Loading...
Plans (53) ,a-c1-7 - on 5og IG2 zJs.t - , 4 4 PRODUCT STEVENS SPECIFICATION ROOFING SYSTEMS DATA SHEET c Stevens EPTMBrand of TPO (Thermoplastic Polyolefin) General Description , • • Stevens EP" field sheet membrane is an ethylene propylene, polyester scrim reinforced roofing material. Stevens EPTM membranes meet the ASTM D- 6878-03 specification for TPO roofing materials and is manufactured in an ISO 9001:2001 facility. 1 $ Stevens EP'" field sheet membrane is manufactured by a proprietary calen- :�,:! dering process and consists of two thicknesses of Stevens EPTM compound that fully encapsulate the reinforcing scrim. The base polymer used in the t• Stevens EPTM membrane is by definition Ethylene Propylene. It is made by a two phase, in- reactor polymerization of monomers with a very specific catalyst. The elastomer phase is a non - vulcanized ethylene propylene which imparts the compound with flexibility and low temperature properties. The olefin phase imparts chemical and tear resistance and enhanced strength to the blend and enables the product to be heat welded. The finished polymer is then compounded by Stevens. UV stabilizers, flame retardant, and other ingredients are added to give this product the physical properties it needs to perform long term on the roof. Installation The membrane may be mechanically attached, fully adhered, ballasted or installed as a vented roofing system (VRS) or GardenTop' Roof System. Reference CSI Div. 7 Specifications and Stevens Roofing Detail Drawings. Technical Specifications Membrane Thickness: .045 . 0 - r .080 - inches (white only) (1.14, 1.52, 2.03 mm). Colors: Li Slate Gray, ewter, Buckskin, Desert Brown, Terra Cotta, Patina, Dark Ivy Green and Neon Blue. Dimensions: 76.5 -in. wide x 100-ft. long roll (1.9 m x 30.5 m); also available in 38.25 -inch (.97 m) "half - sheet" width, 52.5 -in., 64.5 -in., 70.5 -in. (1.3, 1.6, 1.8 m) as well as in 10.46- and 12.29 -ft. (3.2, 3.7 m) wide configurations. . Physical Properties: See reverse. Packaging* & Storage Stevens EP membranes come in rolls 76.5 -in. (2 m) wide and 100 ft. (30m) long which provides a coverage rate of approximately 6- squares (600 square -foot) (Stevens EP -XL• is packaged on rolls 75-ft. long). Each roll is shipped from the factory wrapped in protective packaging. Materials are shipped in pyramid or cube -pack (spe- cial order) configurations. Consult the Stevens Customer Service Dept. for details and options. Materials should be stored in a cool, dry location with protective packaging intact. Do not cover with canvas or tarps. Precautions Do not damage or remove protective packaging until ready to install. Note: The Material Safety Data Sheet (MSDS) for this product is on line at www.stevensroofing.com or Technical Manual CD -Rom. *Packaging listed is for Domestic shipments only. For international shipments call 1-413 -552 -1000. Stevens EP is a trademark for TPO membrane manufactured by Stevens Roofing Systems. Stevens Roofing Systems, Nine Sullivan Road, Holyoke, MA 01040 USA Tel: (877) 788 -8324 Intntl: 1 -(413) 552 -1000 Fax: (413) 552 -1010 PDS.03.06. 1 Web: stevensroofing.com Email: info @stvroof.com • . diiiii PRODUCT ®_ -- STEVENS SPECIFICATION pp p - ROOFING SYSTEMS DATA SHEET Stevens EP Brand of TPO (Thermoplastic Polyolefin) Physical Properties - Stevens EPT Physical Propterty Test Method Typical Values Typical Yalu = = Typical Values 45 mil' 60 mil' 80 mil' (1.14 mm) (1.52 mm) (2.03 mm) 1 Breaking Strength ASTM D -751 275 Ibf.(1.2 kN) 320 Ibf.(1.4 kN) ;390 lbf. (1.7 kN) Tear Strength ASTM 0 -751 Procedure B, 8 °x8° sample) 135 lbf.(.60 kN) 110 lbf.(.49 kN) 104 tbf. (.46 kN) Dimensional Stability ASTM D-6878 (white: 6 hrs. t0.3 1-0.3 t0.2 (% change max.) @ 158 Hydrostatic Resistance ASTM D -751 (Method A) 400 psi (2.8 MPa 425 psi (2.9 MPa 510 psi (3.52 MPa) Ozone Resistance" ASTM D -1149 Pass I Pass Pass (70 hrs.@100 Weather Resistance Xenon Arc, ASTM 0 -6878 No cracks, No cracks, No cracks, G- 155; 5040 kJ /ma Loss of breaking loss of breaking( loss of breaking 0.35w/m' (a) 340 nm strength or tear strength or tear strength or tear strength strength strength EMMAQUA (Concentrated Pass Pass I Pass Natural Sunlight) (ASTM G.90) 167 359 kJ /m' total UV radiant exposure Puncture Resistance FTM 101B (Method 2031) 330 lbf. (1.5 kN) 400 Ibf. (1.8 kI1) 500 lbf. (2.2 kN) Water Vapor Transmission ASTM E -96 (Procedure B 0.035 Perms 1 0.035 Perms 0.035 Perms Condition BW @ 72°F/22.2°C) Elongation ( %) Ultimate" ASTM 0-412 (Die C) 700% V 700% 700% Brittleness ASTM 0 -2137 @ - 49 °F/ -45 °C Pass \ Pass Pass Water Absorption ASTM D-6878 D -471, t3 *3 1 3 (max. % weight change)" (158 for 7 days) Testing only one side section Heat Aging ASTM D-6878 D -573 Break: 2501 • Break: 290 lbf. Break: 350 lbf. (28 days @ 240 (1.1 kN) (1.29 kN) ( (1.56 kN) Solar Reflectance (initial) ASTM E -903 >70% >70% >70% Thermal Emittance ASTM E-408 >0.93 >0.93 >0.93 *Thickness (nominal) per ASTM D -751 test method. NJ "Test performed on non - reinforced Stevens EP membrane. Stevens EP is a trademark for TPO membrane manufactured by Stevens Roofing Systems. Stevens Roofing Systems, Nine Sullivan Road, Holyoke, MA 01040 USA Tel: (877) 788 -8324 intntl: 1 -(413) 552 -1000 Fax: (413) 552 -1010 PDS.03.06. 2 Web: stevensroofing.com Email: info @stvroof.com • pReDucT. -SPECIFICATION pp- ® 1'1 AT zn�E ROOFING SYST _ General Description G S 3 Ttd l+- V/L eee a-77 0 P Stevens Iso insulation products and Recover Board are FM Approved (4450/4470) for Class 1 insulat- ed steel, wood, concrete and gypsum roof deck construction for both 1 -60 and 1 -90 Windstorm Classifications. Stevens Iso products meet UL Class A classifications as well as a variety of UL "P" clas- sifications for fire resistance. Stevens Iso -2000 is compatible with all Stevens EP'°" , Stevens EVTM' and Stevens Hypalon® mem- branes, and are recommended for single -ply membranes, hot asphalt or coal tar BUR and modified bitu- men. The material is a closed -cell, polyisocyanurate core integrally laminated to heavy black (non - asphaltic), fiber - reinforced felt facers. Stevens ISO -2000 is made with standard 20 -psi formula however, it is also available in 25 -psi formulas. Technical Specifications Dimensions: panel size 4 x 8 -ft. (1.2 x 2.4 m). Compliance: - ASTM C1289 -95, Type II. - BOCA, ICBO and SBCCI Sections on Foam Insulation. Precaution The product is a polyisocyanurate organic plastic foam and will burn if exposed to an ignition source of sufficient heat and intensity, or open flames. Keep away from excessive heat and open flames. Packaging & Storage Factory packaging is only intended for protection during transit. When stored outdoors or on the job site, packages should be stacked on pallets at least four (4) in. (.102 m) above ground level and com- pletely covered with a weatherproof covering. The temporary factory- applied packaging should be slit or removed to prevent the accumulation of condensation. Roof ThInlmess LTTR Value Thickness LTTR Value insulation that is wet and/or damaged should be removed 1.0 -in. 6.0 2.6 15.9 and replaced with solid, dry insulation. 1.1 6.6 2.7 16.6 1.2 7.2 2.8 17.2 Note 1.3 7.8 2.9 17.9 1.4 8.4 3.0 18.5 The Material Safety Data sheet (MSDS) for this product is . 1.5 9.0 3.1 19.1 available on line at www.stevensroofing.com or the Steven 1.6 9.6 3.2 19.8 Technical Manual CD -Rom. 1.7 10.3 3.3 20.4 1.8 10.9 3.4 21.1 Y*11 1.9 11.5 3.5 21.7 2.0 12.1 3.6 2.4 2.1 12.8 3.7 23.0 2.2 13.4 3.8 23.7 2.3 14.0 3.9 24.3 2.4 14.7 4.0 25.0 2.5 15.3 Stevens Roofing Systems, Nine Sullivan Road, Holyoke, MA 01040 USA Tel: (877) 788 -8324 Intntl: 1 -(413) 552 -1000 Fax: (413) 552 -1010 Web: stevensroofing.com Email: Info@stvroof.com PDS.03.06.39