Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (19)
1 �'" R E� SUBMITTAL DATA: MXZ•�C20NA2 MITSUBISHI 1.5-TON MULTI-ZONE INVERTER HEAT-PUMP SYSTEM Aril,ELECTRIC Job Name: System Reference: Date: o `mow mak..,,\C;14 i% - .N::::::-,'Ir- 1itlCITY OFAF1 1 BUILDING GENERAL FEATURES • Variable speed INVERTER-driven compressor • Energy Star®certified (non-ducted) • M-NET connection through outdoor unit • Quiet outdoor unit operation as low as 50 dB(A) • New Intelligent Power Module (IPM)for reduced power loss • Selectable thermal lockout/restart function • Optional base pan heater • High pressure switch for additional protection • Thermal differential of+/-1° F from setpoint Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US, Inc. SPECIFICATIONS::: MXZ-2C20NA2 Outdoor unit M -2C ONA2 Model number Indoor unit type Nun- Mix Ducted Ducted Maximum Capacity ' Btu/h ' 20,000 Rated Capacity Btu/h 18 000 19,000 20 000 , Minimum Capacity Btu/h 5,700 1 Cooling*1 Maximum Power Input W 2,245 Rated Power Input W 1,417 1,709 2,000 Power Factor % 98.7 99.3 99.9 Maximum Capacity Btu/h 25,000 Rated Capacity Btu/h 22,000 I _ _ Minimum Capacity Btu/h 7,400 Heating at 47° F*2 Maximum Power Input W 2,455 Rated Power Input W 1,641 1,706 1,771 Power Factor % 96.2 97.9 99.6 Maximum Capacity Btu/h 15,500 15,000 14,500 Rated Capacity Btu/h 12,500 13,000 13,500 Heating at 17° F *3 P Maximum Power Input W p 1,750 1,780 1,810 Rated Power Input W ' 1,300 1,325 1,350 Maximum Capacity Btu/h 11,100 11,000 10,900 Heating at 5° F *4 j Maximum Power Input I W 1,600 1,625 1,650 SEER 20.00 18.00 16.00 EER *1 12.70 11.35 10.00 i HSPF (IV) j 10.00 9.65 9.30 Efficiency COP at 47° F *2 3.93 3.78 3.64 COP at 17° F*3 2.82 2.87 2.93 1 ENERGY STAR®Certified YES NO NO Voltage, Phase, Frequency 208/230V, 1-phase, 60 Hz ElectricalL................................................_..........._....._..............................................._.._..................................... Guaranteed Voltage Range V AC 187-253 Voltage: Indoor-Outdoor, S1-S2 VAC 208V/230 Voltage: Indoor-Outdoor, S2-S3 V DC 12-24 Voltage: Indoor- Remote controller ; V DC j 24 Recommended Fuse/Breaker Size A 20 Recommended Wire Size AWG AWG14 (Indoor-Outdoor) ; Outdoor unit MCA A . 17.2 Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US, Inc. SPECIFICATIONS: X,Z-2C20NA2 Outdoor unit 1{ XZ 2Q ONA2 model number indoor unit type Non- Mix Ducted Ducted Fan Motor Full Load Amperage i A 1.77 1 Fan Motor Output W 64 i Airflow Rate CFM 1,342/ 1,458 Refrigerant Control Liner Expansion Valve ' Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling*1 dB(A) 50 iSound Pressure Level, Heating*2 dB(A) 54 Compressor Type Twin Rotary type Compressor Model SNB140FQUH2T Compressor Motor Output kW 1 1.5 Compressor Rated Load Amps A 10.7 Compressor Locked Rotor Amps A 15.5 'Compressor Oil Type//Charge , oz. NE022 /20.3 i ' External Finish Color Munsell 3.0Y 7.8/1.1 Base Pan Heater Optional W: In. [mm] 33-1/16 [840] Unit Dimensions D: In. [mm] 13 [330] H: In. [mm] 27-15/16 [710] W: In. [mm] 40[1,010] Package Dimensions D: In. [mm] 18-1/2 [470] H: In. [mm] 33-1/2 [850] 1 Unit Weight Lbs.[kg] 126 [57] Package Weight Lbs.[kg] 147 [67] Cooling Intake Air Temp °F 14 to 115 (Maximum/Minimum) Outdoor unit operating ......................................_................................................................................ .............................................._............................................................................................................................................................................... p g Heating Intake Air Temp °F 5 to 75 temperature range ' (Maximum/Minimum) Thermal Lock-out/ Re-start Temperatures °F Cooling: 10.4/ 14 Heating: 1.5/5 Type R410A Refrigerant 'Charge , Lbs., Oz. 3, 15 Maximum Number of Connected IDU 2 Indoor unit connection Minimum Number of Connected IDU 2 Maximum connected capacity Btu/h 24,000 Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US, Inc. SPECIFICATIONS. MXZ-2C24NA2 Outdoor unit MXZ-2C20NA2 Model number indoor unit type Non- Mix Ducted Ducted Minimum connected capacity Btu/h 12,000 Gas Pipe Size O.D. (Flared) 1 In.[mm] j 3/8 [9.52] Liquid Pipe Size O.D. (Flared) In.[mm] 1/4 [6.35] Total Piping Length Ft. [m] 164 [50] Maximum Height Difference, Ft. [m] 33 [10] Piping ODU above IDU Maximum Height Difference, Ft. [m] 49 [15] ODU below IDU Farthest Piping Length from ODU to IDU Ft. [m] 82 [25] Maximum Number of Bends 50 AHRI Rated *1 Cooling (Indoor//Outdoor) °F 80°F DB, 67°F WB//95°F DB, 75°F WB Conditions (Rated *2 Heating at 47°F (Indoor//Outdoor) °F 70°F DB, 60°F WB//47°F DB 43°F WB data is determined � 1 at a fixed �*3 Heating at 17°F (Indoor//Outdoor) °F 70°F DB, 60°F WB// 17°F DB, 15°F WB compressor speed) Conditions !*4 Heating at 5°F (Indoor//Outdoor) °F 70°F DB, 60°F WB//-4°F DB, -5°F WB For reference to connected capacity charts, please refer MXZ-2C20NA2-U1 Operational Performance. Notes: Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US, Inc. ACCESSORIES: 'MXZ-2C20NA2 1 Unit p9.52 —> PipeT15.88 o PAC-SG76RJ-E Unit p6.35 —> Pipecp9.52 ❑ PAC-493PI Joint Pipe j Unit p9.52 —> Pipe912.7 o MAC-A454JP-E Unit cp12.7 —> Pipecp9.52 o MAC-A455JP-E Unit 912.7 —> Pipecp15.88 o MAC-A456JP-E - Air Discharge Guide o MAC-856SG Base Pan Heater o PAC-646BH-E Control Cable ❑ CW162S 3-pole Disconnect ❑ TAZ-MS303 M-NET Adapter o PAC-IFO1 MNT-E . ........................................................................................................................_.............................................................. 1 Wall Mounting Bracket(Powder-coated Steel) ❑ QSWB2000M-1 Wall Mounting Bracket(316 Series Stainless Steel) o QSWBSS Outdoor Unit Mounting Pad 24"x 42"x 3" ' o ULTRILITE2 - I MiniSplit Mounting Stand-Dual Fan models- 12" ❑ QSMS1202M MiniSplit Mounting Stand-Dual Fan models- 18" o QSMS1802M MiniSplit Mounting Stand-Dual Fan models-24" o QSMS2402M 1/4 x 1/2 x 15'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T-15 1/4 x 1/2 x 30'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T-30 1/4 x 1/2 x 50'/ 1/2" Lineset(Twin-Tube Insulation) , o MLS141212T 50 1/4 x 1/2 x 65'/ 1/2" Lineset(Twin-Tube Insulation) j ❑ MLS141212T-65 1/4 x 1/2 x 100'/ 1/2" Lineset(Twin-Tube Insulation) o MLS141212T-100 Diamondback Diamond 3/8 x 5/8 x 10'/ 1/2" Lineset(Twin-Tube Insulation) o MPLS385812T-10 L .........._.................................__........................................._......._....._.__......_....................................._.._.._.._........._._._._.............................._..._......................_....................................................................................._......_............_......................._............_._.................................................... 3/8 x 5/8 x 15'/ 1/2" Lineset(Twin-Tube Insulation) I ❑ MPLS385812T-15 3/8 x 5/8 x 30'/ 1/2" Lineset(Twin-Tube Insulation) o MPLS385812T-30 3/8 x 5/8 x 50'/ 1/2" Lineset(Twin-Tube Insulation) o MPLS385812T-50 3/8 x 5/8 x 65'/ 1/2" Lineset(Twin-Tube Insulation) o MPLS385812T-65 3/8 x 5/8 x 100'/ 1/2" Lineset(Twin-Tube Insulation) o MPLS385812T-100 Linesets are indoor unit specific and will be listed in the IDU information-the Joint Pipe adaptors are used in this application Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US, Inc. DIMENSIONS: MXZ-2C20NA2 Unit: inch (mm) 6-21/32" 19-11/16" 6-23/32" 2-9/16 w I Air rn Inlet iIC Q M � � IM z; l , \ . AirInleta M 1" 3-e(1-5/161 Drain hole b Outlet Zo 4(13/32".13/16")Oval Hole (Foundation Bolt M8) Handle - 33-1/16" 1-3/16" 7.7/8" 1-1/32" 13" 1/2" fl III C IEEE. o0o I'11i11011101111011.� �I,�l 2-19/32" 00 111111111111' 'I �Ii Ih� 1► ������ oo 1f 11111lllu� d IIIIII ma II VIII �� A , ,—. • i • 1 ,■■■■ oo I IIIIIIIIIIII uu tllllllllllllllllllll IIIIIIIII I 1111 ,II, �1 111.1l1,i " _ 1I gill n IIIIIIIII 1011101 1. 11 • , •�� OO O IIIIIIIIIII II IIII11111 r! GIAS�Un0A. ...N. ■■.■ `{o (Il11110 ,i,llll VIIIIIID : Llp ...r.,,,,,,,„ �_f_ GAS Un ,Ls 1 29/32" 11-25/32" 1.FREE SPACE li . r E E 3-15/16• or mare 3-15/16' or more 13 25/32' or more 2.SERVICE SPACE E kii,„w,, -r/m 1 Grounding terminal %AWE - II`:-� 000000 3-15/16" or more f' / - rj� /mv°r SERVICE SPACE iI I13-25/32" iJ _ -- Lock nut Connector MtaMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee,GA 30024 Toll Free: 800-433-4822 www.mehvac.com AMEN CERTIFIED-' c (II; us M R1Star0.2 cnrev FORM#MXZ-2C2ONA2-201706 n toa� Intertek Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US, Inc. ■ , „ - - MI SU61 � ERIES 12,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS M'% ELECTRIC ib Name: /stem Reference: Date: _ l SPECIFICATIONS: Rated Capacity" Cooling' Btu/h/W 12,000 Heating at 47°F2 Btu/h/W 14,400 ` Rating Conditions perAHRI Standard: Indoor •Unit:MSZ-GL12NA-U1 i"'.. 'Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB;Outdoor:95°F(35°C)DB/75°F(24°C)WB I Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB;Outdoor:47°F(8°C)DB/43°F(6°C)WB For data on specific indoor units(all ducted,all non-ducted,and both ducted and non-ducted) combinations,see the MXZ Technical and Service Manual. Wireless Remote Controller Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. Electrical Power 208/230V, 1-Phase,60 Hz CESSORIES: Requirements oor Unit Condensate Pump(BlueDiamond X87-711/721; 115/230V) Minimum Circuit A Ampacity(MCA) 1 Condensate Pump(Sauermann S130-115/230; 115/230V) Anti-Allergy Enzyme Filter(MAC-408FT-E) Platinum Catalyst Deodorizing Filter(MAC-308FT-E) Blower Motor(ECM) F.L.A. 0.76 Drain Pan Level Sensor(DPLS2) Blower.Motor Output W 30 ntrols Wireless Controller(MHK1) Field Drainpipe Size O,D, In.(mm) 5/8(15) Wired Remote Controller PAR-32MAA(Requires MAC-3331F-E) Wireless Interface for kumo cloud TM(PAC-WHSO1WF-E) Airflow Rate(Quiet-Lo-Med-Hi-Super Hi) Thermostat Interface(PAC-US444CN-1) DRY 145-170-237-321-399 Cooling WET CFM 109-134-201-286-364 Heating DRY 145-170-237-321-406 Sound Pressure Level(Quiet-Lo Med-Hi-Super Hi) Cooling 19-22-30-37-45 dB(A) Heating 19-22-30-37-43 External Dimensions 11-5/8 x 31-7/16 x 9-1/8 (H x W x D) In.(mm) (295 x 798 x 232) Net Weight Lbs.(kg) 22 (10) External Finish Munsell 1.0Y 9.2/0.2 Refrigerant Piping(Flared) Liquid(High Pressure) 1/4(6.35) In.(mm) Gas(Low Pressure) 3/8(9.52) • Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. • DIMENSIONS: MSZ-GLI2NA-U MSZ-GLI2NA-U1 Unit:in.(mm) 1/16x1 Oblon. hole 1/16x13/16 Oblon. hole Installation plate 3-I/81 _ 8-1/8 8-1/8 ■ 3-1/8 'I !r�C 31-1/16 k 30-15/16 ,1_1/4 000 aO — -- 0:. ‘,..0 a.") .. I'--MI—--Ell II'___!!__ ■■II a0 6-I/8 6-I/8 00 ' --------"- - 2-3/8 13-5/16 13-9/16 2-1/8 9-1/8 3/16 Indoor unit Air in all hole #2-9/I6 4 —� .. _/ IF!'_ " Installation date ,i.___,.. 3/4 1-15/16L 24-3/8 ...F.5I/8,1 <'� _ 1 1-5/8 M 4-3/I6, . Drain hose 0 111171 2-5/161 r tri/4 — I •I - 0oa Air ann l I Insulation 01-3/8 O.D ' H _ MI a Liquid line 01/4 19-11/16(Flared connection 01/4) I 'a Gas line 03/8 16-15/16 2-3/16 I- 5/ 6 I I (Flared connection:03/6(GL06109112NA),01/2(GL15NA)) 'I "'III I-3/ 6 Drain hose Insulation 01-1/8 O.D Connected part 05/8 O.D at. MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ru !CERTIFIED..IUMI ` c Ej/ us am,FORM#MSZ-GL12NA-U1 FOR MXZ-C MULTI-ZONE SYSTEMS-201611 IIlt1'rtelC .Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. i r - - - ^ ' [.it ! , - IvMITSUBIS "SERIES 9,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT PUMP SYSTEMS I1 ELECTRIC ib Name: /stem Reference: Date: SPECIFICATIONS: Rated Capacity* Cooling' Btu/h/W 9,000 Heating at 47°F2 Btu/h/W 10,900 Rating Conditions per AHRI Standard: Indoor Unit:MSZ-GL09NA-U1 $vv° 'Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB;Outdoor:95°F(35°C)DB/75°F(24°C)WB 2 Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB;Outdoor:47°F(8°C)DB/43°F(6°C)WB For data on specific indoor units(all ducted,all non-ducted,and both ducted and non-ducted) combinations,see the MXZ Technical and Service Manual. Wireless Remote Controller Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. Electrical Power 208/230V, 1-Phase, 60 Hz :CESSORIES: Requirements oor Unit Minimum Circuit A 1.0 Condensate Pump(BlueDiamond X87-711/721; 115/230V) Ampacity(MCA) Condensate Pump(Sauermann SI30-115/230; 115/230V) Anti-Allergy Enzyme Filter(MAC-408FT E) Platinum Catalyst Deodorizing Filter(MAC-308FT-E) Blower Motor(ECM) F.L.A. 0.76 Drain Pan Level Sensor(DPLS2) Blower Motor Output w 30 ntrols Wireless Controller(MHK1) Field Drainpipe Size Q.D, In.(mm) 5/8(15) Wired Remote Controller PAR-32MAA(Requires MAC-3331F-E) Wireless Interface for kumo cloudTM(PAC-USWHS002-WF-1) Airflow Rate(Quiet-Lo-Med-Hi-Super Hi) Thermostat Interface(PAC-US444CN-1) DRY 145-170-237-321-399 Cooling WETCFM 109-134-201-286-364 Heating DRY 145-170-237-321-406 Sound Pressure Level(Quiet-Lo-Med-Hi-Super Hi) Cooling 19-22-30-37-43 d8(A) Heating 19-22-30-37-43 External Dimensions 11-5/8 x 31-7/16 x 9-1/8 (H x W x D) In.(mm) (295 x 798 x 232) Net Weight Lbs.(kg) 29(12) External Finish Munsell 1.0Y 9.2/0.2 Refrigerant Piping(Flared) Liquid(High Pressure) 1/4(6.35) In.(mm) Gas(Low Pressure) 3/8(9.52) Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: MSZ-GLO9NA-U1 MSZ-GLO9NA-U1 Unit:in.(mm) 111601 Oblon. hole 1/16x13/16 Oblon, hole Installation plate 3-I/8.1 8-7/8 8-7/8 /8 31-1/16 30 15/16 E/4 000 ao ld ` i0, I\ISM=„= M =imil �t T 6-1/86-1/8 . 1 ..,-2tr N 2 3/8 3 5/16 13-9/16 2 1/8 9-1/8 3/16 Indoorunit Air in oll hole #2-9/16 ” "= —" Installation late i' :co Pi in :Z. ,_. .....,0 , ..._. I 4 . I i 1111' �r `-Il „, .” _ _ `-- 111! / 1-5/8 1-3/4 I-15/16_ 24-3/8 _,5-I/8,� � . 4-3/16x, Drain hose 2-5/161 Ir ; Air out 22 Z t Insulation al-3/8 O.D a Liquid line 01/4 19-11/16(Flared connection 01/4) oGas line 03/8 16-15/16 2-3/16 1-15/16 I (Flared connection:03/8(GL06109112NA),01/2(GL15NA)) III"` I 3/16 Drain hose Insulation 01-1/8 O.D Connected part 05/8 O.D • a* MITSUBISHI M, ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 fli9Liti CERTIFIED,. ceus FORM#MSZ-GLO9NA-U1 FOR MXZ-C MULTI-ZONE SYSTEMS-201611 .. «,, n>A,,r, Intertek Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MITSUBISHI ELECTRIC flurLIl1ifl® C OOLING & HEATING Split-ductless A/C and Heat Pumps SUBMITTAL DATA: MHK1 REMOTE CONTROLLER KIT FOR M-SERIES AND P-SERIES Job Name: Location: Date: Purchaser: Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction System Designation: Schedule No.: MHK1 REMOTE CONTROLLER KIT INCLUDES: MRCH1 REMOTE CONTROLLER • Diagnostics: Displays and records error codes • For use with P-Series NHA4 • No addressing required systems,SEone-to- • Can be integrated with other RedLINKTM devices one systems,SLZ/SUZ �� ., one-to-one systems,MXZ-B • Wiring:Connects using five-conductor cable from MIFH1 Wireless Receiver(cable included)to indoor unit;wireless RF multi-zone systems,MSY/MSZ, `� from the MIFH1 Wireless Receiveto the MRCH1 Remote and MFZ indoor units � ' • Backlit,easy-to-read display , Controller • Supports both Fahrenheit and Dimensions:3-9/16"H x 5-13/16"W x 1-1/2"D(147 x 38 x Celsius 91mm) • User functions allow user to set: • Uses two"AA"alkaline batteries(included) -On/Off -Operation modes cool,heat,drying,fan -Set temperature(separate dual set points for heat and cool) MIFH1 WIRELESS RECEIVER , -Fan speed setting • Mounts next to or near indoor units -Airflow direction to allow MRCH1 Remote P � ' • Day/Filter me display with a 12-hour clock Controller operation of P-Series • Optimal s display NHA4 systems,SEZ-4/SUZ one- • start to-one s stems,SLZ/SUZ one-to- • Adjustable auto deadband one systems,MXZ-B multi-zone ., • Space temperature offset adjustment Y • Display outside temperature and humidity(requires optional systems,MSY/MSZ,and MFZ indoor MOS1,sold separately) units • Hold function • Dimensions:6-7/16"H x 3-1/4"W x 1-5/16" • Temporary schedule override D(164 x 82.5 x 34 mm) • Reset to factory default • Auto lock display MRC1 CABLE • Timer Operation: •Connects MIFH1 Wireless Receiver to five- -Daily Timer:On/Off times can be set up to 4 times per day in pin CN105 on indoor unit control board 15-minute increments. -Weekly Timer:On/Off times can be set up to 4 times per day of •Five-conductor wire with preterminated ends the week in 15-minute increments.Choice of 5-2 and 5-1-1 •Length:6-1/2'(2 m) weekly schedules for heat,cool,auto(separate for each mode) -Auto-off Timer:Turns indoor unit Off at scheduled time up to OPTIONAL ACCESSORIES 24 hours in advance • Room Temperature:Displays room temperature sensed either at o Portable Central Controller(MCCH1;for use with Wireless Remote the indoor unit or at the remote controller(default) Controller Kit MHK1)* • Set temperature range limits(dependent on the system connected): o Outdoor Air Sensor(MOS1;for use with Wireless Remote Cooling from 50°to 99°F Controller Kit MHK1)* Heating from 40°to 90°F Auto from 50°to 90°F with dual temperature setting *See Submittal for information on each option. MIFH1 Wireless receiver r - MOS1 MRCH1" •, ., Outside Remote controller = /' — Air Sensor � L (Optional) ,, *' 7, ' i ' MCCH1 Portable isv ._, 4 central ' controller Mr.51im Outdoor Unit MITSUBISHI 3400 Lawrenceville Suwanee Rd FORM#MHK1- 201108 AffkUk ELECTRIC Suwanee,GA 30024 ., Toll Frree:ee:800-433--482.; RedLINK is a trademark of Honeywell,Inc. Tele: 800-433 •Fax:2800-889-9904 2(#3) PARTNER ©2011 MITSUBISHI ELECTRIC&ELECTRONICS,INC. C O O L I N G & H E A T I N G www.mehvac.com -.. L i v o Bettor Specifications are subject to change without notice.