COMcheck Software Version 4.0.8.0 OF I COPY
Interior Lighting Compliance
Certificate REEVE.
Section 1: Project Information FEB 2018
B TIGARD Code:2014 Oregon Energy Efficiency Specialty Code `'�TY 'OF
Project Title:Lovesac-Washington Square 3UILDING D!V S1ON
Project Type:Alteration
Construction Site: Owner/Agent: Designer/Contractor:
9585 S.W.Washington Sq.Rd. Lovesac Shremshock Engineering, Inc.
Space#T03 2 Landmark Square 7400 West Campus Road
Portland,OR 97223 Suite#300 Suite#150
Stamford,CT 06901 New Albany,OH 43054
Section 2: Interior Lighting and Power Calculation
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B x C)
Sales Area(Retail:Sales Area)(Ceiling Height 11 ft.) 870 1.5 1305
Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID:F2 200(a) 1.4 216(b)
Allowance:Furniture,clothing,cosmetics highlighting/Fix.ID:F4 20(a) 1.4 28(b)
Restroom(Common Space Types:Restrooms)(Ceiling Height 8 ft.) 68 0.82 56
Non-sales(Common Space Types:Active Storage)(Ceiling Height 12 ft.) 140 0.63 88
Total Allowed Watts= 1693
(a)Area claimed may exceed total floor area when Retail Merchandise Highlighting allowance(s)are specified.
(b) Allowance is(B x C)or the actual wattage of the fixtures given in Section 2,whichever is less.
Section 3: Interior Lighting Fixture Schedule
A B C D E
Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Sales Area(Retail:Sales Area 870 sq.ft.)
Sales Display Lighting:F2:Directional LED Downlight:LED PAR 16W: 1 12 18 216
Sales General Downlighting:F3:Fixed LED Downlight: LED PAR 16W: 1 10 18 180
Sales General Downlighting:F4:Adjustable LED Multiple:Other: 3 12 36 432
Show Window Lighting(Enclosed):F4:Adjustable LED Multiple:Other: 3 2 36 Exempt
Exemption:Retail Display Window
Show Window Lighting(Open):F4:Adjustable LED Multiple:Other: 3 2 36 72
Restroom(Common Space Types:Restrooms 68 sq.ft.)
General Downlighting:F3:Fixed LED Downlight:LED PAR 16W: 1 2 18 36
Non-sales(Common Space Types:Active Storage 140 sq.ft.)
LED:L1:2'x4',LED:Other: 1 1 51 51
Total Proposed Watts= 987
Section 4: Requirements Checklist
In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks
identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in
the plans/specs the requirement can be verified as being satisfied.
Lighting Wattage:
`/ 1. Total proposed watts must be less than or equal to total allowed watts.
Allowed Wattage: 1693 Proposed Wattage:987
Complies:YES
Project Title: Lovesac-Washington Square Report date: 02/19/18
1
Mandatory Requirements:
✓ 2. Exit signs.Internally illuminated exit signs shall not exceed 5 watts per side.
Plans reference page/section: E200
3. Daylight zone control.All daylight zones are provided with individual controls that control the lights independent of general area lighting
in the non-daylight zone.In all individual daylight zones larger than 350 sq.ft.,automatic daylight controls is provided.Automatic
daylight sensing controls reduce the light output of the controlled luminaires at least 50 percent,and provide an automatic OFF control,
while maintaining a uniform level of illumination.Contiguous daylight zones adjacent to vertical fenestration may be controlled by a
single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations(i.e.,north,east,
south,west).Daylight zones under skylights shall be controlled separately from daylight zones adjacent to vertical fenestration.
Plans reference page/section:Not Applicable
`/ 4. Interior lighting controls.At least one local shutoff lighting control has been provided for every 2,000 square feet of lit floor area and
each area enclosed by walls or floor-to-ceiling partitions.The required controls are located within the area served by the controls or are
a remote switch that identifies the lights served and indicates their status.
Plans reference page/section: E200
✓ 5. Sleeping unit controls.Master switch at entry to hotel/motel guest room.
Plans reference page/section: Not Applicable
✓ 6. Egress lighting.Egress illumination is controlled by a combination of listed emergency relay and occupancy sensors to shut off during
periods that the building space served by the means of egress is unoccupied.
Plans reference page/section: E200
✓ 7. Additional controls. Each area that is required to have a manual control shall have additional controls that meet the requirements of
Sections 505.2.2.1 and 505.2.2.2.
Plans reference page/section: E200
✓ 8. Light reduction controls.Each space required to have a manual control also allows for reducing the connected lighting load by at least
50 percent by either
1)controlling(dimming or multi-level switching)all luminaires;or
2)dual switching of alternate rows of luminaires,alternate luminaires,or alternate lamps;or
3)switching the middle lamp luminaires independently of other lamps;or
4)switching each luminaire or each lamp.
Plans reference page/section: 5200
✓ 9. Buildings larger than 2,000 square feet are equipped with an automatic control device to shut off lighting in those areas.This automatic
control device shall function on either:
1)a scheduled basis,using time-of-day,with an independent program schedule that controls the interior lighting in areas that do not
exceed 10,000 square feet and are not more than one floor;or
2)an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space;or
3)a signal from another control or alarm system that indicates the area is unoccupied.
Plans reference page/section: E200
✓ 10.Occupancy sensors in rooms that include daylight zones are required to have Manual ON activation.
Plans reference page/section: Not Applicable
✓ 11.An occupant sensor control device is installed that automatically turns lighting off within 30 minutes of all occupants leaving a space.
Plans reference page/section: E200
✓ 12Additional controls.An occupant sensor control device that automatically turns lighting off within 30 minutes of all occupants leaving a
space or a locally activated switch that automatically turns lighting off within 30 minutes of being activated is installed in all storage and
supply rooms up to 1000 square feet.
Plans reference page/section: E200
13.Occupant override.Automatic lighting shutoff operating on a time-of-day scheduled basis incorporates an override switching device
that: 1)is readily accessible,2)is located so that a person using the device can see the lights or the area controlled by that switch,or
so that the area being lit is annunciated,3)is manually operated,4)allows the lighting to remain on for no more than 2 hours when an
override is initiated,and 5)controls an area not exceeding 2,000 square feet.
Plans reference page/section: E200
✓ 14.Holiday scheduling.Automatic lighting shutoff operating on a time-of-day scheduled basis has an automatic holiday scheduling feature
that turns off all loads for at least 24 hours,then resumes the normally scheduled operation.
Plans reference page/section: E200
{
`/ 15.Exterior lighting controls.Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination of a
photosensor and a time switch,or an astronomical time switch.Lighting designated for dusk-to-dawn operation shall be controlled by
an astronomical time switch or photosensor.
Plans reference page/section: Not Applicable
v 16.Tandem wiring.The following luminaires located within the same area shall be tandem wired:
1. Fluorescent luminaires equipped with one,three or odd-numbered lamp configurations,that are recess-mounted within 10 feet
center-to-center of each other.
2.Fluorescent luminaires equipped with one,three or any odd-numbered lamp configuration,that are pendant-or surface-mounted
within 1 foot edge-to-edge of each other.
Plans reference page/section: Not Applicable
v 17.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control
of the nonexempt lighting.
Plans reference page/section: Not Applicable
v 18.Each dwelling unit in a building is metered separately.
Plans reference page/section: Not Applicable
Interior Lighting PASSES
Section 5: Compliance Statement
Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,specifications and
other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2014 Oregon Energy
Efficiency Specialty Code requirements in COMcheck Version 4.0.8.0 and to com ma ory requirements in the Requirements
Checklist.
Reece A.Prather-P.E., Principal C .QAC
Name-Title Signature Date
Project Title: Lovesac-Washington Square Report date: 02/19/18
Agnes Lindor
From: Agnes Lindor
Sent: Monday, March 05,2018 8:46 AM
To: tims@elderjones.com
Cc: #Building Permit Technicians;#CD PoD
Subject: LoveSac
Tim-
Before we can issue your permit for LoveSac.A minor modification is required for a change of use from Retail Sales'to
Bulk Sales. Here is the application: http://www.tigard-
or.govicity hall/departments/CommunityDevelopment/Minor Modification Application.pdf
The process takes about 1 week and the fee is$303.The application submittal requirements are located in the update
right hand corner.Thanks,
Agnes Lindor I Associate Planner
City of Tigard f Community Development
13125 SW Hall Boulevard
Tigard, Oregon 97223
Phone:503.718.2429
Email:AgnesL a(�t jgard-or.gov
DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail
may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E-mails are retained
by the City of Tigard in compliance with the Oregon Administrative Rules "City General Records Retention Schedule."
1
Branden Taggart
From: Branden Taggart
Sent: Monday, March 5, 2018 9:08 AM
To: tims@elderjones.com
Cc: #Building Permit Technicians;#CD PoD
Subject: RE: LoveSac
Importance: High
Tim,
Since a minor modification is required by our planning department, we cannot proceed with the building permit plan
review until the minor modification has been approved. Once you have received approval, please let us know, and we
will proceed with plan review for the tenant improvement permit.
Thanks,
Brandin Taggart
ISa City of Tigard
M Senior Permit Technician
Community Development
Til'ciAR
13125 SW Hail Blvd
Tigard,OR 97223
(503)718-2449
brandent@tigard-or gov
From:Agnes Lindor
Sent: Monday, March 5, 2018 8:46 AM
To:tims@elderjones.com
Cc:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov>;#CD PoD<CDPoD@tigard-or.gov>
Subject: LoveSac
Tim-
Before we can issue your permit for LoveSac.A minor modification is required for a change of use from Retail Sales'to
Bulk Sales. Here is the application: http://www.tigard-
or.gov/city half/departments/CommunityDevelopment/Minor Modification Application.pdf
The process takes about 1 week and the fee is$303.The application submittal requirements are located in the update
right hand corner.Thanks,