Report / L:7 2- w
CS79a,6tg' c
`lc NORTHyi,
Fs
"t,ENE
����N PACIFIC NORTHWEST OR'FIIW EST ENGINEERI NG. INC.
Structural inspection for:
El Guajillo Restaurant
12725 SW Pacific Hwy APR 19 20113
Tigard, OR 97223
971-294-9897
1)-Scope: The scope of the Inspection involves the Client's intention to move
the kitchen entry wall approximately 24" towards the front of the building, add a
reach-through opening with a stainless steel counter at the reach-through
opening, then add a second screen wall at approximately 96" from the kitchen
entry wall with a door opening at each end, and a decorative window at center to
obscure the view so that customers cannot see directly into the kitchen area.
2)-Purpose: The purpose of the inspection was to determine the structural
value, if any, of the existing kitchen entry separation wall, and kitchen ceiling
framing. A visual inspection of the area listed above was performed by a
representative Pacific Northwest Engineering Inc on 04/15/2018, in addition to
photos taken of the affected walls & ceiling framing members there were also
dimensions taken to determine the possible structural loading of the wall being
removed.
3)-Findings: After a thorough review of the project, the photos, and the building
structure at the time of site inspection. we find that the walls & ceiling framing
influenced by the proposed remodel project are simply non-structural in manor of
supporting the roof and or any second story loads and are void of any structural
value to the building. Also, the new walls will impose now new loads on the
basement structure. It is therefore determined by our findings that the alteration -
or- removal of the aforementioned framing walls will have absolutely no affect
whatsoever on the building's structural integrity. We also find that this remodel
will have no change on the "Code Summary" of the existing structure.
4)-Code Summary: The code summary is not changed by this remodel and is theret'ore,
as follows:
Zone Commercial
Construction Type VB
Occupancy Group A-2
l3uilding Area (L•xistin2):
Basement 274 Sq. Ft.
Main Floor 3,465 Sq. Ft.
Mezzanine 794 Sq. Ft.
Total 4.536 Sq. Ft.
4242 Silver Falls Dr. N., Silverton, OR. 97381
ph # (503) 873-3184 fax # (503) 873-3907
P.E. # 13,076
P E
I'VEE I!�G'' � NORTHWEST
r INC .PACIFIC 1\ ORTHVI�EST ENGINEERING, C
Building Area (Allowable): 6.000 Sq. Ft.
If you have any questions, please feel free in calling me.
Thank You.
a
Mak Ellingson. P.E.
President
C:woRk.1311 LINGS( IAJILEO-A)I DO(
•
4242 Silver Falls Dr. N., Silverton, OR. 97381
ph # (51)3) 873-3184 fax # (503) 873-3907
P.E.# 13,676