Plans (45) DEC. 6. 2007/ 8 6032397038 603 - 5 O. 8682 6P. 17 h i r Installat Manual FB- IOM -1.0 7 -27 -06 Fan Powered Terminals VAV Term in&- - °c - ov 7 /D /6 a $1,-) Rd � J Receiving inspection The diameter of the inlet duct "p" in low voltage controls from the side of the Inches must be equal to the listed size of unit, and line voltage motor controls or After unpacking the terminal, check it for the terminal; e.g. a duct that actually electric heat section (if so equipped) shipping damage. If any shipping measures 8 inches must be fitted to a from the rear or discharge of the unit. , damage is found, report it Immediately size 8 terminal. The inlet collar of the to the delivering carrier. Store units in a terminal is made 1/8" smaller than listed For bottom access panel removal, 3" size in order to fit inside the duct (see minimum vertical clearance below the clean dry location and do not stack more ( than four high. Figure 1). unit is required, plus sufficient horizontal clearance to slide the access panel clear Caution: Do not use the inlet collar, Important: Do not insert duct work of the bottom of the unit. Horizontal damper shaft, flow sensor or air inside the inlet collar of the clearance is dependent on access panel tubing as a handle to lift or move assembly. dimensions as indicated on product assembly. Damage to the unit or submittals. controls may result. Inlet duct should be Installed in accordance with SMACNA guidelines. For low voltage control enclosure Before installation, remove fan packing Rectangular discharge opening is access, a minimum of 18" is and all foreign material from the unit. designed for flanged duct connections. recommended. Specific control Check the blower wheel for free rotation. Fasten and seal by method prescribed enclosure location is indicated on In the Job specification. product submittals. Panel for low voltage enclosures are removable (not hinged). Supporting the Assembly If single -point electronic velocity sensor For line voltage motor controls or electric is used, 3 to 5 Inlet duct diameters of heat control access, a minimum of 36" Suspend the unit from the building straight duct should be provided at the should ba provided to allow full opening terminal inlet, of hinged access doors. Specific location structure in a horizontal plane with the is indicated on product submittals. access panels facing downward. Minimum Access Important: These recommendations Do not obstruct the access panels do not preclude NEC or local codes with support channels or straps. that may be applicable, which are Fan Powered terminals require sufficient One inch Ion sheet metal screws can clearance to service the fan blower the responsibility of the installing g assembly and internal actuator (if so contractor. be used to penetrate the casing (see Figure 1). Use the support method equipped) from the bottom of the unit, prescribed for the rectangular duct on the job specifications. Unit may be =4-' /0 ''' Straps equipped with optional hanging brackets (see Figure 2). Hanger rod up to 7/16" ( C re w S / & &/- Si7O? diameter may be used. Note: If equipped with pneumatic .- controls, or unit is parallel fan type — - _L. l (Model TOP or FLP), the terminal must Discharge `1 l 41 Air be mounted right side up. It must be I _# Flow level within ±10 degrees of horizontal, ' both parallel to the air flow and at the Access Panel right angle of air flow. The control side of (Entire Bottom Is the terminal is labeled with an arrow Figure 1. Removeable) indicating UP. Hanger Rod Duct Connections i Optional Hanger Slip each inlet duct over the Inlet collar Bracket of the terminal. Fasten and seal the connection by the method prescribed by the job specification. i t ifii Discharge 11 11, 4 Air Flow • Figure 2.