Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (196)
MiTek° MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL15-354 UPPER Fax 916/676-1909 POLYGON The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision based on the parameters provided by Pacific Lumber&Truss Co.. Pages or sheets covered by this seal: R45755177 thru R45755188 My license renewal date for the state of Oregon is June 30,2017. Lumber design values are in accordance with ANSUTPI 1 section 6.3 These truss designs rely on lumber values established by others. ���co PR°fFss ��� ENGINEER /0 2 87022PE 9r N 7 �Aj, OREGON tiz �N � $'11, ,I8ER \` 4o OS A. HER�� E "�• ./ t c October 27,2015 Hernandez,Marcos The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSI/TPI 1. Job Truss Truss TypeQty Ply POLYGON R45755177 PL15-354_UPPER F01 FLOOR 1 1 • Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 27 13:50:54 2015 Page 1 ID:s3c ybS_6sJgMSM2Sm_D_y9giZ-J81COttWDwxCLbLMojVx ZvmWjHeA9GkRQnxjIyPA3F ¢10I.0, 1I 2-0 1- 11_-0-121 1 2-6-0 I 2-4-9 I I 1-2-0 I I 1-9-11 I P-841 r Scale=1:40.1 1.5x3 II 1.5x3 II 1.5x3 II 1.5x3 II 3x6 FP= 3x6= 3x6= 1.5x3 II 1 2 3 4 5 6 7 8 9 10 11 12 13 14 i a o !e a\ire/ \ e e / `=S/ I�fl/_ a. 1N 24 23 22 21 20 19 18 17 16 15 1.5x3 II 1.5x3 II 3x8= 3x6 FP= 3x8= 3x8= 3x5 9-10-5 I 3-6-12 I 8-8-5 f3-51 I 19-6-8 I 22-11-8 I 3-6-12 5-1-9 7-0 9-8-3 3-5-0 0-7-0 Plate Offsets(XV)— 12:0-1-8,Edue1.13:0-1-8,Edge).118:0-1-8,Edgel.119:0-1-8,Edclel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (roc) L/defl LJd PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.43 Vert(LL) -0.13 17-18 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.35 Vert(TL) -0.21 17-18 >893 360 BCLL 0.0 Rep Stress Incr YES WB 0.68 Horz(TL) 0.02 16 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:105 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 15=377/Mechanical,21=950/0-7-0,24=-15/0-1-12,16=1450/0-5-8 Max Uplift15=480(LC 6),24=-121(LC 6) Max Gray 21=952(LC 3),24=102(LC 5),16=1455(LC 11) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 3-4=0/553,4-5=0/559,5-6=-1478/0,6-7=-1478/0,7-8=-1478/0,8-9=-1051/0, 9-10=-1051/0,10-11=1051/0,11-12=0/1668,12-13=0/1662 BOT CHORD 20-21=0/743,19-20=0/743,18-19=0/1478,17-18=0/1531,15-16=1235/0 WEBS 2-24=57/332,3-21=-501/0,5-21=-1356/0,5-19=0/814,11-16=1740/0,11-17=0/1178, 8-17=-525/0,13-15=0/1333,13-16=-812/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 3x4 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)24. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. <-,$),0 PR R 0Fe, ,..2� �NG(NEFR 3'/O2-�r 87022PE / U) - ti - tCNA,,, OREGO q, Q<v 9O FMBER \1 V. On A. HECk EXPIRES:06/30/2017 October 27,2015 t I AWARN/NG-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev.10/03/2015 BEFORE USE. ' Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/fP11 Quality Criteria,051-89 and SCSI Building Component Safely Inbrma8on available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Cants Heights.CA 95610 1 Job Truss Truss Type Qty Ply POLYGON R45755178 PL15-354_UPPER F02 FLOOR 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 27 13:50:56 2015 Page 1 I Ds3crybS6sJgM SM2 Sm_Dy9giZ-G W typKiZlXBvbvUkv8XP343Xt0e5rOukG2oByPA3D 1 1-0-0 1 0-mo 11 -0 Him Scale=1:40.5 4x4= 2x4 II 4x4= 3x4= 3x4 = 3x4= 3x4= 3x4= 3x4= 3x6 FP= 4x4= 3x4= 4x4=- 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 21A ;<' ?i /A\ 1 / N. / N / N / N / N / N / X / N / \ / \ "e e IN 39 38 37 36 35 34 33 32 31 30 29 28 27 26 3x4= 4x6 = 3x6= 3x6 FP= 3x5= 3x5= 3x5= 3x5= 4x4= 4x4= 3x6= 4x6 = 3x4 = 1.5x4 SP= WARNING:THIS DESIGN MAY EXHIBIT OBJECTIONABLE BOUNCE AND 3x5= /OR VIBRATION DUE TO THE LENGTH TO DEPTH RATIO OF THE ROOM. PROJECT ENGINEER OR BUILDING DESIGNER TO CONSIDER PROVIDING MEANS DAMPEN THESE EFFECTS VERIFICATION OF LENGTH/DEPTH SLENDERNESS RATIO BY THE PROJECT ENGINEER OR A QUALIFIED BUILDING DESIGNER IS REQUIRED. 17-7-2 I 16-5-2 147-0-21 1 23-9-0 1 16-5-2 0.7-0 6-1-14 0-7-0 Plate Offsets(X,Y)- Ii8:0-1-8,Edgel.129:0-1-8,Edael,130:0-1-8,Edgel LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) l/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.55 Vert(LL) -0.50 32-33 >567 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.68 Vert(TL) -0.78 32-33 >362 360 BCLL 0.0 Rep Stress Ina YES WB 0.54 Horz(TL) 0.10 26 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:120 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purling, except BOT CHORD 2x4 DF 2400F 2.0E(flat) end verticals. WEBS 2x4 DF Stud/Std(tlat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 26=866/0-4-4,39=866/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=1608/0,3-4=-1608/0,4-5=2891/0,5-6=2891/0,6-7=-3859/0,7-8=-3859/0, 8-9=4510/0,9-10=-4510/0,10-11=4847/0,11-12=4847/0,12-13=-4859/0, 13-14=4859/0,14-15=-4583/0,15-16=4583/0,16-17=-4583/0,17-18=3948/0, 18-19=-0948/0,19-20=3948/0,20-21=2879/0,21-22=2879/0,22-23=1613/0, 23-24=1613/0 BOT CHORD 38-39=0/845,37-38=0/2287,36-37=0/3413,35-36=0/3413,34-35=0/4222,33-34=0/4716, 32-33=0/4891,31-32=0/4760,30-31=0/4239,29-30=0/3948,28-29=0/3427,27-28=0/2278, 26-27=0/847 WEBS 18-30=0/696,19-29=578/0,2-39=1183/0,2-38=0/1068,4-38=-952/0,4-37=0/846, 6-37=-730/0,6-35=0/625,8-35=-508/0,834=0/403,10-34=288/0,14-31=-305/21, 17-31=0/551,17-30=-991/0,2426=1187/0,24-27=0/1072,22-27=-931/0,22-28=0/841, 20-28=-768/0,20-29=0/989 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. �k a D PR Qp,.. 3)Refer to girder(s)for truss to truss connections. 4)Required 2x6 strongbacics,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be \Gj 0.4&INE .,9 /0 attached to walls at their outer ends or restrained by other means. ,N 29 `-- 870 2PE cp. cv -7 -0),OREGO e OWN o x'18ER \\ �S A. HECk EXPIRES:06/30/2017 October 27,2015 a WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MI57473 rev.10/03/2015 BEFORE USE. In Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the buiding designer must verify the applicability of design parameters and properly incorporate this design into the overall buiding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/flU Qually Criteria,DSI-89 and ICSI BuBding Component 7777 Greenback enback Lane Safety Inlormalon available from Truss Plate Institute.218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755179 PL15-354_UPPER F03 Floor 5 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 27 13:50:57 2015 Page 1 • ID:s3crybS_6sJgMSM2Sm_D_r9giZ-kjQLOgjC WrJmD23xTs2ecBXGtwBFNZIA700cKdyPA3C 1 1-0-0 1 1 0-10-2 11 1-2-0 1 141 Scale=1:32.4 4x4= 3x4= 3x4= 3x4= 3x4= 3x4= 4x4= 3x4= 4x4= 1 2 3 4 5 6 7 8 . 9 10 11 12 13 14 15 16 17 18 19 e e '1'° / \ / \--4/ N di N.- /er N 4 / \i„.. /- \,, /"N . ,. e e e Ve 29 28 27 26 25 24 23 22 21 3�XOj 3x4= 4x5= 3x5= 3x5= 355= 3x5= 4x4= 3x5= 4x5= 3x4= 12-10-10 I 11-8-10 1170-33-100-7-0 I 19 11-8-10 6-1-14 Plate Offsets(XY)- f12:0-1-8,Edae1.f23:0-1-8,Edae1 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.48 Vert(LL) -0.28 25 >806 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.81 Vert(TL) -0.44 25-26 >515 360 BCLL 0.0 Rep Stress Ina YES WB 0.50 Horz(TL) 0.07 20 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:96 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 30=832/0-3-12,20=832/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=1508/0,3-4=1508/0,4-5=2627/0,5-6=-2627/0,6-7=3368/0,7-8=-3368/0, 8-9=-3726/0,9-10=3726/0,10-11=3737/0,11-12=3737/0,12-13=3422/0, 13-14=-3422/0,14-15=2618/0,15-16=2618/0,16-17=1511/0,17-18=1511/0 BOT CHORD 29-30=0/803,28-29=0/2112,27-28=0/3042,26-27=0/3591,25-26=0/3763,24-25=0/3422, 23-24=0/3422,22-23=0/3052,21-22=0/2106,20-21=0/805 WEBS 13-23=-429/0,2-30=1125/0,2-29=0/987,4-29=847/0,4-28=0/720,6-28=-582/0, 6-27=0/456,8-27=313/0,12-25=-00/615,18-20=-1127/0,18-21=0/989,16-21=832/0, 16-22=0/717,14-22=-609/0,14-23=0/764 NOTES- 1)Unbalanced floor rive loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. <'R, PROp ,NI 0NGI N E''9 s/O.1 8 • 2PE / r 7 N�'o,,, OREGO it / 'Aon ,ii. N\ OSA. HE ` EXPIRES:06/30/2017 October 27,2015 1 a WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE " Design valid for use only with M1ek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the budding designer must verify the applicability of design parameters and property incorporate the design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek° is always required for stabTity and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/SP11 Qually Criteria,058-89 and ICS!/uIlding Component Suite 109 Solely information available from Truss Plate Insfitute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Hetahis.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755180 PL15-354_UPPER F04 FLOOR 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Tue Oct 27 13:50:58 2015 Page 1 ID:s3crybS_6sJgMSM2Sm_Dy9giZ-CvjE0kgH8RdgCe71 ZZt8P3VCKfG62BJM219s3yPA3B 1 0-10-0 1 1 1-2-0 II 9-3-131 2-6-0 I 1 1-2-0 I I 1-37 1 Scale=1:19.8 1.5x3 I I 3x4= 3x4 114x4= 1.5x3 II 3x4= 1.5x3 II 1 2 3 3x4= 4 5 6 7 8 3x4= 9 • • • e • -,.. • w • •4N:2,,\—i -----------,.......,...._,........„,......,,,„,.........„a a 41 N ., ., & e 17 16 15 F. 13 12 11 10 1.5x3 II 1.5x3 II 3x6 = 1.5x3 II 1.5x3 II 3x4 = 4x6= 3x4 = I 3-3-0-0-0 I 8-8-5 1 9-3-5 1 9-10-5 1 11-4-12 I 5-8-5 0-7-0 0-7-0 1-6-7 Plate Offsets(X,Y)— (2:0-1-8,Edge1,13:0-1-8,Edgel.f7:0-1-8,Edoe1,18:0-1-8.Edgel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (lac) 1/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.25 Vert(LL) -0.05 12-13 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.31 Vert(TL) -0.08 12-13 >999 360 BCLL 0.0 Rep Stress Ina YES WB 0.36 Horz(TL) 0.00 10 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:56 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.18Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) HOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 14=634/0-3-8,17=27/Mechanical,10=331/Mechanical Max Uplift17-72(LC 4) Max Gray 14=634(LC 8),17=106(LC 3),10=332(LC 7) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 3-4=0/311,4-5=0/312,5-6=570/0,6-7=570/0,7-8=-491/0 BOT CHORD 12-13=0/491,11-12=0/491,10-11=0/491 WEBS 3-14=-409/0,5-13=0/713,5-14=508/0,8-10=-610/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. ''Ea PR°Fess 5 NGINF9 wo 2 8 12PE /9 c - N nRI -7 �Aj, OREGO �o ��/ 'AO �c�8ER �1 �O OS A. HO:‘ .<4 EXPIRES:06/30/2017 October 27,2015 I ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MH-7473 rev.10/03/2015 BEFORE USE Design valid for use only with Mack®connectors.This design is based only upon parameters shown,and is for an individual budding component,not till es a truss system.Before use,the budding designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quail),Criteria,DSI-89 and SCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heiahs.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755181 PL15-354_UPPER FOB FLOOR 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 27 13:50:59 2015 Page 1 I D:s3crybS_6sJgMSM2Sm_D_y9giZ-g5Y5RMkS2SaU SMDJbG46hccfFkymrQETai ViPVyPA3A a�O-0I I 1-2-0 I I 1-0-12 1 1 2-3-1 I I 2-6-0 I I 1-2-0 I I 2-33 I Scale=1:29.7 3x4= 3x4= 3x4= 3x4= 3x4= 1 2 3 4 3x8= 5 6 7 8 9 10 1:74:- . e e e o 02.1611 '` 18 17 ►�A, 1 15 14 13 12 11 3x4= 3x6= 3x8= 3x6= 3x4= I 3-6-12 I 6-8-5 19-3-5?-10-51 17-6-0 I 3-6-12 5-1-9 0-7-0 0-7-0 7-7-11 Plate Offsets(X,Y)- 12:0-1-8.EdaeL 13:0-1-8,Edoel,14:0-3-0,Edael.16:0-1-8,Edael,f7:0-1-8,Edael LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.30 Vert(LL) -0.11 12-13 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.48 Vert(TL) -0.17 12-13 >960 360 BCLL 0.0 Rep Stress Ina' YES WB 0.69 Horz(TL) 0.02 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:81 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.18Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) - BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 16=958/0-7-0,19=1/0-1-12,11=571/Mechanical Max Uplift 19-105(LC 4) Max Gray 16=958(LC 1),19=103(LC 3),11=574(LC 7) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 3-4=0/499,4-5=-805/0,5-6=-805/0,6-7=-1681/0,7-8=-1777/0,8-9=-1777/0 BOT CHORD 15-16=-499/0,14-15=0/1681,13-14=0/1681,12-13=0/1681,11-12=0/1165 WEBS 4-16=-668/0,2-19=-61/296,3-16=-465/0,6-15=959/0,4-15=0/1367,9-11=-1257/0, 9-12=0/661,7-12=-177/271 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)19. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. c2.3.. � 87022PE 9 1 N N� 0 , IV 7Aj, OREG94li0 9O AMBERN\ OSA . HO; EXPIRES:06/30/2017 October 27,2015 1 i A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MN-7473 rev.10/03/2015 BEFORE USE. ~ Design valid for use only with Mitek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the buiding designer must verity the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual tuns web and/or chord members only.Additional temporary and permanent bracing - MiTekr. is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the Greenback Lane fabrication,storage.delivery,erection and bracing of trusses and truss systems,see ANSI/1P11 Quality Criteria,051-89 and SCSI Building Component 7777Suite 109 Solely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Claus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755182 PL15-354_UPPER F07 Floor 9 1 Job Reference(optonal' Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 27 13:51:00 2015 Page 1 ID:s3crybS_6sJq MSM2Sm_D_y9giZ-8H6Tfi14pmiL4 Wo W8_cLEg9oj8DGawecp M EGxyyPA39 110-0 P-6-611 1-2-0 1 p-� Scale:3/8"=1' 4x4= 3x4= 3x4= 3x4= 3x4= 3x4= 3x4= 3x4= 4x4= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 e e o - e e e _ e_ •_ - • / \ / � / N / \. ./ N /I e/� /. \ a / \ N e 30 29 28 27 26 25 24 23 22 21 i 3x4 = 4x5= 3x5= 3x5 = 3x5= 3x5= 3x4 = 3x5= 4x5= 3x4= 12-6-14 I 11-4-14 11-11-11 I 18-8-12 I 11-4-14 0-7-0 0-7-0 6-1-14 Plate Offsets(X,Y)- 112:0-1-8,Edoel,123:0-1-8,Edgel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (lac) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.44 Vert(LL) -0.26 25-26 >848 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.79 Vert(TL) -0.41 25-26 >542 360 BCLL 0.0 Rep Stress Ina YES WB 0.49 Horz(TL) 0.07 20 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:95 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 OF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 30=818/Mechanical,20=818/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-1480/0,3-4=1480/0,4-5=2571/0,5-6=-2571/0,6-7=-3284/0,7-8=-3284/0, 8-9=3615/0,9-10=3615/0,10-11=3587/0,11-12=3587/0,12-13=3327/0, 13-14=-3327/0,14-15=2563/0,15-16=2563/0,16-17=1483/0,17-18=1483/0 BOT CHORD 29-30=0/789,28-29=0/2070,27-28=0/2972,26-27=0/3494,25-26=0/3638,24-25=0/3327, 23-24=0/3327,22-23=0/2981,21-22=0/2064,20-21=0/791 WEBS 12-24=282/0,13-23=-406/0,230=1105/0,2-29=0/967,4-29=-827/0,4-28=0/701, 6-28=-562/0,6-27=0/437,8-27=294/0,11-25=265/0,12-25=58/649,18-20=1107/0, 18-21=0/970,16-21=-814/0,16-22=0/698,14-22=-586/0,14-23=0/723 NOTES, 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �c0 0 P R OAFS :114C-ci 5:80147RGOEI NE�Rs/�"0- 2PE rN SG N ti� �� 90 FM&ER \� .Q OS A. HE �P EXPIRES:06/30/2017 October 27,2015 4 / ®WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. _r Design valid for use only with Mnekm connectors.This design is based orrlyy upon parameters shown:and is for an individual bulding component,not a� a truss system.Before use,the budding designer must verify the applicability of design parameters oral properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TP11 Qualify Criteria.DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755183 PL15-354 UPPER F08 FLOOR 7 1 Job Reference(ootinnall Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 27 13:51:00 2015 Page 1 ID:s3crybS_65JgMSM2Sm_Dy9g1Z-8H6Tfi14pmiLp4W .WoO8_cLEg9ok8JOes4cpMEGxyyPA39 I 2-3-0 I 2-3-0 110A- 1 1-2-0 II 1-9-11 1 2-6-0 I 1— Q 1 Scale=1:34.2 1.5x3 II 1.5x3 II 3x4= 3x4= 1.5x3 II 3x4= 1.5x3 II 3x6= 3x4 II 3x8= 1.5x3 II 1 2 3 4 5 6 7 8 9 10 11 1 N e 00.............. �/I e or we + IN gg 18 17 16 15 14 112 3x4= 1.5x3 II 3x4= 3x8= 3x8= 355= 3x5= I 16-2-4 I 19-7-4 I 16-2-4 3-5-0 Plate Offsets(X,Y)— 14:0-1-8,Edael,115:0-1-8,Edoel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in floc) 1/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.44 Vert(LL) -0.13 14-15 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.40 Vert(TL) -0.21 14-15 >922 360 BCLL 0.0 Rep Stress Inc( YES WB 0.72 Horz(TL) 0.02 13 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:90 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. 1 WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 18=588/0-6-0,12=412/Mechanical,13=1537/0-5-8 Max Upliftl2=-512(LC 3) Max Gray 18=589(LC 3),13=1537(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=1736/0,3-4=1736/0,4-55=1867/0,5-6=1867/0,6-7=1190/0,7-8=1190/0, 8-9=0/1771,9-10=0/1764 BOT CHORD 17-18=0/1110,16-17=0/1867,15-16=0/1867,14-15=0/1795,12-13=-1313/0 WEBS 2-18=-1218/0,2-17=0/687,8-13=-1867/0,8-14=0/1308,6-14=-657/0,6-15=84/294, 10-12=0/1418,10-13=851/0,4-17=462/88 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. 2 �� 87022PE -Yf cv 7 �-OT OREGO rye zo �On cMRER 1\ �O S A. HE.Ck EXPIRES:06/30/2017 October 27,2015 1 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE Mil-7473 rev.10/03/2015 BEFORE USE. ININ _ -- Design valid for use only with Mnekm connectors.This design is based only upon parameters shown.and is for an individual building coponent,not o truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this desimgn into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stabtity and to prevent collapse with posses personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/fP11 QuaBy Criteria,056.89 and 6031 Building Component Suite 109 Safety informaflon available horn Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heiohts.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755184 PL15-354_UPPER F09 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Tue Oct 27 13:51:01 2015 Page 1 ID:s3crybS_6sJgMSM2Sp�m_Dy9giz cugrs2mia3gChgNiih7am1 hylYZHJNnm20_pT0yPA38 1-1__ ___I-0 1 0-9-2 II 1-2-0 I -77�14a Scale:3/8"=1' 4x4= 3x4= 354= 3x4= 3x4= 3x4= 4x4= 3x4= 4x4= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 e -/`I,sIa'1,, I'!4 e e e e e e e e 3t 29 28 27 26 25 24 23 22 21 , 3x4 = 4x5 = 3x5 = 3x5 = 3x5= 3x5= 354= 3x5 = 4x5= 3x4= 12-9-10 I 11-7-10 111-2-101 I 18-11-8 11-7-10 0-7-0 0-7-0 6-1-14 Plate Offsets(X,Y)- 112:0-1-8,Edgel,f23:0-1-8,Edae1 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.47 Vert(LL) -0.28 25-26 >817 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.80 Vert(TL) -0.43 25-26 >522 360 BCLL 0.0 Rep Stress Ina YES WB 0.50 Horz(TL) 0.07 20 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:96 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.l&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS2x4 OF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc-bracing. REACTIONS. (lb/size) 30=828/0-2-12,20=828/0-4-4 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1500/0,3-4=1500/0,4-5=2612/0,5-6=2612/0,6-7=3346/0,7-8=3346/0, 8-9=-3697/0,9-10=3697/0,10-11=3697/0,11-12=3697/0,12-13=3396/0, 13-14=3396/0,14-15=2603/0,15-16=2603/0,16-17=1504/0,17-18=1504/0 BOT CHORD 29-30=0/800,28-29=0/2101,27-28=0/3024,26-27=0/3565,25-26=0/3730,24-25=0/3396, 23-24=0/3396,22-23=0/3033,21-22=0/2095,20-21=0/801 WEBS 13-23=423/0,2-30=-1120/0,2-29=0/981,4-29=-841/0,4-28=0/715,6-28=-577/0, 6-27=0/451,8-27=308/0,12-25=-59/618,18-20=-1122/0,18-21=0/984,16-21=827/0, 16-22=0/712,14-22=602/0,14-23=0/753 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)30. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ,�5 �NGINE�R �� 87022PE 9r / - �Aj, OREGO q) <t� 9On FM$ER \\ NO OS A. HECk EXPIRES:06/30/2017 October 27,2015 t 1 a WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED NITER REFERANCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek(9 connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the buidmg designer must verify the applicability of design parameters and properly incorporate this designminto the overall ■� building design.Bracing indicatedisto prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Niel('ek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delvery.erection and bracing of trusses and truss systems,see ANSI/TP11 QuaBly Crtleda,DSI-89 and BCSI BuBdfng Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. - Suite 109 Citrus Heiehts.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755185 PL15-354_UPPER F10 FLOOR 2 1 Job Reference(ootional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 0 Jul 11 2014 MTek Industries,Inc.Tue Oct 27 13:51:02 2015 Page 1 D:s3crybS_6sJgMSM2Sm_Dy9g1Z-4gEE3OnKLNy3JgyuGPepJ FEEKx4H2x6vGgjNOgy PA37 3x4 = I 0-11-11 I I 1-2-0 I I 0-10-1 I 1 1.5x3 II 2 3 3x4= 4 1.5x3 II Scale e 1:8.7 J N 1.5s3 II 1.5x3 II 8 7 6 3x4= 3x4 = I 3-5-12 I 3-5-12 Plate Offsets(X.Y)— f2:0-1-8.Edae1.f3:0-1-8,Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) -0.00 7 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.05 Vert(TL) -0.00 7 >999 360 BCLL 0.0 Rep Stress Ina YES WB 0.05 Horz(TL) 0.00 5 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:18 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-5-12 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 or,bracing, REACTIONS. (lb/size) 8=184/0-2-12,5=184/0-2-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8,5. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ���,Eo Pss �5 ;DG'i►vEROFF9 /02 87022PE 9r N ,N H �y SAT OREGO rL�At/ rer, 4'18ER 1\ Q� ....et A. HE�‘ EXPIRES:06/30/2017 October 27,2015 I 4 a WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE " Design valid for use only with MireSO connectors. Is design is based only upon parameters shown.and u for an individual butc cling component,not o truss system.Beforeuse,the building designer must verity-the appfcab7rly of design parameters and property incorporate thu design into the overall - building design. Bracing indicated is to prevent buckling of inddual truss web and/or chord members onN•Additional temporary and permanent bracing - Milek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/711 Quarry Criteria,DS6-89 and SCSI Building Component 7777Suite 109 Safely Information available from Truss Plate Institute,218 N.Lee Sheet,Suite 312,Alexandria,VA 22314. - - - Citrus Heiohts.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755186_1 PL15-354_UPPER F11 FLOOR GIRDER 1 1 Job Reference(ootional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 27 13:51:03 2015 Page 1 ID:s3crybS_6sJgMSM2Sm_D_y9giZ-ZsocHkoy6h4wx_X5g692rSnG?LDtnBy2VKTwYHyPA36 a��I 1-2-0 I1� 1 1-0-0 I al 7-9{1 1-2-0 10,7 Scale=1:33.3 3x4= 3x4= 3x4 II 4x4= 3x4= 3x4= 3x4= 3x4= 3x4= 3x4 = 5x6= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 ee' e e e e I:1 ' 3 31 30 28 27 26 25 24 23 22 21 3x4= 3x6= 4x5 = 3x5= 3x6= 3x5 = 3x5= 4x8= 3x4 = 1-1-0 11-8-0 12-0 I 36-12 8-8-5 3-5 -10.51 19-6-8 1-1-0 0.7-0 0.7-0 1-3-12 5-1-9 7-0 0.7-0 9-8-3 Plate Offsets(XX)- 12:0-1-8,EdgeL 13:0-1-8,Edae1,19:0-1-8,Edael,f10:0-1-8,Edael LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (roc) Vdefl lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.63 Vert(LL) -0.18 24-25 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.86 Vert(TL) -0.29 24-25 >668 360 BCLL 0.0 Rep Stress Ina NO WB 0.84 Horz(TL) 0.04 20 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:99 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 29=1347/0-7-0,32=164/0-1-12,20=1315/0-2-12 Max Uplift32=-269(LC 4) Max Grav29=1347(LC 1),32=60(LC 3),20=1318(LC 7) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=0/450,3-4=0/1096,4-5=0/1096,5-6=-610/0,6-7=610/0,7-8=1756/0, 8-9=-1756/0,9-10=2370/0,10-11=2900/0,11-12=2900/0,12-13=3113/0, 13-14=3113/0,14-15=2995/0,15-16=2995/0,16-17=2480/0,17-18=2480/0 BOT CHORD 31-32=450/0,30-31=-450/0,29-30=-450/0,27-28=0/1248,26-27=0/2370,25-26=0/2370, 24-25=0/2370,23-24=0/3031,22-23=0/3098,21-22=0/2793,20-21=0/1299 WEBS 2-31=-252/0,9-26=0/410,10-25=-331/0,2-32=0/665,3-29=-917/0,5-29=1249/0, 5-28=0/1047,7-28=898/0,7-27=0/716,8-27=11/251,9-27=1122/0,18-20=1819/0, 18-21=0/1654,17-21=839/0,16-21=-438/0,16-22=0/283,11-24=266/0,10-24=0/844 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)32,20. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to ���c O PR OF-,-. be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. �GJ �NGINEFR /O 6)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)791 lb down at 17-5-0 on top chord. �? 2 The design/selection of such connection device(s)is the responsibility of others. �� - 7)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). 87022 PE LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 (1) CV Uniform Loads(plf) S. "' N Vert:20-32=8,1-19=80 -7 '0), OREG •N rim Q<U Concentrated Loads(Ib) l /1.11o� sER \ C Vert:,7=7s1(F) s` A. HO; ‘4P EXPIRES:06/30/2017 October 27,2015 i Al WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII.7473 rev.10/0312015 BEFORE USE. __ Design vardfor use only with MTek®connectors.This design is based only upon parameters shown,and isfor an individual building component,not ' a truss system.Before use,the building designer must verify the applicab tty of design parameters and properly incorporate this design into the overall ..._ building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,deirery,erection and bracing of trusses and truss systems,see ANSI/TP11 Quality Criteria,DSI-89 and BCSI Building Component 7777 Greenback Lane Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45755187 PL15-354_UPPER F12 FLOOR 1 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 27 13:51:04 2015 Page 1 ID:s3crybS_6sJgMSM2Sm_Dy9giZ-13L_U4obt_CnY76HNggHOgJTJIdI WioCk_CT4jyPA35 0 i QH 1 1-2-0 1 11—o-� 1 2-6-0 I 2-4-9 i I 1-2-9 I I 1-9-7 l Scale=1:34.0 1.5x3 I I 3x4= 3x4= 3x4 II 3x6= 1.5x3 II 1.5x3 II 3x4= 1.5x3 II 3x5= 1.5x3 II 1 2 3 4 5 6 7 8 9 10 11 o N _ RIPe e �f ,1 pt.._ aH 19 18 17 16 15 14 13 12 3x4 =1.5x3 II 1.5x3 II 3x8= 3x5= 3x4= 3x6= 3x4 = I 3-6-12_ I B-8-5 p-3-5 10.51 19-6-4 I 3-6-12 5-1-9 b-7-0 7-0 9-7-15 Plate Offsets(X,Y)- 12:0-1-8,Edge1.f3:0-1-8,Edoe1.114:0-1-8,Edae1.115:0-1-8,Edsiel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (lac) 1/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.47 Vert(LL) -0.21 13-14 >913 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.59 Vert(TL) -0.33 13-14 >573 360 BCLL 0.0 Rep Stress Inc( YES WB 0.61 Horz(TL) 0.03 12 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:88 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 16=1117/0-7-0,19=60/0-1-12,12=649/0-2-12 Max Uplift19=166(LC 4) Max Gray 16=1117(LC 1),19=89(LC 3),12=651(LC 7) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=18/294,3-4=0/714,4-5=0/720,5-6=1980/0,6-7=1980/0,7-8=1980/0, 8-9=2148/0,9-10=2148/0 BOT CHORD 18-19=294/18,17-18=294/18,16-17=294/18,15-16=0/887,14-15=0/1980, 13-14=0/2325,12-13=0/1362 WEBS 6-15=345/0,2-19=-27/435,3-16=-616/0,5-16=1682/0,5-15=0/1201,10-12=1470/0, 10-13=0/849,8-14=-512/54 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)19,12. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. ���c ) P R OFer, k;::3 fix-- —.49. v0,,_ cc 870 2PE / c— N y cA>, OREGON q,9 O40 PO �MaERN1 OSA- HE¢\ EXPIRES:06/30/2017 October 27,2015 4 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MB-7473 rev.10/03/2015 BEFORE USE. 11111 Design valid for use only with MTek®connectors.This design is based only upon parameters shown.and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling ofindividual truss web and/or chord members only.Additional temporary and permanent bracing Malek° is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and buss systems,see ANSI/TP11 Qually Criteria.DSII-89 and ICSI Building Component 7777Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Sums Heights.CA 95810 Job Truss Truss Type Qty Ply POLYGON R45755188 PL15-354_UPPER F13 FLOOR 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 Mrrek Industries,Inc.Tue Oct 27 13:51:05 2015 Page 1 ID:s3cybS_65JgMSM2Sm Dy9giZ-VFvMiPpDdIKeAHgTxXBWxtskh966F1?Lzeylc9yPA34 3x4 = I 0-11-11 I I 1-2-0 I I 0-9-5 I 1 1.5x3 II 2 3 3x4= 4 1.5x3 II _ Scale=1:8.7 U --U 0 N 1 IS ■ \I. III 111 1111111:" 1.5x3 II 1.5x3 II 8 =' 7 6 5 3x4= 3x4= I 3-5-0 I 3-5-0 Plate Offsets(X,Y)— 12:0-1-8,Edoel,13:0-1-8,Edae1 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.04 Vert(LL) -0.00 7 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.04 Vert(TL) -0.00 7 >999 360 BCLL 0.0 Rep Stress Ina YES WB 0.04 Horz(TL) 0.00 5 n/a n/a BCDL 5.0 Code 1BC20121TP12007 (Matrix) Weight:18 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-5-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. _. WEBS 2x4 DF Stud/Std(flat) ROT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. • REACTIONS. (lb/size) 8=145/0-2-12,5=145/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. <0\1/4 PROF c4c\co NG(NFFR 0 /,29 870 2PE -7 NlAJ, OREGO ti O40 '9O, 'iiBER 1\ N rsA. HO; EXPIRES:06/30/2017 October 27,2015 1 t NE., a WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building coponent;not a.truss system.Before use,the budding designer must verify the applicability of design parameters and property incorporate this design into the overall budding design...Bracing indicated is to prevent buckdng of individual truss web and/or chord members only.Additional temporaryand permanent bracing -- MST@�C" isalwaysrequired for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the - 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/IP11 Qualify Criteria,D56-89 and ICS!Building Component Safety Information available horn Truss Plate Institute,218 N.Lee Sheet,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights.CA 95610 Symbols Numbering System A General Safety Notes PLATE LOCATION AND ORIENTATION s " Center plate on joint unless x,y 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause PropertyJu 1 /4 I I (Drawings not to scale) Damage or Personal In offsets are indicated. gInjury n = Dimensions are in ft-in-sixteenths. iii 4 Apply plates to both sides of truss 1 2 3 1. Additional stability bracing for truss system,e.g. and fully embed teeth. TOP CHORDS diagonal or X-bracing,is always required. See BCSI. 2. Truss bracing must be designed by an engineer.For Q'146" 4 wide truss spacing,individual lateral braces themselves may require bracing,or alternative Tor I �_� inipsio bracing should be considered. O3. Never exceed the design loading shown and never �-� ostack materials on inadequately braced trusses. O 4. Provide copies of this truss design to the building For 4 x 2 orientation,locate c7-8 C . �- designer,erection supervisor,property owner and plates 0 'Ag' from outside BOTTOM CHORDS all other interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each - This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully.Knots and wane at joint - required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment In accord with ANSI/TPI 1. *Plate location details available In MITek 20/20 NUMBERS/LETTERS. software or upon request. 8. Unless otherwise noted,moisture content of lumber shall not exceed 19%at time of fabrication. PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for PLATE SIZE use with fire retardant,preservative treated,or green lumber. ICC-ES Reports: The first dimension is the plate 10.Camber is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR 1311,ESR 1352,ESR 1988 responsibility of truss fabricator.General practice is to to slots.Second dimension is ER-3907,ESR 2362,ESR-1397,ESR-3282 camber for dead load deflection. the length parallel to slots. 11.Plate type,size,orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and in all respects,equal to or better than that / Indicated by symbol shown and/or Trusses are designed for wind loads in the plane of the specified. by text in the bracing section of the truss unless otherwise shown. 13.Top chords must be sheathed or purlins provided at output. Use T or I bracing spacing indicated on design. if indicated. Lumber design values are in accordance with ANSI/TPI 1 14.Bottom chords require lateral bracing at 10 ft.spacing, section 6.3 These truss designs rely on lumber valuesor less,if no ceiling is installed,unless otherwise noted. BEARING established by others. v/.-- 15.Connections not shown are the responsibility of others. Indicates location where bearings 16.Do not cut or alter truss member or plate without prior (supports) occur. Icons vary but ©2012 MiTek®All Rights Reserved approval of an engineer. reaction section indicates joint 1 ( number where bearings occur. 17.Install and load vertically unless indicated otherwise. ® Min size shown is for crushing only. Pill' 18.Use of green or treated lumber may pose unacceptable environmental,health or performance risks.Consult with project engineer before use. industry Standards: ANSI/TPII: National Design Specification for Metal 19.Review all portions of this design(front,back,words Plate Connected Wood Truss Construction. and pictures(before use.Reviewing pictures alone DSB-89: Design Standard for Bracing. a Is not sufficient.BCSI: Building Component Safety Information, 20.Design assumes manufacture in accordance with ' Guide to Good Practice for Handling, MiTekANSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev. 10/03/2015