Loading...
Plans (151) FPS2015 - 00154 d dJ CD CD u1j, AmEIVED �. coc OCT 5 2015 0 CITVOFTIGARI) Q= BUILDING DIVISION Q, L cn cn OLN TOWER LINC o�c S2 SOU uj Q) � U-1W> N MYW G co G7 m v m m RESTROOM NOTIFICATION e�. v FIRE ALARM SYSTEM m ,c N W W SITE INS TALLER DRAWING INDEX DWG# DESCRIPTION LINCOLN TOWER CAPITOL ELECTRIC FA-001 COVER SHEET FA-002 GENERAL INFORMATION 10260 SW GREENBURG RD 11401 NE MARX ST FA-101 DEVICE PLACEMENT PLAN - 2ND FLR 1 FA-102 DEVICE PLACEMENT PLAN - 9TH FLR TIGARD , 0 97223 PORTLAND , OR 97220 FA-103 DEVICE PLACEMENT PLAN - 12TH FLR PHONE 971 -506-3072 FA-701 WIRING TYPICALS CONTACT: DAN WILSON e- WNERGENERAb � L ERA �TDR SHORENSTEIN REALTY SERVICES RUSSELL CONSTRUCTION Q 10220 SW GREENBURG RD 20915 SW 105TH :s 0 0 0 PORTLAND , OR 97223 TUALATIN , OR 97062co �= REVIEWED FOR CODE COAULTANM LjL ' ca Approved: t>f-' 0 E OTC: [ w 0 0 Permit#: zo � �~ rn Address: V e�E O N 0 Site #: 8M 8By:: Date: CN 0 t �— a w w CV -� O cl� LU � 8 w OFFICE COPY —� (�! F- c� c O 2 Ic :z a) b z � occcQ 0 Jd ESE L LL c p N N R O ^ V'I Z a O LL W S �7 m N 0 Lu Q co O 0- L)U N W Y 2 U 0- 600 305 SW ROSEWOOD ST, SUITE A o LAKE OSWEGO, OR 97035 w Y =:) � N M N g W _ PHONE: 503-683-9000 z SERVICE: 503-683-9001 DRAWN BY: J.JOHNSON a ell1 CHECKED BY J.JONNSOiv s FAX. 503-675-6521 ISSUE DATE: 9/22/15 JOB#: PROJECT#: 448:987618601 SIMPLEXGRINNELL O 2015 TM SYSTEM: g a er. ma er. CO. FIRE ALARM SYSTEM if ze SHEET: SALES RE'PRESENTA T1 VE SCHEDULING ,DR4 WINGS PREPARED BY COVER SHEET N BRYAN ADAMS FAITH KASKE JEFF JOHNSON 503-683-9000 503-683-9000 NICET LEVEL III #121846 0 bradams@simplexgrinnell .com fkaske@simplexgrinnell.com _ X FA 001 C-13 s' F 4 2 SYSTEM DESCRIPTION SCOPE OF WORK SYMBOL KEY �' GENERAL NOTES o� a CD, c OCCUPANCY TYPE: B BUSINESS GROUP FIRE ALARM SYMBOLS LEGEND 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SPRINKLER PROTECTION: BUILDING IS FULLY SPRINKLED SYMBOL D ESC R!PT!0 N M 0 D EL COMMONLY USED BAC K B OX, REFER ¢=� SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. TO DATA SHEET FOR OTHER OPTIONS Lu 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR c 3 DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT SIMPLEXGRINNELL IN A TIMELY MANNER SO AS NOT MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES AS SHOWN ON DRAWINGS. NAC EXTENDER PANEL ��. cl) Lo TO IMPAIR THE CONSTRUCTION SCHEDULE. f_N`AC_#j # DESIGNATES THE NAC PANEL NUMBER SIMPLEX 4009-9201 SUPPLIED BY SIMPLEXGRINNELLiE ;c"",� 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING DESIGN IS FOR THE FIRE ALARM NOTIFICATION IN THE OUTLINED AREA OF WORK. SIMPLEXGRINNELL W / 6.2AH BATTERY SET SIMPLEX 2081-9272 o A5 REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY WAS NOT SUPPLIED WITH THE EXISTING RESTROOM NOTIFICATION CIRCUITING OR POWER SUPPLY SMOKE SENSOR / BASE SIMPLEX 4098-9714 � c AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. INFORMATION. NO CALCULATIONS COULD BE GENERATED. O SIMPLEX 4098-9792 BASE 4" OCTAGONAL BOX 1 1 j2" DEEP E co aOT 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL. BE USED FOR s INSTALLATION. ALL NEW WIRING TO BE CLASS B. U o 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A , wW Y BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICEWH WALL MOUNT MULTI-CANDELA STROBE ONLY, WHITE WHEELOCK STNV 4 SQUARE BOX 1 1/2" DEEP oYujco ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO # " " g = CANDELA RATING PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO SIMPLEXGRINNELL NO LATER THAN 7 DAYS AFTER FINAL TEST. ® WALL MOUNT MULTI-CANDELA STROBE ONLY WHEELOCK RSS-24MCW-FW 4" SQUARE BOX 1 1/2" DEEP 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER. # = CANDELA RATING 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED SIMPLEXGRINNELL TECHNICAL REPRESENTATIVE. 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE WALL MOUNT MULTI-CANDELA STROBE ONLY RED SIMPLEX 4906-9101 4" SQUARE BOX 1 1j2" DEEP FIRE ALARM INSTALLER. # =CANDELA RATING v 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL., CEILING, AND ROOF ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. CEILING MOUNT MULTI-CANDELA STROBE ONLY WHITE SIMPLEX 4906-9104 HANDY BOX 1 1/2- DEEP 11. INSTAIlA11ON OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND C / NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NEC. # =CANDELA RATING FIRE ALARM APPLICABLE CODES & STANDARDS 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC). B CEILING MOUNT SPEAKER EXISTING EXISTING 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE C ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE END-OF-LINE RESISTOR 3.3K (EOL) SIMPLEX 4081-9002 FPLP. END-OF-LINE RESISTOR 4.7K (EOL) SIMPLEX 4081-9003 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATE MORE THAN ONE FLOOR OR CABLES INSTALLED IN OREGON FIRE CODE, 2014 EDITION AAAr END-OF-LINE RESISTOR 6.8K (EOL) SIMPLEX 4081-9004 VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET END-OF-LINE RESISTOR 10K (EOL) SIMPLEX 4081-9008 LOCATIONS. OREGON MECHANICAL SPECIALTY CODE, 2014 EDITION 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOOR SHALL BE INSTALLED IN ACCORDANCE WITH NOTE: EXISTING DEVICES SHOWN SHADED FOR REFERENCE. _ NFPA 70 ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE. OREGON ELECTRICAL SPECIALTY CODE, 2011 EDITION 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. NATIONAL FIRE ALARM CODE (NEPA 72), 2013 EDITION 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. x 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. E 22. MAINTAIN 40 PERCENT CONDUIT FILL RATIO AS PER NEC REQUIREMENTS. 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY, HOWEVER, ANY EXISTING CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. SIMPLEXGRINNELL MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. RISER DIAGRAM N L C G JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. H m WIRE SCHEDULE ABBREVIATIONS LEGEND W 3 V < v -5 3 AC = ABOVE CEILING HT = HEIGHT (RR) WH P C = CEILING MOUNTED HVAC = HEATING, VENTILATION, & AIR CONDITIONING 12TH FLOOR o E = EXISTING TO REMAIN IMS = INFORMATION MANAGEMENT SYSTEM o RC = EXISTING TO REMOVE AND COVER MAX = MAXIMUM II RD = EXISTING DEVICE TO BE RELOCATED MIN = MINIMUM WIRE ' RL = RELOCATED DEVICE N/A = NOT APPLICABLE FIRE ALARM YY I R E LIST RR = REMOVE EXISTING AND REPLACE W/NEW NAC = NOTIFICATION APPLIANCE CIRCUIT EXTENDER NDU = NETWORK DISPLAY UNIT WH CIRCUIT DESCRIPTION RISER RATED: FPLR ISINGLE CONDUCTOR THHN,TFFN PLENUM RATED: FPLP WP = WEATHERPROOF NEC = NATIONAL ELECTRICAL CODE V VISUAL/SIGNAL CIRCUIT SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE XP = EXPLOSION PROOF NFPA = NATIONAL FIRE PROTECTION ASSOCIATION 2V 2 CONDUCTOR 14 AWG AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH H = HIGH HUMIDITY NIG = NOT IN CONTRACT v Ov 3 SOLID ANIXTER PART NUMBER (2) #14 AWG ANIXTER PART NUMBER AFF = ABOVE FINISHED FLOOR NPU NETWORK PROCESSING UNIT Z �; FA-1402C-1-1 N-03-BX AREA=0.0097 SQ. INCH (EACH): FA-1402C-1-2N-03 AHJ = AUTHORITY HAVING JURISDICTION NTS = NOT TO SCALE ALM = ALARM PAP = PRE-ACTION PANEL (RR) CONDUIT SIZE CONDUCTOR AREA CONDUIT SIZE CONDUCTOR AREA: ANN = ANNUNCIATOR SCC = STATUS COMMAND CENTER 9TH FLOOR O Q 1 1/2" 0.12 SQ INCH * 1-1 j4" 0.60 SQ INCH 'kBMS = BUILDING MANAGEMENT SYSTEM SLC =' SIGNALING LINE CIRCUIT �- i� 3z4" 0.21 SQ INCH * 1-1/2" 0.82 SQ INCH 0 1 0.34 SQ INCH * 2" 1.34 SQ INCH - CBC = CALIFORNIA BUILDING CODE SMK = SMOKE o c * CD = (eg. 15CD) CANDELA SUPV = SUPERVISORY GENERAL NOTES: co to 407. FILL PER N.E.C. CSFM = CALIFORNIA STATE FIRE MARSHAL TAC = TRUEALERT ADDRESSABLE CONTROLLER ti1. DEVICES SHOWN ARE TYPICAL SEE FLOOR PLAN 0 THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED ELECTRICAL DET = DETECTOR TRBL = TROUBLE - a rn FOR QUANTITY AND LOCATION. CHARACTERISTICS AS WELL AS CODE REQUIREMENTS. ALTERNATE SUPPLIERS MAY BE DGP = DATA GATHERING PANEL TS = TAMPER SWITCH L m EOL = END OF LINE TYP = TYPICAL 2. ALL WIRING SHALL COMPLY WITH NFPA 70, ARTICLE cm SUBSTITUTED PROVIDING EQUIVALENT CHARACTERISTICS ARE MAINTAINED. ITEMS SUCH AS ca EPO = EMERGENCY POWER OFF LION = UNLESS OTHERWISE NOTED 760, POWER LIMITED SYSTEMS• t2V Of 1--. CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT FACP = FIRE ALARM CONTROL PANEL VCC = VOICE COMMAND CENTER 3. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. V W f p DESIGN OF THIS SYSTEM INSTALLATION. FATC = FIRE ALARM TERMINAL CABINET VT = VALVE TAMPER Q FBO = FURNISHED BY OTHERS WF = WATER FLOW REFERENCE https:,//www.anixter.com,(customerZtycofs FOR SG ANIXTER CABLE DATA FCC = FIRE COMMAND CENTERW (RR) WH o FAA = FIRE ALARM ANNUNCIATOR = WITH(eg. 1/2W) WATT KEYED "ods 2ND FLOOR _ FTR = FIRE ALARM TRANSPONDER W� = WITH OUT a TIE INTO EXISTING NOTIFICATION CIRCUIT. MAINTAIN SUPERVISION. FSD = FIRE SMOKE DAMPER O � W N 3 z W W fl O � m d DEVICE ADDRESSING LEGEND SEQUENCE OF OPERATION -j o o w- 0 z � U) zL.1..1 oCQ 0 NN CIRCUIT DESIGNATOR E 4009 NAC PANEL V=VISUAL OR A/V, H=AUDIBLE ONLY) e od- WHEN APPLICABLE w { } Al I- DEVICE DESIGNATOR w NAC 1 :V2- 1 CONTROL UNIT ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL $ VISUAL. AUDIBLE OR A/V DEVICE T 0 All, 11z, LL0 '3 a SYSTEM INPUTS A B C I D I E F I G I H I J K L M I N 0 1 P 1 Q R S T U V W X Y Z I AA AB AC I AD I AE AF I AG I AH AI I AJ I REMARKS Lu 1 1 E con 2 SMOKE SENSOR DETECTOR • • • * • « • • « « « « « 2 z c~n 3 MANUAL PULL STATION « • « • • • • • « • • 3 0 4 HEAT SENSOR DETECTOR • • • + « • • « 4 5 DUCT SENSOR DETECTOR • • • • • « • • • • « « 5 o 6 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR « • . « • • « • « 6 0 7 ELEVATOR LOBBY SMOKE DETECTORS IXC. MAIN FL.R. • « • • • + « • • • • • • • • « 7 8 ELEVATOR MECH. ROOM HEAT DETECTOR • • • • • « • • . « + « . « I . 181 = Q 9 ELEVATOR MECH. ROOM SMOKE DETECTOR • • • * • « • • « « • • « . « « 9 '9 101 ELEVATOR SHAFT HEAT DETECTOR • : « • « « « « « « « . 10 a 11 ELEVATOR SHAFT SMOKE DETECTOR • • • + • • + • • « 11 v a 12 ELEVATOR POWER MONITOR • • • o 12 0 13 FIRE PUMP RUNNING • • + • • « 13 w s 0) 14 FIRE PUMP POWER FROM ALTERNATE SOURCE « • • • • . 14 0 W �! 15 GENERATOR RUNNING • • • • • « 15 a E `- 16 GENERATOR FAULT • • • • + « 16 ; e 0 17 FIRE ALARM AC POWER FAILURE • • « a • • « 17 s Q 18 FIRE ALARM SYSTEM LOW BATTERY * • « 18 04 19 IR R FA • • • • « 19 s 201 CLASS B NOTIFICATION CIRCUIT NAC - SHORT • • • • . 1201 21 WATERFLOW SWITCH • • • • • + « 21Lu Z5 m 22 TAMPERSWITCH 0 • 0 • • • 22 DRAWN BY: J. JOHNSON 23 POST INDICATOR VALVE SWITCH • • • • 23 4 CHECKED BY J.JONNSON 25 25 ISSUE DATE: 9/22/15 26 1 1 1 261 JOB#: 27 27 PROJECT#: 448:987618601 s 2 2 - .2 SIMPLEXGRINNELL© 2015 E -- 29 29 30 30 SYSTEM: 1311 31 FIRE ALARM SYSTEM 1321 13A FS A I B C D E F G H I J K L M N 0 P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH AI AJI SHEET: N � 7 pr Ir. i5 GENERAL INFORMATION 25, a� s N m 3 fn W E t� v W m Q FA 002 X M - z ON Lo GENERAL NOTES: S, 1. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. �\ 2. SIMPLEXGRINNELL WAS NOT SUPPLIED WITH THE RESTROOM EXISTING NOTIFICATION tq �o CIRCUITING OR POWER SUPPLY INFORMATION. CI' o0 \/ Ln"' W w z a O a 3 T � Q � KEYED NOTES: `_ OTIE INTO EXISTING NOTIFICATION CIRCUIT. MAINTAIN SUPERVISION. , U)o x L Orno O0c OOc L 0Up o cr�Ln s N U U)w og a` L F �W: lA MYW Q D co U) w vJ N l d J N .3 1 2 3 4 5 6 7 8 9 10 L N C fO d a_ L_ T N O d a - a m d `o I I I I I I I I I `o m L _O a m m N E NAC2:V1-3 75 x d a E 75 \NAC2:V1-L AC2:V1-5 V C L C f0 a C3 - - - - - - - - - - - - 30 V i TO NAC2 75 0 V V U O V N _ - - - - - V NAC2-.V2-2 NAC :V1- - - 5 / \ 75 15 �NAC2:V1-1 T S 1 E V C 15� o NAC2:V1-4 TO NAC2 .o a t o - V 0 O M1-2 C2:V2-3 0 N I I �ARFA RK I I NAC2 M 1-1 15 � I I . V 15 O O NAC2:V2-4 tj \NAC2:V1 7 i C 2V w 151 O WH 2 ` 75 7 L 3 p Q - - - V (RR)1 XD WH 1 10K � - - - - - - - - (R T\, y 15 a AC2:V2-10 N NAC2:V1 8 "NAC2-V2-27 V 15 Q T 00w 76 r O 1 N V o E L V W o � z o o FAOrf o - - - - - - - - 75 - - - - O ZD 1) 10K / NAC2 V2-8 , NAC2 V2-6 m M 76 EOL V C O Lu Lu w N I I 75 I I I I I I I Z O W ~ o i d i �NAC2:V1-11 V C� 75O 0 75 V i C NAC2 \9 V 30 Z 2NAC2:V2-5 J C/) p 2V NAC2:V1-9 C zw � CQ L 30 J O I— �I NCAC :V1-10 0 0 C E Q � U W L E J m O U L/ 4 y � C .O O d' c Q c 0 m Z o Oa� z O O a 0 LL a W o U d m y 0 J7 W O C z � 4c/) O J � r O C U o W E 2 = o d m Q 0 O ¢ � a O E W Y c Q o O N r N 0 H O rn O W H z DRAWN BY: J.JOHNSON r a CHECKED BY J.JONNSON U)i ISSUE DATE: 9/22/15 d J JOB#: PROJECT#: 448:987618601 PLAN 0 NORTH SIMPLEXGRINNELL© 2015 E a o � SYSTEM: DEVICE PLACEMENT PLAN — 2ND FLR FIRE ALARM SYSTEMT C U t0 d SCALE: SHEET: 120 (IN FEET) DEVICE PLACEMENT PLAN - 2ND FLR U N � Q Nm o fn w E coW O w � Q U m FA-101 z o x QN of M a E E L c C d cn ON Lo GENERAL NOTES: CD Lo 1. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. 6;6 m 2. SIMPLIXGRINNELL WAS NOT SUPPLIED WITH THE RESTROOM EXISTING NOTIFICATION o� CIRCUITING OR POWER SUPPLY INFORMATION. 2"o Ln Ln C V W '? z v \ O�l N <ui L KEYED NOTES: C3 Ov ~ OTIE INTO EXISTING NOTIFICATION CIRCUIT. MAINTAIN SUPERVISION. "o x i opo o0� eoW00o t OT g v 0U0 Lu o `o H U U)0V Oa` L Fu')W� 50 pY� N D co U) w i a� a .3 - 1 2 3 4 5 6 7 8 9 10 y C f6 L d a_ L_ En Elm T t0 `o `m L_ T a m .2 t5 m `o I I I I I i I I I I 0 m t `o a m m N E U F-3 H a c c U' x m a E N a v L_ T C t0 T ami 0 a I I I I I T, b �q L L(y O IILhYI O d d E cg 0 v m a a N R 3 -L L 3 ! 3 v m 0 L_ O N C O a v m O UN d O I I 1 I I I d C C II 15 wil II d - O I I L 15 a I)v0 WH 2 z p 3 W(RR) 15 WH 5 m (R FSS w s p a coN a r- c B I DWIU UE N . o p m N o N E . ■ . w p W O Q ~ H N v o 6 - - - - - - - - - - - - - - O N o c I I I 1 1 I I Zuj UJI w ~ H T c VJ d L O 0 `s U U � o00 0 -c) zU Q _ w zoo o _I d 75 E tp N U aLu E I I I I 1 I I I I J_ 3 � LL 3 g C � O � h N of C Q C O _N t0 m Z o o c z `o o o �c m W c 3 0 U d } a mLu N a a Q E c U) 0 J W' c U o W E � o c Y 'c = o U a� Q r U iri d o a co O W � O Q m N U � E �— 0 F Lf) W Y c N M o u, r- L N o O d d p DRAWN BY: J.JOHNSON d a CHECKED BY J.JONNSON U) ISSUE DATE: 9/22/15 JOB#: E PLAN PROJECT#: 448:987618601 0 L NORTH SIMPLEXGRINNELL© 2015 E _a O U SYSTEM: DEVICE PLACEMENT PLAN - 9TH F L I p\ FIRE ALARM SYSTEM T m SCALE: SHEET: 0 (IN FEET) m DEVICE PLACEMENT PLAN - 9TH FLR N @ O N M o N w E W v h m 0 . U m W v Q U m XFA-102 z E r M d' m CL E s X E E GENERA NOTES: o 1. EXISTING DEVICES SHOWN SHADED FOR REFERENCE �� '6 g 2. SIMPLEXGRINNELI_ WAS NOT SUPPLIED WITH THE RESTROOM EXISTING NOTIFICATION v CIRCUITING OR POWER SUPPLY INFORMATION. � �� z da- uiC3a KEYED NOTES: 0 OTIE INTO EXISTING NOTIFICATION CIRCUIT. MAINTAIN SUPERVISION. O O M co WM — OT 0 :3 'n Cho ` W> a_ ca w O CMO..7 N 0 1 2 3 4 5 6 7 8 9 10 0 m m 5 a a a E _v 75 N75-8 N75-4 15 5-5 30 V � y I I t L�J`r I `` V i S C I I tI I I C�1� 0 15 75-6 V ` vv v s --�-_ N75- Ab — 5 g — - - - N75-3 - - - - - - - 75 V — _ 75 I 3 15 N75-7kmamEso - N75 1 TO TP _ SUITE _ ON_11TH V _ 1280 , - - - - - - - I - - - - - I It o 0 o SUITE VA kj 1 i o WH 15 120015 WH z 1 (RR) 1 � � ON 11TH FLR (RR SUITE E-- 1250 < co co 75 1225 -- co r Y m 04 75 N76-7 V cn S (RL} 75 76-2 IQ y W CD 15 N76-3 ► z 0 � - - - - - - - - � - - - - - H co _ W W I' - r V 0 RL 8 FS 3 6-6 G c N76-4 110 O z c V J (n 0 VZit o a) co 15 W Z O a J LL �- -I N 6- LL V g E w E - - - - - - - - - — — - m9m N N C O C W m W m Z - - O 0 LL m s a m 'e Q LLIE Cn F Z O d � U LLI D c Y c U � d Q U a g r w 8 o m o t, w Y o cs T CV o gpg rn b Lu z DRAWN BY: J.JOHNSON CL CHECKED BY J.JONNSONcr gISSUE DATE: 9/22/15 - JOB#: PLAN PROJECT#: 448:987618601 $ NORTH SIMPLEXGRINNELL 0 2015 SYSTEM: DEVICE P1 ACE M E NT PLAN — 12TH FLR FIRE ALARM SYSTEM SCALE: SHEET: 0 (IN FEET) DEVICE PLACEMENT PLAN- 12TH FLR 2 N ocm to w tU L � a i g Q U i5 FA-103 x Z a M C C DEVICE MOUNTING HEIGHT REFERENCE (PER NFPA 72) END—OF—LINE RESISTOR CODES A/C SUPPLY oZ VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMSOR RETURN NOTE: REFER TO PANEL/MODULE AND DEVICE INSTALLATION �� mU 1. MIN DISTANCE IN SLEEPING ROOMS IS 24 (610mm) FROM CEILING TO DIFFUSER THE 4 REQUIREMENT FOR SMOKE DETECTORS HAS INSTRUCTIONS FOR PROPER TERMINATIONS. TOP OF LENS FOR 1 10C STROBES WITHIN 16' OF THE PILLOW BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 u)� 2. 177CD STROBES, USED IN SLEEPING ROOMS, CAN BE.WITHIN THE 24" * USE WITH RETROFIT OR HIGH CURRENT MODULE �; 610mm MINIMUM DISTANCE FROM THE CEILING. THE HIGHER 4 NOTE: MEASUREMENTS Cm Li IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. 3' (MIN) (1 02m SHOWN ARE TO THE MODEL REFERENCE OHMS 1ST BAND 2ND BAND 3RD BAND 4TH BAND 5TH BAND WATTS CIRCUIT TYPE FIRE ALARM PANEL/MODULE dU 914mm MIN CLOSEST EDGE OF THE NUMBER 151 ( ) CEILING DETECTOR. 4081-9001 733-892 2.2K RED RED RED GOLD N/A 1/2 ANNUNCIATOR {4300) 4004, 4010 {TROUBLE} � Uuj N.O. INITIATING 4004*, 4004R, 4005*, 4006, FOR CEILING HEIGHTS LESS THAN 86" 2180mm , CEILING MOUNTED \ o ( ) NFPA 72 AUDIBLE APPLIANCE 4" PULL SMOKE HEAT 4100 $120 41000 ZAM 5 i Doo > > v > > , lz a4m m THE VISUAL LENS MOUNTING HEIGHT SHALL BE 6" MIN 152.4mm MIN SMOKE/HEAT (102mm 4081-9002 733-893 3.3K ORANGE ORANGE RED GOLD N/A 1 WATERFLOW, TAMPER ETC. 12 MAX ro . o o = 24 PT. 1/0 SWITCH TAMPER, 4605-7401 4100 SERIES .coo WITHIN 6" (150mrn) OF THE CEILING. AUDIBLE ONLY BELOW FINISHED CEILING DETECTOR {305mm MAX) � �oW,�, NEAT DETECTORS CURRENT LIMITED N.O. INITIATING 4090-9001 IDNET IAM (EOLR) vim, 90 MIN 2286mm MIN 4081-9003 733-896 4.7K YELLOW VIOLET RED GOLD N/A 1/2 ,� C> �oU ( ) ACCEPTED HERE NEVER HERE NOTIFICATION DACT 2080-9024 N.O. INITIATING 4004, 4005, IT _ oYu ABOVE FINISHED FLOORtg� x FM TSE (OTHER MOUNTING HEIGHTS SHALL 4081-9004 733-886 6.8K BLUE GREY RED GOLD N/A 1/2 N.O. SMOKE, HEAT, 4090-9001 IDNET IAM cl wATERFLOWTAMPERETC. 2i9p-9173 MAPNETI( 2 PT I o AUDIBLE/VISUAL PERMITTED BY THE AHJ PROVIDING IT N MEETS THE SOUND LEVEL OUTPUT REQUIRED. , , & VISUAL ONLY ) WALL MOUNTED 4-20MA ZAM TROUBLE CURRENT LIMITED N.O. INITIATING APPLIANCES TO EXIT DOOR SMOKE/HEAT 4081-9005 733-984 1.8K BROWN GREY RED GOLD N/A 1/2 (IN LINE) 4090-9001 IDNET IAM 5' (MAX.) DETECTOR {1524mm) 4081-9006 733-890 560!n GREEN BLUE BROWN GOLD N/A 1 N.C. INITIATING (EOLR) 4005*, 4090-9001 IDNET IAM SYNCHRONIZE MORE THAN DOOR TWO APPLIANCES IN ANY WIDTH 4100, 41000 FIELD OF VIEW. LESS 3 4081-9007 733-891 1.2K BROWN RED RED GOLD N/A 1 N.C. INITIATING (EOLR) 4005 (76mm) 4081-9008 733-894 10K BROWN BLACK ORANGE GOLD N/A 1/2 NOTIFICATION 4004, 4005, 4006, 4008, Ilf 1 4009, 4010, 4100, 410OU m 96" MAX (NFPA, ADA) 5., SIDE WALL 4081-9009 733-912 20n RED BLACK BLACK GOLD N/A 1 TO MR-101 RELAY COIL 4005 8 POINT 1/0 (2440mm MAX) (127mm) N.C. INITIATING ACROSS CONTACTS 4005*, 4090-9001 IDNET IAM REF. 80" MIN (IBC) ABOVE FINISHED FLOOR MANUAL 4081-9010 733-973 1 K BROWN BLACK RED GOLD N/A 1 24 PT. 1/0 (ACROSS CONTACTS) 4605-7401, 4100 SERIES (2032mm MIN) TO TOP OF LENS PULL 4090-9001 IDNET IAM CURRENT LIMITED N.O. INITIATING STATION (IN SERIES WITH CONTACT) REF. 96" MAX (IBC) 80" MIN (ADA) (2032mm MIN) FIRE 4081-9011 733-974 100n BROWN BLACK BROWN GOLD N/A 1/2 ANNUNCIATOR (N2) 4006, 4008, 4010 (2440mm MAX) 80" MIN (NFPA) (2032mm MIN) PHONE MAGNETIC 4081-9012 733-985 22K RED RED ORANGE GOLD N/A 1/2 SPEAKER CIRCUIT 4003 ABOVE FINISHED FLOOR TO BOTTOM OF LENS JACK DOOR 4081-9013 734-086 4.99K YELLOW WHITE WHITE BROWN BROWN 1/2 • HOLDER N.C. INITIATING ° 4081-9014 734-092 2.4K RED YELLOW RED GOLD N/A 1/2 4090-9001 IDNET IAM FINISHED (SECURITY MONITORING EOLR) w � WALL CURRENT LIMITED N.O. INITIATING NOTE: REFER TO THE PROPER DEVICE 4081-9015 734-093 1.5K BROWN GREEN RED GOLD N/A 1/2 4090-9001 IDNET IAM x INSTALLATION INSTRUCTIONS 48" MAX (ADA) (1219mm) (SECURITY MONITORING EOLR) FOR BACKBOX MOUNTING HEIGHT. 4081-9016 734-149 150K BROWN GREEN YELLOW GOLD N/A 1/2 48" MAX (NFPA, ADA) (1219mm MAX) FINISHED 4081-9017 734-171 3.9K ORANGE WHITE RED GOLD N/A 1 42" MIN (NFPA) (1067mm MIN) FLOOR 4081-9018 734-168 10K BROWN BLACK ORANGE GOLD N/A 1 70VRMS CONSTANT SUPV. NACS 4100-1260 MEASUREMENTS SHOWN ARE 378-090 8.2K GRAY RED RED GOLD N/A 1/2 SECURITY MONITORING EOLR 4100, 41000 s TO TOP OF PULL HANDLE 378-046 5.6K GREEN BLUE RED GOLD N/A 1/2 N.O. SECURITY MON. (SERIES) 4100, 4100U 378-069 12K BROWN RED ORANGE GOLD N/A 1/2 N.C. SECURITY MON. (SHUNT) 4100, 41 OOU 0 WHEELOCK WALL MOUNT MULTI—CANDELA STROBE ONLY PRODUCT INFORMATION (EXCEDER SERIES ST) _s SPECIFICATIONS: •HOUSING DIMENSIONS: 5.24' H X 4.58' W X 2.19' D (133mm X 116.33mm X 55.63mm) a •TEMPERATURE RANGE 37F TO 127F (0 TO 5O`C) •HUMIDITY RANGE 10% TO 93% NON-CONDENSING AT 100'F (38'C) 3 •COMPATABLE WITH SM AND DSM SYNC MODULES 1. INSTALL MOUNTING PLATE AS SHOWN TO A SINGLE-GANG, DOUBLE GANG, 4' SQUARE BACKBOX WITH THE PROVIDED PAN 3 HEAD SCREWS. OPENINGS FOR FLAT SCREWDRIVER • OPTIONAL SECURING SCREW REMOVAL (SEE STEP 4 BELOW) 3. IF IT DESIRED TO FURTHER SECURE THE DEVICE TO THE BASE, THEN ONE t OPTIONAL SCREW IS PROVIDED. TO INSTALL THIS SCREW PUNCH OUT THE SCREW HOLE LOCATED AT THE TOP OF THIS NICE. CURRENT DRAW 4. TO REMOVE THE APPLIANCE, PUSH A SMALL FLAT-BLADED SCREWDRIVER INTO THE SIDE OPENING. THE SCREWDRIVER MUST CLEAR THE SNAP STROBE CANDELA SETTINGS (CD) RELEASE OPENING BY AT LEAST 1/4- TO DISENGAGE THE SNAP. DO NOT z 2. IMPORTANT: DEVICE ONLY HAS ONE MOUNTING ORIENTATION. MATCH THE PRY OFF HOUSING WITH THE SCREW DRIVER. APPLY PRESSURE WITH O a o VOLTAGE 15 15/75 30 75 95 110 135 185 TOP OF THE BASE TO THE TOP OF THE DEVICE. SCREW DRIVER, INSERTED IN EITHER SIDE OPENING, AS SHOWN ABOVE W 16V 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 TO RELEASE THE HOUSING. % 18V 0.051 0.062 0.076 0.120 0.145 0.162 0.183 0.225 TO ADDITIONAL NAC DEVICES OR RETURN TO FIRE 24V 0.038 0.047 0.057 0.090 0.10910.12210.13710.1691 ALARM CONTROL PANEL FOR STYLE Z APPLICATION. a IF LAST DEVICE ON CIRCUIT IN A STYLE Y ro ado APPLICATION PLACE A 10K 1/2W END-OF-LINE m RESISTOR. rU co + - g T T Top N [r c Tw uv ■ - »� O��dO o�c� o uu p m a� po a� po CANDELA SELECTION 0 (Y � �..._. m J FROM FACP 24VDC NOTIFICATION04 uji APPLIANCE CIRCUIT OR Q © 0 Ll.l W FROM FACP 24VDC NON-CODED +( 000 12 NOTIFICATION APPLIANCE CIRCUIT J WITH WHEELOCK SM DSYNC MODULE OR 4— a p a 4 p O � OR PRECEDING DEVICE O � OO O� CAUTION: CHECK THAT THE INSTALLED PRODUCT WILL HAVE SUFFICIENT CLEARANCE p AND WIRING ROOM PRIOR TO INSTALLING BACKBOXES AND CONDUIT, ESPECIALLY II 'I O QU �P IF SHEATHED MULTICONDUCTOR CABLE OR 3/4' CONDUIT FITTINGS ARE USED. �J 0 C�V Q o ALTHOUGH THE LIMITS SHOWN FOR EACH MOUNTING OPTION COMPLY WITHJ z a-� THE NEC, COOPER NOTIFICATION RECOMMENDS USE OF THE LARGEST , BACKBOX OPTION SHOWN AND THE USE OF APPROVED S"DED FIELD WIRES, WHENEVER POSSIBLE, TO PROVIDE ADDITIONAL WIRING ROOM FOR EASY INSTALLATION UNIVERSAL MOUNTING BASE UMB UNIVERSAL MOUNTING BASE UMB _Q AND MINIMUM STRESS ON THE PRODUCT FROM WIRING. ( ) ( ) w ®CAUTION: DO NOT OVER TIGHTEN MOUNTING SCREWS. EXCESSIVE TORQUE CAN DISTORT w THE BASE AND MAY AFFECT OPERATION. 3 a c n w � w m w 3 � 4T3 6 C z W 0 m a z o LL m w m C3 uio CL ULij is > Y_ c U m m Q F_ c a. v co - � 77a Q � E C m C1 U) r g' N o G1 0 w z DRAWN BY: J.JOHNSON a CHECKED BY J.JONNSON cr ISSUE DATE: 9122115 � JOB#: PROJECT#: 448:987618601 s it SIMPLEXGRINNELL d 2015 SYSTEM: ` m� FIRE ALARM SYSTEM z SHEET: � m a m� WIRING TYPICALS , mo 00 ui m WE Ix FA-7010 , z � ; s a� L