Loading...
Correspondence (16) Tr".0(.0 /?.E, ch (4e, w re2 ck M ,der -,irk -- 3 v P 96, - O� S ee0 ri '-t $1 Q C C 4.d 24),,,, 8 r ;t y 7 c c v "4 v,n,NA N!ilkg K CS7cePW Cgict4-,0- thq7 - 0 79y - Icy■ TIMM fl fit" ,l1 July 1, 1996 ritiP2ff /I • mai Mr. Gary Lampella nuil LINNHART ASSOCIATES 205 Mai /Suit. 205 3855 -3 Wolverine Street N.E. Hifl -••ro. oR97 23 mum Salem, Oregon. 97305 RE: "THE ORIGINAL CHICKEN BAR" LP2A Job No.: 96522.030 City No. BUP: 96 -0257 Dear Mr. Lampella, We are in receipt of your plans examination sheet dated June 7, 1996, and would like to take this occasion to respond to your comments for this project. I would like to address these in the chronological order in which they appear in your letter. 1. 25 percent of the total cost of the project to be used to address existing architectural barriers. This project is a tenant improvement within a relatively new commercial retail center. Parking lot striping and ramp has been taken care of through the building shell and other tenant improvements that precede this project. The existing storefront door system and threshold meets current standards. We are providing two handicap accessible toilet rooms, and counter area shall meet current • standards as well. In that there is not any need for other ADA issues, we meet all the requirements of O.S.S.C. and Oregon Revised statutes. 2. If a one hour shaft is required, then we shall construct it similar to the Gypsum association file number WP 3510 which is one layer of 5/8" gypsum wallboard or veneer base applied parallel with or at right angles to each side of 2 x 4 wood studs spaced at 24" on center, with 6d coated nails 1 7/8" long, 0.0915" shank, 1/4" heads, 7" on center. 3. The suspended ceiling is currently in place, and is only to be cleaned. We shall verify if the suspended ceiling meets the requirements of seismic bracing. A copy of the seismic bracing has been included for reference. 4. The owner of "The Original Chicken Bar ", Marc Kaplin, • shall submit the proper materials to the Health • Department for their review and approval. It should be noted that this is the fourth location of "The Original Chicken Bar ", and the owners are aware of the • • Mr. Gary Lampella July 1, 1996 Page 2. requirements of the Health and other departments which will need to be consulted for this project: 5. The City of Tigard has waived the requirement for a grease interceptor trap. 6. These lites are existing. In that the structure is relatively new, these lites would have been required to be- tempered based upon their location relative to the entry door. 7. Two 2:A,10 fire extinguisher shall be provided for this . project. The shall be placed at a maximum of 75 feet from one another, and placed as approved by the fire marshall's office. We hope that these descriptions meet with your approval, and look forward to acquiring the building permit for this project. Thank -you for your assistance. Sincerely, � Michael G. Parich, Tigard: ORIGINAL CHICKEN BAR Initial Plan Review LP Job No. 96522.030 City No. BUP 96 -0257 June 7, 1996 Michael Parich 205 E Main, Suite 205 Hillsboro, Oregon 97123 Re: Tenant Improvement - Original Chicken Bar, 16200 SW Pacific Highway Floor Area: 1,200 sq. feet Construction Type: V -N Sprinklered Occupancy: B Occupant Load: 24 Use: Restaurant LP (Linhart Peterson Powers Associates) has completed re- review of the documents requested in the May 21, 1996 initial plan review. These documents were reviewed only for their conformance to the City of Tigard building regulations and the State of Oregon Specialty Codes, 1996 Edition. This review does not include mechanical, plumbing, electrical or fire sprinkler and fire alarm modifications. These shall be submitted and reviewed by the City of Tigard. 1. Architectural Drawings, Sheets: 1 - 3. We have found the following deficiencies in the submitted plans for this project: 1. Please show how 25% of the total cost of the project will be used to remove existing architectural barriers to obtain accessibility. Section 1113.1.1 O.S.S.C. and Oregon Revised Statute 447.241. 2. Detail 3/2 on Sheet 2 identifies a 2 -Hr. Shaft by Owner. Although only a 1 -Hr. Shaft is required, an approved, listed and tested fire- resistive assembly is required for the shaft for the Type I Hood. Please submit drawings showing how this assembly will be constructed. 3. Please provide detail of seismic bracing for the suspended ceiling grid system. 4. Submit plans to the Washington County Health Department for review and approval. A final inspection shall be conducted by this agency prior to occupancy. 5. Install an approved grease interceptor trap as directed by the City of Tigard and the Unified Sewerage Agency requirements. 6. The main entry door has glazing within a 24 -inch arc of the door. Please provide labeled safety glazing for these relites. Section 2406.4 O.S.S.C. 7. Provide a minimum 2:A,10:BC fire extinguisher for every 3,000 sq. Ft. Of floor area with a travel distance between extinguishers not exceeding 75 feet. UFC standard 10 -1. LP recommends the building permit not be issued for this project until receipt and approval of the preceding items. Please submit this information so we may complete our review. LINHART PETERSEN POWERS ASSOCIATES 3855 -3 Wolverine Street NE • Salem, OR 97305 (503) 371 -2212 • FAX: (503) 371 -3853 Response such as, "see plans" or "by others" does not save time or satisfy requirements. Show or note specifically how compliance is achieved. If you have questions, please contact Gary Lampella at (503) 371 -2212. Respectfully, LINHART PETERSEN POWERS ASSOCIATES Gary Lampella Building & Mechanical Inspector /Plans Examiner c: David Scott, Building Official • .outag - c)--0.7-57 1 Tigard: ORIGINAL CHICKEN BAR Second Plan Review LP Job No. 96522.030 City No. BUP 96 -0257 July 5, 1996 Michael Parich 205 E Main, Suite 205 Hillsboro, Oregon 97123 Re: Tenant Improvement - Original Chicken Bar, 16200 SW Pacific Highway Floor Area: 1,200 sq. feet Construction Type: V -N Sprinklered Occupancy: B Occupant Load: 24 Use: Restaurant LP (Linhart Peterson Powers Associates) has completed re- review of the documents requested in the May 21, 1996 initial plan review. These documents were reviewed only for their conformance to the City of Tigard building regulations and the State of Oregon Specialty Codes, 1996 Edition. This review does not include mechanical, plumbing, electrical or fire sprinkler and fire alarm modifications. These shall be submitted and reviewed by the City of Tigard. 1. Architectural Drawings, Sheets: 1 - 3. LP recommends the issuance of the building permit for this project subject to the following: 1. Please show how 25% of the total cost of the project will be used to remove existing architectural barriers to obtain accessibility. Section 1113.1.1 O.S.S.C. and Oregon Revised Statute 447.241. • Response accepted. 2. Detail 3/2 on Sheet 2 identifies a 2 -11r. Shaft by Owner. Although only a 1 -Hr. Shaft is required, an approved, listed and tested fire- resistive assembly is required for the shaft for the Type I Hood. Please submit drawings showing how this assembly will be constructed. Plans for this shaft will still be required by the City of Tigard. Please submit details prior to construction of this shaft. Response to this item is an acceptable listed assembly (see attached letter from Michael G. Parich) 3. Please provide detail of seismic bracing for the suspended ceiling grid system. Existing ceiling grid, no modifications being done. 4. Submit plans to the Washington County Health Department for review and approval. A final inspection shall be conducted by this agency prior to Occupancy. Response accepted. 5. Install an approved grease interceptor trap as directed by the City of Tigard and the Unified Sewerage Agency requirements. Response accepted. 6. The main entry door has glazing within a 24 -inch arc of the door. Please provide labeled safety glazing for these relites. Section 2406.4 O.S.S.C. Glazing is existing. Response accepted. LINHART PETERSEN POWERS ASSOCIATES 11? 3855 -3 Wolverine Street NE • Salem, OR 97305 (503) 371 -2212 • FAX: (503) 371 -3853 7. Provide a minimum 2:A,10:BC fire extinguisher for every 3,000 sq. Ft. Of floor area with a travel distance between extinguishers not exceeding 75 feet. UFC standard 10 -1. Response accepted. If we can be of further service to you, please call us at 371 -2212. Respectfully, LINHART PETERSEN POWERS ASSOCIATES Gary Lampella Building & Mechanical Inspector /Plans Examiner c: David Scott, Building Official