Loading...
Specifications , /Pt s id-ae" -06/72_ - qs-eis— skti itt,1-4424, OFFICE COPY OUELLETTE ENGINEERING INC. 33720 NE KRAMIEN RD. NEWBERG, OR 97132 (503) 925-1469 STRUCTURAL CALCULATIONS PROJECT: BAYHA RESIDENCE PATIO COVER 9545 SW RIVERWOOD LN. TIGARD, OR 97224 JOB NO. 18-09A 3/20/2018 PAGE 1 OF it _.ts.13 CT URitt 40 P I Wire, „,,,":- 61118474VA' ''': . 14 u, 4 1•Po A4 la/ / I iv' Vi'v' e ' i di -c 41,, 4 v- 411123,2trke OUS-\- 'EXPIRES: (2 -ii-f8 ] P 1olect: ,< page •-- Jay Ouellette r Lkcation:RFT3Ouellette Engineering Inc. Roof Rafter 33720 NE Kramien Rd. of [2015 International Building Code(2012 NDS)] ."'_' -: Newberg,Oregon 97132 1.5 INx7.25INx10.5FT(9+ 1.5)@24O.C. #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 2/16/2018 3:20:57 PM Section Adequate By:93.4% Controlling Factor: Moment DEFLECTIONS Center Right LOADING DIAGRAM Live Load 0.11 IN L/1058 0.01 IN 2L/5290 Dead Load 0.06 in 0.00 in Total Load 0.17 IN L/665 0.00 IN 2L/Infinity Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240 REACTIONS A B Live Load 225 lb 306 lb Dead Load 138 lb 194 lb Total Load 363 lb 500 lb Bearing Length 0.39 in 0.53 in SUPPORT LOADS A B Live Load 113 plf 153 plf Dead Load 69 plf 97 plf -- 9 ft — --- 1.5 ft J Total Load 182 plf 250 plf MATERIAL PROPERTIES #2-Douglas-Fir-Larch RAFTER DATA Interior Eave Base Values Adjusted Span Length 9 ft 1.5 ft Bending Stress: Fb= 900 psi Fb'= 1428 psi Rafter Pitch 4 :12 Cd=1.15 CF=1.20 Cr-1.15 Roof sheathing applied to top of joists-top of rafters fully braced. Shear Stress: Fv= 180 psi Fv'= 207 psi Roof Duration Factor 1.15 Cd=1.15 Peak Notch Depth 0.00 Modulus of Elasticity: E= 1600 ksi E= 1600 ksi Base Notch Depth 0.00 Comp.1 to Grain: Fc- 1 = 625 psi Fc-1'= 625 psi RAFTER LOADING Controlling Moment: 809 ft-lb Uniform Roof Loading 4.411 Ft from left support of span 2(Center Span) Roof Live Load: LL= 25 psf Created by combining all dead loads and live loads on span(s)2 Roof Dead Load: DL= 15 psf Controlling Shear: -358 lb Slope Adjusted Spans And Loads 8.538 Ft from left support of span 2(Center Span) Interior Span: L-adj= 9.49 ft Created by combining all dead loads and live loads on span(s)2,3 Eave Span: L-Eave-adj= 1.58 ft Interior Live Load: wL-adj= 45 plf Comparisons with required sections: Redd Provided Eave Live Load: wL-Eave-adj= 45 plf Section Modulus: 6.79 in3 13.14 in3 Interior Dead Load: wD-adj= 28 plf Area(Shear): 2.6 in2 10.88 in2 Eave Dead Load: wD-Eave-adj= 28 plf Moment of Inertia(deflection): 17.18 in4 47.63 in4 Interior Total Load: wT-adj= 73 plf Moment: 809 ft-lb 1564 ft-lb Eave Total Load: wT-Eave-adj= 73 plf Shear: -358 lb 1501 lb NOTES 5 /c5 ,21110450 - L / c. page Project: ag = / Jay Ouellette e ,.., Location: ROOF BEAM ,' , Ouellette Engineering Inc. Roof Beam ' 33720 NE Kramien Rd. of [2015 International Building Code(2012 NDS)] fir:-"::` . Newberg, Oregon 97132 5.51N x 12.0 IN x 24 0 FT 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 10.0.1.6 2/20/2018 2:04:31 PM Section Adequate By: 7 7% Controlling Factor: Deflection DEFLECTIONS Center LOADING DIAGRAM Live Load 0.68 IN L/423 Dead Load 0.43 in Total Load 1.11 IN L/258 Live Load Deflection Criteria.L/360 Total Load Deflection Criteria: L/240 REACTIONS A B Live Load 1560 lb 1560 lb Dead Load 994 lb 994 lb Total Load 2554 lb 2554 lb Bearing Length 0.71 in 0.71 in BEAM DATA Span Length 24 ft .� . _ .I, ,_ .g Unbraced Length-Top 0 ft 24 ft — Unbraced Length-Bottom 0 ft Roof Pitch 4 :12 Roof Duration Factor 1.15 ROOF LOADING MATERIAL PROPERTIES Side One: 24F-V4-Visually Graded Western Species Roof Live Load: LL= 20 psf Base Values Adjusted Roof Dead Load: DL= 10 psf Bending Stress: Fb= 2400 psi Controlled by: Tributary Width: TW= 5 ft Fbcmpr= 1850 psi Fb'= 2704 psi Side Two: Cd—=1.15 Cv=0.98 Roof Live Load: LL= 20 psf Shear Stress: Fv= 265 psi Fv'= 305 psi Roof Dead Load: DL= 10 psf Cd=1.15 Tributary Width: TW= 1.5 ft Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi Comp.1 to Grain: Fc-1= 650 psi Fc-1'= 650 psi Wall Load: WALL= 0 plf Controlling Moment: 15323 ft-lb SLOPE/PITCH ADJUSTED LENGTHS AND LOADS 12.0 ft from left support Adjusted Beam Length: Ladj= 24 ft Created by combining all dead and live loads. Beam Self Weight: BSW= 14 plf Controlling Shear: 2554 lb Beam Uniform Live Load: wL= 130 plf At support. Beam Uniform Dead Load: wD_adj= 83 plf Created by combining all dead and live loads. Total Uniform Load: wT= 213 plf Comparisons with required sections: Read Provided Section Modulus: 68 in3 132 in3 Area(Shear): 12.57 in2 66 in2 Moment of Inertia(deflection): 735.4 in4 792 in4 Moment: 15323 ft-lb 29746 ft-lb Shear: 2554 lb 13409 lb NOTES page Project: — .Jay Ouellette Location: FTG1tttA Ouellette Engineering Inc. ./ Footing 33720 NE Kramien Rd. of [2Q15 International Building Code(2012 NDS)] -. , Newberg,Oregon 97132 Footing Size 2.0 FT Round Diameter X 18.00 IN Deep Section Footing Design Adequate StruCalc Version 10.0.1.6 3/20/2018 10 55 10 AM CAUTIONS 1 *Footing has been designed without reinforcement FOOTING PROPERTIES LOADING DIAGRAM Allowable Soil Bearing Pressure: Qs= 1500 psf Concrete Compressive Strength: Fc= 2500 psi I Reinforcing Steel Yield Strength Fy= 40000 psi Concrete Reinforcement Cover: c= 3 in FOOTING SIZE r Diameter: Dia. = 2 ft Effective Depth to Top Layer of Steel: d= 16 in 1— COLUMN AND BASEPLATE SIZE ` L ___ __ _ Column Type: Wood Column Width: m= 4 in Column Depth: n= 4 in FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Qu= 828 psf Effective Allowable Soil Bearing Pressure:Qe= 1275 psf Required Footing Area: Areq= 2.04 sf 18 in', Area Provided: A= 3.14 sf Baseplate Bearing: Bearing Required: Bear= 3760 lb Allowable Bearing: Bear-A= 37400 lb Beam Shear Calculations(One Way Shear): Beam Shear: Vu1 = 0 lb Allowable Beam Shear Vc1 = 12478 lb Punching Shear Calculations(Two Way Shear): 3 in Critical Perimeter: Bo= 80 in 1 Punching Shear: Vu2= 435 lb _—. 2 ft I Controlling Allowable Punching Shear: vc2= 93632 lb Bending Calculations: Factored Moment: Mu= 9997 in-lb FOOTING LOADING Nominal Moment Strength: Mn= 124781 in-lb Live Load: PL= 1600 lb Dead Load: PD= 1000 lb NOTES Total Load: PT= 2600 lb Ultimate Factored Load: Pu= 3760 lb Footing plus soil above footing weight: Wt= 456 lb Litt } : rt / y- I� 7 5 )06- vt4,6 r .. LJ A-0 z 73 kr ------- .r :==- Albert Shields From: Albert Shields Sent: Monday,April 16, 2018 2:36 PM To: 'dave_saalfeld@msn.com' Subject: FW: MST2018-00112, Patio Cover Attachments: Albert Shields.vcf;4-9-18 site plan.pdf;Copper Creek Plat.pdf From:Albert Shields Sent: Monday,April 16,2018 2:34 PM To: 'dave_salfeld@msm.com'<dave_salfeld@msm.com> Cc: Mike White<MikeW@tigard-or.gov> Subject: MST2018-00112, Patio Cover Dave,on reviewing your plans for MST2018-00112, Engineering has requested that you revise your site plan to show the following: 1. Show correct street, i.e.,SW Riverwood Lane. 2. Show 5 ft utility easements along front and rear property lines. 3. Show 5 ft storm drainage easement along east property line in favor of lots 83 &84. 4. Show actual elevations above sea level at property corners. A redlined copy of your submitted site plan is attached as is a copy of the Copper Creek Stage 3 plat showing 1, 2, &3 above. Please let me know if you have any questions. Albert Shields City of Tigard Permit Coordinator (503j 716-242 6 Wo rk Albert ctigard-or.gov 13125 SW Hall Blvd. Tigard,Oregon 97217 www.tigard-or.gov 1