Permit CITY OF TIGARD ELECTRICAL PERMIT 1111 s ' COMMUNITY DEVELOPMENT Permit #: ELC2012 -00669 T1GARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 11/26/2012 Parcel: 2S 101 AB90000 Jurisdiction: TIGARD Site address: 12011 SW 70TH AVE Project: CH Physical Therapy Subdivision: 2012 -009 PARTITION PLAT Lot: 1 Project Description: TI buildout (1) 200 amps or less (10) branch circuits for buildout (2) low voltage for Audio and Stereo System and Data Telecommunications Contractor: CHARGED ELECTRIC LLC Owner: RED ROCK CREEK CONDOMINIUM 12175 SW SUMMER CREST DR OWNERS OF ALL UNITS TIGARD, OR 97223 00000 PHONE: 503 - 380 -4364 PHONE: FAX: FEES Quantity Description Date Amount 2 ea Limited Energy 11/26/2012 $150.00 Specifics: 1 ea Services or Feeders - 200 11/26/2012 $100.70 amps or less Type of Use: COM 10 crt Branch Circuits w /Purchase 11/26/2012 $74.20 Class of Work: ALT Service or Feeder 1 ea 12% State Surcharge - 11/26/2012 $38.99 Type of Const: Electrical Occupancy Grp: Total $363.89 Required Items and Reports (Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR :5 -001-00i. You m- obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.80 332.2344. Issued By: AA _I .. Permittee Signature: OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale, lease or rent. OWNER'S SIGNATURE Date: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR. ELEC' Date: LICENSE NO. Call 503.639.4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Electrical Permit Application FOR OFFICE USE ONLY ' City of Tigard Rec eived C Permit No r}. ' � 4 tv q 13125 SW Hall Blvd., Tigard,OR ` ` Plan Review y1 at? II 9 . C ' Phone: 503.718.2439 Fax: 503.5'8. � . t Date/By: Other Permit 4a/9 /tr�r ODeZI Inspection Line: 503.639.4175 NOV 2 6 2012 Date Ready/By: Juris' ® See Page 2 for Internet: www.tigard- or.gov 'r ®per Notifred/Method: -nO Supplemental Information TYPE OF oFTIGARD PLAN REVIEW INew construction ❑ Addition/alt tin M 11:310 I Please check all that apply (submit 2 sets of plans w /items checked below): ❑ Service or feeder 400 amps or more ❑ Building over three stories. ❑ Demolition ❑ Other: where the available fault current ❑ Marinas and boatyards. CATEGOY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑ Floating buildings. less to ground, or exceeds 14,000 ❑ Commercial -use agricultural El I - and 2- family dwelling C ommercial/industrial ❑ Accessory building amps for all other installations. buildings. El Multi - family ❑ Master builder ❑ Other: ❑ Fire pump. ❑ Installation of 75 KVA or JOB SITE INFORMATION AND LOCATION ❑ Emergency system. larger separately derived system. ❑ Addition of new motor load of ❑ "A ", "E ", "I -2 ", "1 -3 ", Job no.: Job site address: /7,0 100HP or more. occupancy. r' I I ❑ Six or more residential units. ❑ Recreational vehicle parks. City/State /ZIP: "TR ) Qom!^ )., 0 • ❑ Health -care facilities. ❑ Supply voltage for more than ❑ Hazardous locations. 600 volts nominal. Suite/bldg. /apt. no.: Project name: , � Pk / i e.o. 1 'r1, '- P r,, ❑ Service or feeder 600 amps or more. e j FEE SCHEDULE Cross street/directions to job site: )L D . v"0,..,4./ - lv., Description I Qty. I Fee. I Total I ' /_ New residential single- or multi - family dwelling unit. Includes attached garage. Subdivision: Lot no.: 1,000 sq. R. or less 168.54 4 Ea. add' 1 500 sq. R. or portion 33.92 1 Tax map /parcel no.: Limited energy, residential 75.00 2 . DESCRIPTION OF WORK (with above sq. ft.) Limited energy, multi - family 75.00 2 -T- J J \ 1 ,o V residential (with above sq. ft.) Services or feeders installation, alteration, and/or relocation 200 amps or less I 100.70 i (90,1c 2 ❑ PROPERTY OWNER ❑ TENANT 201 amps to 400 amps 133.56 2 Name: 401 amps to 600 amps 200.34 2 601 amps to 1,000 amps 301.04 2 Address: Over 1,000 amps or volts 552.26 2 City/State/ZIP: Temporary services or feeders installation, alteration, and /or y relocation Phone: ( ) Fax: ( ) 200 amps or less 59.36 1 201 amps to 400 amps 125.08 2 Owner installation: This installation is being made on property that I own which is not 401 amps to 599 amps 168.54 2 intended for sale, lease, rent, or exchange, according to ORS 447, 449, 670, and 701. Branch circuits — new, alteration, or extension, per panel Owner signature: Date: A. Fee for branch circuits with d ❑ APPLICANT ❑ CONTACT PERSON above service or feeder fee () 7.42 1 4, each branch circuit Business name: B Fee for branch circuits without service or feeder fee, first 56.18 2 Contact name: branch circuit Each add'I branch circuit 7.42 2 Address: Miscellaneous (service or feeder not included) Cit /State /ZIP: Each manufactured or modular 67.84 2 y dwelling, service and/or feeder Phone: ( ) Fax: : ( ) Reconnect only 67.84 2 Pump or irrigation circle 67.84 2 E - mail: Sign or outline lighting 67.84 2 CONTRACTOR Signal circuit(s) or limited- energy 4 Business name: CVO ) G ( ` ...` IF <c...... panel, alteration, or extension. - Page 2 2 �� Each additional inspection over allowable in any of the above Address: `Z 1 y. - £ / .) �, / f " c y_ 6.4 (/ l• Additional inspection (1 hr min) 66.25/ hr City /State /ZIP: - (9 �Lt Z C 7.-2.75 ' Investigation (1 hr min) 66.25/ hr , /^ r ( (9 " I / Industrial plant (1 hr min) 78.18 / hr Phone: (5 ) 3, s / 2 4' Fax ( ) Inspections for which no fee is 90.00/ hr `r J specifically listed (A hr min) CCB Lic.: / 1 /I 3 1 Electrical Lic.: dilli7.5 , Suprv. Lic.: s y3 j ELECTRICAL PERMIT FEES Subtotal: Suprv. Electrician signature, required: L6 Plan review (25% of permit fee): Print name: c„, H- /26, h of ( Date: I t- Z b -1 2, State surcharge (12% of permit fee): TOTAL PERMIT FEE: 3 ( Authorized signature: This permit application expires if a permit is not obtained within 180 / days after it has been accepted as complete. �� Print name: �, h �� h I I / Date: �/ Z 6 - I �- • Number of inspections allowed per permit. (( \ 11 \Building\Permits\ELC- PermitApp.doc 07/01/10 440- 4615T(1 I /05 /COM/WEB Electrical Permit Application - City of Tigard Page 2 - Supplemental Information LIMITED ENERGY PERMIT FEES: RESIDENTIAL WORK ONLY: Fee for all residential systems combined .. $75.00 Check Type of Work Involved: ❑ Audio and Stereo Systems* ❑ Burglar Alarm ❑ G arage Door Opener* ❑ Heating, Ventilation and Air Conditioning System* El V • acuum Systems* ❑ Other: COMMERCIAL WORK ONLY: Fee for each commercial $75.00 system • (SEE OAR 918- 309 -0000) Check Type of Work Involved: Audio and Stereo Systems ❑ Boiler Controls El Clock Systems Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation El Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls El Outdoor Landscape Lighting* ❑ Protective Signaling El Other Total number of commercial systems: IV *No licenses are required. Licenses are required for all other installations I: \ Building \Permits\ELC- PermitApp.doc 07/01/10