Plans (22) S) I © 26Q0 S 1/4v' 62.(201 Pd. 7 I 0 c„,\I PPS Zei ( e - c0 o© 53 - Global Project Values: SILENT Project Name: Axiom xjnp, 1 Standby Hours:1 24 TS KNIGHT Project ID: 1096 + Oc.1'' Alarm Mins: I 5 Prepared By: Adam Sweet vr berating Factor: I 1.2 5495 Power Expander Calculations Date: I5 /3/2010 I %- Voltage Drop Warning Threshold % :I 10 Panel ID: 5495 (7A) I Model: Silent Knight 5495 Power Expander Max Circuit Current: 3 Amps Location: 7th Fir Elect Rm Volts: 24 VDC Max Panel Current: 6 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts a @ o Ckt.# Circuit Name /oDrop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 1 7A.1 0.000 1.155 #14 Solid 2.52 225 1.13 19.09 6.42% 2 7A:2 0.000 0.586 #14 Solid 2.52 245 1.23 19.68 3.55% 3 7A:3 0.000 1.320 #14 Solid 2.52 200 1.01 19.07 6.52% 4 Spare 0.000 0.000 #14 Solid 2.52 160 0.81 20.40 0.00% Aux 5495(1) Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 5495 5495 Power Expander 0.075 0.205 3.061 (Amps) Total Output Power Required Total Standby Current (Amps) 0.075 3.266 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 0.272 Total Alarm AH Required Total Combined AH Required 2.07 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.49 Panel ID: 5495(2) Model: Silent Knight 5495 Power Expander Max Circuit Current: 3 Amps Location: Volts: 24 VDC Max Panel Current: 6 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Circuit Name /oDrop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 1 5495(2) Circuit 1 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 2 5495(2) Circuit 2 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 3 5495(2) Circuit 3 0.000 0.000 #14 Solid 1.59 0.00 20.40 0.00% 4 5495(2) Circuit 4 0.000 0.000 #14 Solid 1.59 0.00 20.40 0.00% Aux 5495(2) Aux Power Out 0 000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 5495 5495 Power Expander 0.075 0.205 0.000 (Amps) Total Output Power Required Total Standby Current (Amps) 0.075 0.205 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 0.017 Total Alarm AH Required Total Combined AH Required 1.82 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.18 ®sK , i Circuit Configuration Project Information Project Name: Axiom Project ID: 1096 Prepared By: Adam Sweet Date: 5/3/2010 Ckt. Number: 1 Panel ID: 5495 (7A) Ckt. Name: 4.1.1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby _ Alarm Standby Alarm 7 RSS -24MCW / 75 0.000 0.165 0.000 1.155 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.155 Ckt. Number: 2 Panel ID: 5495 (7A) Ckt. Name: 4.1.2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 Simplex 4906 -9103 110cd 0.000 0.252 0.000 0.252 4 Simplex 4906 -9103 15cd 0.000 0.060 0.000 0.240 1 Simplex 4906 -9103 30cd 0.000 0.094 0.000 0.094 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.586 Ckt. Number: 3 Panel ID: 5495 (7A) Ckt. Name: 7A:3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 Simplex 4906 -9103 110cd 0.000 0.252 0.000 1.260 1 Simplex 4906 -9103 15cd 0.000 0.060 0.000 0.060 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.320 Ckt. Number: 4 Panel ID: 5495 (7A) Ckt. Name: Spare Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 FIRE SYSTEM ACCESSORY Model 5495 • Distributed Power Module i In an emergency, you need maximum power. . ' ;A ie t. , ..� The 5495 Distributed Power Module by Silent Knight is the most powerful and R" cost- effective power supply available today. It delivers 6 amps of notification appliance circuit power and built -in synchronization for appliances from System Sensor®,Gentex ®, AMSECO ®, Wheelock and Faraday — what you need to drive power -hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost - effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1- 800 -446 -6444. Model 5495 • Independent trouble relay Distributed Power Module • AC loss delay option shuts off power The 5495 is a 6 amp notification power to non - essential high- current _ expander that provides its own AC accessories like magnetic door power connection, battery charging holders circuit, and backup battery for use with • Built -in synchronization for fire and security controls such as the appliances from System Silent Knight Model 5208 Fire Control Sensor®,Gentex®, AMSECO ®, /Communicator. The 5495 is the cost- Wheelock and Faraday effective solution for powering • notification appliances required by the Stand alone operation Americans with Disabilities Act (ADA). • Lightweight design adds to ease of The 5495 has built -in ANSI cadence installation and reduces shipping pattern, which can upgrade older costs control panels that lack cadence • Operates with most polarized, UL capability. Listed notification devices • UL 864 & 1481 listed " "'' "' Features • UL Listed for 6 amps of notification • CSFM approved power • ANSI Cadence pattern output Model • Power supply's advanced switch capability built -in Distributed Power Module mode design reduces damaging heat and manages power up to 50% Connection to Local Fire Control more efficiently than other systems The 5495 may be connected to a local 4.7kd2 end -of -line resistors provided. • Dip switches allow for easy fire control which utilizes Class A or Since the 5495 draws very little power reconfiguration Class B type notification circuits from the control, it is possible to • 24 VDC filtered output voltage operating between 9 and 32 VDC. The connect one 5495 to each notification control panel's notification circuit is circuit on the control panel and still • Four power - limited notification provide full supervision of the outputs; 2 Class A or 4 Class B, or 1 connected to one of the inputs on the p rov su p p 5495. The control panel's notification notification circuits all the way back to _ Class A and 2 Class B the control panel. • Additional continuous auxiliary circuit end -of -line resistor is also connected across two terminals on the output 5495, which provides supervision . • 3 amps per output circuit between the 5495 and the fire control SILENT • 2 inputs; 2 Class B or 2 Class A panel. Polarized audible and/or visual KNIGHT • Ground fault detector /indicator notification devices are then connected to the 5495 signal circuits using the by Honeywell FIRE SYSTEM ACCESSORY Model 5495 2 Distributed Power Module Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 175 mA Battery charging • Low AC power Auxiliary capacity: 33.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32° to 120° F • Earth ground fault Notification 0° to 49° C • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x • EOL supervision trouble or configuration: 2 Class A (Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A & 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble Amps per AC power on : Green condition on the host control signal circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC amps each, Aux trouble: Yellow 3.0 am addition, the 5495 provides a Form @ P C trouble relay output as an 4.7 kS2 EOL Output alternative to using the notification resistor required troubles (1 -4): Yellow circuit trouble. on each Class B Approvals: circuit UL: 864 & 1481 Electrical Specification . AC input: 120 VAC at 2 amps No. of inputs 2 NFPA: 72 Input CSFM Output: 24 VDC at 6 amps configuration: 2 Class B or 2 Class A Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 fnput Distributed Signal 2 Signal Circuit Output Signal 2 Power Signal 3 Input Module 5495 (Optional) Signal 4 120 VAC Aux. Power I Trouble Output Local Fire Control (Alternative to notification circuit trouble.) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350395 Rev B, 12/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. ® Simplex TrueAlert Multi - Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non- Addressable, SmartSyncTM Operation Compatible Features Visible only (V /O) 24 VDC notification appliances , �mpiex with high output xenon strobe, available for wall or ceiling mount: • UL listed to Standard 1971 "" - �" - • Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing - --=IL—. ,tee • Operation is compatible with ADA requirements (refer FIRE to R E P to important installation information on page 3) • Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Wall Mount Strobes • Regulated circuit design ensures consistent flash output and provides controlled inrush current FIRE . \ FIRE i • Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens \ / Strobes provide synchronized flash for use with: - — — • 4006, 4008, 4010, and 4100U Series fire alarm control Ceiling Mount Strobes panels with NACs selected to provide strobe synchronization or SmartSync two -wire control ** Descri stion • 4009 IDNetTM NAC Extenders Multi Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes. The enclosure designs are both impact and vandal • Separate SmartSync Control Modules (SCMs) that resistant and provide a convenient strobe intensity provide Class B or Class A output from conventional selection. Since each model can be selected for intensity • NAC inputs output, on -site model inventory is minimized and changes encountered during construction can be easily Strobe housings provides flexible, easy, and accommodated. convenient semi -flush or surface wall mounting: Wall mount strobe housings are a one assembly • Rear of housing does not extend into box (including lens) that mounts to a single or double gang, or • Wall mount strobes easily mount to single gang, double 4" square standard electrical box. The cover can be gang, or 4 -inch square outlet box quickly removed (a tool is required) and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model • Wiring terminals are accessible from the front of the number. housing providing easy access for installation, inspection, and testing Strobe Intensity Selection • Covers are available separately to convert housing color During installation, a selection plug at the back of the Optional adapters and wire guards: housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow • Wall mount strobe adapters are available to cover background allows the selected intensity to be seen at the surface mounted electrical boxes and to adapt to side of the strobe lens. Simplex 2975 -9145 boxes • UL listed red wire guards are available for wall or Strobe Application Reference ceiling mount strobes Proper selection of visible notification is dependent on • occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI • This product has been approved by the Cafrfomia State Fire Marshal (CSFM) pursuant to A117.1; the appropriate model building code: BOCA, Section 13144.1 of the California Health and Safety Code. See CSFM Listing ICBO or SBCCI; and the application guidelines of the . 7125- 0026:316 for allowable values and/or conditions concerning material presented in PP g this document. It is subject to re- examination, revision, and possible cancellation. Refer to Americans with Disabilities Act (ADA). page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex "' Simplex multi-candela SmartSync two-wire hom/strobe appliance operation is protected Time Recorder Co. are the property of Tyco Safety Products Westminster. under one or more of the following U.S. Patent Numbers: 5,559,492; 5,622,427; 5,865,527; 5,886,620; 6,281,789; 6,954,137; 7,005,971; and 7,006,003. S4906- 0001 -3 5/2008 • Synchronized Strobes Smart Sync Control Sources Multiple Strobes. When multiple strobes and their Class B Smart Sync two -wire control is available reflections can be seen from one location, synchronized from: flashes reduce the probability of photo- sensitive reactions • 4006, 4008, 4100U, and 4010 Fire Alarm Control as well as the annoyance and possible distraction of Panels (refer to individual product data sheets for more random flashing. These multi - candela strobes are information) synchronized over a two -wire circuit when connected to compatible NACs, to compatible Synchronized Flash • 4009 IDNet NAC Extender (refer to data sheet Modules, or to SmartSync Control Modules. S4009 -0002) • SmartSync Control Module (SCM) 4905 - 9938 (refer to SmartSync Two -Wire Control data sheet S4905 - 0003) Some applications desire the audible notification Class A SmartSync two - wire control is available appliances to be capable of being silenced before the from 4100U NACs and from the 4905 -9938 SCM. alarm condition is reset (on- until - silenced) while the Additional SmartSync compatible notification visible notification appliances are kept activated until the appliances include separate horns and combination alarm condition is reset (on- until- reset). SmartSync horn/strobe notification appliances. operation mode provides this function using a single circuit (two -wire operation). Product Selection Multi - Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color "FIRE" Lettering Description 4906 -9101 Wall Red White 4906 -9103 White Red Multi - candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; 4906-9102 Ceiling Red White SmartSync two -wire control compatible 4906 -9104 g White Red Wall Mount Strobe Adapters Model Description Dimensions 4905 -9937 Red Surface Mount Adapter Skirt; use to cover 1 -1/2" (38 mm) 5 -3/8" H x 5 -1/4" Wx 1 -5/8" D deep surface mounted boxes (136 mm x 133 mm x 41 mm) • 4905-9940 White Total depth with strobe = 4 -3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975 -9145 box (typically for 8 -5/16" x 5 -3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red Mounting Box, requires Adapter Plate 4905 -9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905 9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4 -7/8" x 3 -1/8" x 0.060" D handy box; not needed when using 4905 -9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905 -9914 Class B Synchronized Flash Module; epoxy encapsulated with in /out 18 AWG (0.82 mm wire leads, rated for 2 A NAC, 1 -3/8" x 2-7/16" x 13/16" 4905 -9922 Class A requires 10 mA for power (35 mm x 62 mm x 20 mm) 4905 9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4 -1/8" x 1 -1/4" D 4" (102 mm) square box (102mmx105mmx32mm) Replacement Covers and Guards Model Description Dimensions 4905 -9992 Red cover with white "FIRE" lettering 5 -1/8" H x 5" W x 1 -1/2" D For Wall mount strobes 130 mm x 127 mm x 38 mm 4905 -9993 White cover with red "FIRE" lettering ( ) 4905-9961* Wall mount 6- 1/16" H x 6- 1/16" W x 3 -1/8" D Red wire guard with mounting plate, compatible with (154 mm x 154 mm x 79 mm) semi -flush or surface mounted boxes 6 -1/8" x 4 -3/8" x 2 -7/8" deep 4905 -9926* Ceiling mount (156mmx111 mmx73mm) * UL listed by Space Age Electronics Inc. 2 S4906- 0001 -3 5/2008 Strobe S • ecifications ' Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526 -M878 Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93 %, non - condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm two wires per terminal for in /out wiring Housing Dimensions (with lens) 5 -1/8" H x 5" W x 2 -3/4" D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Strobe Setting (see Note 2 below) 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents 18 VDC 53 mA 84 mA 165 mA 224 mA at other voltages 24 VDC 40 mA 63 mA 124 mA 168 mA Housing Dimensions (with lens) 4 -3/4" L x 2- 5/16" W x 2 -5/8" D (121 mm x 75 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting (see Note 2 below) 75 mA 125 mA 233 mA 316 mA Mount Reference RMS Currents 18 VDC 67 mA 111 mA 207 mA 281 mA at other voltages 24 VDC 50 mA 83 mA 155 mA 211 mA NOTES: 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi -Flush Wall Mounting 07 Mounting is compatible with ( 0 o ( \ I d single gang, double gang, and 1 1 4" (102 mm) square boxes, 1 -1/2" (38 mm) deep, by others A X01 _ , _ . IMPORTANT. WALL MOUNT iI?III1 INSTALLATION HEIGHT REFERENCE r Bottom of lens ,,�� O is either even OP `� w ith, or slightly Electrical Wiring access hole te %Or" i •� � i p!P a bove bottm box outlie l/ � � of compatible �� boxes 6 11 ° , Wir ing terminals 611 " �- O� 1 r � ��p�� g Holes: Mounting i 4" square (4) NFPA 72 requires 80" (2.03 m) ° 00p° °� ® I Single gang (2) t hat the entire lens minimum railW I Double gang (3 be not less than 80" and not greater l than 9 6" above the Transparent housing finished floor and lens assembly Intensity selection il plug, accessible only . from rear of housing; F U N S factory setting is 15 cd iM Removable cover Strobe intensity (tool required) viewing slot 3 S4906- 0001 -3 5/2008 • Ceiling Mount Strobe Installation Reference Handy box, 1 -1/2" (38 mm) deep Single gang box (Wiremold (RACO 650 or equal) or single gang V5744S) 2 -1/4" (57 mm) box, 2 -1/2" (64 mm) deep (RACO 519 deep, supplied by others or equal) supplied by others Also can be attached to boxes /, /./ mounted to drop ceiling T -bar with clips (ERICO No. 512 or equal) 0 0 0 4905 -9910 Adapter Plate, required for surface mount with handy box unless v o using the 4905 -9926 wire guard I I - 1 Ceiling mount strobe 111 II�II �I= III ii 11 Optional mounting 4905-9926 wi guard I I _ with mou plate ., IT / Strobe intensity 1 \ 4 i�� v iewing slot V � � Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference 2975 - 9145 Box with Optional Adapter Skirt and Optional Wire Guard --n Surface mount conduit and O IMII box shown for reference -� 4" (102 mm) square WW INII�I� la �1ITi I �••- p - - box rofile, 1 -1/2" III' I��HIrl■I�IrI1lI ' II (38 mm) deep -- _ I� 11� __ I-_ ( 0 O Optional III 4 905 -9961 IrcLwil . I Wire Guard . 1 4 FORE Strobe I(� � I 4905 -9931 Adapter Plate 1 I , == i_h', 1 _ Optional Surface Mount Adapter Skirt, 0 4905 -9961 Optional Wire Guard 1 -1/2" deep: 4905 -9937, Red; (shown here for reference only, 4905 -9940, White (conduit knockouts 4905 - 9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco is a registered trademark of Tyco International Services GMRH and is used under license. Simplex, the Simplex logo, IDNet, TrueAlert, and SmartSync are trademarks of Tyco International Ltd. and its affiliates and are used under license. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). g Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S4906- 0001 -3 5/2008 ® www.tycosafetyproducts-usa-wm.com C 2008 Tyco Safely Products Westminster. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]