Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
cPI,S1-oif- cre--if , \Ilk r r k ( I •••••••• .•: COSCO OFFICE COPY *::::. Fire Protection • 1 iie plum:11On 0,141 i lie Sa ply Spei iiiliqs APR 1 9 7018 cl;ii 01 CW,ii,77i ni-\•PO'-Th.-)N PLEASE PROVIDE PROVIDE EITHER COMPLETED NFPA 13 . FLEXIBLE SPRINKLER MATERIAL AND TEST :::::, HEAD OR 2-INCH CERTIFICATE AT OVERSIZE RINGS FINAL INSPECTION OR. INTERP 10-01 .re Protection Material tSubmittal • Fred Meyer _ 75 - Tigard Tigard, Oregon COSCO Fire Protection Inc. Job # 24PD5202 • 2501 SE Columbia Way, Suite 100 Vancouver,WA 98661 Phone:360-883-6383 Fax: 360-883-6390 Toll Free:800-983-6383 :::::::: COSCO Fire Protection vire note,(ion will Life tits frit Sl�eci�li.4i+ Sprinklers • COSCO Fire Protection Inc. • 2501 SE Columbia Way, Suite 100 Vancouver,WA 98661 Phone:360-883-6383 Fax: 360-883-6390 Toll Free:800-983-6383 June 28, 2013 Sprinkler 11q ® MICROMATIC®AND TECHNICAL DATA MicromaticHP® STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Micromatic® and MicromaticHP® Standard Response Upright and „ _ Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature rat- • ings, and K-Factors to meet design requirements. The special Polyester, t Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings 1 i can be used in decorative applications where colors are desired. In addition, ` I$' these coatings have been investigated for installation in corrosive atmospheres !' w and are listed/approved as corrosion resistant as indicated in the Approval 84( Chart. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corro- sion resistant.) y Viking standard response sprinklers may be ordered and/or used as open sprin- klers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions on page 11r. 2. LISTINGS AND APPROVALS c Ot us cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, and 2016 NYC Approved: MEA 89-92-E, Volumes 3 and 12 VdS ABS Certified: Certificate 04-HS407984B-PDA VdS Approved: Certificates G4060055, G4980001, G4980003, G4980004, G4980006, and G4980008 LPC Approved: Ref. No. 096e106 CE CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40137, 0786-CPD-40142, 0786-CPD-40177, and 0786-CPD-40182 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on pages 11t-u for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 11v for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1997. Viking Technical Data may be found on Minimum Operating Pressure: 7 psi (0.5 bar)* The Viking Corporation's Web site at Maximum Working Pressure: Sprinklers VK021 and VK124 are rated for http://www.vikinggroupinc.com. use with water working pressures ranging from the minimum 7 psi The Web site may include a more recent (0.5 bar)up to 250 psi(17 bar)for high-pressure systems. High-pres- edition of this Technical Data Page. sure (HP) sprinklers can be identified by locating "250" stamped on the deflector.All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar)wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to-65 °F (-55 °C) Overall Length: Refer to the Approval Charts *cULus vals Listing,ONLY FM Approval, andbarNFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approis 5 psi(0.35 ). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 09993, 12986, 10227,and 10233. Brass UNS-C84400 for all other sprinklers. Form No. F_080106 Replaces page 11q-v, dated June 11, 2013. (ENT finish is now approved as corrosion resistant.) June 11r 28, 2013 MICROMATIC®AND NIKING® MicromaticHP® STANDARD • TECHNICAL DATA RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Deflector:Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 12986 and 12993.Copper UNS-C19500 for Sprinklers 10141, 10169, 10174, 10220, and 10233. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 09995, 10191, 10192, 10218, and 10219): Brass UNS-C36000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap for Sprinkler 09993: Brass UNS-C31400 or UNS-C31600. Pip Cap and Insert Assembly for all other Sprinklers: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment(for Sprinklers 09995, 10192, and 10218): Brass UNS-C36000 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap- ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Micromatic® and MicromaticHP® Standard Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, Black Polyester = M-/B, and Black PTFE = N, Wax Coated = C, Wax Over Polyester=V-/W, ENT=JN Temperature Suffix(°F/°C): 135°/68° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, 212°/100° = M, 286°/141° = G, 360°/182° = H, 500°/260° =L, OPEN = Z (PTFE only). For example, sprinkler VK100 with a 1/2"thread, Brass finish and a 155°F/68 °C temperature rating = Part No. 12986AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000) B. Wrench for wax-coated sprinklers: Part No. 13577W/B** (available since 2006) **A'/2'ratchet is required(not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B.Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Micromatic® and MicromaticHP® Standard Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. June 28, 2013 Sprinkler 11s -01 ® MICROMATIC®AND TECHNICAL DATA MicromaticHP® STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES N ,t Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green Intermediate 212 °F(100 °C) 150 °F (65 °C) Green High 286 °F(141 °C) 225 °F (107 °C) Blue Extra High 360 °F(182 °C) 300 °F (149 °C) Mauve Ultra High' 500 °F(260 °C) 465 °F (240 °C) Black Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings°:White Polyester, Black Polyester,and Black PTFE in all temperature ratings. ENT in all tempurature ratings except 135 °F(57 °C). Wax-Coated Brass and Wax over Polyesters for sprinklers with the following temperature ratings: 135 °F(57 °C) Off-White Wax 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 212 °F (100 °C) Dk. Brown Wax6 286 °F(141 °C)Dk. Brown Wax6 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 'Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300 °F(149°C).Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300°F(149°C), response time may be severely retarded. "The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment.For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester,ENT,and PTFE coatings.For PTFE coated open sprinklers only,the waterway is coated. For ENT coated sprinklers,the waterway is coated. Wax Over Polyester is unavailable for Sprinklers VK021 and VK124. 6 Wax melting point is 170°F(76°C)for 212°F(100°C)and 286°F(141 °C)temperature rated sprinklers. Protective Sprinkler Wrench Cap Flat S • 10896 ©()� • Figure 1: Standard Sprinkler Wrench 10896W/B , Sprinkler lit June 28, 2013 MICROMATIC®AND IP* NliuNG® TECHNICAL DATA MicromaticHP® STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Listings and Approvals' Base Part SIN Thread Size Nominal K-Factor Overall Length (Refer also to Design Criteria on page 11u.) Number' NPT BSP U.S. metric2 Inches mmcULus4 NYCE VdS LPCB Mil 013 U•ri•ht-Standard Orifice 12986 VK100 1/2" 15 mm 5.6 80.6 2-3/16 56 Al B4 C5 D3 F6 See Footnote 7. -- -- -- -- 10233 VK145 1/2" 15 mm 5.6 80.6 2-3/16 56 -- -- A2 A2 B4 A2 E2 10174 VK145 -- 15 mm 5.6 80.6 2-3/16 56 -- -- A2 A2 B4 -- -- 12993 VK100 -- 15 mm 5.6 80.6 2-3/16 56 Al B4 C5 D3 F6 Al B4 C5 -- -- -- -- U•ri•ht-Lar•e Orifice 1022014 VK200 1/2" 15 mm 8.0 115.2 2-3/8 60 Al B4 C5 D3 F6 Al B4 A2 -- E3 E3 10141 VK200 3/4" 20 mm 8.0 115.2 2-5/16 59 Al B4 C5 D3 F6 Al B4 C5 A2 A2 E3 E3 10169 VK200 -- 20 mm 8.0 115.2 2-5/16 59 Al B4 C5 D3 F6 -- A2 A2 E3 E3 U•ri•ht-Small Orifice9 1021810 VK001 1/2" 15 mm 2.8 40.3 2-3/16 56 Al B4 C5 s -- -- 1021910 VK002 1/2" 15 mm 4.2 57 2-3/16 56 Al B4 C5 See Footnote 7. -- -- -- -- 1019110 VK002 -- 15 mm 4.2 57 2-3/16 56 Al B4 C5 -- -- -- -- -- 1019210 VK001 -- 15 mm 2.8 40.3 2-3/16 56 Al B4 C5 -- -- -- -- -- Conventional-Standard Orifice 10227 VK118 1/2" 15 mm 5.6 80.6 2-3/16 56 Al B4 Al B4 A2 A2 B4 A2 WWI 10172" VK118 -- 15 mm 5.6 80.6 2-3/16 56 Al B4 -- -- A2 B4 -- i Conventional-Lar•e Orifice 10228 VK120 3/4" 20 mm 8.0 115.2 2-5/16 59 Al B4 Al B4 A2 A2 E3 E2 1016811 VK120 -- 20 mm 8.0 115.2 2-5/16 59 Al B4 -- A2 A2 E3 E3 Maximum 250 PSI (17 bar)WWP Upright-Standard Orifice 09993 VK124 1/2" 15 mm 5.6 80.6 2-1/4 58 Al D3 See Footnote 7. -- -- -- -- U•ri•ht-Small Orifice9 099959 VK021 1/2" 15 mm 2.8 40.3 2-1/4 58 Al See Footnote 7. -- -- -- -- Approved Temperature Ratings A- 135°F (57 °C), 155°F (68°C), 175°F (79°C), 200°F (93 °C),286°F Approved Finishes (141 °C),and 360°F(182°C) 1 -Brass,Chrome,White Polyesters,Black Polyesters,and Black PTFE5 B- 135°F(57°C), 155°F(68°C), 175°F(79°C),and 200°F(93°C) 2-Brass,Chrome,White Polyester,and Black Polyester C-286°F(141 °C) 3-Brass and Chrome D-500°F(260°C)8 4-Wax-Coated Brass and Wax over Polyesters E - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), and 5-200 °F (93 °C) High-Temperature Wax Coating (corrosion resistant); 360°F(182°C) maximum ambient temperature allowed at ceiling= 150°F(65°C) F- 155"F(68"C), 175°F(79°C),200°F (93°C),286°F(141 °C),360°F 6-ENT' (182°C),and 500°F(260°C)8 Footnotes 1 Base part number is shown. For complete part number,refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 4Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. 5cULus Listed as corrosion resistant. 6 Upright sprinklers Accepted for use,City of New York Department of Buildings, MEA Number 89-92-E,Vol. 12. Conventional sprinklers accepted for use, City of New York Department of Buildings, MEA Number 89-92-E,Vol.3. 'Meets New York City requirements,effective July 1,2008. 8 Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300 °F (149 °C).Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149°C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 9 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied,with hydraulically calculated wet syste only.Exception:4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanize• 10The sprinkler orifice is bushed. "Sprinklers 10168 and 10172 are available on special order. 12((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40137, 0786-CPD-40142, 0786-CPD-40177, 0786-CPD-40182, 0832- CPD-2001,and 0832-CPD-2003. 13 St MED Certified,Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. 14 The 1/2"NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. June 28, 2013 Sprinkler 11u !NiluNG® MICROMATIC®AND 40: TECHNICAL DATA MicromaticHP® STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com cULus Listing Reauirements: Micromatice and MicromaticHP®Standard Response Upright and Conventional Sprinklers are cULus Listed as indicated in the Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style(conventional)sprinklers. • Designed for use in Light, Ordinary, and Extra Hazard occupancies. (Small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception:4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized.) • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional sprinklers,refer to the installation guidelines for old style(conventional)sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Sprinkler Ww ust 13577W1 1 /B must be used for installing wax 1111 coated sprinklers Step 1: Carefully slide the wrench sideways around the deflector, ensuring engagement ,aw r,g with the sprinkler �= '1141 � wrench flats, il�� I � 1 ! 9/ Wax Coated Upright Sprinkler i I A( A 1/2" ratchet is required Step 2: Carefully press the wrench (not available from Viking). downward and ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 13577W/B for Wax Coated Sprinklers • June 28, 2013 Sprinkler 11v MICROMATIC®AND TECHNICAL DATA MicromaticHP® STANDARD 0 NII(INGe RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Base Part Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN NPT BSP U.S. metric2 Inches mm (Refer also to Design Criteria below.) Standard Orifice 12986 VK100 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, C5, E6, Fl, G4, H7 10233 VK145 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, D2, E6, Fl 10174 VK145 -- 15 mm 5.6 80.6 2-3/16 56 Al, D2, Fl 12993 VK100 -- 15 mm 5.6 80.6 2-3/16 56 Al, D2, Fl, G4, H7 Large Orifice 10220' VK200 1/2" 15 mm 8.0 115.2 2-3/8 60 Bl, D5, Fl, H7 115.2 2-5/16 59 B1, D5, Fl, H7 10141 VK200 3/4" 20 mm 8.0 10169 VK200 -- 20 mm 8.0 115.2 2-5/16 59 B1, D5, Fl, H7 Small Orifice4 102186 VK001 1/2" 15 mm2.8 40.3 2-3/16 56 D3, D5 101926 VK001 -- 15 mm 2.8 40.3 2-3/16 56 D3, D5 Approved Temperature Ratings A- 135°F(57°C), 155°F(68°C), 175°F(79°C),200°F(93°C),212°F(100°C), Approved Finishes 286°F(141 °C),and 360°F(182°C) 1 -Brass,Chrome,White Polyester,and Black Polyester B 135°F(57°C), 155°F(68°C), 175°F(79°C),200°F(93°C),286°F(141 °C), 2-White Polyester and Wax-Coated Brass(corrosion resistant) and 360°F(182°C) 3-Brass and Chrome C-135°F(57°C),155°F(68°C),175°F(79°C),200°F(93°C),and 212°F(100°C) 4-Wax-Coated Brass and Wax over Polyester D-135°F(57°C), 155°F(68°C), 175°F(79°C),and 200°F(93°C) 5-Wax-Coated Brass(corrosion resistant) E-286°F(141 °C) 6 - 200 °F (93 °C) High-Temperature Wax Coating (corrosion F-500°F(260°C)5 resistant); maximum ambient temperature allowed at ceiling G- 155°F(68°C) = 150°F(65°C) H-155°F(68°C),175°F(79°C),200°F(93°C),286 °F (141 °C), 360 °F (182 °C), 7-ENT8 500°F(260°C)5 Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. ' FM Approved as standard response Non-Storage upright sprinklers. For specific application and installation requirements, reference the latest ap- plicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). 5 Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300°F (149 °C).Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 6 The sprinkler orifice is bushed. 'The 1/2"NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. 8 FM approved as corrosion resistant. FM Approval Reauirements: The sprinklers indicated in Approval Chart 2 are FM Approved as standard response Non-Storage upright sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design ceiling slope and obstructions,minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT:Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Also refer to page SR1-3 for gen- eral care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FMn Global, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes,ordinances, and standards,whenever applicable. Replaces page 11q-v, dated June 11, 2013. Form No. F_080106 (ENT finish is now approved as corrosion resistant.) Page 1 of 7 ® MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Micromatic® Standard Response Pendent VK102 Sprinkler is a small, thermosen- sitive, glass-bulb spray sprinkler available in several different finishes and temperature rat- ings to meet design requirements. The special Polyester, Polytetrafluoroethylene (PTFE), _ and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in cor- rosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed)on deluge systems. Refer to Ordering Instructions. 2. LISTINGS AND APPROVALS ' ceus cULus Listed: Category VNIV ..M FM Approved: Class Series 2000 VdS VdS Approved: Certificate G414006 &G414004 (sLPC LPCB Approved CE CE Certified:Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2021 ` CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and UL Design Criteria on pages cULus Listing requirements, and refer to Approval Chart 2 and FM Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)t Maximum Working Pressure: 175 psi (12 bar)wwp Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*") Glass-bulb fluid temperature rated to-65 °F (-55 °C) Viking Technical Data may be found on Overall Length: 2-1/4" (57 mm) The Viking Corporation's Web site at t cULus Listing,FM Approval,and NFPA 13 installs require a minimum of 7 psi(0.5 bar). http://www.vikinggroupinc.com. The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). The Web site may include a more recent Material Standards: edition of this Technical Data Page. Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000tt or Copper UNS-C19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers: Belleville Spring- Exposed, Screw and Pipcap- ENT plated. Form No. F__031414 Rev 15.3 Page 2 of 7 NIKING® MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) III The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com ttNot for FM Approval. Ordering Information: (Also refer to the current Viking price list.) Order Micromatic®Standard Response Pendent VK102 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, Black PTFE = N, Wax Coated = C, Wax Over Polyester=V-/W, ENT=JN Temperature Suffix: 135 °F (57 °C)=A, 155 °F (68 °C) = B, 175°F (79 °C) = D, 200 °F (93 °C)= E, 212 °F (100 °C)= M, 286 °F (141 °C)=G, 360 °F (182 °C)= H, 500 °F (260 °C)= L, OPEN =Z(PTFE only). For example, sprinkler VK102 with a 1/2"thread, Brass finish and a 155 °F (68 °C)temperature rating = Part No. 12987AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B* (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) D.Wrench for Wax Coated Sprinklers: Part No. 13577W/B* (available since 2006) *A'/2'ratchet is required(not available from Viking). **Allows use from the floor by attaching a length of 1"diameter CPVC tubing to the tool. Ideal for sprinkler cabinets.Refer to Bulletin F_051808. • Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector,forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Micromatic®Standard Response Pendent Sprinkler VK102 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. III Form No. F_031414 Rev 15.3 Page 4 of 7 MICROMATIC® STANDARD NIKING® TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler Nominal Listings and Approvals' p Thread Size K-Factor Overall Length Base Part SIN (Refer also to UL Design Criteria.)Number' NPT BSP U.S. metria Inches mm cULusa VdS LPCB CE 8 == Standard Orifice 12987 VK102 1/2" 15 mm 5.6 80.6 2-1/4" 57 Al,B4,B1Y,C5,D3,E6,G6Z A2 A2,B4,B2Y F2,G2Y -- E7 12989 VK102 -- 15 mm 5.6 80.6 2-1/4" 57 Al,B4,BIY,C5,D3,E6,G6Z A2 A2,B4,B2Y F2,G2Y -- -- NOTICE-Product Below-Limited Availability(Contact Local Viking Office) 10139 VK102 1/2" 15 mm 5.6 80.6 2-1/4" 57 Al,B4,B1Y,C5,D3,E6,G6Z - -- -- -- - 10173 VK102 15 mm 5.6 80.6 2-1/4" 57 Al,64,B1Y,C5,D3,E6,G6Z A2 A2,B4,B2Y -- -- 18020 VK102 1/2" 15 mm 5.6 80.6 2-1/4" 57 Al,B4,BIY,C5,D3,E6,G6Z A2 A2,B4,B2Y F2,G2X F29,1° -- Approved Temperature Ratings A- 135 °F (57 °C), 155°F (68°C), 175 °F (79 Approved Finishes °C), 200 °F (93 °C), 286 °F (141 °C), and 360 °F(182°C) 1 -Brass,Chrome,White Polyester®", Black Polyester5.6, Approved Escutcheons B- 135°F(57 °C), 155°F (68 °C), 175°F(79 and Black PTFES X - Recessed with the Viking Micromatic® Model °C),and 200°F(93°C) 2-Brass,Chrome,White Polyesters,and Black Polyesters E-1,E-2,or E-3 Recessed Escutcheon C-286°F(141 °C) 3-Brass and Chrome Y - Standard surface-mounted escutcheon or the D-500°F(260°C)7 4-Wax-Coated Brass and Wax Over Polyesters Viking Microfast®Model F-1 Adjustable Escutcheo E 155°F (68 °C), 175°F (79°C), 200 °F (93 5 or recessed with the Viking Micromatic®Model E- E-2,or E-3 Recessed Escutcheon °C), 286°F(141 °C), 360°F(182°C), and 500 sion resistant);maximum ambient temperature allowed at °F(260°C)' ceiling=150°F(65°C) Z Standard surface-mounted escutcheon or re - F with the Viking Micromatic®Model E-1 F- 155 °F (68 °C), 175°F (79°C),200 °F (93 6-ENT' °C),286°F(141 °C), and 360°F(182°C) 7-Chrome G-155°F(68°C), 175°F(79°C), and 200°F (93°C) Footnotes 1 Base part number is shown.For complete part number,refer to Viking's current price schedule. 2Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 'Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. 5 cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300°F(149°C).Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300°F(149°C),the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 8 CE Certified,Standard EN 12259-1,EC-certificate of conformity 0832-CPD-0021. 9 MED Certified,Standard EN 12259-1,EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. 10 MED Certified,RINA Certificate No.MED497705C5. cULus Listing Requirements: The Viking Micromatic®Standard Response Pendent Sprinkler VK102 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light, Ordinary,and Extra Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT:Always refer to Bulletin Form No.F_091699-Care and Handling of Sprinklers.Also refer to page SR1-3 for ge eral care,installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA, LPCB,APSAD,VdS or other similar organizations,and also with the provisions of governmental codes, ordinances, and standards,whenever applicable. Form No. F_031414 Rev 15.3 Page 5 of 7 MICROMATIC® STANDARD NIKING® TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler BaseThread Size Nominal K-Factor Overall Length FM Approvals3 Part Number' SIN NPT BSP U.S. I metric2 Inches l mm (Refer also to Design Criteria below.) Standard Orifice 12987 VK102 1/2" 15 mm 5.6 80.6 2-1/4" 57 Al,B2,C3, D1, E4, GIY,G4Z 12989 VK102 -- 15 mm 5.6 80.6 2-1/4" 57 Al, B2,C3, D1,E4,G1Y,G4Z NOTICE-Product Below-Limited Availability(Contact Local Viking Office) 10139 VK102 1/2" 15 mm 5.6 80.6 2-1/4" 57 Al,B2,C3, D1, E4,G1Y,G4Z 10173 VK102 -- 15 mm 5.6 80.6 2-1/4" 57 Al, B2,C3,D1,E4,G1Y,G4Z 18020 VK102 1/2" 15 mm 5.6 80.6 2-1/4" 57 Al, B2,C3,D1,G1Y Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 212 °F (100 °C), •286°F(141 °C),and 360°F(182°C) Approved Finishes Approved Escutcheons B-135°F(57°C), 155°F(68°C), 175°F(79°C),200°F 1 - Brass, Chrome, White Polyester", and Y - Standard surface-mounted escutch- (93°C),and 212°F(100°C) Black Polyester' eon or the Viking Microfast® Model F-1 C-286°F(141 °C) 2-Wax-Coated Brass(corrosion resistant) Adjustable Escutcheon or recessed with the D-500°F(260°C)5 3 - High Temperature 200 °F (93 °C) Wax Viking Micromatic® Model E-1, E-2, or E-3 Coating (corrosion resistant); maximum am- Recessed Escutcheon E-155°F(68°C), 175°F(79°C),200°F(93°C),286°F bient temperature allowed at the ceiling (141 °C), 360°F(182°C),and 500°F(260°C) = Z - Standard surface mounted escutcheon 150°F(65°C) or re- cessed with the Viking Micromatic® F - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 4-ENT6 Model E-1 , 200°F(93°C) G- 155°F(68°C), 175°F(79°C),and 200°F(93°C) Footnotes 1 Base part number is shown.For complete part number,refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300°F(149°C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300°F(149°C),the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 6 FM approved as corrosion resistant. FM Approval Requirements: The Viking Micromatic®Standard Response Pendent Sprinkler VK102 is is FM Approved as standard response Non-Storage pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design,ceiling slope and obstructions, minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT:Always refer to Bulletin Form No. F 091699-Care and Handling of Sprinklers.Also refer to page SR1-3 for gen- eral care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards,whenever applicable. Form No. F_031414 Rev 15.3 Page 1 of 6 4INIKING® TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry sys- tems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry Pendent Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and - Electroless Nickel PTFE (ENT) coatings have been investigated for installation in gl corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) 111 NOTE: When installed in some corrosive environments, the Polyester finish may change color.This natural discoloration over time is not in itself an indica- tion of corrosion and should not be treated as such.All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. 2. LISTINGS AND APPROVALS co. cULus Listed: Category VNIV Fc FM Approved: Classes 2013 and 2015 NYC Approved: MEA 89-92-E Volume 15 Refer to Approval Chart 1 and Design Criteria on page 105d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 105e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 100 psi (6.89 bar) Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*)for all listed and approved lengths. *Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65 °F (-55 °C) Covered by the following U.S. Patents:8,636,075 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Viking Technical Data may be found on PTFE Tape The Viking Corporation's Web site at Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 http://www.vikinggroupinc.com. Pip Cap Adapter: Brass UNS-C36000 The Web site may include a more recent Orifice: Copper UNS-C22000 or UNS-C11000 edition of this Technical Data Page. Tube: ERW Hydraulic Steel Tube Support(Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 Form No. F_031793 Rev 15.1 Page 2 of 6 QUICK RESPONSE TECHNICAL DATA DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-530400 Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ("A" dimension)to sprinkler base part number. Order in a specific length noted as the "A" dimension. The "A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm)for the adjustable standard style,3"to 47"(76.2 mm to 1,194 mm)for the plain barrel style,and 3-1/4"to 47-1/2" (82.5 mm to 1,207 mm)for the adjustable recessed style. Lengths exceeding the standard lengths are available,with no approvals,on a"made-to-order"basis:Recessed Dry Pendent up to 65-1/2" (1,664 mm).Adjustable Standard Dry Pendent up to 63-1/2"(1,613 mm). Plain Barrel Dry Pendent up to 65"(1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass =A, Chrome = F,White Polyester= M-/W, and ENT=JN Temperature Suffix: 155 °F (68 °C) = B, 175°F (79 °C)= D, 200 °F (93 °C)= E, 286 °F (141 °C) = G For example, sprinkler VK176 with a Chrome finish and a 155 °F (68 °C) temperature rating, and "A" length of 10" = Part No. 08383U FB 10. Available Finishes And Temperature Ratings: Refer to Table 1. Wrench Accessories: (Also refer to the"Sprinkler Accessories" section of the Flat Viking data book.) TIN .�� Protective �'�l Sprinkler Sprinkler Wrenches: razurrtriea 111 Shield A. Standard Wrench: Part No. 07297W/B (available since 1991) p B. Wrench for recessed sprinklers: Part No. 07565W/B** 11'`�ISI (available since 1991) **A'/2'ratchet is required(not available from Viking). Sprinkler Guard: Chrome,with no listings or approvals, for installation on dry pendent sprinklers made after May 1994 only(Part No. 08954). Replacement Escutcheons: VIKING 07297 O A.Adjustable Standard Dry Escutcheon: Base Part No. 07741 B. Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. INSTALLATION Figure 1: Standard Sprinkler Wrench 07297W/B Refer to appropriate NFPA Installation Standards. 5. OPERATION -mom mom During fire conditions,the heat-sensitive liquid in mo the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the �� waterway.Water flowing through the sprinkler a � orifice strikes the sprinkler deflector,forming a sprinkler wrench uniform spray pattern to extinguish or control the fire. o7565w/B*) must be used for Installing 6. INSPECTIONS,TESTS & MAINTENANCE recessed dry sprinklers Refer to NFPA 25 for Inspection, Testing and 11�==s�l� Maintenance requirements. Step 2Cnrefully press �14� I ��� 7. AVAILABILITY II I ��4110 � the wrench upward and i�. The Viking Quick Response Dry Pendent Sprink- 4`i turn slightly to ensure 4`, � ler is available through a network of domestic engagement with the and international distributors. See The Viking r sprinkler wrench flats' Corporation web site for the closest distributor step 1 carefully A 1/2" ratchet is f f or contact The Viking Corporation. slide the wrench required (Not avail lip sideways around the ill able from Viking) 8. GUARANTEE sprinkler deflector. For details of warranty, refer to Viking's current Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers list price schedule or contact Viking directly. Form No. F_031793 Rev 15.1 Page 3 of 6 41NIKING® TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES 0r s s Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F(65 °C) Green High 286 °F(141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating3'4: White Polyester and ENT in all temperature ratings Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 'The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Note:These coatings are NOT cor- rosion proof. Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environ- 0 ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. 4 When installed in some corrosive environments,the Polyester finish may change color.This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such.All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. For "A" Dimension: 1. Determine the distance from the face of the tee to the finished ceiling. 2. Round to the nearest 1/2" (12,7 mm) between 1-1/2" and 45-1/2" (38,1 mm and 1,156 mm), NOTE: The deflector will be located approximately 3-7/16" (87.3 mm) below the ceiling. with 1" (25.4 mm) upward and 1" (25,4 mm) downward adjustment. Deflector at minimum distance below ceiling. ,UN❑TES I���, di To locate the deflector ).. -r at the minimum distance below the ceiling, with I I no downward adjustment A Minimum ceiling opening W-7/16" available, order the diameter: 1-3/4" (44.5 mm). (61.9 mm) dry pendent sprinkler Maximum ceiling opening II[_ Minimum 1" (25.4 mm) shorter diameter: 2-1/4" (57 mm). than the "A" dimension, I=I 13/16" 1NOTE: ® Finished i (20,6 mm) To locate the deflector Ceiling Mill\ at the maximum distance i� 4- 7/16" below the ceiling, with 1 1/2" (112.7 mm) no downward adjustment (38.1 mm) -I- Sleeve finish matches escutcheon. Maximum diameter _1_ available, order the Ipendent sprinkler 3-1/16" �:_ 1" (25.4 mm) longer (77.8 mm) than the "A" dimension, Deflector at maximum distance below ceiling. Figure 3: Adjustable Standard Dry Pendent Sprinkler Form No. F_031793 Rev 15.1 Page 4 of 6 QUICK RESPONSE 0 NutaNG TECHNICAL DATA DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Thread Size Nominal K-Factory Order Length Increment SIN Style Listings and Approvals° Sprinkler (Refer also to Design Criteria below.) Base Part No.' pa BSP U.S. metric' Inches mm cULus5 NYC6 VdS LPCB ® G 08383U Adjustable® -- 5.6 80.6 1/2" 12.7 A1,A5 Al -- IIMPA VK176 Standard 25 mm -- 80.6 16457U 1/2" 12.7 Al,A5 -- IN -- =.1. 08385U Adjustable® -- 5.6 80.6 1/4" 6.35 62, 66 B2 -- VK180 RecessedIII 25 mm -- 80.6 16453U 1/4" 6.35 B2,B6 -- III -- MMI 08387U Plain ® 5.6 80.6 1/2" 12.7 A3 A4 in -- �M 16455U VK172 Barrel 25 mm -- 80.6 1/2" 12.7 A3 -- -- �MM Approved Finishes and"A" Dimensions 1-Chrome or White Polyester'sprinkler with a Chrome or White Polyester Sleeve and Escutcheon Approved Temperature Ratings with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) A- 155 °F (68 °C), 175 °F (79°C), 200 °F (93 °C), 2-Chrome or White Polyester'with"A"dimensions 3-1/4"to 47-1/2"(82.5 mm to 1,207 mm) and 286°F(141 °C) 3-Chrome,Brass,White Polyester',or ENT'with"A"dimensions 31'1944n:1(m)to 7 76.2 mm to 1,194 mm) /2" - 155 °F (68 °C), 175 °F (79°C), and 200 °F 4-Chrome or Brass with"A"dimensions 3"to 47"(76.2 mm to , (93°C) 5 - ENT' sprinkler with an ENT' Sleeve and Escutcheon with "A" dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) 6-ENT'with"A"dimensions 3-1/4"to 47-1/2"(82.5 mm to 1,207 mm) Footnotes 1 Part number shown is the base part number. For complete part number,refer to current Viking price list schedule. 2 K-Factor applies for standard lengths("A"Dimensions indicated above). 3 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 4 This chart shows the listings and approvals available at the time of printing.Other approvals may be in process.Check with the manufacturer for any additional approvals. 5 Listed by Underwriter's Laboratories for use in the U.S.and Canada. 6 Accepted for use,City of New York Department of Buildings,MEA Number 89-92-E,Vol. 15. 'cULus Listed as corrosion resistant. NOTE:When using CPVC fittings with Viking dry sprinklers,use only new Nibco Model 5012-S-Bl tees.When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Standard DryPendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac� cordance with the latest edition of Viking technical data,the appropriate standards of NFPA, LPCB,APSAD,VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_031793 Rev 15.1 Page 5 of 6 4NIKING® TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com � rte Sprinkler Base SIN St le Thread Size Nominal K-Factor2 Order Length Increment FM Approvals4 Part No.1 y NPT BSP U.S. metric3 Inches mm (Refer also to Design Criteria below.) 08383U VK176 Adjustable Standard 1" -- 5.6 80.6 1/2" 12.7 Al 16457U -- 25 mm -- 80.6 1/2" 12.7 Al 08385U VK180 Adjustable Recessed 1" 5.6 80.6 1/4" 6.35 B2 16453U -- 25 mm -- 80.6 1/4" 6.35 B2 08387U 1" -- 5.6 80.6 1/2" 12.7 A3 16455U VK172 Plain Barrel -- 25 mm -- 80.6 1/2" 12.7 A3 Approved Temperature Ratings Approved Finishes and"A"Dimensions A-155°F(68°C), 175°F(79°C),200°F(93°C), 1 - Brass, Chrome, White Polyester, or ENT'sprinkler with a Brass, Chrome, White Polyester, or and 286°F(141 °C) ENT5 Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) 2-Brass,Chrome,White Polyester,or ENT5 with"A"dimensions 3-1/4"to 47-1/2"(82.5 mm to 1,207 mm) B-155°F(68°C), 175°F(79°C),and 200°F(93°C) 3-Brass,Chrome,White Polyester,or ENT5 with"A"dimensions 3"to 47"(76.2 mm to 1,194 mm) Footnotes ' Part number shown is the base part number. For complete part number,refer to current Viking price list schedule. 2 K-Factor applies for standard lengths("A"Dimensions indicated above). 3 Metric K-Factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 100. • °This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. 5 FM approved as corrosion resistant. SLS NOTE:When using CPVC fittings with Viking dry sprinklers,use only new Nibco Model 5012-S-BI tees.When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Reauirements: The Dry Pendent Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements,reference the latest applicable FM Loss Prevention Data Sheets(includ- ing 2-0)and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT:Always refer to Bulletin Form No. F 091699-Care and Handling of Sprinklers.Also refer to page DRY1-3 for general care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA, FM Global, LPCB,APSAD,VdS or other similar organizations,and also with the provisions of governmental codes, ordinances,and standards,whenever applicable. I _ l0I' 11111F4111011 Uj•IHO 4--- -__—_-_-_- ___f.6 For "A" Dinension 41 1. Determine the distnce from face of tee ato TFor "A" Dimension: the finished ceiling =Mm 1. Determine the A 2. Round to nearest 1/4" A Minimum ceiling opening 6.35 mm) between distance from 2-1/8" (54 mm) diameter, 3-1/4" (82.5 mm) and Outside the face of the 47-1/2" (1,207 mm). diameter tee to the base 1-5/16" of the sprinkler. Maximum ceiling opening: p 2-1/2" (63 5 mm) diameter, NOTE Sprinkler will be 33.4 mm) 2. Round up to the same as recessed approximately next highest 1/2" 5/16' (79 mm) above the finished ceiling with cent(25 mm) (12.7 mm) incre Schedule 40 pipe) between 3' , and Adjustment. 5/8' (15.8 mm) vertical 47" (1,194 mm). 5/16" (7,9 mm)� ,_=-1-TI adjustment available, 5/16" (7,9 mTm) —':: - ,__`---- Finished ceiling 1 1-5/8" Minimum: 1" (25,4 mm) I .J (48,3 mm) Maximums 1-5/8" (421 mm) —3-1/16" (77.9 rnm)- �wiN-- Form No. F OF3i�if 4Re FlimtIble Recessed Dry Pendent Sprinkler Figure 5: Plain Barrel Dry Pendent Sprinkler Page 6 of 6 1111144 IIIKII NG@ QUICK RESPONSE TECHNICAL DATA DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Exposed Barrel Ambient Install 1 inch NPT threaded Deflector at Ambient Install t Temperature 40°F/4°C�50°F/SO°C60'F/16°C / end of dry pendent sprinkler minimum distance 1of Protected into the 1 inch NPT outlet below ceiling Areas at the Exposed Minimum Barrel of a malleable iron tee fitting Discharge End Length** Face of Tee /� per ANSI B 16.3 (Class 150) to Top of Ceiling `) Up to 2' (50,8 mm) of the Sprinkler or cast iron threaded tee fitting In. (mm) In, (mm) In, (nm) adjustment available. 40°F (4°C) 0 0 0 4_- _='s per ANSI 16.4 (Class 125) only. 30°F (-1°C) 0 0 0 Note: Minimum ceiling opening diameterI To locate the 20°F (-7°C) 4 (100) 0 0 1-3/4' (44,5 mm) deflector at the 10°F (-12°C) 8 (203) 1 (25.4) 0 (Exposed Maximum ceiling opening diameter: I minimum distance Barrel) 2 7/16" below the ceiling, 0°F (-18°C) 12 (305) 3 (76) 0 �_ g, 2 1/4" (57 mm), (61.9 mm) with no upward -10°F (-23°C)14 (356) 4 (102) 1 (25.4) -20°F (-29°C)14 (356) 6 (152) 3 (76) / Seal the clearance Mini`um adjustment avail IL space around the able, order the -30°F 16 (406)6 (203)4 (102) P dry pendent sprink- -40°F (-40°C)18 (457) 8 <203>4 <102> sprinkler to avoid leak- ler 1" (25.4 mm) -50°F (-46°C)20 (508)10 (254)6 (152) ® age of air into the 1 shorter than the -60°F (-51°C)20 (508)10 (254)6 (152) _ 13/16' protected area and �I�'moi 'A' dimension. (20,6 mm) consequents formation EIWIFIFFICeiling-1 -- of condensate around NERT r' the frame, which could Note: / inhibit operation or To locate the Sleeve finish cause premature opera- 4 7/16' deflector at the 1-1/2' (38.1 mm) - tion, Refer to Figure (112.7 mm) maximum distance diameter matches 7below, below the ceiling, escutcheon Maximum with no downward If humidity and temp- adjustment avail- 3-1/16' erature differential able, order the (Protected Area) causes condensation .. dry pendent sprink- (77.8 mm) on the exposed dry ler 1' (25.4 mm) • sprinkler, consider longer than the wrapping the exposed Deflector at 'A' dimension. barrel with insulation, maximum distance foam insulating tape, below ceiling or equivalent. wThe protected area refers to the area below the ceiling. The ambient temperature is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. / The minimum required barrel length is not the same as the "A" dimension. Refer to Figures 3-5 for the "A" dimension, NOTE: Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities, Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is Shown) Seal ■ (or equivalent method) Seal III ,/ ii ii oio i i _ ri ii ii Clearance ® Insulated IlMr ❑pening III Ceiling IIII i!- I• • Dry Sprinkler Seal on the Dry Sprinkler Seal Within the Ceiling Exterior of the Ceiling Figure 7: Dry Sprinkler Seal(Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_031793 Rev 15.1 :••••• COSCO Fire Protection • Iii 1'rowl:lion n)lrj life Snfc[p Sj�ecirtlisis Pipe & Fittings • COSCO Fire Protection Inc. • 2501 SE Columbia Way, Suite 100 Vancouver,WA 98661 Phone:360-883-6383 Fax: 360-883-6390 Toll Free:800-983-6383 r State Pipe & Supply, Inc. THIS INFORMATION PROVIDED IS BASED ON ASTM GUIDELINES FOR WELDED PIPE SPECIFICATIONS AND ASTM REQUIREMENTS. ACTUAL PIPE AND MATERIAL TEST REPORTS PROVIDED WOULD MEET OR EXCEED THESE GUIDELINES. TEST REPORTS WOULD PROVIDE SPECIFIC AND ACTUAL DETAILS CONCERNING THE MECHANICAL AND CHEMICAL PROPERTIES OF THE ACTUAL PIPE,AS WELL AS ADDITIONAL TESTS RESULTS REQUIRED BY ASTM. SCHEDULE 10**Black and Galvanized Steel ERW Pipe Pipe Size Test Pressure Nominal O.D. I.D. Weight/Foot psi 1" 1.315 1.097 1.410 700 1-1/4" 1.660 1.442 1.810 1200 1-1/2" 1.900 1.682 2.090 1200 2" 2.375 2.157 2.640 2300 2-1/2" 2.875 2.635 3.530 2500 3" 3.500 3.260 4.340 1290 • 4" 4.500 4.260 5.620 1000 5" 5.563 5.295 7.780 1010 6" 6.625 6.357 9.300 1020 8"-- 8.625 _ 8.249 16.960 780 **8"wall thickness is 0.188,not SCH10 or 0.148"wall thickness. COMPOSITION AND PROPERTIES Chemical and mechanical properties requirements are as prescribed by applicable ASTM standards edition January 2006. Chemical Requirements,Percent(Product) C 1 Mn P S I Other Specification I Grade max max max max ASTM A53 I A 0.250 0.950 0.05 0.045 - 1 Residual elements max:Cu-0.40,Ni-0.40,Cr-0.40,Mo-0.15 and V-.08. These live elements combined shall not exceed 1%. Mechanical Properties-Tensile Requirements Strength-psi. Yield Tensile Specification ] Grade Min Max Min 1 Max ASTM A53 A 30,000 - 48,000 NOTE: Elongation requirements vary with nominal area of test specimen and specified minimum tensile strength • of the steel grade. 1 r 9615 S. Norwalk Blvd.,Santa Fe Springs,CA 90670 •(562),695.5555 •FAX:(562)692-1054 =www.statepipe.com • State Pipe & Supply, Inc. THIS INFORMATION PROVIDED IS BASED ON ASTM GUIDELINES FOR WELDED PIPE SPECIFICATIONS AND ASTM REQUIREMENTS. ACTUAL PIPE AND MATERIAL TEST REPORTS PROVIDED WOULD MEET OR EXCEED THESE GUIDELINES. TEST REPORTS WOULD PROVIDE SPECIFIC AND ACTUAL DETAILS CONCERNING THE MECHANICAL AND CHEMICAL PROPERTIES OF THE ACTUAL PIPE,AS WELL AS ADDITIONAL TESTS RESULTS REQUIRED BY ASTM. SCHEDULE 40 Black and Galvanized Steel ERW Pipe Pipe Size Test Pressure Nominal O.D. ID. Weight 1 Foot psi 1" 1.315 1.049 1.680 700 1-1/4" 1.660 1.380 2.270 1200 1-1/2" 1.900 1.610 2.720 1200 2" 2.375 2.067 3.660 2300 2-1/2" 2.875 2.469 5.800 2500 3" 3.500 3.068 7.580 2220 4" 4.500 4.026 10.800 1900 5" 5.563 5.047 14.630 1670 • 6" 6.625 6.065 18.990 1520 8" 8.625 7.981 28.580 1340 COMPOSITION AND PROPERTIES Chemical and mechanical properties requirements are as prescribed by applicable ASTM standards edition January 2006. Chemical Requirements,Percent(Product) C Mn P S' Other Specification Grade max max max max ASTM A53 A 0.250 0.950 0.05 0.045 - 1 Residual elements max:Cu-0.40,Ni-0.40,Cr-0.40,Mo-0.15 and V-.08. These live elements combined shall not exceed 1%. Mechanical Properties-Tensile Requirements Strep th-psi. Yield Tensile Specification Grade Min Max Min Max ASTM A53 A 30,000 - 48,000 - NOTE: Elongation requirements vary with nominal area of test specimen and specified minimum tensile strength of the steel grade. S 9615 S. Norwalk Blvd.,Santa Fe Springs,CA 90670 •(562)695-5555 •FAX:(562)692-1054 •www.statepipe.com i Victaulic® Vic-FlexTM Sprinkler Fittings Series AH2 Braided Flexible Hose htauiicr . . F I exTM z----f-d,- ; 1.0 PRODUCT DESCRIPTION Available Sizes by Component • Series AH2 Braided Hose: 31, 36, 48, 60, 727790, 914, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.757140 mm straight reducer. • Sprinkler Reducers: 1/2" and 3/x'/15 and 20 mm sprinkler connections and 5.757140 mm, 97230 mm, 137330 mm straight lengths and short, long 90"elbows. Note: The short 90° elbow is typically used with concealed sprinklers while the long 90"elbow is typically used in the installation of recessed pendent sprinklers. • Adapter Nipples: 1"/25mm NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFPA standards. 3/4"/20mm NPT or BSPT available for VdS. 11/a"/32mm BSPT available for LPCB. • Brackets: • Style AB1 for suspended and hard-lid ceilings, allows installation before most ceiling tiles in place • • Style AB2 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB8 for hard-lid ceilings with CD 60/27 profile metal studs (regionally available) • Style AB9 for hard-lid ceilings with hat furring channel grid systems • Style AB10 for Armstrong®TechZoneT" ceilings Maximum Working Temperature • 225°F/107°C Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) • ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. • System No. Location Spec Section Paragraph Submitted By Date Approved Date • • victaulic.com 1A OC 00711 D....V I I..,J..1,.,.1 11/nrv,c ,,7/110\/I.....,I...1,..........-.,. All.:,.4.1.....,.,...•,..J , victaulic.com • 1.0 PRODUCT DESCRIPTION (Continued) i Connections • To adapter nipple (inlet) via 1'/25.4 mm NPT or BSPT male thread OR • To adapter nipple (inlet) via 3/4"/20 mm BSPT male thread(VdS only) • To sprinkler head (outlet) via 1/2" or 3/4715 mm or 20 mm Minimum Bend Radius • 7"/178 mm (FM Approval) • 2"/51 mm (cULus Listed) • 3'/76.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K-Factors • FM (1/2"/15mm reducer) K5.6/8,1 (S.I.), (3/4°/20mm reducer) K14.0/20,2 (Si.) • cULus (1/"/15mm reducer) K8.0/11,5 (S.I.), (3/4"/20mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (1 "/15mm reducer) K5.6/8,1 (S.I.), (3/4"/20mm reducer) K8.0/11,5 (S.I.) 2.0 CERTIFICATION/LISTINGS iv, O" VdS LPCB) 3.0 SPECIFICATIONS — MATERIAL III Series AH2 • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (1/2 or Ye): Carbon Steel, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated • • 10.85 5839 Rev X Updated 11/2015 ©2015 Victaulic Company.All rights reserved. , victaulic.com 4.0 DIMENSIONS • Product Details - Series AH2 Braided Hose Item Description O s © 1• .. Hexib.....e0 �0. 2... Isolation Rmq a:I ��V� � � � 3 „ �s�t ; 77- 'A Adapter Nipple_ 6 Braid 7 . . follar/We`d Fitting 8 Sleeve Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31/790° 125:25/641: 31/790 44; 36/915 31.25/794 36/915 48/1220 42125/1073 48/1220 _ 60/1525 54.25/1378 60/1525 72/1830 605/10, Standard Reducer .�IIIIIIIIHHUIIIIIIIIIIIAIIIII■rt • 5.75/140 mm straight reducer Optional Reducers 9.0/229 mm straight reducer III1111111111111111111111111111111111 1111111lul111uuul c uulIIIIIH1lmmuillll IIIIIIIIIIIIIII IIIIIIIIIII 13.0/330 mm straight reducer 2.62"/ 66.5mm 2.62"/ m " 66.5 mm - III' 6.57"/ 4.83"/ = 166.9 mm 122.7 mm — _ LJ I Mt IN=1 Short 90°elbow reducer Long 90°elbow reducer NOTE • The Short 90°elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. 10.85 5839 Rev X Updated 11/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 4.1 DIMENSIONS VicFlex Brackets • Style AB1 p • Suspended Ceilings .�fr • Hard-Lid Ceilings (FM Only) �/ Item Description r 24"/610 mm&48 dr4"/1220 mm qua5Oer* ; ,", e. Patented d Center Bracket , 3 3' _ d BieCket j'F ,- ' p *Both sizes FM/VdS/LPCB approved,cULus listed 0 i* .-; , Style AB2 ` • Suspended Ceilings ./ • Hard-Lid Ceilings il/� 0 O Item Description 1 *1/610, 0441*rim ,g8 re B.,r 2 Patent-Pending adjustable Center bracket r, 3 : u x E ,Brac #" t 'Both sizes FM/VdS/LPCB approved,cULus listed .- 1 \i el 9 Style AB3 ` • Surface Mount Applications `�/= • FM Approved f�'� 4-.. „►i �t 11--ce, S • 10.85 5839 Rev X Updated 11/2015 ©2015 Victaulic Company.All rights reserved. • 1 victaulic.com 4.2 DIMENSIONS • VicFlex Brackets Style AB4 • Hard-Lid Ceilings with Hat furring channel grid system ft) Item Description 1 24'i.61674./1226mnritia-tvit----a 2 _Patent-Pending acl:tistable Center bracket 3 „ E.0 Bradret for Hat Furring tftarii 'Both sizes FM/VdS approved,cULus listed Style AB7 • Suspended Ceilings 14 • Hard-Lid Ceilings Item Description i 24701VIROI 6izeitriii2OMM*11:1;a10a4 4; 2 Patented 1-Bee2°Center Bracket 0 „ *nd Brkket aI ;?.• :;&" 'Both sizes FM/VdS approved. Style AB7 Adjustable • Suspended Ceilings 10' • Hard-Lid Ceilings Item Description It;;;17 • , 1460icittivareiar* 2 Patented 1-Beer Center Bracket • EndSta d P'abl- 4, 'Both sizes FM/VdS approved. 0 • • • 10.85 5839 Rev X Updated 11/2015 ©2015 Victaulic Company.All rights reserved. D.I. THREADED FITTINGS STARYIPEPRODUCTS *_. LISTED LISTED APPROVED • For fire protection services request submittal GRS 1.3 Ductile iron threaded fittings are UL,ULC listed and factory mutual approved for 500 psi service.Ductile iron per ASTM A 536 grade 65-45-12.Dimensions conform to ANSI B16.3 6 class 150.Threads are NPT per ANSI/ASME B1.20.1. 8 NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore, Iover tightening can cause damage to pipe threads which may cause leakage.Ductile iron , " _ _ fittingd should be tightened theree turns beyond hand tight,but no more than four turns. DUCTILE IRON 90 DEG. ELBOW NOMINAL ITEM MAX. DIMENSIONS WBGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE '" .. 1 DB90033 500 1.50 1.50 0.62 1 1/4 DB90044 500 1.75 1.75 0.90 1 1/2 DB90055 500 1.94 1.94 1.20 2 DB90066 500 2.25 2.25 1.85 El, ., 13 ,-- ` t.r DUCTILE IRON 45 DEG. ELBOW NOMINAL ITEM MAX. DIMENSIONS WBGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE - a.. 1 DB45033 500 1.12 1.12 0.46 DUCTILE IRON RED.90 DEG. ELBOW 11/4 DB45044 500 1.29 1.29 0.73 1 1/2 DB45055 500 1.43 1.43 0.92 NOMINAL ITEM MAX. DIMENSIONS WEIGHT 2 DB45066 500 1.68 1.68 1.50 SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE ,P"'"1X1/2 DB90031 500 1.26 1.36 0.44 1 X3/4 DB90032 500 1.37 1.45 0.52 1 1/4X1/2 DB90041 500 1.34 1.53 0.64 1 1/4X3/4 DB90042 500 1.45 1.62 0.72 ---� 1 1/4X1 DB90043 500 1.58 1.67 0.75 1 1/2X1 DB90053 500 1.65 1.80 0.92 DUCTILE IRON STRAIGHT TEE 1 1/2X1 1/4 DB90054 500 1.82 1.88 1.08 NOMINAL ITEM MAX. DIMENSIONS WEIGHT 2X1/2 DB90061 500 1.49 1.88 1.08 SIZE CODE WORKING EACH 2X3/4 DB90062 500 1.60 1.97 1.24 2X1 DB90063 500 1.73 2.02 1.40 (INCH) # P.S.I. A B PIECE 2X1 1/4 DB90064 500 1.90 2.10 1.52 1 DT333 500 1.50 1.50 0.85 2X1 1/2 DB90065 500 2.02 2.16 1.65 11/4 DT444 500 1.75 1.75 1.22 1 1/2 DT555 500 1.94 1.94 1.55 1,1' ' -1 .4051‘ 2 DT666 500 2.25 2.25 2.45 A� r-i DUCTILE IRON COUPLING NOMINAL ITEM MAX. DIMENSION WBGHT DUCTILE IRON RED. COUPLING SIZE CODE WORKING EACH (INCH) # P.S.I. A PIECE NOMINAL ITEM MAX. DIMENSION WBG 1 DCL033 500 1.67 0.40 SIZE CODE WORKING EACH 11/4 DCL044 500 1.93 0.57 (INCH) # P.S.I. A PIECE 11/2 DCL055 500 2.15 0.75 1X1/2 DRC031 500 1.69 0.39 2 DCL066 500 2.53 1.15 1X3/4 DRC032 500 1.69 0.53 Page 21 i f D.I. THREADED FITTINGS ., STAR®PIPEPRODUCTS * V L 44* LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 c DUCTILE IRON REDUCING TEE NOMINAL ITEM MAX. DIMB4SIONS WBGHT ..._ SIZE CODE WORKING EACH (INCH) # P.S.I. A B C PIECE 1 X1 X1/2 DT331 500 1.26 1.26 1.36 0.64 A- P I 1 X1 X3/4 DT332 500 1.37 1.37 1.45 0.73 1X1/2X1 DT313 500 1.50 1.36 1.50 0.71 1X3/4X1 DT323 500 1.50 1.45 1.50 0.76 1 X1X1 1/4 DT334 500 1.67 1.67 1.58 0.98 1 X1 X1 1/2 DT335 500 1.80 1.80 1.65 1.16 1 1/4X1 X1/2 DT431 500 1.34 1.26 1.53 0.82 1 1/4X1 X3/4 DT432 500 1.45 1.37 1.62 0.90 -. r 1 1/4X1X1 DT433 500 1.58 1.50 1.67 1.00 1 1 1/4X1X1 1/4 DT434 500 1.75 1.67 1.75 1.08 1 - I P 6. 1 1/4X1X1 1/2 DT435 500 1.88 1.80 1.82 1.42 a E 4 7-- ( 1 1/4X1 1/4X1/2 DT441 500 1.34 1.34 1.53 0.86 r r. x . . a 1 1/4X1 1/4X3/4 DT442 500 1.45 1.45 1.62 0.92 " 7 y 1 1 1/4X1 1/4X1 DT443 500 1.58 1.58 1.67 0.95 1 1/4X1 1/4X1 1/2 DT445 500 1.88 1.88 1.82 1.45 OUTSIDE HEAD INSIDE HEAD 1 1/4X1 1/4X2 DT446 500 2.10 2.10 1.90 1.75 1 1/2X1 X1/2 DT531 500 1.41 1.34 1.66 0.95 DUCTILE IRON BUSHINGS 11/2X1X37 DT532 500 1.52 1.37 1.75 1.14 1 1/2X1 X1 DT533 500 1.65 1.50 1.80 1.17 NOMINAL ITEM DIMENSIONS 1 1/2X1X1 1/4 DT534 500 1.82 1.67 1.88 1.34 .IZE CODE WT. 1 1/2X1X1 1/2 DT535 500 1.94 1.80 1.94 1.45 A B C STYLE EACH 1 1/2X1 1/4X1/2 DT541 500 1.41 1.34 1.66 1.05 H) # 1 1/2X1 1/4X3/4 DT542 500 1.52 1.45 1.75 1.15 1x1/2 DBUSH31 0.75 0.25 1.42 OUT 022 1 1/2X1 1/4X1 DT543 500 1.65 1.58 1.80 1.25 1x3/4 DBUSH32 0.75 0.25 1.42 OUT 0.17 1 1/2X1 1/4X2 DT546 500 2.16 2.10 2.02 1.90 1 1/2X1 1/2X1/2 DT551 500 1.41 1.41 1.16 1.15 1 1/4x1 DBUSH43 0.80 0.28 1.76 OUT 0.28 1 1/2X1 1/2X3/4 DT552 500 1.52 1.52 1.75 1.24 1 1/2x1 DBUSH53 0.83 0.31 2.00 OUT 0.44 1 1/2X1 1/2X1 DT553 500 1.65 1.65 1.80 1.30 1 1/2x1 1/4 DBUSH54 0.83 0.31 2.00 OUT 0.30 1 1/2X1 1/2X1 1/4 DT554 500 1.82 1.82 1.88 1.48 2x1 DBUSH63 0.88 0.41 1.95 IN 0.66 1 1/2X1 1/2X2 DT556 500 2.16 2.16 2.02 1.98 2X1X2 DT636 500 2.25 2.02 2.25 2.15 2x1 1/4 DBUSH64 0.88 0.34 2.48 OUT 0.72 2X1 1/4X2 DT646 500 2.25 2.10 2.25 2.30 2x1 1/2 DBUSH65 0.88 0.34 2.48 OUT 0.61 2X1 1/2X1/2 DT651 500 1.49 1.41 1.88 1.50 2X1 1/2X3/4 DT652 500 1.60 1.52 1.97 1.62 2X1 1/2X1 DT653 500 1.73 1.65 2.02 1.64 2X1 1/2X1 1/4 DT654 500 1.90 1.82 2.10 1.80 2X1 1/2X1 1/2 DT655 500 2.02 1.94 2.16 2.00 2X1 1/2X2 DT656 500 2.25 2.16 2.25 2.35 e 2X2X1/2 DT661 500 1.49 1.49 1.88 1.60 2X2X3/4 DT662 500 1.60 1.60 1.97 1.68 0 2X2X1 DT663 500 1.73 1.73 2.02 1.85 2X2X1 1/4 DT664 500 1.90 1.90 2.10 2.04 2X2X1 1/2 DT665 500 2.02 2.02 2.16 2.18 2X2X2 1/2 DT667 500 2.60 2.60 2.39 3.61 I 0 2 1/2X2X3/4 DT762 500 1.74 1.60 2.32 2.28 " ..„ I DUCTILE IRON CROSS NOMINAL ITEM MAX. DIMB4SIONS WBGHT ;k • i I SIZE CODE WORKING EACH DUCTILE IRON CAP (INCH) # P.S.I A B PIECE 01 DX033 500 1.50 1.50 0.98 NOMINAL ITEM MAX: DIMENSION WBGHT 1 1/4 DX044 500 1.75 1.75 1.50 SIZE CODE WORKING EACH 11/2 DX055 500 1.94 1.94 1.90 (INCH) # P.S.I. A PIECE 2 DX066 500 2.25 2.25 2.95 1 DCP003 500 1.16 0.32 11/4X1 DX043 500 1.58 1.67 1.27 11/4 DCP004 500 1.28 0.43 1 1/2X1 DX053 500 1.65 1.80 1.48 11/2 DCP005 500 1.33 0.60 2X1 DX063 500 1.73 2.02 2.10 2 DCP006 500 1.45 0.91 Page 22 . _ FIG. MT-30 Threaded Mechanical Branch Tee (0)AMIN; . 0 , Iiii -... .-- ,-----,- as ir ---- -------r------ --- -- C ------ . ---4--- ----- Li) MT-30 THREADED MECHANICAL BRANCH TEE Hole Dimensions Max. Dimensions Nominal Approx. Size O.D. Working Min.Diameter Max.Diameter PressureA A B E TakeT -out Wt.Ea. 4000ind Winfir''': Vim :liAllm- -e.64ai , ift/thiii- ...1'?,- J4/mm „,,,,„,, kiii, ..,,,,,, ,, ,,,,,,,,,, ao, ., . 1¼x1/2 1.660 x 0.840 13A6 15/6 300 21/i 3% 21/4 1% 0.8 32 x 12 42.4 x 21.3 30 33 20.7 54 89 57.2 42 0.4 11/4 x% 1.660 x 1.050 13A6 15/16 300 2% 3% 21/4 15/8 0.8 32 x 19 42.4 x 26.7 30 33 20.7 54 89 57.2 42 0.4 1¼x 1 1.660 x 1.315 13A6 11/16 300 21/4 3% 21/4 1% 1.1 32x25 42.4 x 33.7 30 33 20.7 58 89 57.2 41 0.5 11/2 x% 1.900 x 0.840 13A6 15/16 300 21/4 3% 21/4 1% 0.8 40 x 12 48.3 x 21.3 30 33 201 57 89 57.2 48 0.4 • 11/2x3/4 1.900 x 1.050 13/16 15/16 300 21/4 31/2 21/4 1% 0.9 40 x 19 48.3 x 261 30 33 20.7 57 89 57.2 48 0.4 1½x1 1.900 x 1.315 Wm 15/16 300 2% 3% 21/4 1% 1.1 40 x25 48.3 x33.7 30 33 20.7 61 89 57.2 48 0.5 2 x 1/2 2.375 x 0.840 1A6 N6 300 2% 3% 21/4 2 0.9 50 x12 60.3 x 21.3 30 33 20.7 64 95 57.2 51 0.4 2 x% 2.375 x 1.050 13/11 15/6 300 2% 3% 21/4 2 0.9 50 x 19 60.3 x 26.7 30 33 20.7 64 95 57.2 51 0.4 2 x 1 2.375 x 1.315 13/16 15A6 300 25/s 3% 21/4 2 1.1 50 x 25 60.3 x 33.7 30 33 20.7 67 95 57.2 50 0.5 2%x% 2.875 x 0.840 13/16 15A6 300 2% 41/4 21/4 21/4 0.9 65 x 12 73.0 x 21.3 30 33 20.7 70 108 57.2 57 0.4 2%x% 2.875 x 1.050 13/16 15/16 300 2% 41/4 21/4 21/4 0.9 65 x19 73.0x26.7 30 33 20.7 70 108 57.2 57 0.4 2%x 1 2.875 x 1.315 13/16 15/16 300 2% 41/4 21/4 21/4 1.1 65 x 25 73.0 x 33.7 30 33 20.7 73 108 57.2 56 0.5 BSP equivalent is available as a MT-90. •-Working Pressure Ratings are for reference only and based on Sch.10 and Sch.40 pipe.For the latest UL/ULC,FM,VdS and A WARNING LPCB pressure ratings versus pipe schedule,please visit anvilintl.com or contact your local Anvil Representative. For dry pipe systems and freezer applications Note:Tighten nuts alternately to a recommended torque of 18-22 ft.-lbs.(25-30 Nm)on pipe wall less than schedule 10(Din 2440) lubrication of the gasket is required, or 23-27 ft.-lbs.(31-37 Nm)on pipe walls schedule 10(DIN 2440)and above. Gruvlole XtremeTM Lubricant is required. I FP-10.16 COSCO Fire Protection tare Protection and Lifc Safety Specialists • Pipe Hangers • COSCO Fire Protection Inc. S 2501 SE Columbia Way, Suite 100 Vancouver,WA 98661 Phone:360-883-6383 Fax: 360-883-6390 Toll Free:800-983-6383 479'.. rig 00 • P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 1(,-;:-: NFPA 13 UL // 7 WT. S IA/T.+250 TEST PIPE ROD LOAD ) ) 1 3/8 30.75 403.75 750 ( / / 11/4 3/8 43.95 469.75 750 11/2 3/6 54.15 520.75 750 2 3/8 76.95 634.75 750 2 1/2 3/8 118.35 841.75 850 4110 3 3/8 162.30 1061.50 1050 1 thru 4 inch pipe 1/2&3/4 inch pipe 4 3/8 246.00 1480 00 1500 LISTED FOR STEEL/CPVC 5 thru 8 inch pipe 5 1/2 349.45 1996.75 2000 6 1/2 476.35 2631.75 2650 8 1/2 711.00 3805.00 4050 SIZE-ROD-3/8"or 1/2" SIZE-SYSTEM PIPE- 1/2" thru 8" MATERIAL-Carbon Steel. FINISH-Mil.Galvanized to G-90 specification. LISTING/APPROVAL- `�� °s 203-EX 2551 1"-8" <N>Approval guide-1"-8" OSHPD OPA-0601 See Website. TED Conforms to Federal Specification WW-H-171E type 10,and :.• Manufacturers Standardization Society SP-69,type 10. MAXIMUM TEMPERATURE-650°F. FUNCTION-Pipe component of an AFCON hanger. To support horizontal steel,CPVC or copper pipe. INSTALLATION-Per these instructions including NFPA 13 and the CPVC manufacturers instructions. PIPE A B 1 1.8793 25259 FEATURES 11/4 2.1382 2.7850 * Sized and listed exclusively for use with#310 Surge Restrainer. T i 1 1/2 22673 2.9140 *Band edge is offset for EASY pipe insertion. B 2 2.6648 3.2516 '421/2 2.7500 3.5060 *Custom fit swivel nut for better retention in ring. 3 35625 3.8205 ill ORDERING-Part#,pipe size. i 4 35625 43205 5 40940 4.9397 6 4.6250 54707 8 75620 8.4077 n 9/15 SAMMYS DESCRIPTION/SUGGESTED SPECIFICATIONS Sammy s Revolutionizes The Pipe Sam m HandingTrades— The The Sammy X-Press®System is designed to provide direct attachment of threaded rod in metal deck X-Press° (22-16 gauge)and thin gauge purlin(18-16 gauge),while providing reduced installation costs in terms of time and materials. The X-Press Anchors eliminate the need for costly"armovers"in pipe hanging installations. Current methods offered for thin gauge purlin require use of a time-consuming retaining nut on the threaded portion of the fastener to prevent pullout Installs into ' ;` and are not designed for use in metal deck.In many instances, xx access to the backside of the installed fastener is prohibited Metal Deck, ;., by panel liner or roofing insulation. Sammy X-Press®anchors • deliver the performance installers require without the use of a '` retaining nut! Tubulars ee5ary Press The patent-pending X-Press Anchors consist of a threaded r" fastener and expandable sleeve. The X-Press System features an easy-to-install anchor with expanding anchoring strips that collapse to prevent pullout after installation. The Sammy X-Press®It Installation Tool assures a perfect installation every time offering the added convenience of one-tool efficiency—just drill and drive in seconds! SECONDS! i , ADVANTAGES • I i.:. Installs in seconds,saving time& jobsite material needed. installation costs. rs No retaining nut required. Use in applications where access to the back of the installed fastener is prohibited,ie.metal Provides design flexibility. .0111 roof deck,tubular steel,or vapor barrier fabric. • s nay's X--Press, Swivel and Sidewinder The Sammy X-Press expands to provide 1 direct vertical attachment in: (XP) Metal Deck(22-16 gauge) Patent No. 6,935,821 - + -Z-Purlin(18-16 gauge) The Sammy X-Press Swivel allows you to I. hang plumb in extreme roof pitches: T 9 (SWXP) ' -89°in Z-Purlin Patent Pending -45°in metal deck for 12/12 pitch FOR The Sammy X-Press Sidewinder expands (SXP) 1ti EcTEE��E to provide horizontal attachment in: OR Patent Pending i V MI kV" -16 ga-3/16"steel-purlin,tubular steel. ROOF MOMS • d/TW Construction Products S.12 z SA I'SCall our toll free number 800-387-9692 or visit www.itwconstruction.cgfor general information. ''` Visit lTW Buildex's SAMMYS web site www.sammysuperscrew.com for the most current product and technical information. -Sammy Xpress 'ELECTION CHART SAMMYS X-Press Vertical Mount ROD PART ULTIMATE TEST • TEST MIN MAX BOX CASE SIZE NUMBER MODEL DESCRIPTION PULLOUT irk LOAD ® LOAD THICK THICK QTY QTY APPLICATION (LBS) LISTED (LBS) APPROVED (LBS) 1146 185(Luminaire) .027" n 1/4" 8181922 XP 200 X-Press 200 .125" 25 125 Metal Deck (XP) s (22 ga) 250(Luminaire) .056" 850(21/2"Pipe) Patent No. 1146 185(Luminaire) 940(2"Pipe) 027" 6,935,821 3/8" 8150922 XP 20 X-Press 20 (22 ga) 250(Luminaire) 1475(4"Pipe) .027" .125" 25 125 Metal Deck 283(Conduit&Cable) .056" 1250(3t/2"Pipe) .060" 3/8" 8153922 XP 35 X Press 35 1783 85(Luminaire) 940 (2"Pipe) .105" (16 ga) 250(Luminaire) 1475(4"Pipe) .027 125" 25 125 Purlin 416(Conduit&Cable) .056" Metal Deck 3/8" 8150922 XP 20 Sammy 1146(22 ga) 850(2th Pipe) Pre Pour Structural Concrete@ 3000 psi 25 125 (Pre-Pour) X-Press 20 Past Pour Range II LWC<_35 PCF(lbs/ft) Metal Deck (Post-Pour) Pre-Pour Structural Concrete @ 3000 psi Post-Pour Range II LWC<_35 PCF(lbs/fP) zt}rf' `r!i?.. �—�J V t }� hyerz4 . �L rr,9..;f: 4: a SAMMYS X-Press Swivel Head° ROD PART ULTIMATE TEST TEST MIN MAX BOX CASE SIZE NUMBER MODEL DESCRIPTION PULLOUT cus LOAD ® LOAD THICK THICK QTY QTY APPLICATION (LBS) LISTED (LBS) APPROVED (LBS) 750(2"Pipe) (SXP) 170 vertical(Luminaire) FOR Swivel 1061(22 ga Vertical) 80 @ 45°(Luminaire) Patent Pending �x'� EME. 3/8" 8294922 SXP 20 X-Press 20 829(45°Off Vertical) 283 vertical 635(2"Pipe) .027" .125" 25 125 Metal Deck \I Mata OR (Conduit&Cable) ROOF MIMS 233 @ 45° (Conduit&Cable) 1500(4"Pipe) 250 vertical(Luminaire) Swivel 1675(16 ga Vertical) 80 @ 90°(Luminaire) 3/8" 8295922 5XP35 500 vertical .060" .125" 25 125 Purlin X-Press 35 1558(89°Off Vertical) (Conduit&Cable) 635(2"Pipe) 333 @ 89° (Conduit&Cable) 1/2" 8272957 SXP 2.0 Swivel 1061(22 ga Vertical) X-Press 2.0 829(45°Off Vertical) .027" 125" 25 125 Metal Deck 1/2" 8271957 SXP 3.5 Swivel 1675(16 ga Vertical) X-Press 3.5 1558(89°Off Vertical) .060" 125" 25 125 Purlin SAMMYS X-Press Horizontal Mount ( ROD PART ULTIMATE ® TEST ® TEST MIN MAX BOX CASE SIZE NUMBER MODEL DESCRIPTION PULLOUT c us LOAD LOAD THICK THICK QTY QTY APPLICATION (LBS) LISTED (LBS) APPROVED (LBS) Sidewinder 1250(3Y:"Pipe) 3/8" 8293957 SWXP 35 X Press 35 1798(16 ga) 80(Luminaire) .060" .125" 25 125 Purlin 'stent Pending 416(Conduit&Cable) (SWXP) 117TH Construction Products S.�4 -s IVIMYS call our toll free number 000-387-9692 or visit www.itwconstruct on.ca for general information. ` rr VisitnWBuildex'sSAMMYSwebsitewww.sammvsunerstrew.comforthemostcurrentproductandtechnicalinformation. SAMMYS X-Press for Seismic Restraint ‘_Swveisto DESCRIPTION 45°to ensure BENEFITS proper FEATURES installation! ® Structural attachment and n Reduced installation cost. restraint component combined; n Design flexibility. t---- ready for selected rod. Less on site material(GO GREEN). �' " Access to the back of fastener • , Less material coordination. ■,i,�� • - � _ not required. ■ Aesthetically pleasing. ■ ■ Does not require use of a 4Alik Corz-Puriin i441Metal Deck �� • k retaining nut. T HID T 10 ED1 � N Quick and easy installation. T Eq RE!UIREmEN S • WI sow ots" FOR 3/8" AND 1/2" RODS SPECIFICATIONS • sca``'tE CATE80St SXP 20 AND SXP 35 FOR 3/8"ROD FOR 3/8"ROD AND 1/2"ROD Structural attachment for installation of branch/end of line restraint using Restrained Pipe Size: Up to Schedule 40 pipe 2"or less 3/8"all thread(.299"OD)or end thread rod(.374"OD). Max Length of SXP 20 for 3/8"Rod:Designed for use in metal deck ranging from 22 ga. Restraint Material: See Maximum Horizontal Load Tables below. through 18 ga.in low slope or pitched roof designs(12/12). Maximum Angle: 45°from horizontal SXP 35 for 3/8"Rod:Designed for use in steel purlin ranging from 16 ga. Material: Carbon Steel through 1/8"in low slope or pitched roof designs(12/12). The Swivels may be used to attach short length of rod to eliminate lateral Screw Description: 1/4"-20 x 1-1/8"with expandable sleeve sway bracing per NFPA 13,9.3.5.3.8,(2007). Finish: Electro-Zinc SXP 2.0 AND SXP 3.5 FOR 1/2"ROD Testing: Tested to GR-63-CORE Standard for performance in for of of line restraint using structural steel in seismic restraint applications as outlined for use in NFPA 13(� 1/2"all Structural attachment for installation end thread branch/endoa(.500"OD). 9.3 at an independent test lab.The calculated force used for the testing was equ thread(.405" that found in a Zone 4 and an 8.4 Richter scale seismic event. SXP 2.0 for 1/2"Rod:Designed for use in metal deck ranging from 22 ga. Listing for 3/8"Rod: UL 203 listed as pipe hanger File EX 5098 FM through 18 ga.in low slope or pitched roof designs(12/12). -SXP 20(22 ga.)0-45°from horizontal-2"Schedule 40 pipe ' SXP 3.5 for 1/2"Rod:Designed for use in steel purlin ranging from 16 ga. -SXP 35(16 ga.)0-90°from horizontal-3-1/2"Schedule 40 pipe O• T. through 1/8"in low slope or pitched roof designs(12/12). UL 203A File EX 15565 IDus s The Swivels may be used to attach short length of rod to eliminate lateralceil F sway bracing per NFPA 13,9.3.5.3.8,(2007). Listing for 1/2"Rod: UL 203A File EX 15565 �"5 SELECTION CHART SAMMYS X-Press Swivels - Seismic Restraint ROD PART MODEL MIN MAX APPLICATION BOX CASE INSTALLATION TOOL SIZE NUMBER THICKNESS THICKNESS QTY QTY 3/8" 8294922 SXP 20 22 ga 18 ga. Metal Deck 25 125 1/2" 8272957 SXP 2.0 22 ga 18 ga. Metal Deck 25 125 The SWXP 35 must be installed with UXPIT Tool(Part No. 3/8" 8295922 SXP 35 16 ga 1/8" Purlin 25 125 8194910);pre-drilling required. 1/2" 8271957 SXP 3.5 16 ga 1/8" Purlin 25 125 PERFORMANCE TABLES Maximum Rod Length for I/r=100, 200, 300, and 400 Least Radius of Maximum Rod Length for lir(ft) Restraint Shape and Size Nominal Diameter Area(in 2) Gyration,r(in.) 1/r=100 Ur=200 lir=300 lir=400* 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 Rods(all thread) 1/2 in. 0.129 0.101 0.8 1.7 25 3. 3/8 in. 0.11 0.094 0.8 1.6 2.4 3. Rods(threaded at ends only) 1/2 in. 0.196 0.125 1.0 2.1 3.1 4.2 Reference:NFPA 13,(2007) *Reference:NFPA 13,(2010) Construction Products Call our toll free number 800-387-9692 or visit www.itwconstruction.ca for general information. x 1 '; Visit ITW Buildeo's SAMMYS web site www.sammrsucenaew.com for the most current product and technical information. - Jf ress for Seismic Restraint rESTEe T� DESCRIPTION (SIDEWINDER) ITER.. OZONE 4u P 35 FOR 3/8"ROD 4(:) F7Eg7ED TO Structural attachment for installation of branch/end of line restraint using '• Se A/ sow DEQ 3/8"threaded rod.Used primarily in purlin,bar joist,or other steel structural CAtE80RtE$ members.These fastening systems provide a secure and economical attachment C.D.E. to F to the structure. The SWXP 35 model provides upper structural attachment in a range of steel thicknesses,from 16 ga.through 1/8".An expandable sleeve is included with 11 each fastener,eliminating need for retaining nut. " y _. SPECIFICATIONS . , � Restrained Pipe Size: Up to Schedule 40 pipe 2"or less Max Length of Restraint Material: See Maximum Horizontal Load Tables below. -rV Maximum Angle: 45°from horizontal / Material: Carbon SteelWltUeiSi[0 I )1 % J Screw Description: 1/4"-20 X 1-1/8"with expandable sleeve 45°to ensure Finish: Electro Zinc(cap&screw) Proper installation! Testing: BX Report#R-1362 Listing: UL 203 as a pipe hanger 41110 UL 203A pending LISTED s SELECTION CHART rt SAMMYS Sidewinders for Concrete - Seismic Restraint ROD PART MODEL MIN MAX BOX CASE SIZE NUMBER THICKNESS THICKNESS APPLICATION QTY Q� INSTALLATION TOOL The SWXP 35 must be in 3/8" 8293957 SWXP 35 16 ga. 1/8" Steel Purimor Bar Joist 25 125 with UX IT Tool(Part No58119 910); pre-drilling required. PERFORMANCE'TABLES Maximum Horizontal Loads for Restraint with 1/r=100, 200, 300, and 400 Restraint Shape and Size Nominal Diameter Area(in.') Least Radius of Maximum Rod Length for lir(ft) Gyration,r(in.) lir=100 lir=200 lir=300 lir=400* Rods(all thread) 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 1/2 in. 0.129 0.101 0.8 1.7 2.5 3.4 s(threaded at ends only) 3/8 in. 0.11 0.094 0.8 1.6 2.4 3.1 1/2 in. 0.196 0.125 1.0 2.1 3.1 4.2 Reference:NFPA 13,(2007) *Reference:NFPA 13,(2010) //T[r 7 Construction Products S 16 SA� YS. Call our toll free number 800-387-9692 or visit www.itwconstruction.cafor general information . Visit 11W Buildea i SAMMYS web site www.sammysupersaew.com for the most current product and technical information.