• tçico Fire Suppression ■ l r " �, 1 11 .•& Building Products - 1 89.11 20i2. 1 ( fGi Technical Services 800-381-9312 I+1-401-781-8220 tl. , i. www.tyco-fire.com g ONG DIMS e Series TY-FRB — 2.8, 4.2, 5.6, and 8,0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Corrosion-resistant coatings, where applicable, are utilized to extend the - Descri tion life of copper alloy sprinklers beyond �+ '" i v ter:. Description that which would otherwise be obtained when exposed to corrosive atmo �.I 'i✓ , , The TYCO Series TY-FRB,2.8,4.2,5.6, p ,n li �: and 8.0 K-factor, Upright and Pendent spheres.Although corrosion-resistant ?l, l Sprinklers described in this data sheet coated sprinklers have passed the ,.= I „... '' are quick response,standard coverage, standard corrosion tests of the appli- j s decorative 3 mm glass bulb-type spray cable approval agencies,the testing is • ,' ' sprinklers designed for use in light or not representative of all possible cor u• ordinary hazard,commercial occupan- rosive atmospheres. Consequently, ..� « ' a cies such as banks, hotels, and shop- it is recommended that the end user ping malls. be consulted with respect to the suit- ability of these coatings for any given The recessed version of the Series TY- corrosive environment.The effects of FRB Pendent Sprinkler,where applica- ambient temperature,concentration of b IN le, is intended for use in areas with a chemicals,and gas/chemical velocity, finished ceiling.This recessed pendent should be considered,as a minimum, ?! sprinkler uses one of the following, along with the corrosive nature of the "� • A two-piece Style 10 (1/2 inch NPT) chemical to which the sprinklers will be i ' ,r or Style 40(3/4 inch NPT) Recessed exposed. l§" Escutcheon with 1/2 inch(12,7 mm)of An intermediate level of the Series TY- recessed adjustment or up to 3/4 inch FRB Pendent Sprinklers is detailed ` " (19,1 mm)of total adjustment from the in Technical Data Sheet TFP356, and ='ti�N. flush pendent position,or a Sprinkler Guards are detailed in Tech- • A two-piece Style 20(1/2 inch NPT) nical Data Sheet TFP780. or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch(6,4 mm)of NOTICE Model/Sprinkler recessed adjustment or up to 1/2 inch The Series TY-FRB Concealed Pendent (12,7 mm)of total adjustment from the Sprinklers described herein must be flush pendent position. installed and maintained in compliance Identification The adjustment provided by the with this document and with the appli Number (SIN) Recessed Escutcheon reduces the cable standards of the National Fire , accuracy to which the fixed pipe drops Protection Association, in addition to to the sprinklers must be cut. the standards of any authorities having TY1131: Upright 2.8K,1/2"NPT jurisdiction.Failure to do so may impair TY1231: Pendent 2.8K,1/2"NPT the performance of these devices. TY2131: Upright 4.2K,1/2"NPT TY2231: Pendent 4.2K 1/2"'NPT Owners are responsible for maintaining TY3131: Upright 5.6K,1/2"'NPT 0 "v their fire protection system and devices _ in proper operating condition. The TY3231: Pendent 5.6K,1/2"NPT IMPORTANT installing contractor or sprinkler mane TY4131: Upright 8.0K,3/4""NPT N Always refer to Technical Data TY4231: Pendent 8.0K,3/4'"NPT N 0 facturer should be contacted with any Sheet TFP700 for the "INSTALLER questions. TY4831: Upright' 8.0K,1/2'"NPT (V— WARNING" that provides cautions TY4931: Pendent' 8.0K,1/2"NPT J 1 with respect to handling and installation of sprinkler systems and O components.Improper handling and installation can permanently damage J a sprinkler system or its components < N and cause the sprinkler to fail to cb operate in a fire situation or cause it to operate prematurely. 'Eastern Hemisphere Sales Only / Page 1 of 10 JULY 2010 TFP171 TFP171 Page 2 of 10 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 SSU* NOMINAL 1/2" PLATE SEATING RECESSED MAKE IN SURFACE ESCUTCHEON DEFLECTOR NPT 5 =� ? .rii 7/16" (11,1 mm 2 1/4" 4 ' I NOMINAL airli - � t (57,2 mm) �`- 2 IF Fr MAKE-IN�te �L I 1-9/16" 3 2-3/16" „� f�i (55,6 mm) i WRENCH 1411° (39,7 mm) I 1 �; FLATS 1/2"NPT SSP DEFLECTOR* -••-- 2-7/8"(73,0 mm)DIA. -- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembl •'Temperature rating is indicated on deflector or adjacent to 2-Button Y 5-Compression 7-Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 * NOMINAL PLATE SEATING RECESSED SSU DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* i;:nirT1�*'11TH":� r'//011 , _c 5 '�' 7/16' (11,1 mm) } �- 2-3/16" ��4 i NOMINAL =1 4 (55,6 mm) IF IF W MAKE-IN �� 2 (55,6/mm) j � WRENCH ( 1 1m'l 38,11mm) 3 1 _- FLATS . 1 1/2"NPT SSP DEFLECTOR* - 2-7/8"(73,0 mm)DIA. — CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembl 'Temperature rating is indicated on deflector or adjacent to 2-Button y 5-Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT TFP171 Page 3 of 10 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 * NOMINAL PLATE SEATING RECESSED SSU MAKE-IN 1/2" SURFACE ESCUTCHEON DEFLECTOR NPT 5 "mot 7/16" I , �— / ' I (11,1 mm) I } ■,r- i 2-3/16' �� t 4 NOMINAL j 1 (55,6 mm) MAKE IN cjil �`��I 2 .'. 2-3/16" �' 1 1/2"T (55,6 mm) ! WRENCH (38,1 mm) Nol 3 FLATS 1/2"NPT SSP DEFLECTOR* -.-- 2-7/8"(73,0 mm)DIA. -- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Aen bl 4-Bulb 6-Deflector 'Temperature rating is indicated on deflector or adjacent to 2-Button Y 5-Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT 1/2"(12,7 mm) ESCUTCHEON STYLE 30 or 40 SSU* NOMINAL 3/4„ PLATE SEATING RECESSED MAKE-IN SURFACE ESCUTCHEON DEFLECTOR NPT 6* I I I i t'?a * `\ ` rat = L 5 41 i 1/2" • I 11 Ali I (12,7 mm) i 2-5/16" �.� 4 NOMINAL �' (58.7 mm) MAKE-IN .,.L— 2 2-1/4" 1-9/16" 3/ 7 (57,2 mm) I iiIjr (39,7 mm) Ill. 1 7Y t f f ! ' 3/4"NPT SSP DEFLECTOR* -- 2-7/8"(73,0 mm)DIA. - CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3 Assembl 4-Bulb 6-Deflector "Temperature rating is indicated on deflector or adjacent to 2-Button Y 5-Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,3/4 INCH NPT ■ TFP171 Page 4 of 10 7/16"(11,1 mm) SSU* NOMINAL 1/2" DEFLECTOR MAKE-IN NPT 5 7/16' 4 (NOMINAL t VIIIIMMI (57,2/mm)li Fr MAKE-IN 1 2/ t V I 2-3/16' / 1-9/16" 3 (55,6 mm) + WRENCH (39,7 mm) -= FLATS FLATS 1 J i — �.. } SSP* CROSS 1/2"NPT DEFLECTOR SECTION UPRIGHT PENDENT 1 -Frame 3 Asse bl 4-Bulb 6-Deflector •Temperature rating is indicated on deflector or adjacent to 2-Button y 5-Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(7Y4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Operation inch (1,6 mm) for the 135°F/57°C and A 3/32 inch(2,4 mm)for the 286°F/141°C Data The glass Bulb contains a fluid that temperature ratings. expands when exposed to heat.When Obtain a leak-tight 1/2 inch NPT sprin- Approvals the rated temperature is reached, the kler joint by applying a minimum to UL and C-UL Listed fluid expands sufficiently to shatter the maximum torque of 7 to 14 ft.lbs. (9,5 FM, LPCB, and NYC Approved glass Bulb, allowing the sprinkler to to 19,0 Nm). Higher levels of torque Refer to Table A and B for complete activate and water to flow. can distort the sprinkler Inlet with con- approval information including sequent leakage or impairment of the corrosion-resistant status. Design sprinkler. Maximum Working Pressure /� Do not attempt to compensate for Refer to Table C. Criteria insufficient adjustment in the Escutch- eon Plate by under-or over-tightening Discharge Coefficient The TYCO Series TY-FRB Pendent the sprinkler. Re-adjust the position of K=2.8 GPM/psi1/2 (40,3 LPM/bars/2) and Upright Sprinklers are intended the sprinkler fitting to suit. K=4.2 GPM/psit/2 (60,5 LPM/bars/2 for fire protection systems designed in accordance with the standard installa The Series TY-FRB Pendent and K=5.6 GPM/psi,/2 (80,6 LPM/bar1/2) tion rules recognized by the applicable Upright Sprinklers must be installed K=8.0 GPM/psi1/2 (115,2 LPM/bar1/2) Listing or Approval agency(such as,UL in accordance with the following Listing is based on the requirements of Temperature Rating instructions. Refer to Table A and B. NFPA 13,and FM Approval is based on 1. Install Pendent sprinklers in the the requirements of FM's Loss Preven- pendent position. Install upright Finishes tion Data Sheets). Only the Style 10, sprinklers in the upright position. Sprinkler: Refer to Table A and B. 20,30,or 40 Recessed Escutcheon,as 2. With pipe thread sealant applied to Recessed Escutcheon:White Coated, applicable, is to be used for recessed the pipe threads, hand-tighten the Chrome Plated,or Brass Plated. pendent installations. sprinkler into the sprinkler fitting. Physical Characteristics Installation 3. Tighten the sprinkler into the sprin- Frame Bronze kler fitting using only the W-Type 6 Button Brass/Copper The TYCO Series TY-FRB Sprinklers Sprinkler Wrench (Figure 14). With Sealing Assembly Beryllium must be installed in accordance with reference to Figures 1 through Nickel w/Teflont the following instructions. 5, apply the W-Type 6 Sprinkler Bulb Glass Wrench to the sprinkler wrench Compression Screw Bronze NOTICE flats. Deflector Copper/Bronze Bushing(K=2.8) Bronze Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter t Registered Trademark of Dupont of the air bubble is approximately 1/16 TFP171 Page 5 of 10 SPRINKLER FINISH(See Note 5) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME WHITE*** FACTOR COLOR BRASS PLATED POLYESTER 135°F/57°C Orange PENDENT 155°F/68°C Red (TY1231) and 175°F/79°C Yellow 1,2,3,4 UPRIGHT (TY1131) 200°F/93°C Green 286°F/141°C Blue • 135F/57°C Orange 2.8 RECESSED 155°F/68°C Red 1/2"NPT PENDENT (TY1231)* 175°F/79°C Yellow Figure 6 200°F/93°C Green 1,2,4 135°F/57°C Orange RECESSED PENDENT 155F/68°C Red (TY1231)** 175°F/79°C Yellow Figure 7 200°F/93°C Green 135°F/57°C Orange PENDENT 155°F/68°C Red (TY2231) and 175°F/79°C Yellow UPRIGHT (TY2131) 200°F/93°C Green 286°F/141°C Blue 135'F/57°C Orange 4.2 RECESSED 1/2"NPT PENDENT 155F/68°C Red 1,2 (TY2231)* 175°F/79°C Yellow Figure 8 200°F/93°C Green 135F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY2231)** 175°F/79°C Yellow Figure 9 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. Frame and Deflector only.Listings and approvals apply to color(Special Order). N/A:Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH(See Note 8) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME WHITE*** LEAD FACTOR COLOR BRASS PLATED POLYESTER COATED 135°F/57°C Orange PENDENT (TY3231) 155°F/68°C Red and 175°F/79°C Yellow 1,2,3,4,5,6,7 1,2,3,5 UPRIGHT 200°F/93°C Green (TY3131) 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red 5.6 PENDENT 175°F/79°C Yellow 1,2,4,5 N/A 1/2"NPT (TY3231)' Figure 10 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 175°F/79°C Yellow 1,2,3,4,5 N/A (TY3231)'" Figure 11 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange PENDENT 155°F/68°C Red (TY4231) and 175°F/79°C Yellow 1,2,3,4,5,6,7 1,2,5 UPRIGHT 200°F/93°C Green (TY4131) 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red 8.0 PENDENT 175'F/79°C Yellow 1,2,5 N/A 3/4"NPT (TY4231)' Figure 12 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT _ 175°F/79°C Yellow 1,2,3,5 N/A (TY4231)°° Figure 13 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange PENDENT 155°F/68°C Red 8.0 (TY4931) 1/2"NPT and 175°F/79°C Yellow 1,2,4,5,6 1,2,5 UPRIGHT 200°F/93°C Green (TY4831) 286°F/141°C Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. "Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. Frame and Deflector only.Listings and approvals apply to color(Special Order). N/A:Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD FACTOR BRASS PLATED POLYESTER COATED PENDENT(TY1231) and UPRIGHT(TY1131) 2.8 75 PSI(12,1 BAR) N/A 1/2"NPT RECESSED PENDENT(TY1231) PENDENT(TY2231) and 4.2 UPRIGHT(TY2131) 175 PSI(12,1 BAR) N/A 1/2"NPT RECESSED PENDENT(TY2231) PENDENT(TY3231) 175 PSI and (12,1 BAR) 5.6 UPRIGHT(TY3131) 250 PSI(17,2 BAR) 1/2"NPT OR 175 PSI(12,1 BAR) — RECESSED (SEE NOTE 1) N/A PENDENT(TY3231) PENDENT(TY4231) 175 PSI and (12,1 BAR) 8.0 UPRIGHT(TY4131) 3/4"NPT 175 PSI(12,1 BAR) RECESSED N/A PENDENT(TY4231) PENDENT(TY4931) 1/28 NPT and 175 PSI(12,1 BAR) (12,5 BAR) UPRIGHT(TY4831) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Underwriters Laboratories.Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE The Series TY-FRB Recessed Pendent Care and Exercise care to avoid damage to Sprinklers must be installed in accor- sprinklers before, during, and after dance with the following instructions. Maintenance installation. Never paint, plate, coat, 1. After installing the Style 10,20,30, or otherwise alter automatic sprinklers or 40 Mounting Plate, as applica- The TYCO Series TY-FRB must be after they leave the factory. ble, over the sprinkler threads and maintained and serviced in accordance Replace sprinklers that: with pipe-thread sealant applied to with the following instructions. • were modified or over heated. the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. NOTICE • were damaged by dropping,striking, 2. Tighten the sprinkler into the sprin- wrench twisting,wrench slippage,or kler fitting using only sprinkler into the sp i 7 Before closing a fire protection system the like. main control valve for maintenance • are leakin or exhibitin visible sins Recessed Sprinkler Wrench (Fig- work on the'fire protection system of corrosio g g ure 15). With reference to Figures 1 that it controls, obtain permission to n. to 4,apply the W-Type 7 Recessed shut down the affected fire protection • were exposed to corrosive products Sprinkler Wrench to the sprinkler systems from the proper authorities of combustion but have not oper- wrench flats. and notify all personnel who may be ated, if you cannot easily remove 3. After ceiling installation and finish- affected by this action. combustion by-products with a cloth. ing,slide on the Style 10,20,30,or Absence of the outer piece of an • have a cracked bulb or have lost liq- 40 Closure over the Series TY-FRB escutcheon, which is used to cover uid from the bulb.Refer to the Instal- Sprinkler and push the Closure over a clearance hole, can delay sprinkler lation section in this data sheet. the Mounting Plate until its flange operation in a fire situation. comes in contact with the ceiling. TFP171 Page 8 of 10 2-7/8"DIA. 2-7/8"DIA. (73,0 mm) " (73,0 mm) 5/8±1/4" mm) 1/2±1/8" 3/4" mm (19,1 1/2"(12,7 mm) - (15,9±6,4 mm) 2 1/4"DIA._� 1/4"(6,4 mm) (12,713,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) (57,2 mm) (57,2 mm) i FACE OF SPRINKLER ( ) 57,2 mm MOUNTING I FACE OF I MOUNTING PLATE SPRINKLER PLATE FITTING FITTING 1/8., 1/8" ' (3,2 mm) • 1 a (3,2 mm) ,,, MOUNTING l,�r; f MOUNTING SURFACE SURFACE ,v-r-f1�. .yT!�'�'. CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16'(27,0 mm) FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8"DIA. 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (73,0 mm) 1/2"1/2 (12,7 mm 1/2±1/8" ( mm) (15,9±6,4 mm) 1/4'(6,4 mm) i (12,7±3,2 mm) 1/4"(6,4 mm 2-1/4'DIA. L 2-1/4"DIA. ( mm)• FACE OF mm)(57,2 mm) —' MOUNTING FACE OF (57,2 mm MOUNTING SPRINKLER PLATE ' SPRINKLER PLATE FITTING �� FITTING / / I 1/8" 1/8" a. (3.2 mm) f / .. I (3,2 mm) I ��, II M.-imui II MOUNTING 1l' i MOUNTING !W! } SURFACE SURFACE/ } ._ CLOSURE SERIES 1-1/4"(31,8 mm) SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) CLOSURE T1-FRB 1"(25,4 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 4.2 K-FACTOR, 1/2 INCH NPT Initial and frequent visual inspections of Responsibility lies with the owner for Care must be exercised to avoid dam- random samples are recommended for the inspection, testing, and mainte- age to the sprinklers -before, during, corrosion-resistant sprinklers to verify nance of their fire protection system and after installation.Sprinklers dam- the integrity of the corrosion-resistant and devices in compliance with this aged by dropping, striking, wrench material of construction. Thereafter, document, as well as with the appli- twist/slippage, or the like, must be annual inspections per NFPA 25 should cable standards of the National Fire replaced. Also, replace any sprinkler suffice. Protection Association (for example, that has a cracked bulb or that has lost Inspections of corrosion resistant NFPA 25), in addition to the standards liquid from its bulb. (Ref. Installation sprinklers are recommended at close of any other authorities having jurisdic- Section). tion range, instead of from the floor level tion.Contact the installing contractor or Initial and frequent visual inspections of per NFPA. Inspection at close range sprinkler manufacturer regarding any random samples are recommended for can better determine the exact sprin- questions. corrosion-resistant sprinklers to verify kler condition and the long-term integ- Automatic sprinkler systems are rec- the integrity of the corrosion-resistant rity of the corrosion-resistant material, ommended to be inspected, tested, material of construction. Thereafter, which can be affected by the corrosive and maintained by a qualified Inspec- annual inspections per NFPA 25 should conditions present. tion Service in accordance with local suffice. requirements and/or national codes. TFP171 Page 9 of 10 2-7/8"DIA. 2-7/8"DIA. (73,0 mm) (73,0 mm) 1/2"(12,7 mm) 5/8±1/4" 3/4"(19,1 mm) 1/2x1/8" (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) � r (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) I MOUNTING FACE OF (57,2 mm) ~ MOUNTING SPRINKLER PLATE I SPRINKLER PLATE FITTING FITTING 1/8" i j 1/8" (3,2 mm) 1 i _ .. (3,2 mm) /� rte. f � t MOUNTING , ! SURFACE Il, rl, SURFACE / �_ SERIES 1-1/4"(31,8 mm) SERIES 1-1/4"(31,8 mm) CLOSURE CLOSURE TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 5.6 K-FACTOR, 1/2 INCH NPT ----- 2-7/8"DIA. 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) I 1/2"(12,7 mm) r (15,9±6,4 mm) I , 2-1/4"DIA. 1/4"(6,4 mm) - (12,7±3,2 mm) + 2-1/4"DIA. ' 1/4'(6,4 mm) 1 �_ (57,2 mm) . (57,2 mm) FACE OF I MOUNTING I FACE OF MOUNTING SPRINKLER i ' PLATE SPRINKLER - PLATE FITTING FITTING / ,' j 1/8" 1/8" m 1 (3,2 mm) f / n (3,2 mm) JJir / % 1 f 1 MOUNTING //ll� MOUNTING '�• SURFACE / SURFACE Y__— Y__ _ CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm); TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT 8.0 K-FACTOR,3/4 INCH NPT Inspections of corrosion-resistant sprinklers are recommended at close WRENCH range, instead of from the floor level RECESS per NFPA. Inspection at close range WRENCH RECESS can better determine the exact sprin- (END"A"USED FOR X11 kler condition and the long-term integ- 1/2"NPT MODELS) I% rity of the corrosion-resistant material, % i TFP171 Page 10 of 10 P/N 57 - XXX - X - XXX 1 I MODEL/SIN SPRINKLER TEMPERATURE FINISH RATINGS 330 2.8K UPRIGHT(1/2"NPT) TY1131 1 NATURAL BRASS 135 135°F(57°C) 331 2.8K PENDENT(1/2"NPT) TY1231 4 WHITE POLYESTER 155 155°F(68°C) 340 4.2K UPRIGHT(1/2"NPT) TY2131 3 WHITE(RAL9010)' 175 175°F(79°C) 341 4.2K PENDENT(1/2"NPT) TY2231 9 CHROME PLATED 200 200°F(93°C) 370 5.6K UPRIGHT(1/2"NPT) TY3131 7 LEAD COATED 286 286°F(141°C) 371 5.6K PENDENT(1/2"NPT) TY3231 390 8.0K UPRIGHT(3/4"NPT) TY4131 391 8.0K PENDENT(3/4"NPT) TY4231 360 8.0K UPRIGHT(1/2"NPT) TY4831' *Eastern Hemisphere sales only. 361 8.0K PENDENT(1/2"NPT) TY4931' TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited responsible for sprinkler system design errors or inaccurate or incomplete infor- Ordering Warranty mation supplied by Buyer or Buyer's Procedure representatives. Products manufactured by Tyco Fire In no event shall TFSBP be liable, in Contact your local distributor for Suppression & Building Products contract, tort, strict liability or under availability. When placing an order, (TFSBP) are warranted solely to the any other legal theory, for incidental, indicate the full product name and Part original Buyer for ten(10)years against indirect,special or consequential dam- Number(P/N). defects in material and workmanship ages,including but not limited to labor when paid for and properly installed charges,regardless of whether TFSBP Sprinkler Assemblies with NPT and maintained under normal use and was informed about the possibility of Thread Connections service. This warranty will expire ten such damages, and in no event shall Specify: (Specify Model/SIN),from date is of shipment for toby TFSBP's liability exceed an amount Response, (specify K-factor), spec(specify equal to the sales price. temperature ucts or components manufactured by p.rature rating), Series TY-FRB companies not affiliated by ownership The foregoing warranty is made in lieu (specify Pendent or Upright)Sprinkler with TFSBP or for products and corn- of any and all other warranties,express with(specify type of finish or coating), ponents which have been subject to or implied,including warranties of mer- P/N(specify from Table D). misuse, improper installation, corro- chantability and fitness for a particular Recessed Escutcheon: sion,or which have not been installed, purpose. Specify: Style (10, 20, 30, or 40) maintained, modified or repaired in This limited warranty sets forth the Recessed Escutcheon with (specify`) accordance with applicable Standards exclusive remedy for claims based on finish, P/N (specify). of the National Fire Protection Associa- failure of or defect in products, materi- tion, and/or the standards of any other als or components,whether the claim is Sprinkler Wrench Authorities Having Jurisdiction. Mate- made in contract, tort, strict liability or Specify: W-Type 6 Sprinkler Wrench, rials found by TFSBP to be defective any other legal theory. P/N 56-000-6-387. shall be either repaired or replaced,at TFSBP's sole option. TFSBP neither This warranty will apply to the full Specify: W-Type 7 Sprinkler Wrench, assumes, nor authorizes any person extent permitted by law.The invalidity, P/N 56-850-4-001. to assume for it,any other obligation in in whole or part,of any portion of this •Refer to Technical Data Sheet TFP770. connection with the sale of products or warranty will not affect the remainder. parts of products.TFSBP shall not be Copyright©2007-2010 Tyco Fire Suppression&Building Products.All rights reserved. RECEI U ED NOV 1 9 2012 CITY OF TIGARD BUILDING DIVISION uttt /i' — C— — —� -_ -_ 4 ire 1-14.t.,11 c aclek L y Gr j r - A E+aT, 4 A0/ pzwLt 2 Fitt Pene/e 1-7c �s -- o evarn 4 A Break rro— A C �I r I 'A . I �wF n /' fieS V - • .. Cr`pwn re _se; .1-1. r 67-1 PAysicJ -rAer-a1° Y 9 O z "so ri ("re 411 r/_, z O J L1/ Do r*,r e, tit a R oi-z q -2 z O a 9 a r-ol, C.)/ ��3 - 777 - S'c73 0 4/9v ,6., f"/, zo/ z.