm] \, 511/e2" \! [136 mm] SUPPLY COVER X1/4" (1937 mm] 481/le" I� 24'/a2 [1221 mm] RETURN COVER 810 mm] CONDENSATE DRAIN 814 [19 mm]NPT FEMALE SUPPLY AND RETURN DIMENSIONS • • RETURN 121/4" . AIR • [311 mm] SUPPLY 191/e 35" AIR [486 mm] [889 mm] I • FILLER • PANEL �[„ 1323/3e 1. T ■ . . . (802 mm) i — 627/3? 1. O O I 0 (174 mm] L 121/4" 191/e" tile '�'{311 mm]�'' 61/2" �— [486 mm] —� [125 mm] PP 761/e [140 mm] [1937 mm) [ ]Designates Metric Conversions '13/4/24 8:23 AM DIMENSIONED AND TOLERENCED PER ANSI Y14.61A-1862 Attn: TRANE Tag: YCX 024F-M YCX 030F-M YCX 036F-M YCX/YCC 042F-M YCX/YCC 036F-M YCC 048F-M DCX 030F-M DCX 036F-M 60 5/8" 11/4" 34" SUPPLY RETURN 221/2" AIR AIR 1 1/2" —� -- 1 1/2" --0 f �- 22 5/8" 27 1/8" 43 7/8" Verify existing curb OD *Verify supply and return openings * Note any changes ' Call with any questions * Fax back if drawing is OK as is • APPROVALS DATE T1ft[: A,LUTTINEN 627/06 TRANE NE woian. Rai G ROOF CURB S.t NAM:: MANNO NO.: Ry: • •.c IS s... CD 756Q TYLER ST 533 30313031 2 • CD ELK RIVER,MN 55330 • •► 2.--r• . 631917851 1 D or •cALe:1:10 ++arr:i i '47 7 '13/4/24 8:23 AM DIMENSIONED AND TOLERENCED PER ANSI Y14.19M-19I2 Attn: RHEEM/McQUAY Tag: RKKA/RKMA A 036-072 MAVERICK MPS 003-005 39 3/4" 261/8" 23 718" ►{ 1 7/8" 22 3/16" RETURN SUPPLY AIR AIR INSULATED/ 429/16° / COVER 2" -1 ././///./ r 70 7/8" I /7/ /,� Verify existing curb OD ` a�� *Verify supply and return openings l/ * Note any changes °�'"°°"' '°""°� * Call with any questions �-^.7 *Fax back if drawing is OK as is 06 CHANGE UNIT DESCRIPTION 9/20/07 APPROVALS DATE TIME: • -, II..n• • : • • • °"'" T.COY 3/18/07 ANUFACTURER SPECS AND ADDED McQUAY GILLKC° RHEEM/McQUAY - lig• Miff: ROOF CURB CD 7oTYLER� FILE 6000 5 • . , . 1 rFa x RIVER tiw s5�3o :a . . ' •. t.•:• . `(8763 391.7190 Ero r: (7633917A51 SCALE 1:16 ercuT:1 of 1 b '13/4/24 8:23 AM .ilC..A.,......a.M.,,... - RV. O6aPION DAR Af.eW® ALM: Tag: 2 RCM OEAWNG 7mM CO 7 WOE W TALL•ADO 2ND WfRY WAR 11 MRS WIG Approval: IS a44' W. i/ 21 1a 4- ,. RETURN AIR RIPPLY AIR - 4 INSULATED COVER IM i EXISTING CURB LAYOUT m sir o TR / r—avor--..r 1 1 7114' F-E 114' t 1211Y RETURN SUPPLY T• J�r ��a7a1r� i \ 4-7 w Imo—a V9'—..1 ? L.---as VP---+1 • K-- .1 rip .n —., 1�OS1�000 CURB SHOWN IS COI STANDARD CONFIGURATION aavARar Nob. CDI RESERVES THE RIGHT TO CHANGE LAYOUT t,M..nWa4N10•,11a1R A QUOTES: 1.1.rADOEDTO OLD CL DD WITHOUT NOTFICATION.IF CURB IS NEEDED IN A wiwyran AAn Anw areDwa _ 17wR �YW Iaa- 2 MATENL1L:1eppow.OALVAIRED STEEL DIFFERENT CONFIGURATION CDI MUST BE NOTFIED L '.. LL aweNETPRDWDED cuRS - I eeo>, �taml�mD 4.1NSIAATION r 11/21/ wm PRIOR TO PLACING AN ORDER. ,n s '*p N I. g2...` ma, a,i gm.1 .a U4)