Report (10) 31)Q2-01 Z- 0013 (o COM check Software Version 3.9.0 Interior Lighting Compliance Certificate Oregon Energy Efficiency Specialty Code Section 1: Project Information Project Type: Alteration Project Title : Marshalls District Manager's Office Suite Construction Site Owner/Agent: Designer/Contractor: 16200 Pacific Hwy. James Dant H.Weston Drumheller Suite X TJX Companies Drumheller Design Studios.Architecture Tigard.OR 97224 770 Cochituate Rd. 8 Interiors.LLC Farmingham.MA 01701 33144 Stone Rd. (415)497-0663 Warren.OR 97053 (503)396-8353 hwestond @yahoo.com Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B x C) Office Suite(Common Space Types:Office-Enclosed)(Ceiling Height 8 ft.) 676 0.97 656 Total Allowed Watts= 656 Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID: Description/Lamp/Wattage Per Lamp I Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Office Suite(Common Space Types:Office-Enclosed 676 sq.ft.) Linear Fluorescent 1:48"T8 32W/Premium efficiency 2 10 62 620 Total Proposed Watts= 620 Section 4: Requirements Checklist In the following requirements, the relevant code section reference is shown in 1]. '+'denotes that more details exist in the specified code section. Checkboxes identify requirements that the applicant has not acknowledged as being met.Check marked requirements identify those the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Lighting Wattage: u 1. [505.1 +]Total proposed watts must be less than or equal to total allowed watts. Allowed Wattage:656 Proposed Wattage:620 Complies:YES Mandatory Requirements: u 2. [505.4)Exit signs.Internally illuminated exit signs shall not exceed 5 watts per side Plans reference page/section: 3. [505.2.2.3+]Daylight zone control.All daylight zones are provided with individual controls that control the lights independent of general area lighting in the non-daylight zone. In all individual daylight zones larger than 350 sq.ft.,automatic daylight controls is provided. Automatic daylight sensing controls reduce the light output of the controlled luminaires at least 50 percent.and provide an automatic OFF control.while maintaining a uniform level of illumination.Contiguous daylight zones adjacent to vertical fenestration may be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e..north.east.south.west). Daylight zones under skylights shall be controlled separately from daylight zones adjacent to vertical fenestration Exception(s): Project Title: Marshalls District Manager's Office Suite Report date: 0710912 Data filename:\\Snjezana-laptop\users\Snjezana\Desktop\DiskGO Backup\Desktop\work\Hprojects12012\H12016 Tigard M DM 710\com\Tigard ComCheck.cck Page 1 of LI Retail spaces adjacent to vertical glazing(retail spaces under overhead glazing are not exempts Li Display,exhibition and specialty lighting ❑ HID lamps 150 watts or less. ❑ Spaces required to have occupancy sensors. Plans reference page/section: LI 4. [505.2.1 +] Interior lighting controls.At least one local shutoff lighting control has been provided for every 2.000 square feet of lit floor area and each area enclosed by walls or floor-to-ceiling partitions.The required controls are located within the area served by the controls or are a remote switch that identifies the lights served and indicates their status. Exception(s): ❑ Lighting systems serving areas designated as security or emergency areas that must be continuously lighted. Lighting in public areas such as concourses.stairways or corridors that are elements of the means of egress with switches that are accessible only to authorized personnel. • Lighting for warehouses.parking garages or spaces using less than 0.5 watts per square foot. ❑ Lighting for contiguous.single-tenant retail spaces. Plans reference page/section: Li 5. [505.2.3+]Sleeping unit controls. Master switch at entry to hotel/motel guest room. Plans reference page/section: L) 6. [505.2.1.1]Egress lighting. Egress illumination is controlled by a combination of listed emergency relay and occupancy sensors to shut off during periods that the building space served by the means of egress is unoccupied. Exception(s): • Building exits as defined in Section 1002 of the Oregon Structural Specialty Code. Plans reference page/section: J 7. [505.2.2+]Additional controls.Each area that is required to have a manual control shall have additional controls that meet the requirements of Sections 505.2.2.1 and 505.2.2.2. Plans reference page/section: Al J 8. [505.2.2.1 +]Light reduction controls.Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either 1)controlling(dimming or multi-level switching)all luminaires:or 2)dual switching of alternate rows of luminaires.alternate luminaires.or alternate lamps:or 3)switching the middle lamp luminaires independently of other lamps;or 4)switching each luminaire or each lamp. Exception(s). LI Only one luminaire in space. ❑ An occupant-sensing device controls the area ❑ The area is a corridor.storeroom,restroom,public lobby or sleeping unit. ❑ Electrical and mechanical room. • Areas that use less than 0.6 Watts/sq.ft. Plans reference page/section: J 9. [505.2.2.2]Buildings larger than 2,000 square feet are equipped with an automatic control device to shut off lighting in those areas. This automatic control device shall function on either: 1)a scheduled basis.using time-of-day.with an independent program schedule that controls the interior lighting in areas that do not exceed 10,000 square feet and are not more than one floor:or 2)an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space:or 3)a signal from another control or alarm system that indicates the area is unoccupied. Exception(s): J Sleeping units,patient care areas:and spaces where automatic shutoff would endanger safety or security. Plans reference page/section: J 10.[505.2.2]Occupancy sensors in rooms that include daylight zones are required to have Manual ON activation. Plans reference page/section: J 11.[505.2.2]An occupant sensor control device is installed that automatically turns lighting off within 30 minutes of all occupants leaving a space. Project Title:Marshalls District Manager's Office Suite Report date:07/09/12 Data filename:\\Snjezana-laptop\users\Snjezana\Desktop\DiskGO Backup\Desktop\work\Hprojects12012\H12016 Tigard M DM 710\com\Tigard ComCheck.cck Page 2 of V Exception(s): Li Classrooms and lecture halls. ❑ Conference. meeting and training rooms ❑ Employee lunch and break rooms. ❑ Rooms used for document copying and printing. ❑ Office spaces up to 300 square feet. • Restrooms. LI Dressing,fitting and locker rooms. Plans reference page/section 12.[505.2.2]Additional controls.An occupant sensor control device that automatically turns lighting off within 30 minutes of all occupants leaving a space or a locally activated switch that automatically turns lighting off within 30 minutes of being activated is installed in all storage and supply rooms up to 1000 square feet. Plans reference page/section: U 13.[505.2.2.2.1]Occupant override.Automatic lighting shutoff operating on a time-of-day scheduled basis incorporates an override switching device that: 1)is readily accessible.2)is located so that a person using the device can see the lights or the area controlled by that switch.or so that the area being lit is annunciated.3)is manually operated.4)allows the lighting to remain on for no more than 2 hours when an override is initiated,and 5)controls an area not exceeding 2.000 square feet Exception(s): LI In malls and arcades,auditoriums.single-tenant retail spaces.industrial facilities and arenas.where captive-key override is utilized.override time is permitted to exceed 2 hours. • In malls and arcades,auditoriums.single-tenant retail spaces.industrial facilities and arenas.the area controlled shall not exceed 20.000 square feet. Plans reference page/section: • 14.[505.2.2.2.2]Holiday scheduling.Automatic lighting shutoff operating on a time-of-day scheduled basis has an automatic holiday scheduling feature that turns off all loads for at least 24 hours,then resumes the normally scheduled operation. Exception(s): ❑ Retail stores and associated malls,restaurants.grocery stores. places of religious worship.theaters and exterior lighting zones. ❑ Single zone electronic time control devices and self-contained wall box preset lighting controls. Plans reference page/section: • 15.[505.2.4+]Exterior lighting controls.Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination of a photosensor and a time switch,or an astronomical time switch.Lighting designated for dusk-to-dawn operation shall be controlled by an astronomical time switch or photosensor. Plans reference page/section. u 16.(505.3]Tandem wiring.The following luminaires located within the same area shall be tandem wired: 1.Fluorescent luminaires equipped with one.three or odd-numbered lamp configurations.that are recess-mounted within 10 feet center-to-center of each other 2.Fluorescent luminaires equipped with one.three or any odd-numbered lamp configuration.that are pendant-or surface-mounted within 1 foot edge-to-edge of each other Exception(s): Li Where electronic high-frequency ballasts are used ❑ Luminaires on emergency circuits. • Luminaires with no available pair in the same area. Plans reference page/section: ❑ 17. [505.5.1 +]Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. Plans reference page/section: U 18.[505.7+]Each dwelling unit in a building is metered separately Plans reference page/section: Interior Lighting PASSES Section 5: Compliance Statement Project Title: Marshalls District Manager's Office Suite Report date:07/09/12 Data filename:\\Snjezana-laptop\users\SnjezanalDesktop\DiskGO Backup\Desktop!work\Hprojects\2012\H12016 Tigard M DM 710\com\Tigard ComCheck.cck Page 3 of Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans.specifications • and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the Oregon Energy • Efficiency Specialty Code requirements in COMcheck Version 3.9.0 and to comply with the mandatory requirements in the Requirements Checklist. Name-Title Signature Date Project Title: Marshalls District Manager's Office Suite Report date:07/09/12 Data filename:\\Snjezana-laptop\users\Snjezana\Desktop\DiskGO Backup\Desktop\work\Hprojects\2012\H12016 Tigard M DM 710\com\Tigard ComCheck.cck Page 4 of Catalog Number IA LITHON/A LIGHTING Notes Type FEATURES & SPECIFICATIONS , A INTENDED USE ES8P provides a high-performance T8 (HPT8) energy-saving alternative to Premium High Performance T8 Lighting 3-lamp, 18-cell parabolic fixtures. Used in place of recommended ed ES8P it can ES8I 2'x4' provide 44% energy savings while meeting IESNA recommended illumi- nance levels. Ideal for retail, educational, and commercial applications requiring lighting power density as low as 0.6 watts/square foot ATTRIBUTES Designed and optimized for use with CEE (Consortium for Energy Efficiency) qualified, high-lumen T8 lamps and energy-efficient electronic ballasts. 2 Lamps Highly reflective surfaces combine with efficient design to produce up to T8 86%photometnc efficiency and a Luminaire Efficacy Rating{LER) of up to 86 using listed lamps and ballast. / j:f CONSTRUCTION Robust design, precision-tooling and automated assembly combine to ore- ate the industry's strongest louver. Rotary sockets provide for simple lamp insertion and positive engagement into lamp contacts. Mechanical light seal requires no foam gasketing. Integral T-bar clips secure fixture to T-bar �a4 system. Housing formed of cold-rolled steel. FINISH Specifications Five-stage iron-phosphate pre-treatment ensures superior paint adhesion Length: 48 11218) and rust resistance. Housing painted after fabrication with environmentally Width:2416091 friendly, high gloss, very high reflectivity polyester powder-coat Louver painted after fabrication with low gloss, high reflectivity polyester Depth: 3-11/16 (94) powder coat. Weight:26 lbs(11.7 kg) OPTICAL All dimensions are inches(millimeters)unless otherwise specified. Mechanical shielding is provided with angled length blades, and linear faceted cross baffles. Contoured housing efficiently directs light downward. Lamp cut-out maximizes shielding even in shallow plenum applications and softens light distribution to deliver a balanced amount of light to both vertical and horizontal surfaces. ELECTRICAL SYSTEM WARRANTY Standard ballast is high-efficiency, CEE qualified, instant-start, <10% THD, Light fixture is guaranteed for one year against mechanical defects in universal voltage and sound rated A. manufacture. Optional program-start and step-dimming ballasts available. Ballast is warranted for five years, and lamp is warranted for three years Ballast disconnect standard on all configurations except EL options. See under system warranty terms provided by lamp and ballast manufacturer. note in Ordering Information. For options, see below. LISTING US PATENTS: 6,210,025; 6,231,213, additional patents pending. Standard: UL;Optional: Canada --CSA or cUL Mexico NOM. Specifications subject to change without notice. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: 2ES8P 232 BILP L835HT8 2ES8P 232 - - — I 1 L Series Trim type Number of Voltage Ballast I [" Lamp Options` i! lamps/wattage 2ES8P (blank) Lay-in (blank) MVOLT" BILP IS,high L835HT8 3100 lumen, EL Emergency battery grid 232 2-lamp, 120 efficiency, long life, pack(nominal 300 F Overlap- 32W'8 277 .78 billow) 3500°K lumens l' ping (48") BINP IS,high L830HT8 3100 lumen, EL14 Emergency battery flanged Included. 347 efficiency, .88 long life, pack(nominal 1400 bi (normal) 3000°K lumens)' BIHP IS,high L841HT8 3100 lumen, PWS1836 6'prewire,3/8"dia., efficiency, long life, 18-gauge,3 wires NOTES. 1.20 bf(high)7 4100°K GEC__ Quick-flex, fixture I MVOLT standard for 120V-271V applications.SO or 60 hz BSNP PS, step- cable, factory operation. Some options require voltage specified. dimming, high installed prewired 2 CEE qualified ballast is not available in 347V. efficiency, .88 cable (RELOC)6 3 Not available with 347V, bf (normal)' CP Chicago plenum 4 Other options available may increase fixture depth to 4-t/2'. approved Consult factory if plenum space is a concern. CSA Listed and labeled to 5 Ballast disconnect not standard with any EL option.Must comply with Canadian specify BOP for inclusion with EL battery packs.UL listed standards only Consult factory for BLIP CSA with EL option. NOM NOM Certified 6 Must specify voltage. Fluorescent Sheet#:2ES8P-2x4 PAR-20 ES8P 2'x4' Premium High-Performance T8 Lighting MOUNTING DATA DIMENSIONS Continuous row mounting of flanged units requires CRE and CRM trim options (see Options). V 0 G F 3-11/16.1941 tip■ l a. • �� I a4.tom, Lay-in Grid Overlapping Flanged Trim All dimensions are inches Imillimetersi unless otherwise specified.Specifications (exposed or concealed grid) with swing-gale hangers subject to change without notice. MT Ail NII Modular Fit-in Trim with swing-gate hangers NOTE: 1 Recommended rough-in dimensions for F-trim fixtures 24'x48'.(Tolerance is+I/4'-0'.) Swing-gate range I-3/16'to 3-15/16'.Swing-gate span 23-3/8'to 26-11/16'.Fixture swing-gate points require additional 9/16'over nominal fixture height. 2ES8P 232,3100 lumens per lamp,test no.LTL 16106 180' Coefficients of Utilization pf��%■��'�90° CP Summary pc 80% 2700% 5O% Zonal Lumen Summary I `��� ° 90 pw 70%50%30% 50%30%1O% 50%30%10% Zone Lumens %Lamp %Fixture 301` ``\4�'80° 0° 1850 1850 0 102 102 102 99 99 99 95 95 95 0°-30° 1441 23.2 27.2 ��`�, 5° 1833 1831 1 94 90 86 88 85 82 84 82 79 0°-40° 2389 38.5 45.0 601���, � 15° 1733 1800 2 85 78 73 77 72 67 74 69 66 0°-60° 4375 70.6 82.5 '� ;60° 25° 1581 1761 3 78 69 62 68 61 56 65 60 55 0°-90° 5304 85.6 100.0 35° 1371 1693 cz 4 71 61 54 60 53 48 58 52 47 90°-180° 0 0.0 0.0 9Or�� , 45° 1119 1606 U 5 65 54 47 53 46 41 52 45 41 0°-180° 5304 85.6 100-0 120.110V' 55° 827 1360 6 60 49 41 48 41 36 47 40 35 65° 522 653 7 56 44 37 44 36 31 42 36 31 150i■A .440° 75° 233 185 8 52 40 33 40 33 28 39 32 28 85° 56 33 9 48 37 30 36 30 25 35 29 25 1801 �-0° 90 0 0 10 45 34 27 34 27 23 33 27 23 Efficiency:85.6% _ _ 0° 90' ENERGY AND UGHT LEVEL COMPARISON Light Input Watts $ Savings System level watts Watts/SF saved % Savings per year LER Parabolic, (3)2800 lumen T8 lamps .88 ballast factor 69 85 1.06 Base Base Base 65 ES8P,(21 3100 lumen T8 lamps,.78 ballast factor 52 48 0.60 37 44% $11.84 86 Light level in footcandles is calculated based on 8x10 mounting centers 9 foot ceilings,60x60 room,80/50/20 reflectances,.95 11.0,.90 LOD,horizontal light level on 2.5 foot workplane height. Annual savings based on 4000 operating hours,5.08/kwh.Luminaire Efficacy Rating(LER)is fixture lumen output divided by fixture input wattage fa L/THON/A L/GHT/NG' Lithonia Lighting Fluorescent AncsAcuiiyBrands Company One Lithonia Way,Conyers,GA 30012 Phone:800-858-7763 Sheet#:2ES8P-2x4 52007 Acuity Brands Lighting,Inc Rev.4/13/09 www.lithonia.com