1 33 ��F ZX �w P-SERIES SUBMITTAL DATA: PKA-A18HA7 & PUZ-A18NKA7(-BS) MITSUBISHI 18,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM /_ELECTRIC Job Name: System Reference: FIECENED Indoor Unit: Outdoor Unit: APR 3 0 2018 PKA-A18HA7 o PUZ-A18NKA7 CITY OF TICARD ❑ PUZ-A18NKA7-BS BUILDINGyISIQN - 04, J 4 �.,, 4. ' ria r„.c; « ;Ya:, 8 ✓'t.da:' k�F6 a:'x "1 �, ...,, k' H r y u a ' ✓�' ✓9 INDOOR UNIT FEATURES • Sleek, compact design • Simple installation • Vane setting for air flow direction control • Auto fan speed mode • Ideal for spaces such as server rooms, daycare centers, classrooms, churches, small offices, and more OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft(70 ft. for Al2/18/24/30) • 24-hour continuous operation (cooling mode) • High pressure protection • Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers • Superior energy and operational efficiency OFFICE COPY Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US, Inc. SPECIFICATIONS: PKA-A18HA7 & PUZ-A18NKA7(-BS) Indoor UnitPKA-A18HA7 PUZ-A18NKA7 Model Number Outdoor Unit PUZ-A18NKA7-BS Maximum Capacity Btu/h 18,000 Rated Capacity Btu/h 18,000 Minimum Capacity Btu/h 8,000 Maximum Power Input W 1,820 — Cooling*1W 1,820 Rated Power Input Moisture Removal Pints/h 5.20 Sensible Heat Factor 0.68 Power Factor % 95.30 Maximum Capacity Btu/h 22,000 Rated Capacity Btu/h 19,000 Minimum Capacity Btu/h 7,700 Heating at 47° F*2 W 1,800 Maximum Power Input Rated Power Input W 1,300 Power Factor % 94.20 Maximum Capacity Btu/h 13,900 Rated Capacity Btu/h 11,300 Heating at 17° F*3 W 1,430 Maximum Power Input Rated Power Input W 1,340 SEER 18.50 EER*1 9.90 Efficiency HSPF (IV) 10.20 COP at 47° F*2 4.28 COP at 17° F*3 2.47 Voltage, Phase, Frequency 208/230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 198–253 Voltage: Indoor-Outdoor, S1-S2 V AC 208/230 Electrical Voltage: Indoor-Outdoor, S2-S3 V DC 24 Voltage: Indoor-Remote controller V DC 12 Recommended Fuse/Breaker Size A 15 Recommended Wire Size (Indoor-Outdoor) AWG 14 Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc. SPECIFICATIONS: PKA-A18HA7 & PUZ-A18NKA7(-BS) Indoor Unit PKA-A18HA7 Model Number PUZ-A18NKA7 Outdoor Unit PUZ-A18N KA7-BS MCA A 1.00 Fan Motor Full Load Amperage A 0.33 Fan Motor Output W 30 Airflow Rate, Dry CFM 320-370-425 Airflow Rate, Wet CFM 290-335-380 External Static Pressure in.WG n/a Sound Pressure Level dB(A) 36-40-43 Drain Pipe Size In. (mm) 5/8 (16) Condensate Lift Mechanism, Max. Distance Ft. (m) n/a Indoor Unit Heat Exchanger Type Plate fin coil External Finish Color White Munsell 1.0Y 9.2/0.2 W: In. (mm) 35-3/8 (898) Unit Dimensions D: In. (mm) 9-13/16(249) H: In. (mm) 11-5/8 (295) W: In. 39-6/16 Package Dimensions D: In. 15-12/16 H: In. 13-6/16 Unit Weight Lbs. (kg) 29(13) Package Weight Lbs. 33 Indoor Unit Cooling Intake Air Temp (Maximum/Minimum) ° F 90 DB, 73 WB/66 DB, 59 WB Operating Heating Intake Air Temp(Maximum/Minimum) ° F 82 DB/50 DB Temperature Range MCA A 11 MOCP A 28 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 46 Outdoor Unit Airflow Rate CFM 1,590 Refrigerant Control Electronic Expansion Valve Defrost Method Reverse Cycle Heat Exchanger Type Cross fin Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc. SPECIFICATIONS: PKA-A18HA7 & PUZ-A18NKA7(-BS) Indoor Unit PKA-A18HA7 Model Number PUZ-A18NKA7 Outdoor Unit PUZ-A18NKA7-BS Sound Pressure Level, Cooling*1 dB(A) 44 Sound Pressure Level, Heating*2 dB(A) 46 Compressor Type INVERTER-driven twin rotary Compressor Model SNB130FNCM2 Compressor Rated Load Amps A 7 Compressor Locked Rotor Amps A 12 Compressor Oil Type//Charge oz. FV5OS/116 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater n/a W: In. (mm) 31-13/16 +7/16(809+62) Unit Dimensions D: In. (mm) 11-3/16(300) H: In. (mm) 24-13/16 (630) W: In. 37-1/16 Package Dimensions D: In. 16-3/16 H: In. 27-7/16 Unit Weight Lbs. (kg) 100 (45) Package Weight Lbs. (kg) 112 (51) Outdoor Unit Cooling Intake Air Temp (Maximum/Minimum) °F 115 DB/0* DB Operating Heating Intake Air Temp(Maximum/Minimum) °F 70 DB, 59 WB/ 12 DB, 10 WB Temperature Range Thermal Lock-out/Re-start Temperatures** °F 8/ 12 DB Type R410A Refrigerant Charge Lbs, oz 4 lbs, 14 oz Gas Pipe Size O.D. (Flared) In.(mm) 1/2 (12.7) Liquid Pipe Size O.D. (Flared) In.(mm) 1/4 (6.35) Piping Maximum Piping Length Ft. (m) 100 (30) Maximum Height Difference Ft. (m) 100 (30) Maximum Number of Bends 15 Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc. SPECIFICATIONS: PKA-A18HA7 & PUZ-A18NKA7(-BS) AHRI Rated *1 Cooling (Indoor//Outdoor) °F 80°F DB, 67°F WB//95°F DB, 75°F WB Conditions(Rated *2 Heating at 47°F (Indoor//Outdoor) °F 70°F DB, 60°F WB//47°F DB,43°F WB data is determined at a fixed *3 Heating at 17°F (Indoor//Outdoor) °F 70°F DB, 60°F WB// 17°F DB, 15°F WB compressor speed) Conditions *4 Heating at 5°F(Indoor//Outdoor) °F 70°F DB, 60°F WB//-4°F DB, -5°F WB Notes *Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0°F- 115°F. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures SEACOAST PROTECTION • External Outer Panel: Phosphate coating +Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • "Blue Fin"treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Notes: Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc. ACCESSORIES: PKA-A18HA7 3-Pole Disconnect Switch (30A/600V/UL) [fits 2"X 4" utility box] ❑ TAZ-MS303 Drain Pan Level Sensor(Control for indoor unit shut off to prevent drain pan overflow) ❑ DPLS2 MaxiBlue Advanced Blue Diamond Mini-Condensation pump w/Reservoir&Sensor(110V) o X87-711 - 110 up to 48,000 Btu/h [recommended] MaxiBlue Advanced Blue Diamond Mini-Condensation pump w/Reservoir&Sensor o X87-721 -208/230 (208/230V)up to 48,000 Btu/h [recommended] MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) o XA5-003 Fascia Kit for MicroBlue Pump—mounts beneath pump ❑ T18-016 Extension Cord for Blue Diamond Pump o C13-103 Sauermann Mini-Condensation pump (115V) o SI30-115 Sauermann Mini-Condensation pump(230V) ❑ SI30-230 MegaBlue Blue Diamond Condensate Pump (110-230V) ❑ X87-835 Remote Sensor(extensible) o PAC-SE41TS-E Connector for CN32 (remote ON/OFF) ❑ PAC-SE55RA-E Connector for CN152 (Back up heating) ❑ PAC-SE59RA-E External fan/Heater control relay adapter ❑ CN24RELAY KIT-CM3 Backlit,wall-mounted,wireless ❑ MHK1 Wireless Remote Controller ❑ MRCH1 Wireless Receiver ❑ MFH1 Portable Central Controller ❑ MCCH1 Outside Air Sensor o MOS1 Wireless adapter ❑ PAC-USWHS002-WF-1 BACnet®and Modbus Interface o PAC-UKPRC001-CN-1 Wall-mounted, Wired 0 PAC-YT53CRAU-J Wired Remote Controller o PAR-33MAA-J T-STAT Interface o PAC-US444CN-1 Simple remote controller ❑ PAC-YT53CRAU Wireless Remote Controller o PAR-FL32MA-E Wire for Remote ON/OFF with CN32 connector o PAC-715AD Lockdown Bracket for wireless, hand-held, remote controllers ❑ RCMKPI CB Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc. ACCESSORIES: PUZ-A18NKA7(-BS) Air Outlet Guide ❑ PAC-SJ07SG-E Front Wind Baffle o WB-PA4 Hail Guard o HG-A5 Drain Socket o PAC-SJO8DS-E Centralized Drain Pan o PAC-SG63DP-E Control/Service Tool ❑ PAC-SK52ST Wall Mounting Bracket(Powder-coated Steel) ❑ QCWB2000M-1 Wall Mounting Bracket(316 Series Stainless Steel) o QSWBSS M-NET Control Adapter for Building Management System ❑ PAC-SJ19MA-E Outdoor Unit Mounting Pad 16"x 36"x 3" o ULTRILITE1 Outdoor Unit 3-1/4 inch Mounting Base- Pair(Plastic) o DSD-400N MiniSplit Mounting Stand-Single Fan Models- 12" o QSMS1201 M MiniSplit Mounting Stand-Single Fan Models- 18" o QSMS1801 M MiniSplit Mounting Stand-Single Fan Models-24" o QSMS2401 M 1/4 x 1/2 x 15'/ 1/2" Lineset(Twin-Tube Insulation) o MLS141212T-15 1/4 x 1/2 x 30'/ 1/2" Lineset(Twin-Tube Insulation) o MLS141212T-30 1/4 x 1/2 x 50'/ 1/2" Lineset(Twin-Tube Insulation) o MLS141212T-50 1/4 x 1/2 x 65'/ 1/2" Lineset(Twin-Tube Insulation) o MLS141212T-65 1/4 x 1/2 x 100'/ 1/2" Lineset(Twin-Tube Insulation) o MLS141212T-100 Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US, Inc. DIMENSIONS: PKA-A18HA7 & PUZ-A18NKA7 (-BS) PKA-A18HA7 Unit:inch(mm) 15-3/1.357 7.112 192 Top s/do r -- IIII;�ii�i11wi:1111ii111 mE.ii��� i!i...E Mount board -- 2191161599) kont Side ROI title iipIIIF 1 F ''t i 31 27- �6wrolM Diwng 551 Fmn1111.668_ 114 898 NM IL169) Y16(5) Knock out hole1 D e�a.lcdr roan) w^D6t neann (purmeese6rally) Tb`°ugh 6tla "' l I 1 i II I 7f p2-112-QY,1 a2-12-¢1116 ",r - 11 ¢65-001 Ipss-0001 II % m.^.!..w�nmo,* ' �liiiiii,ii �nna�a�tme I ii 1 MI I= I '/5-r.,. ,5tlfi14571G-oma ,5.0 9) Em.9an�.roe4200551' Drain Msa 21-311fi15397Lpuld DRa fi-311oow Iwctn96np�g1 /4161184) Vane auto neer We ,0,._pen . DEFROST/STAND ebm Y • 'g IIIIMIMIIMIMII 20.1/16)612)4 —I _- .11 ReNge6M LiWid pipe 1/4F(006.35) _. Piping Gas pipe 112F()12.7) 1M1== iirl g542(016)0.0 emsiall Drain hose Effective length:15-3/4(400)ill `v Louv.,manual / Krmck ow title 55.11er C Mbwa DMn9 B Center measurement hale•3132...5 4-$5/1610.9) Mount boats 904 hole VagNg ar$u R'n—,n, indmr411i10udine tie a -- a"a im$m .;G:0517 n.q n a r et aid' Ta .,r1:2r_io��i oeimprIll —oatsl2,8, il 518216)0 �— Vie_.-.- ,�—La29) 119:16(471 --•u •-- it 'fly 1-114707/ 319/178.5) law.iiiiss mitt �---m i;1h 5) �y I..� 6121166) ft� W 71176.51 1VZ ��Ci�aa� 6((203.51 iii■Ia iii► 9-18(232.5) �� �_� 41116215) 9-t 51161253.5) ���� - 0.3i4(2]3.2) Ill�rISI�INIIMMMI►ia , tan raa,•— $' 11 me m "7:01 'caSw a VIYl n�fww. aN�a m —I', Reeuired specellntloor unlD K note far Mang (mm) A ice» = ".. ����I 1 1 p T...1ce1.111. r..-•1-11116140) — e 11 dMm.t-I,Bz160) Ae ue1 d9 d 1111 2:mil 'r`_ £ l g M(22n) W.^S]B(150) // 1-11116143) '° ®. D Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US, Inc. DIMENSIONS: PKA-A18HA7 & PUZ-A18NKA7 (-BS) PUZ-A18NKA7(-BS) Unit:mm<in> 404.5<15-15/16> drain hole Air intake +42 2-U Sha.-notched holes 1 Installation•oil pitch (Foundation Bolt WNW 3/8>) ♦ 500>19-1/16> -- �NMI . Mill Airintake I HIIIIMIUMMIIIIIIIIT - Air discharge I -0<1-19/32<4 T. 23.2<15/16> 22.3<29/32> Wn'ation>,r I Service panel <W 3/8>) 92<7/8> Term nal connection for charge plug Left Power supply wiring > Right Indoor/Outdoor wiring y/ Handle formovinc ■I 1 lI�—" Connectionfor l,l � It I'll 1rteL liquid pipe FLARE 0.35(1/4F) e, t Earth terminal i' I�rll'I N 2 A ,Service,anal II( i Iw, d „ I'C'I�' �'ill�l . • ,,,, -' 1/2 conduit hole Connection for gas pipe FLARE 012.7(1/2F) 154.5<6-3/32> L „�' Service port 185.5<75/16> 310<t2-7/32> I h — m 809<31-7/8< 62<2-15/32> m Free space around the outdoor unit FOUNDATION BOLTS (basic example) Please secure the unit firmly ^ with 4 foundation(M10<W3/8>)bolts. L\ (Bolts,washers and nut must E. 100mm<3-15/16>or more as long as be purchased locally). no obstacle is placed on the rear and right-and-left sides Vf� of the unit <Foundation bolt height> C MM IOOmm\ MIn 'n' n'3-i i ✓/ <1s-2srs1> Cg FOUNDATION E �m I� PIPING-WIRING DIRECTION CMn 600.nm \ / M3n1 006 ✓/ \V V/ Piping and wiring connection can be made from the rear direction only. 2 odes should be open in the right,left and rear ode. MSW MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com LOOP CERTIFIED. o us me FORM#PKA-A18HA7/PUZ-A18NKA7(-BS)-201709 ,.. Intertek Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc.