Loading...
Permit (30) CITY OF TIGARD PLUMBING PERMIT 2 COMMUNITY DEVELOPMENT Permit#: PLM2018-00139 T f C.,3A R.t.) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/24/2018 Parcel: 1 S 136DA02400 Jurisdiction: Tigard Site address: 11123 SW 68TH PKWY Project: RPC Tigard Storage Subdivision: WAY LEE Lot: 1 Project Description: Site utilities for a new 122,076 sq.ft.3-story temperature controlled self storage building with basement:(5)catch basins,(2)manholes,88 ft.of sanitary sewer,755 ft.of storm sewer,52 ft.of water service,(1)backflow preventer, and(8)roof drains. Contractor: NUTTER CORPORATION Owner: RPC TIGARD 68 LLC 7211-A NE 43RD AVE 2101 CEDAR SPRINGS RD STE 1600 VANCOUVER,WA 98661 DALLAS, TX 75201 PHONE: 360-573-2000 PHONE: FAX: FEES Quantity Description Date Amount 5 ea Catch Basin or Area Drain 04/13/2018 $93.80 Specifics: 2 ea Manholes 04/13/2018 $37.52 88 If Sanitary Sewer 04/13/2018 $62.54 Type of Use: COM 755 If Storm Sewer 04/13/2018 $325.18 Class of Work: NEW 52 If Water Service 04/13/2018 Type of Const: $62.54 8 ea Roof Drain(Commercial) 04/13/2018 $100.08 Occupancy Grp: 1 Plan Review 04/13/2018178.23 Stories: $ 1 12%State Surcharge- 04/13/2018 $85.55 Plumbing 1 ea Backflow Preventer 04/13/2018 $31.27 Total $976.71 Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions/ to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: ,,<2 ✓ �i/ ./ ' Permittee Signature: ` \ 1116 l s Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Plumbing Permit Application Site Utilities 'rou OFFICE rh: Plumbing Permit Application - City of Tigard Page 2 -Supplemental Information Fee Schedule: Residential Fire Suppression Systems: Site Utilities Qty. Fee(ea) Total' Square Footage: Permit Fee: Footing drain-1"100' 50.03 0 to 2,000 $121.90 Footing drain-each additional 100' 37.52 2,001 to 3,600 $169.69 Sewer-1st 100' 62.54 3,601 to 7,200 $233.20 1 62.54 7,201 and greater $327.54 Sewer-each additional 100' 37.52 Water Service-1st 100' 1 62.54 62.54 Water Service-each additional 100' 37.52 Medical Gas Systems: Storm&Rain Drain-1st 100' 62.54 Valuation: Permit Fee: 62.54 $1.00 to$5,000.00 Minimum fee$72.50 Storm&Rain Drain-each additional 100' (\ ,c3.A.6 37.52 23-1-i-2 $5,001.00 to$10,000.00 $72.50 for the first$5,000.00 and$1.52 for Other Inspections or Fees Qty. Fee(ea) Total each additional$100.00 or fraction thereof,to Inspection of existing plumbing or for and including$10,000.00. which no fee is specifically indicated 90.00/hr $10,001.00 to$25,000.00 $148.50 for the first$10,000.00 and$1.54 for each additional$100.00 or fraction thereof,to (minimum charge-1/2 hour) and including$25,000.00. Inspections outside of normal business 90.00/hr $25,001.00 to$50,000.00 $379.50 for the first$25,000.00 and$1.45 for hours(minimum charge-2 hours) each additional$100.00 or fraction thereof,to Reinspection Fees 90.00/hr and including$50,000.00. Additional plan review for revisions 90.00/hr $50,001.00 and up $742.00 for the first$50,000.00 and$1.20 for (minimum charge-1/2 hour) each additional$100.00 or fraction thereof. Subtotal: Commercial Fixture Work: Are you capping,adding or replacing fixtures? If"yes", please indicate work performed by fixture. Failure to accurately report fixtures could result in increased sewer fees*. Quantity by Fixture Type Plan Review for PlumbingInstallations Fixture Type for Replace/ Work Performed: Capped Added Retate Plan review is required for any of the following. Baptistry/Font Please check all that apply. Bath Tub/Shower 0 Any new commercial building with water service 2"and -Jacuzzi/Whirlpool greater,except systems designed and stamped by licensed Car Wash -Each Stall engineer. -Drive Thru 0 New exterior plumbing site utilities for any complex structure Cuspidor/Water Aspirator as defined in OAR918-780-0040. Dishwasher -Commercial a/Medical gas and vacuum systems for health care facilities. -Domestic LYJ Any multipurpose fire sprinkler system. Drinking Fountain 0 Any complex structure as defined in OAR918-780-0040. Eye Wash Floor Drain/sink -2" Submit 2 sets of plans with any of the above. -3" Isometric or Riser Diagram Car Wash Drain Garbage Domestic-non-food 0 Isometric or riser diagram is required for new buildings Disposal -Domestic-food related that meet the qualifications above. -Commercial-food related -Industrial-food related Ice Mach./Refrig.Drains Oil Separator(Gas Station) Comments regarding fixture work: Rec.Vehicle Dump Station Shower -Gang -Stall Sink/Lav -Non-food related -Bradley -Commercial-food related -Service Swimming Pool Filter washer-Clothes *Note: If the fixture work under this permit results in an Water Extractor increase of sewer EDUs,a sewer permit will be issued and Water Closet-Toilet fees assessed for the sewer increase must be paid before the Urinal plumbing permit can be issued. Other Fixtures: C:\Users\dragelinj\Desktop\5077 68th Parkway Storage\PLMU PermitApQ.doc f Site Utilities — Plumbing Permit Application Plan Submittal Requirements TIGARD A plumbing permit for site utility plumbing work is required for sanitary sewer, storm sewer and potable water systems on private property. 1. SITE PLAN and vicinity map showing the geographic location (fully dimensional, drawn to scale) labeled with: A. E( map&tax lot# Er project name E'site address ❑ suite number [d zoning [1' applicant name 2 phone number B. North arrow. C. Scale (architectural or engineering only). D. Street names. E. Building pads with project location. 2. PLUMBING PLANS-Two (2) complete sets, civil only. All details listed below shall be incorporated into the plumbing plans: A. Storm drainage plan showing: 1) Finish elevations throughout the developed site. 2) Grade breaks determining area serving each catch basin. 3) Location of catch basins. 4) Pipe size. 5) Type of material. 6) Slope of piping. 7) Manholes and field drains. 8) Cleanouts provided for each 100 feet or fraction thereof. 9) Roof drain laterals specifying cleanouts at each upper terminal. 10) Location of existing or proposed connection to a public sewer line. B. Utilities plan showing: 1) Sanitary sewer line location,pipe size, type of material, slope of piping,manholes and cleanouts provided as required for storm. 2) Size and location of domestic water piping and drainage. 3) Proposed location of connection to a public water or sanitary sewer line. L\Building\Permits\PLMF-PermitApp.doc 12/30/05 .�IF Submittal Transmittal AKS Engineering & Forestry ! 12965 SW Herman Rd, Suite 100 Tualatin, OR 97062 FROM: John Christiansen AKS Engineering & Forestry TO: n/a 12965 SW Herman Rd. City of Tigard Suite 100 13125 SW Hall Blvd Tualatin, OR 97062 Tigard, OR 97223 johnc@aks-eng.com 503-639-4171 503-563-6151 PROJECT: 68th Parkway Storage DATE SENT: 5077 3/28/2018 SUBJECT: Plumbing Permit ID: 00052 PURPOSE: For Signature VIA: Delivered by AKS Engineering CONTENTS QTY: DATED DESCRIPTION: ACTION: 2 3/27/2018 Construction Plans- 22x34 QTY: DATED DESCRIPTION: ACTION: 1 3/27/2018 Check#29010 For fee in the Amount of ..__. �,,,, d $856.42 -lam /0/4/1,/ re-ay . 3/Reh .� 2 QTY: DATED DESCRIPTION: 1 3/27/2018 Plumbing Permit Application ACTION: Page 1 of 1 Branden Taggart From: Branden Taggart Sent: Friday, May 04, 2018 11:19 AM To: 'Brandon Cooke' Cc: Dale Beggs;#Building Permit Technicians Subject: RE: Extra Space Storage Site Utilities Permit: PLM2018-00139; 11123 SW 68th Pkwy Attachments: Branden Taggart2.vcf Hi Brandon, Perlo Construction does not have a plumbing license. We will need to have your plumbing contractor's license information before we can issue this permit. I see that the fees have been paid online, so this is all that is required to pick up the permit and plans. You are welcome to send your plumbing contractor in to pick up the permit, and at that time we can get their license information. Thank you, Branden Taggart a City of Tigard $ Senior Permit Technician Community Development rIGAKO 13125 SW Hall Blvd Tigard, OR 97223 (503)7:1€1-2449' brandent@tigard-or.gov From: Brandon Cooke [mailto:bcooke@rosewd.com] Sent: Friday, April 27, 2018 12:52 PM To: Branden Taggart<brandent@tigard-or.gov>; #Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Cc: Dale Beggs<dbeggs@cocommercial.net> Subject: RE: Extra Space Storage Site Utilities Permit: PLM2018-00139; 11123 SW 68th Pkwy Here is the contractor's license information. Perlo CCB 189245 From: Brandon Cooke Sent: Friday, April 13, 2018 5:32 PM To: 'Branden Taggart' <brandent@tigard-or.gov>;#Building Permit Technicians<TigardBuildingPermits(wtigard-or.gov> Cc: Dale Beggs<dbengs@cocommercial.net> Subject: RE: Extra Space Storage Site Utilities Permit: PLM2018-00139; 11123 SW 68th Pkwy Branden, The balance has been paid online. I have attached the receipt for your reference. I will provide the contractor's license information ASAP. 1 Thank you, ROSEWOOD PROPERTY COMPANY Brandon Cooke Acquisitions Manager 2101 Cedar Springs Road, Suite 1600, Dallas, TX 75201 214-849-9041 direct&fax ( 512-750-4552 cell bcooke(arosewd.corn email http://rosewoodproperty.corn/website http://rosewd.com/website This e-mail(including attachments)is covered by the Electronic Communications Privacy Act, 18 U.S.C. §§2510-2512, is confidential and may be legally privileged. If you are not the intended recipient,you are hereby notified that any retention,dissemination,distribution or copying of this communication is strictly prohibited. If you have received this communication in error, please immediately notify us by telephone. This communication is for informational purposes only. From: Branden Taggart [mailto:brandent@tigard-or.gov] Sent: Friday, April 06, 2018 1:18 PM To: Brandon Cooke<bcooke@rosewd.corn> Cc:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Subject: Extra Space Storage Site Utilities Permit: PLM2018-00139; 11123 SW 68th Pkwy Hi Brandon, Your site utilities permit for Extra Space Storage (RPC Tigard Storage) is ready to issue. The balance due is$976.71, and the permit fees can be paid online now at https://aca.accela.com/TIGARD/Default.aspx or in person between the hours of 8:00 a.m. and 4:30 p.m., Monday through Thursday. We are closed on Fridays. If you pay online, please notify us at tigardbuildingpermits@tigard-or.gov. Also we will need your contractor's license information prior to issuing this permit. If you have any questions, please let me know. Thanks, Branden Taggart 10/ City of Tigard .,; Senior Permit Technician Community Development it 13125 SW Hall Blvd Tigard,OR 97223 (503)718-2449 bran dent i tigard-o r.gov DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail 2 • may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E-mails are retained by the City of Tigard in compliance with the Oregon Administrative Rules "City General Records Retention Schedule." 3