Loading...
Report (12) r •, ;•• —. •„_ . . A 0. 10 V27, K5.6 O t: LPCB se 0 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS . Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE . — I These Model V27 standard spray sprinklers are designed to produce a i hemispherical spray pattern for standard commercial applications.They are ` available with either standard or quick response bulbs.The design incorporates ' 6,, • state-of-the-art,heat responsive,frangible glass bulb design(standard or quick response)for prompt,precise operation. UPRIGHT 3 PENDENT RECESSED (V2703 AND (V2707 AND PENDENT The die cast frame is more streamlined and attractive than traditional sand cast v2704) v270e) R 27I frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many D angles,reducing assembly effort.This sprinkler is available in various temperature ratings(see chart on page 2)and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon OCT 3 0 2012 which provides up to 3/4"/19mm of adjustments. CITY OFTIGARD . BUILDING DIVISION SPRINKLER OPERATION The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire,the ambient temperature rises causing the liquid in the bulb to expand.When the ambient tem- perature reaches the rated temperature of the sprinkler,the bulb shatters.As a result,the waterway is cleared of all sealing parts and water is discharged towards the deflector.The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE For coverage area and sprinkler placement,refer to NFPA 13 standards. TECHNICAL SPECIFICATIONS Models/S.I.N.:V2703,V2704,V2707,V2708 Style:Pendent,Upright or Recessed Pendent ACCESSORIES Nominal Orifice Size:W/13 mm Installation Wrench: K-Factor:5.6Imp./8.1 S.I.^ • Nominal Thread Size:1h"NPT/15mm Open End:V27 • Max.Working Pressure: Recessed:V27-2 175 psi/1200kPa FM Global Finishes: 250 psi/1725kPa UL Plain brass Factory Hydrostatic Test: • Chrome plated• 100% 500psi/3450kPa ▪ White painted** • Black painted** �� Min.Operating Pressure:7psi/48kPa • Custom painted** �) Temperature Rating:See charts on page 2&3. ��'1 i • Proprietary nickel Teflon*coating** tvii*� MATERIAL SPECIFICATIONS For cabinets and other accessories refer to Upr ight Deflector:Bronze per UNS C22000 separate sheet. r Pendent Deflector:Bronze per UNS C51000 NOTE:Weather resistant recessed escutcheons \--",..:-.... j 91 Bulb:Glass with glycerin solution. available upon request. Bulb Nominal Diameter: • Standard:5.0 mm A For K-Factor when pressure is measured in \ • Quick Response:3.0 mm Bar,multiply S.I.units by 10.0. Load Screw:Bronze per UNS C65100 * Teflon is a registered trademark of Dupont Co. Pip Cap:Bronze per UNS C65100 **UL Listed for corrosion resistance in all Spring:Beryllium nickel configurations. Exaggerated for clarity Seal:Teflon*tape Frame:Die cast brass 65-30 Lodgement Spring:Stainless steel per UNS S30200 JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect _ Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.m2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.c`7L.IIra' REV H I a • A y FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.10 V27, K5.6 . Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE APPROVALS/LISTINGS 1 V2703 V2707 I V2707 V2704 V2708 V2708 Orifice Size(inches) yz° h' 'h" W W W Orifice Size(mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.I." 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Adjustment up to Ni" up to;4°• Approved Temperature Ratings F-/C by Agencyt 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155'F/68°C 135°F/57°C 175°F/79°C 175°F/79°C 155°F/68°C UL 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 13S°F/57°C ULC 175°F/79°C 175°F/79°C 175F179°C 175°F/79°C 175F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 286°F/141°C 286F1141°C 286°F/141°C 360F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 135F/57°C FM It 175°F/79°C 175°F/79°C 155°F/68°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 2ocrFIg3°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68Y 135°F/57°C NYC/MEA x 62-99-E 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286F/141°C 200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C 360°F/182°C 360°F/182°C 135°F/57Y 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68"C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C MIA 1f 7690-0531:112 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 135F/57°C 155°F/68°C 135FI57°C LPCB 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C None None 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C 135°F/57°C 135F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C t75°F/79°C 175°F/79°C 155°F/68 C 155°F/68°C VNIIPO 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 175F/79°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 286°F/141°C 286°F/147°C 200°F/93°C 360°F/182°C 360°F/182°C ZSTZ ZSTX K-ZSTZ K-ZSTX ccc 155°F/68°C 155°F/68°C None 155°F/68°C 155°F/68°C None 200°F/93°C 200F/93°C 200°F/93°C 200F/93°C #Listings and Approvals as of printing.All are approved open,except for areas designated No •For K Factor when pressure is measured in Bar,multiply S.I.units by 10.0 x FM Approved with 1/2"adjustment escutcheon only-quick response • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAUUC COMPANY.ALL RIGHTS RESERVED. IctsuuIid 40.10 2 REV H • w FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.10 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE RATINGS All glass bulbs are rated for temperatures from-67°F/-55°C to those shown in table below. Victaulic Temperature-"F/`C Sprinkler Temperature Part Nominal Temperature Maximum Ambient Classification Identification Rating Temperature Allowed Glass Rolh Color Ordinary 57 1� Orange Ordinary 155 1� Red Intermediate L 79 6S Yellow Intermediate F 93 65 Green High J 286 2107 Blue Extra High# K 3W Purple -# M Open — No Bulb *Standard response only. All are approved open,except for areas designated"No". —150/65 if wax coated. ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number www.victaulic.com jataulid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.O 2012 VICTAULIC COMPANY.AU.RIGHTS RESERVED. REV H 40.10_3 s x FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.10 V27, K5.6 . Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE WARNING A A WARNING • Always read and understand installation,care,and maintenance 4 instructions,supplied with each box of sprinklers, before proceeding with installation of any sprinklers. • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction, must be strictly followed. 43 • Painting, plating,or any re-coating of sprinklers(other than that sup- plied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements,refer to the current National Fire Protection Association document NFPA 25 that describes care and maintenance - of sprinkler systems. In addition,the authority having jurisdiction may have additional maintenance,testing,and inspection requirements that ilar must be followed. mior If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters: P.O. Box 31, Easton,Pennsylvania 18044-0031 USA,Telephone: 001-610-559-3300. • DIMENSIONS Standard Pendent—V2707,V2708 Standard Upright—V2703,V2704 I 1Ye/ r__37mm1 1r 2%'/ �_� 60 mm 1%Y ' I5/8"/ 41 mm � � 60 mm 41 mm 011111 III 1 Mir mm W.Adjustment Recessed—V2707,V2708(drawing not to scale) 2%'/60 mm Max Hole 2"/51 mm • Min.Hole } 1��j/�y� ^yyp _ i �,(�► 1Ye/ 1 ;m ara Ili 11 rom TYPioaI Ceiling Tile I/S I.p li•Ia� 3 m 1 f IT i'Ne/ ,_r� 1Ae'/ 43 mm `rlr� Finished Surface . 30 m •, MAXIMUM RECESS 2%/ 75 mm MAXIMUM EXTENSION www.victaulic.com �y w� VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �y`au'ly 40.104 REV H , FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.10 V27, K5.6 . Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE i DIMENSIONS '/4•Adjustment Recessed—V2707,V2708(drawing not to scale) i 21/60 mm Max.Hole 2'/51 mm Min.Hole irn fm—rn —MO ,M. —M N Typical Ceilin9Tle //Y/ ir1',i,%��A 394'/P7 1 M t m_ WOFinished Surface 24 mm - MAXIMUM RECESS■ 2%'/ 75 mm MAXIMUM EXTENSION AVAILABLE WRENCHES Sprinkler Type V27-2 Recessed V27 Open End V2707,V2708 Pendent yes yes V2707,V2708 Recessed Pendent yes — V2703,V2704 Upright yes yes DISTRIBUTION PATTERNS Models/S.I.N.V2707,V2708 K5.6 standard pendent and recessed pendent distribution patterns—trajectory in .w. 10' • 3.0m •n• r `•`r• •*_• ... �.... ....♦•♦ �• ♦•♦ 8' •�. ♦• '�• ♦♦ 2.4m •♦ •`• 4♦• •`• ♦• 6' •`•• ••• 1. 8m �• ♦♦ •• 4' ♦♦ •` ♦• 1.2m ♦• 44_ 2' •• • 0.6m •4444 . 0 4• 2' 4' 6' 8' 10' 12' 14' 0.6m 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m 7 psi i■••■••• 15 psi 30 psi 48 kPa 103 kPa 207 kPa See notes on next page. i www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iatau'id REV H 40.10_5 FIRE PROT • •:•• •u. k. 40. 10 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE • • DISTRIBUTION PATTERNS Models/S.I.N.V2703,V2704 K5.6 standard upright distribution patterns—trajectory 10' 3.0mI •.. 8' •‘• �••.. 2.4m •• �• •♦ ♦` •♦ 6' 1.8m `• ♦•♦ 4. 4' 44. ♦ 1.2m `• ♦♦♦ ♦♦ ` ♦♦♦ 2' 0.6m • ♦ 1. 0 •• 2' 4' 6' 8' 10' 12' 14' 16' 0.6m 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m 4.9m 7 psi 1S psi 30 psi 48 kPa 103 kPa 207 kPa NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation.Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the perfor- mance of the sprinkler and will void all Listings,Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. • WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. • NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • For complete contact information,visit www.victaulic.com 40.10 2544 REV H UPOATED 01/2012 uctaulid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.10 SPRINKLER SYMBOL DESCRIPTION SYMBOL SIZE MODEL MAKE FINISH SIN TEMP K-FACTOR TOTAL RE:cEIvf hll ® 1/2 REC NACTAULIC CHROME V2708 155 5.6 36 OCT 3 0 2012 TOTAL SPRINKLER HEADS THIS PAGE 36 y( OF TI D t�� g FLOOR PLAN i cn } q � Y x Vie �� y 477,, CITY OF TIGARD � �NOTES •'_�_ ® ; ' ► �� It O- FINAL LOCATION OF SPRINKLER HEADS MAY VARY FROM THOSE SHOWN BASED UPON ACTUAL FIELD CONDITIONS SCALE 1/8'=1'-0' ` `,im •: tionaII�r ApptOVBa.�...�,,,....� V- SPRINKLER HEADS IN SUSPENDED CEILING WILL HAVE EXPANSION COVERPLATE TO CONCEAL THE 1' SEISMIC GAP Tv `` �� 1 = Ldterto:Follow ( W a IV � / 0#71111.WIDC..i - -"Iier:,*-) abteiFic- , Z ♦ V= : . mil Date: f66-, _ ri5 U O Appr oved plans C y shall be on 'ob site.rl 2 itZ.4491*.e o` � Oo M ® w A V i F fr -4 1 r-Vil ri\ Ai hillum OFJEICE COPY 0 11I !. !I'44$L\4'o1fáL 4. *, , ,o . ......... w Q■ •N A AO/ kI4 r■ NA _� o Z o 1140■A*r# itNialil-11 ..a s-o- 464 40/0 �� .-----. 0 1 J Q >- U >t_ O li Q � ArcSet• �ev.■ „•*/ . z NE 10 cT < D o♦1► a� cMeoe'-o- ��- P w Z U � @ �/14‘ 0�0 1■1111111111111111•111111111=111111111MMIIMI O C�CD �, °�® 1■�hi N /1011 z Q o c o 0 o O O Q V moms ��, rN� , ,,,, ♦ , I O �a}i� , Drawn By 1` �� '■ ■ o -- - 0 1107N1 A el9CP Issue Date 10302012 �����• 0 10,111 I 1 9 m,carmAxm Project# 0 . Ir. r\I■ 010 I ®Id!IH — --- f47 \ SPKR PLAN ,�Acp 9-9 I ■ ■, ° • A�09 9"t \ � I J I I 11111111.11.1 - _ - FP1OF1 / GMB•8•-0-