Loading...
Report (44) s �►)Boise Cascade �� ��yy Single 11-7/8 BCI®5000-1.7 DF Upper LevellFloor JoistslJ1(i184) Dry 12 spans I Na cantilevers 10/12 slope September 7, 2016 16:16:51 BC CALC®Design Report 16 OCS I Repetitive I Glued&nailed construction Build 4340 File Name: 16-1781.mmdl Job Name: MISSION HOMES 3154 B Description: Designs\Floor Joists\Upper Level\Floor Joists\J1(i184 Address: - Specifier: PDG City,State, Zip:, Designer: Customer: PROBUILD FOREST GROVE Company: BOISE CASCADE BMD Code reports: ESR-1336 Misc: Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application.Output here based on building code-accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call (800)232-0788 before installation. BC CALC®,BC FRAMER®,AJSTM, ALLJOIST®,BC RIM BOARDTM,BCI®, BOISE GLULAMTT,SIMPLE FRAMING SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, VERSA-STRAND®,VERSA-STUD®are trademarks of Boise Cascade Wood Products L.L.C. Page 2 of 2 ' " �ol►)BoiseCascade Single 11-7/8" BCI®5000-1.7 DF Upper LevelWFloor JoistslJ5(i221) ��// Dry 12 spans 1 No cantilevers 1 0/12 slope September 7, 2016 16:16:51 BC CALC®Design Report 16 OCS I Repetitive I Glued&nailed construction Build 4340 File Name: 16-1781.mmdl Job Name: MISSION HOMES 3154 B Description: Designs\Floor Joists\Upper Level\Floor Joists\J5(i22' Address: - Specifier: PDG City,State,Zp:, Designer: Customer: PROBUILD FOREST GROVE Company: BOISE CASCADE BMD Code reports: ESR-1336 Misc: Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application.Output here based on building code-accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call (800)232-0788 before installation. BC CALC®,BC FRAMER®,AJSTM, ALLJOIST®,BC RIM BOARDT^',BCI®, BOISE GLULAMT",SIMPLE FRAMING SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, VERSA-STRANDS,VERSA-STUD®are trademarks of Boise Cascade Wood Products L.L.C. Page 2 of 2 " �Boise Cascade Single 11-7/8" BCI®60-2.0 DF Upper Level\Floor Joists1J12(i269) Dry 12 spans I No cantilevers 10/12 slope September 7, 2016 16:16:52 BC CALC®Design Report 16 OCS 1 Repetitive I Glued&nailed construction Build 4340 File Name: 16-1781.mmdl Job Name: MISSION HOMES 3154 B Description: Designs\Floor Joists\Upper Level\Floor Joists\J12(i2( Address: - Specifier: PDG City,State,Zp:, Designer: Customer: PROBUILD FOREST GROVE Company: BOISE CASCADE BMD Code reports: ESR-1336 Misc: Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application.Output here based on building code-accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call (800)232-0788 before installation. BC CALC®,BC FRAMER®,AJST'", ALLJOIST®,BC RIM BOARDTM,BCI®, BOISE GLULAMT^',SIMPLE FRAMING SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, VERSA-STRAND®,VERSA-STUD®are trademarks of Boise Cascade Wood Products L.L.C. Page 2 of 2 AS)�41►)Boisecascade Single 11-7/8" BCI®60-2.0 DF Upper LevelRFloorJoists\J8(i203) ``����// Dry 12 spans1 No cantilevers 1 0/12 slope September 7, 2016 16:16:52 BC CALC®Design Report 16 OCS I Repetitive I Glued&nailed construction Build 4340 File Name: 16-1781.mmdl Job Name: MISSION HOMES 3154 B Description: Designs\Floor Joists\Upper Level\Floor Joists\J8(i20: Address: - Specifier: PDG City,State,Zip:, Designer: Customer: PROBUILD FOREST GROVE Company: BOISE CASCADE BMD Code reports: ESR-1336 Misc: Design meets User specified (L/360)Total load deflection criteria. Disclosure Design meets User specified(L/480)Live load deflection criteria. Completeness and accuracy of input Design meets arbitrary(1")Maximum total load deflection criteria. must be verified by anyone who would Calculations assume Member is Fully Braced. rely on output as evidence of suitability Hanger Manufacturer: Simpson Strong-Tie, Inc. for particular application.Output here Composite El value based on 3/4"thick OSB sheathing glued and nailed to member. based on building code-accepted design Design based on Dry Service Condition. properties and analysis methods. Deflections less than 1/8"were ignored in the results. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call (800)232-0788 before installation. BC CALC®,BC FRAMER®,MST", ALLJOIST®,BC RIM BOARDTM,BCI®, BOISE GLULAMTM,SIMPLE FRAMING SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, VERSA-STRAND®,VERSA-STUD®are trademarks of Boise Cascade Wood Products L.L.C. Page 2 of 2 Boise Cascade Single 11-7/8" BCI®90-2.0 DF Upper Level\Floor Joists1J13(i176) Dry 12 spans I Left cantilever 10/12 slope September 7, 2016 16:16:52 BC CALC®Design Report r 16 OCS I Repetitive I Glued&nailed construction Build 4340 File Name: 16-1781.mmdl Job Name: MISSION HOMES 3154 B Description: Designs\Floor Joists\Upper Level\Floor Joists\J13(i1 Address: - Specifier: PDG City,State,Zip:, Designer: Customer: PROBUILD FOREST GROVE Company: BOISE CASCADE BMD Code reports: ESR-1336 Misc: Design meets User specified (L/360)Total load deflection criteria. Disclosure Design meets User specified (L/480) Live load deflection criteria. Completeness and accuracy of input Design meets arbitrary(1")Maximum total load deflection criteria. must be verified by anyone who would Design meets arbitrary(1")Cantilever Maximum total load deflection criteria. rely on output as evidence of suitability Calculations assume Member is Fully Braced. for particular application.Output here Composite El value based on 3/4"thick OSB sheathing glued and nailed to member. based on building code-accepted design Design based on Dry Service Condition. properties and analysis methods. Deflections less than 1/8"were ignored in the results. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call (800)232-0788 before installation. BC CALC®,BC FRAMER®,AJST"", ALLJOIST®,BC RIM BOARDT"',BCI®, BOISE GLULNvITM,SIMPLE FRAMING SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, VERSA-STRAND®,VERSA-STUD®are trademarks of Boise Cascade Wood Products L.L.C. Page 2 of 2