Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (188)
MiTek MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL15-355_UPPER Fax 916/676-1909 POLYGON The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision based on the parameters provided by Pacific Lumber&Truss Co.. Pages or sheets covered by this seal: R45755189 thru R45755200 My license renewal date for the state of Oregon is June 30,2017. Lumber design values are in accordance with ANSUTPI 1 section 6.3 These truss designs rely on lumber values established by others. 'LF-'S\ P R 5FFd' � GG{NEF �- <44 87022PE c— o) tc‘Aj, OREGON rP <v 9O 4SER \,' �O OS A. H0-Av.Pr EX' ' 06/30/ t�, October 27,2015 Hernandez,Marcos The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSUTPI 1. Job Truss Truss Type Qty Ply POLYGON R45755189 PL15-355_UPPER F01 FLOOR 1 1 Job Reference(optional) - -.-Pacific-Lumber&Truss Co,- Beaverton,Oregon --- - - -- 7.530 s Jul 11 2014 MiTek Industries Inc..Tue.Oct27 13:51:20 2015 Page 1 ID:s3crybS_6sJgMSM2Sm_Dy9giZ-Z8J 1 rY?d5vD VTbKMJBy122_DyC9jGwiZPT4JdoyPA2r p-10-01 1� 2-0� 1-01____-_1z 1 2-6-0 1 2-4-9 1 1 1-2-0 1 1 1-9-11 1 Scale=1:40.1 1.5x3 II 1.5x3 I I 1.5x3 II 1.5x3 II 3x6 FP= 3x6= 3x6= 1.5x3 I I 1 2 3 4 5 6 7 8 9 W 11 12 13 14 N. - s .� 000000.00.0."-...................... 11 ii 1.-'1' N ° 4e .. ►�� o .1 24 23 22 21 20 19 18 17 16 15 1.5x3 I I 1.5x3 II 3x8= 3x6 FP= 3x8= 3x8= 3x5= 1 9-10-5 I 3-6-12 I 8-8-5 P 3-51 I 19-6-8 I 22-114 I 3-6-12 5-1-9 7-0 9-8-3 3-5-0 0-7-0 Plate Offsets(X,Y)- 12:0-1-8,Edge1,13:0-1-8,Edciel.118:0-1-8,Edael.f19:0-1-8,Edgel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.43 Vert(LL) -0.13 17-18 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.35 Vert(TL) -0.21 17-18 >893 360 BCLL 0.0 Rep Stress Ina YES WB 0.68 Horz(TL) 0.02 16 n/a n/a BCDL 5.0 Code IBC2012/rP12007 (Matrix) Weight:105 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 15=377/Mechanical,21=950/0-7-0,24=15/0-1-12,16=1450/0-5-8 Max Upliift15=480(LC 6),24-121(LC 6) Max Gray 21=952(LC 3),24=102(LC 5),16=1455(LC 11) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 3-4=0/553,4-0=0/559,5-6=1478/0,6-7=-1478/0,7-8-1478/0,8-9=1051/0, 9-10=-1051/0,10-11=-1051/0,11-12=0/1668,12-13=0/1662 BOT CHORD 20-21=0/743,19-20=0/743,18-19=0/1478,17-18=0/1531,15-16=1235/0 WEBS 2-24=-57/332,3-21=-501/0,5-21=-1356/0,5-19=0/814,11-16=-1740/0,11-17=0/1178, 8-17=525/0,13-15=0/1333,13-16=-812/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 3x4 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)24. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. Cv0 PR QFFs ��c:3. s: & NECD AR si(.1 87022PE N �,CI ySAT OREG•N el,,,4,,,,t/ 9O FM BER 1,� . On A. HER�P EXPIRES:06/30/2017 October 27,2015 t I ®WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.1011312015 BEFORE USE. N. Design valid for use only with Murck®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the bu8ding designer must verity the applicability of design parameters and property incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mllek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the Greenback Lane fabrication,storage,delivery.erection and bracing of trusses and truss systems,see ANSI/TPI1 quality Criteria,DSB-89 and BCSI Building Component 7777109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights.CA 95610 Job Truss Truss Type Qty PlyPOLYGON R45755190 PL15-355_UPPER F02 FLOOR 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon .. 7.530 s Jul 11 2014 MEek Industries,Inc.Tue OcL27 13:5122 2015 Page 1 1 ID:s3crybS_6sJgMSM2Sm_Dy9giZ-WVRnGDOtdWrDiuUkRc?V7T3WV?I5ksHrt iZQigyPA2p 1i -0-0 0. 0 1�A7:� Scale=1:40.5 4x4= 2x4 II 4x4= 3x4= 3x4 = 3x4= 3x4= 3x4= 3x4= 3x6 FP= 4x4 = 3x4= 4x4= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 21 22 23 24 25 of .\ o � NYYY 'i".\s 4' =; �• . cie' C. 32 31 30 29 28 27 26 3x4= 4x6 = 3x6= 3x6 FP= 3x5= 3x5= 3x5= 3x5= 4x4= 4x4= 3x6= 4x6 = 3x4= 1.5x4 SP= 3x5= WARNING:THIS DESIGN MAY EXHIBIT OBJECTIONABLE BOUNCE AND /OR VIBRATION DUE TO THE LENGTH TO DEPTH RATIO OF THE ROOM. PROJECT ENGINEER OR BUILDING DESIGNER TO CONSIDER PROVIDING MEANS DAMPEN THESE EFFECTS VERIFICATION OF LENGTH/DEPTH SLENDERNESS RATIO BY THE PROJECT ENGINEER OR A QUALIFIED BUILDING DES1 -- I$3,JER IS REQUIRED. I 16-5-2 1 -0-21 I 23-9-0 16-5-2 0-7-0 6-1-14 0-7-0 Plate Offsets(X,Y)- 118:0-1-8,Edael,129:0-1-8,Edge1,130:0-1-8,Edgel LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.55 Vert(LL) -0.50 32-33 >567 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.68 Vert(TL) -0.78 32-33 >362 360 BCLL 0.0 Rep Stress Incr YES WB 0.54 Horz(TL) 0.10 26 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:120 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400E 2.0E(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) _ BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 26=866/0-4-4,39=866/Mechanical FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1608/0,3-4=1608/0,4-5=-2891/0,5-6=2891/0,6-7=-3859/0,7-8=3859/0, 8-9=-4510/0,9-10=4510/0,10-11=-4847/0,11-12=-4847/0,12-13=4859/0, 13-14=4859/0,14-15=4583/0,15-16=-4583/0,16-17=4583/0,17-18=3948/0, 18-19=3948/0,19-20=3948/0,20-21=2879/0,21-22=2879/0,22-23=1613/0, 23-24=-1613/0 BOT CHORD 38-39=0/845,37-38=0/2287,36-37=0/3413,35-36=0/3413,34-35=0/4222,33-34=0/4716, 32-33=0/4891,31-32=0/4760,30-31=0/4239,29-30=0/3948,28-29=0/3427,27-28=0/2278, 26-27=0/847 WEBS 18-30=0/696,19-29=-578/0,2-39=1183/0,2-38=0/1068,4-38=952/0,4-37=0/846, 6-37=-730/0,6-35=0/625,8-35=-508/0,8-34=0/403,10-34=288/0,14-31=-305/21, 17-31=0/551,17-30=991/0,2426=1187/0,24-27=0/1072,22-27=-931/0,22-28=0/841, 20-28=768/0,20-29=0/989 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. t.D P R OFF 3)Refer to girder(s)for truss to truss connections. Q' �� 4)Required 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacics to be �Co , G(N,EF- /O attached to walls at their outer ends or restrained by other means. �C? 2 � $7022PE 9r' Ni y �'OT ORE:GO ti) AH �or, ��BER 'V\ .. �`SA. HE ` EXPIRES:06/30/2017 October 27,2015 a r ®WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MIF7473 rev.10/01/2015 BEFORE USE. i• Design valid for use only with M7eh&connectors.This design is based only upon parameters shown.and is for an individual building component,not a truss system.Before use,the budding designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/fP11 Qualty Criteria,051-89 and BCSI Bonding Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street.Suite 312,Alexandria,VA 22314. Citrus Heiatrts,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755191 PL15-355 UPPER F03 floor 5 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon .__ _..._ - - -- -7.530 s Jul 11 2014WeltIndustries,Inc.Tue Oct 27 13:51:24 2015 Page 1 - - - ID:s3crybS_65JgMSM2Sm_D_y9giZ-RvZYhv2798jxyCd7Y01zCu8t3pPZCmR8K52XmZyPA2n 1-0-0 I 1 0-10-2 11 1-2-0 1 f 77 Scale=1:32.4 4x4= 3x4= 3x4= 3x4= 3x4= 3x4= 4x4= 3x4= 4x4= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 e • e/ \ e � �e� �e� �a� �Q/ /,\ / \ /,fie �aXe 29 28 27 26 25 24 23 22 21 '2II 3x4= 4x5= 3x5= 3x5= 3x5= 3x5= 4x4= 3x5= 4x5 = 3x4= 12-10-10 I 11-6-10 11?-3-101 1 19-0-6 1 11-8-10 0-7-0 0-7-0 6-1-14 Plate Offsets(X,YI- 112:0-1-8,Edoel,123:0-1-8,Ednel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.48 Vert(LL) -0.28 25 >806 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.81 Vert(TL) -0.44 25-26 >515 360 BCLL 0.0 Rep Stress Incr YES WB 0.50 Horz(TL) 0.07 20 n/a n/a BCDL 5.0 Code 1BC2012/TP12007 (Matrix) Weight:96 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 30=832/0-3-12,20=832/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1508/0,3-4=-1508/0,4-5=-2627/0,5-6=-2627/0,6-7=3368/0,7-8=3368/0, 8-9=-3726/0,9-10=3726/0,10-11=3737/0,11-12=3737/0,12-13=3422/0, 13-14=3422/0,14-15=2618/0,15-16=2618/0,16-17=1511/0,17-18=1511/0 BOT CHORD 29-30=0/803,28-29=0/2112,27-28=0/3042,26-27=0/3591,25-26=0/3763,24-25=0/3422, 23-24=0/3422,22-23=0/3052,21-22=0/2106,20-21=0/805 WEBS 13-23=429/0,2-30=1125/0,2-29=0/987,4-29=-847/0,4-28=0/720,6-28=582/0, 6-27=0/456,8-27=313/0,12-25=-60/615,18-20=-1127/0,18-21=0/989,16-21=832/0, 16-22=0/717,14-22=609/0,14-23=0/764 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 'S(�Eo PROFFss -..N44"Co NGjN�FR /O�y 87022PE r- // ytP ' r H "0)., OREGON e•P1t/ �O ��SER 1\ �O -.`s A. HEa�P EXPIRES:06/30/2017 October 27,2015 AWARN/NG-Vertry design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with Mirekr connectors.This design is based only upon parameters shown,and is for an individual building.component,not a truss system.Before use,the budding designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPII Quality Criteria,056-89 and BCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Sheet,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755192 PL15-355_UPPER F04 FLOOR 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon - -- - -- - - - -- 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct27 1331:24 2015 Page 1 -- - I D:s3crybS_6sJgM SM2Sm_Dy9giZ-RvZYhv2798jxyCd7Y01 zCu8xepXLCod8K52XmZyPA2n 0-10-0 I I 1-2-0 I 0-0_1-0 9-3-131 2-6-0 I 1 1-2-0 I I 1-37 I Scale=1:19.8 1.5x3 II 3x4 = 3x4 114x4= 1.5x3 II 3x4= 1.5x3 II 1 2 3 3x4= 4 5 6 7 8 3x4= 9 s • • e • o e • e or eNo 0 rtt , N \ 7 - • O e b O • e" 6 17 16 15 —/ 13 12 11 10 1.5x3 II 1.5x3 II 3x6 = 1.5x3 II 1.5x3 II 3x4= 4x6= 3x4 = 3-0-0 I 8-8-59-3-5 9-10-5 11-4-12 30.0 5-8-5 I 0-7.0 I 0-7-0 I 1-6-7 Plate Offsets(X,Y)— f2:0-1-8,Edoel,f3:0-1-8,Edgel,f7:0-1-8,Edge1,f8:0-1-8,Edael LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Udefl L/d PLATES GRIP TCLL 40.0 Plates increase 1.00 TC 0.25 Vert(LL) -0.05 12-13 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.31 Vert(TL) -0.08 12-13 >999 360 BCLL 0.0 Rep Stress Ina YES WB 0.36 Horz(TL) 0.00 10 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:56 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 14=634/0.3-8,17=27/Mechanical,10=331/Mechanical Max Uplift 17=-72(LC 4) Max Gray 14=634(LC 8),17=106(LC 3),10=332(LC 7) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 3-4=0/311,4-5=0/312,5-6=570/0,6-7=570/0,7-8=491/0 BOT CHORD 12-13=0/491,11-12=0/491,10-11=0/491 WEBS 3-14=409/0,5-13=0/713,5-14=508/0,8-10=-610/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. ��_E0 P R OFF.s ��5 . ... F9 /�2 87022PE yr r cv u> ��� OREGIN r ?/V OS E��P A. H EXPIRES:06,/30/'2017 October 27,2015 1 1..WARNING-Verify design parameters andREAD NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE Ml1-7477 rev.10/01/2015 BEFORE USE. Design valid for use only with Mitek*connectors.This design is based onlfyv upon parameters shown,and is for an individual buldingcomponent-not 1111 a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall T building design.Bracing indicated k to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TP11 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Inform:lion available from Truss Plate Institute,218 N.Lee Sheet,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755193 PL15-355 UPPER F06 FLOOR 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon _ _ - - - -- -- -. - "7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 27 13:51:25 2015 Page 1 • - ID:s3crybS6sJgMSM2Sm_D_r9giZ-v57wuF3mwRroZMCJ6kYC15h5hDgrxAglZlo4J?yPA2m 1 0.10.0 ii 1-2-0 ii 1-0-12 1 1 2-3-1 I I 2-6-0 I I 1-2-0 I I 2-3-3 I Scale=1:29.7 3x4= 354= 354= 3x4= 3x4= 1 2 3 43 = 5 6 7 8 9 10 e ee e e o _ e I/ o -e - cit o e e e e e o k. 1�' 18 17 r8 15 14 13 12 11 3x4= 3x6= 3x8= 3x6= 3x4= 3-6-12 I 8-8-5 19-3-5?-10-5I 17-6-0 I 3-6-12 5-1-9 0-7-0 0-7-0 7-7-11 Plate Offsets(X,YI— 12:0-1-8,Edael.F3:0-1-8,Edael.F4:0-3-0,Edael.16:0-1-8,Edgel.17:0-1-8,Edael LOADING(psf) SPACING- 1-7-3 CSL DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.30 Vert(LL) -0.11 12-13 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.48 Vert(TL) -0.17 12-13 >960 360 BCLL 0.0 Rep Stress Ina YES WB 0.69 Horz(TL) 0.02 11 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:81 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 16=958/0-7-0,19=-1/0-1-12,11=571/Mechanical Max Uplift19=105(LC 4) Max Gray 16=958(LC 1),19=103(LC 3),11=574(LC 7) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 34=0/499,4-5=-805/0,5-6=-805/0,6-7=1681/0,7-8=1777/0,8-9=-1777/0 BOT CHORD 15-16=499/0,14-15=0/1681,13-14=0/1681,12-13=0/1681,11-12=0/1165 WEBS 4-16=668/0,2-19=61/296,3-16=-465/0,6-15=959/0,4-15=0/1367,9-11=-1257/0, 9-12=0/661,7-12=-177/271 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)19. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. '<��c) P R QFe, �c`� t, NEER � � 9 87022PE 1' tocv N y �q1, OREG•N q OU z 'AO FM8ER 1,� �S A. HE# EXPIRES:06/30/2017 October 27,2015 111 eN A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design.Bracing indicated is toprevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mile k<. is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage.delivery,erection and bracing of trusses and truss systems,see ANSI/TPII Quality CrHeria,001-89 and SCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755194 PL15-355 UPPER F07 Floor 9 1 Job Reference(optional) PacificLumber&Truss Co., -Beaverton,Oregon - '-'- .- --- - -,----. •- 7.530 s Jul 11 2014.MiTek Industries,Inc.Tue Oct 27 13:51:27 2015 Page 1 °-- - - -- - - ID:s3crybS_6SJgMSM2Sm_Dy9giZ-sUEgJx40S35WpgMiE9bggWmPvORaP7Ka03HBNuyPA2k 1 1-0-0 I SI1 1-2-0 10-7-141 Scale-3/8"=1' 4x4= 3x4= 3x4= 3x4= 3x4= 3x4= 3x4= 3x4= 4x4= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 a • _ o a - e e_/• Ar o _ _ _ 5 \ / � X � � � � a/� � � a • / N p- ee e 30 29 28 27 26 25 24 23 22 21 3x4= 4x5= 3x5= 3x5 = 3x5= 3x5= 3x4= 3x5= 4x5= 3x4 = 12-6-14 I 11-4-14 11-11-11 I 188-12 I 11-4-14 0-7-0 0-7-0 6-1-14 Plate Offsets(X,Y)- 112:0-1-8,Edgel.123:0-1-8,Edgel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Udell Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.44 Vert(LL) -0.26 25-26 >848 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.79 Vert(TL) -0.41 25-26 >542 360 BCLL 0.0 Rep Stress Ina YES WB 0.49 Horz(TL) 0.07 20 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:95 lb FT=0%F,0 kE LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 30=818/Mechanical,20=818/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=1480/0,3-4=1480/0,4-5=-2571/0,5-6=2571/0,6-7=3284/0,7-8=3284/0, 8-9=3615/0,9-10=3615/0,10-11=3587/0,11-12=3587/0,12-13=3327/0, 13-14=3327/0,14-15=2563/0,15-16=2563/0,16-17=1483/0,17-18=1483/0 BOT CHORD 29-30=0/789,28-29=0/2070,27-28=0/2972,26-27=0/3494,25-26=0/3638,24-25=0/3327, 23-24=0/3327,22-23=0/2981,21-22=0/2064,20-21=0/791 WEBS 12-24=-282/0,13-23=-406/0,2-30=1105/0,2-29=0/967,4-29=-827/0,4-28=0/701, 6-28=-562/0,6-27=0/437,8-27=294/0,11-25=265/0,12-25=-58/649,18-20=1107/0, 18-21=0/970,16-21=-814/0,16-22=0/698,14-22=-586/0,14-23=0/723 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ' '' PROFESS �c�� <cNG)N�FR /oy 87022PE r` f �Al, OREGON r)( O<U� 0 SMBER A\• EXPIRES:06/30/2017 October 27,2015 k i ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. l, Design valid for use only with M7ek®connectors.This design is based only upon parameters shown.and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate the design into the overall 1�{ building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage.delivery,erection and bracing of trusses and truss systems,see ANSI/911i Quality Criteria,DSB-89 and SCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755195 PL15-355_UPPER F08 FLOOR 7 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon - ._. - - , • -'- :-- -- -- ' -.--- 7.530-s Jul 112014 MiTek Industries,Inc..Tue Oct 27 13:51:27 2015.Page 1 - : - - `-.- IDrs3crybS6sJgMSM2Sm_Dy9giZ-SUEgJx40535WpgMiE9bggWmPw0XiP3ma03HBNuyPA2k I 2-3-0 I 2-3-0 1 D-5'9 11-2-0 11 1-9-11 1 2-6-0 I 10-8-0 I Scale=1:34.2 1.5x3 II 1.5x3 I I 3x4= 3x4= 1.5x3 I I 3x4 = 1.5x3 I I 3x6= 3x4 II 3x8= 1.5x3 II 1 2 3 4 5 6 7 8 9 10 11 N e/I a _e- \ , • -441444444"44 N 18 17 16 15 14 13 12 3x4 = 1.5x3 II 3x4= 3x8= 3x8= 3x5= 3x5= I 16-2-4 I 19-7-4 I 16-2-4 3-5-0 Plate Offsets(X,Y)— 14:0-1-8,Edge1,115:0-1-8,Edael LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.44 Vert(LL) -0.13 14-15 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.40 Vert(TL) -0.21 14-15 >922 360 BCLL 0.0 Rep Stress Incr YES WB 0.72 Horz(TL) 0.02 13 n/a n/a BCDL 5.0 Code 1BC2012/TP12007 (Matrix) Weight:90 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. `, es. - .2x4 DF Stud/Std(flai) -. BOT CHORD Rigid ceiling directly applied or-3.0-0 oc gracing. - - REACTIONS. (lb/size) 18=588/0-6-0,12=412/Mechanical,13=1537/0-5-8 Max Uplift 12=512(LC 3) Max Gray 18=589(LC 3),13=1537(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=1736/0,3-4=-1736/0,4-55=1867/0,5-6=1867/0,6-7=-1190/0,7-8=1190/0, 8-9=0/1771,9-10=0/1764 BOT CHORD 17-18=0/1110,16-17=0/1867,15-16=0/1867,14-15=0/1795,12-13=1313/0 WEBS 2-18=-1218/0,2-17=0/687,8-13=-1867/0,8-14=0/1308,6-14=-657/0,6-15=84/294, 10-12=0/1418,10-13=851/0,4-17=-462/88 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. <\ .p P R OFFS 4� �NGINEF'Y s/o2y 870 2PE / 1' N 2'y �Aj, OREGON 45."4/ ,AOS F,Lj8ER 1\ OSA Ica# EXPIRES:06/30/2017 October 27,2015 ®WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 my.10103/201S BEFORE USE. MI Design valid for use only with Mtlek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design.Bracing indicated B to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing -.. MiTek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and r,vss systems,see ANSI/TPIf Qualify Crtieda,DSS-89 and SCSI Building Component Suite lire Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite Heights.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755196 PL15-355_UPPER F09 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon- - --- - . - 7.530 s Jul 11 2014 Wok Industries,Inc.Tue Oct 27 13:51:29 2015 Page 1 - IDa3crybS_6sJgMSM2Sm Dy9giZotMRkd6G.ALE2zW4Lad8vxskzg6gtljtUNmlSmyPA2i 1 1-0-0 1 9 l S2_1 1-2-0 1 p-7-141 Scale:3/8"=1' 484= 3x4= 3x4= 3x4= 3x4= 3x4= 4x4= 3x4= 4x4= 1 2 3 4 5 6 7 8 5 10 11 12 13 14 15 16 17 18 19 armiwwwwwir 1 IrL O O O y \ I \ N r e- a a ze kl 29 28 27 26 25 24 23 22 21 304 = 4x5 = 3x5 = 3x5= 3x5= 3x5= 3x4= 3x5 = 4x5= 3x4= 12-9-10 I 11-7-10 tp-2-101 1 18-11-8 11-7-10 10-7-0 0-7-0 6-1-14 1 Plate Offsets(X,Y)- 112:0-1-8,Edgel,123:0-1-8,Edael LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.47 Vert(LL) -0.28 25-26 >817 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.80 Vert(TL) -0.43 25-26 >522 360 BCLL 0.0 Rep Stress Incr YES WB 0.50 Horz(TL) 0.07 20 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight 96 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. . REACTIONS. (lb/size) 30=828/0-2-12,20=828/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=1500/0,3-4=1500/0,4-5=2612/0,5-6=-2612/0,6-7=-3346/0,7-8=-3346/0, 8-9=-3697/0,9-10=3697/0,10-11=3697/0,11-12=3697/0,12-13=3396/0, 13-14=3396/0,14-15=2603/0,15-16=-2603/0,16-17=1504/0,17-18=1504/0 BOT CHORD 29-30=0/800,28-29=0/2101,27-28=0/3024,26-27=0/3565,25-26=0/3730,24-25=0/3396, 23-24=0/3396,22-23=0/3033,21-22=0/2095,20-21=0/801 WEBS 13-23=-423/0,2-30=-1120/0,2-29=0/981,4-29=-841/0,4-28=0/715,6-28=-577/0, 6-27=0/451,8-27=-308/0,12-25=-59/618,18-20=1122/0,18-21=0/984,16-21=827/0, 16-22=0/712,14-22=-602/0,14-23=0/753 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)30. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �� 5 �NF'V 7O Ct- 2 870GINE22PE �� y in - "02, OREG•N c cv �N 9�, FUSER \1 r OS A, HE?' EXPIRES:06/30/2017 October 27,2015 6 4 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE, MIT. Design valid for use only with M7ek0 connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verily the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Crleria,DSI-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755197 PL15-355_UPPER F10 FLOOR 2 1 Job Reference(optional) Pacfic Lumber&Truss Co:, -. Beaverton,Omgen - ' x - - ' ' 7.530 s Jul 11 2014 MiTek Industries,Inc:-Tun Oct 27 13:51:292015.Page 1 -. - -- ID:s3crybS6sJgMSM2Sm_Dy9giZotMRkd6GyLE2zW4Lad8rsrWglbt8otLiNmlSmyPA2I" - 3x4= I 0-11-11 I I 1-2-0 I I 0-10-1 I 1 1.5x3 II 2 3 3x4 = 4 1.5x3 II Scale=1:8.7 0 N / • • • 1.5x3 I I 1.5x3 II g 7 6 3x4= 3x4 = I 3-5-12 I 3-5-12 Plate Offsets(X,Y)•- 12:0-1-8,Edge1,13:0-1-8,Edge1 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) -0.00 7 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.05 Vert(TL) -0.00 7 >999 360 BCLL 0.0 Rep Stress Ina YES WB 0.05 Horz(TL) 0.00 5 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:18 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.18.Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-5-12 oc purlins, except BOT CHORD 2x4 DF No.18Btr(flat) end verticals. __ WEBS 1ii4 OF StuzliStd(llai) BOT CHORD - eta i cJ'llin0 directly applied or 104J-0 oc braung. REACTIONS. (lb/size) 8=184/0-2-12,5=184/0-2-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8,5. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. <<,,s,Ea P R or. 00 ,y ��GINE -R io29 cr 4C-- 87022PE c-- // Z'y(g‘ SAT OREGON (1,QIN 90 AMBER \1 ," ®s A. HE cAr EXPIRES:06/30/2017 October 27,2015 WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MN-7473 rev.10/03/2015 BEFORE USE. Mil Design valid for use only with MTekm connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use.the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary arid permanent bracing Mitek' isalways required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/SPII Quality Criteria,DSI-89 and SCSI Building Component Suite 109 Safety Information available from Truss Plate institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755198 PL15-355_UPPER F11 FLOOR GIRDER 1 1 Job Reference(optional) ... Pacific Lumber&Truss Co., - Beaverton,Oregon ..7.530 s Jul 11 2014 MiTek Industries,Inc.-Tue OU 2773:51'3620.15-Page 1-. - ID:s3crybS_6sJgMSM2Sm_Dy9giZ-G3wpxz6ul_U:g75HvH8NR9OtAERBcoe1i1 Wr CyPA2h 0-.F. -0 11 1-2-0 II 1-0-12 I I 1-0-0 I 0-1_7-91I 1-2-0 II 0-11-3 I Scale=1:33.3 3x4= 3x4= 3x4 II 4x4= 3x4= 3x4= 3x4= 3x4= 3x4= 3x4 = 5x6 = 1 2 3 4 5 6 7 8 9 10 1112 13 14 15 16 17 18 19 a e a A' e e e a - lip o e - e e e e e Irc4 94 � ii 3 3130 29 28 27 26 25 24 23 22 21 3x4 = 3x6= 4x5= 3x5= 3x6= 3x5= 3x5= 4x8= 3x4 = 1 1-1-0 11 8 012-}-0 I 3 6 12 I 8-8-5 993-5 -10.51 19-6-8 1-1-0 0.7-0 0.7-0 1-3-12 5-1-9 C4-:5%0.7-0 9-8-3 Plate Offsets(X,Y)- 12:o-1-8,Eddel.13:0-1-8,Edge1,19:0-1-B,Edoel.110:0.1-8,Edgel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.63 Vert(LL) -0.18 24-25 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.86 Vert(TL) -0.29 24-25 >668 360 BCLL 0.0 Rep Stress Ina NO WB 0.84 Horz(TL) 0.04 20 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:99 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applies?cr -0-0 oc bracing. ..4., t REACTIONS. (lb/size) 29=1347/0-7-0,32=164/0-1-12,20=1315/0-2-12 Max Uplift 32=-269(LC 4) Max Gray 29=1347(LC 1),32=60(LC 3),20=1318(LC 7) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=0/450,3-4=0/1096,4-5=0/1096,5-6=-610/0,6-7=610/0,7-8=1756/0, 8-9=-1756/0,9-10=2370/0,10-11=-2900/0,11-12=2900/0,12-13=-3113/0, 13-14=3113/0,14-15=2995/0,15-16=2995/0,16-17=2480/0,17-18=2480/0 BOT CHORD 31-32=-450/0,30-31=_450/0,29-30=-450/0,27-28=0/1248,26-27=0/2370,25-26=0/2370, 24-25=0/2370,23-24=0/3031,22-23=0/3098,21-22=0/2793,20-21=0/1299 WEBS 2-31=252/0,9-26=0/410,10-25=331/0,2-32=0/665,3-29=917/0,5-29=1249/0, 5-28=0/1047,7-28=-898/0,7-27=0/716,8-27=11/251,9-27=-1122/0,18-20=-1819/0, 18-21=0/1654,17-21=839/0,16-21=-438/0,16-22=0/283,11-24=-266/0,10-24=0/844 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1,5x3 MT20 unless otherwise indicated. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)32,20. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to "<(' �© p R Q . be attached to walls at their outer ends or restrained by other means. F 5)CAUTION,Do not erect truss backwards. \co ��GINE - /O 6)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)791 lb down at 17-5-0 on top chord. C? 2 The design/selection of such connection device(s)is the responsibility of others. 870 2 P E �v- 7)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 o (Nr Uniform Loads(p8) (‘ Vert:20-32=-8,1-19=80 7 'ot, OREGON r1o\AC!O Concentrated Loads(Ib) ' Q E R ' ',�+, O 9 ''M Vert:17=791(F) Or) A. H E0.\'' EXPIRES:06/30/2017 October 27,2015 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MIF7473 rev,10/03/2015 BEFORE USE. flit. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and h for an individual building component,not a truss system.Before use,the bulding designer must verify the applicability of design parameters and properlyincorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only•Additional temporary and permanent bracing MOM( is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the . 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,056-89 and SCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. - Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755199 PL15-355_UPPER F12 FLOOR 1 1 Job Reference(optional) _ Pacific Limber&Truss Co,,-- Beavetian,_Oneyon - --- - '_ - - 7.530 s Jul 11 2014 Welt Industries,inc.TLe Oct 27 1181:312035-Pagel - - .:- .. IDa3crybS_6sJgMSM2Sm_Dy9giZ-kFU6917WWHcyIHgTT?fc Mx3VercLvrAxhFPWryPA2g o-l--:r-O 1 1-2-0 11f 0.12H 1 2-6.0 I 2-49 ii 1-2-0 1 I 1-9-7 1 Scale=1:34.0 1.5x3 iI 3x4 = 3x4 = 3x4 II 3x6= 1.5x3 I I 1.5x3 II 3x4= 1.5x3 II 3x5= 1.5x3 I I 1 2 3 4 5 6 7 8 9 10 11 e • i i _ e_ S 19 18 17 16 15 14 13 12 3x4=1.5x3 II 1.5x3 II 3x8= 3x5= 3x4= 3x6= 3x4 =- 1 1 3-6-12 1 8-8-53-58-10-51 19-6-4 I 3-6-12 5-1-9 7-0 0-7-0 9-7-15 Plate Offsets(X,Y)— 12:0-1-8,Edgel.f3:0-1-8.Edge1.114:0-1-8,Edge.[15:0-1-8,Edgel LOADING(psf) SPACING- 1-7-3 CSL DEFL. in (loc) Vdefl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.47 Vert(LL) -0.21 13-14 >913 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.59 Vert(TL) -0.33 13-14 >573 360 BCLL 0.0 Rep Stress Ina YES WB 0.61 Horz(TL) 0.03 12 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:88 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD. Rigid ceiling directly applied or 6-0-0 oc bracing. - REACTIONS. (lb/size) 16=1117/0-7-0,19=60/0-1-12,12=649/0-2-12 Max Uplift 19=166(LC 4) Max Gray 16=1117(LC 1),19=89(LC 3),12=651(LC 7) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=18/294,34=0/714,4-5=0/720,5-6=1980/0,6-7=-1980/0,7-8=1980/0, 8-9=-2148/0,9-10=-2148/0 BOT CHORD 18-19=294/18,17-18=294/18,16-17=294/18,15-16=0/887,14-15=0/1980, 13-14=0/2325,12-13=0/1362 WEBS 6-15=-345/0,2-19=27/435,3-16=-616/0,5-16=1682/0,5-15=0/1201,10-12=-1470/0, 10-13=0/849,8-14=512/54 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)19,12. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. .<°\'‘ Se. P OFFss c.:3. <c., N E�cR (3 _ c.:3. cc s7022PE yN ,�V ti GAJ, OREG N ti�a� O� A- HECk EXPIRES:06/30/2017 October 27,2015 WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. 1. Design valid for use only with MTekS connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate the design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek` - - is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/7811 Qualify Crfteria,DS11-89 and SCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 7 Job Truss Truss Type Qty Ply POLYGON R45755200 PL15-355 UPPER F13 FLOOR 1 1 _ Job Reference(optional) - 'r'aud>Lumber 8"truss cl. .Beaverton,Oregon .__. - ... 7.530 sJat 11 2014 ulirak Illusries,trt,,-Tue.OM 2713:51:322015 Page 1 - - --- - , • IDa3cryb5_6sJgMSM2Sm_:1_ygrJi7.-CR2Y-.it9eail'3GbkovRFhtiArXaUMt1KQ4VhKAL?y25yPA2f 3x4 = I 0-11-11 I I 1-2-0 I I 0-9-5 I 1 1.5x3 II 2 3 3x4 = 4 1.5x3 II Scale=1:8.7 —II 4%1 MBE 0 . N a, 41 EM 111 111 ME ■ ■ 11111/:!. / 1.5x3 II 1.5x3 II 8 // 7 6 5 3x4= 3x4= 3S-0 I I 3-5-0 Plate Offsets(X,Y)— (2:0-1-8,Edoe1,f3:0-1-8,Eduel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.04 Vert(LL) -0.00 7 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.04 Vert(TL) -0.00 7 >999 360 BCLL 0.0 Rep Stress Ina YES WB 0.04 Horz(TL) 0.00 5 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:18 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-5-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) -- 80T CHORD Rigid ,e ;n directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=145/0-2-12,5=145/Mechanical FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. Gs. <(..... N F9 c 2 8 I 2PE 9 fr 5, C‘N�'oj, OREGO et? ti./ '51.O �MsER 1'� �O ®� A. He?, EXPIRES:06/30/2017 October 27,2015 "616= '&. 41166666M 4111EMi . ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE M&7473 rev.10/03/2013 UEFORE USE. Design valid for use only with MTekS connectors.This design is based only upon parameters shown,and B for an individual bulldogcomponent,not a truss system.Before use,the building designer must verity the applicability of design parameters and properly incorporate this design into the overall - building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Milek" is always required for stability and to prevent collapse with possible personal injury and properly damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPl1 Quaily Criteria,DSB-89 and SCSI Building Component Suite 109 Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus HeiaAts CA 95610 Symbols Numbering System A General PLATE LOCATION AND ORIENTATION 3/" Center plate on joint unless x,y 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property 14 (Drawings not to scale) offsets are indicated. I Damage or Personal Injury M. Dimensions are in ft-in-sixteenths. Ilik Apply plates to both sides of truss 1 2 3 1. Additional stability bracing for truss system,e.g. and fully embed teeth. diagonal orx bracin TOP CHORDS 9 g,is always required. See BCSI. 01 „ 2. Truss bracing must be designed by an engineer.For '/16 4 wide truss spacing,individual lateral braces themselves WEBS may require bracing,or alternative Tor I I pbracing should be considered. �_ U =O 3. Never exceed the design loading shown and never stack materials on inade uate braced trusses. Uq IY�► o a ~ C7-e Cha C5-6 O 4. Provide copies of this truss design to the building For 4 x 2 orientation,locatedesigner,erection supervisor,property owner and plates 0 'nd' from outside BOTTOM CHORDS all other interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully.Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from • CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. `Plate location details available In MiTek 20/20 NUMBERS/LETTERS. software or upon request. 8. Unless otherwise noted,moisture content of lumber shall not exceed 19%at time of fabrication. PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for ICC ES Reports: use with fire retardant,preservative treated,or green lumber. The first dimension is the plate 10.Camber is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311,ESR 1352,ESR1988 responsibility of truss fabricator.General practice is to to slots.Second dimension is ER-3907,ESR-2362,ESR 1397,�SR 3282 camber for dead load deflection. the length parallel to slots. 11.Plate type,size,orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and in all respects,equal to or better than that �f Indicated by symbol shown and/or Trusses are designed for wind loads in the plane of the specified. by text in the bracing section of the truss unless otherwise shown. 13.Top chords must be sheathed or purlins provided at output. Use T or I bracing spacing indicated on design. if indicated. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values 14.Bottom chords require lateral bracing at 10 ft.spacing, or less,if no ceiling is installed,unless otherwise noted. BEARING established by others. 15.Connections not shown are the responsibility of others. Indicates location where bearings 16.Do not cut or alter truss member or plate without prior (supports)occur. Icons vary but ©2012 MiTek®All Rights Reserved approval of an engineer. MON reaction section indicates joint 17.Install and load vertically unless indicated otherwise. ler ® number where bearings occur. Min size shown is for crushing only. �I ►--� 18.Use of green or treated lumber may pose unacceptable environmental,health or performance risks.Consult with Industry Standards: project engineer before use. ANSI/TPI1: National Design Specification for Metal 19.Review all portions of this design(front,back,words Plate Connected Wood Truss Construction. and pictures)before use.Reviewing pictures alone DSB-89: Design Standard for Bracing. Is not sufficient. NI ,, BCSI: Building Component Safety Information, ! 20.Design assumes manufacture in accordance with Guide to Good Practice for Handling, ANSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev.10/03/2015