Loading...
Correspondence (17) ‘6 cc) CONSOLIDATED FIRE AND RESCUE I CI s f Washington County Fire District No. 1 City of Beaverton Fire Department 4. Tualatin Fire District FIRE MARSHALS OFFICE October 11, 1988 Sarah M. Tentau Westwood Corporation 3030 S.W. Moody Portland, Oregon 97201 RE: It's Country Tigard Towne Square - Suite 0 16200 S.W. Pacific Hwy. Tigard, Oregon 97224 Dear Sarah: A fire and life safety plan review was conducted on the above captioned project for compliance with the 1985 editions of the Uniform Building Code (UBC), Uniform Mechanical Code (UMC), and Uniform Fire Code (UFC) as amended by Tualatin Rural Fire Protection District's Ordinance 86 -5. Plans are approved conditional to the following items: 1. Exit Door Hardware: All doors shown on the drawings must be openable from the inside for immediate exit at all times without the use of a key, special knowledge, or effort. (UBC Sec. 3304) 2. Firestopping: In all wood framed walls and partitions, firestopping consisting of 2 -inch nominally -sized lumber or other approved materials must be installed at all floor and ceiling levels. Penetrations in this prescribed firestopping to accommodate wiring, plumbing. and .other similar utility runs must be packed with noncombustible materials in an approved manner so as to prevent the passage of flame. (UBC Sec. 2516) 3. Fire Extinguisher Required: A fire extinguisher having a minimum rating of 2A10B:C must be placed in an accessible location within plain view. (UFC Sec. 10.301(a)) 4. Approved Plans on Job Site: One set of approved plans bearing the stamps of the Tigard Building Department and this office must be maintained on the project site throughout all phases of construction and must be made available to building and fire inspectors for reference during required construction inspections. (UBC Sec. 303) 4755 S.W. Griffith Drive • P.O. Box 4755 • Beaverton, Oregon 97076 • (503) 526 -2469 Sarah M. Tentau October 11. 1988 Page 2 5. Inspections Required: Inspection and approval of construction by a representative of this office is required: (a) prior to the cover of any new framing elements following the installation of all utility runs which will be concealed within wall and partition cavities; (b) upon completion of construction and prior to occupancy of the tenant space. (UBC Sec. 305) 6. Certificate of Occupancy Required: Prior to the use and occupancy of the project (space), a certificate of occupancy or other written instrument of approval must be obtained from the City of Tigard Building Department. (UBC Sec. 307) SPECIAL NOTICE: DEVIATIONS FROM THE SUBMITTED AND HEREBY CONDITIONALLY APPROVED PLANS DURING THE COURSE OF CONSTRUCTION, EXCLUSIVE OF THOSE NECESSARY TO COMPLY WITH FIRE SAFETY REQUIREMENTS AS LISTED HEREIN, ARE PROHIBITED WITHOUT THE WRITTEN AUTHORIZATION OF THE WASHINGTON COUNTY BUILDING DEPARTMENT AND THIS OFFICE. APPROVAL OF SUBMITTED PLANS IS NOT AN APPROVAL OF OMISSIONS OR OVERSIGHTS BY THIS OFFICE OR OF NON- COMPLIANCE WITH ANY APPLICABLE REGULATIONS OF LOCAL GOVERNMENT. If I can be of any further assistance to you, please feel free to contact me at 526 -2502. Sincerely, III Gene Birchill Deputy Fire Marshal GB:kw / cc: Tigard Building Department l/ CITY OF TIGA RD OREGON October 10, 1988 \\\„..< Linda Jones Westwood Corporation PROJECT: Tigard Town Square Shops A It's Country, BP882001 Cianci's Videoland, BB 881983 Dear Ms. Jones: Plans for this project have been reviewed for conformity with applicable codes and are approved. We note that the mechanical and plumbing plans will be separately submitted. If we may be of assistance, or if you have any questions, contact us at any time. Sincerely, Jim Jaqu. Plans Examiner cs/7476D 13125 SW Hall Blvd., P.O. Box 23397,11gard, Oregon 97223 (503) 639 -4171