Report STREET TREE
TIGARDCERTIFI
cArroly
A,02,., , owner/agent for \ ,-4.i,-. {
(PLEASE PRINT) (PERMIT HOLDER)
do hereby cert that the following location meets
City of Tigard land use and development standards
for street tree installation and is consistent
with the approved site plan.
PERMIT NO.: 3 - oo _9-2-
Sri E ADDRESS. O S $ ��
SUBDIVISION. CtY \d Ls—
LOT#:
SIGNATURE.. 46,41
DAlE: -�c- 18
WNER/AGENT)
RECEIVED &
VERIFIED BY:
DA 1h: ./1„/11,26///g.(CITY OF TI RD)
❑ Tree location verified per approved site plan.
I:\Building\Forms\StreetTreeCertificate 05/30/2012
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: P. Jurisdiction:
\( c.,..Arej
Site Address: J
&),� . 5,,,..) �� mow+„-, S
Subdivision/Lot#: Ctv
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty (50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1 LU--§:�
Signature: r Date: )f-d{S.---
Owner/ eneral Contractor/Authorized Agent 4xcttv PrintName: l
1 ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\Building\Forms\RES-HighEfficiencyLighting.doc 07/01/08
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
\ , am the general contractor or the owner-builder
at the following address:
Site Address: cu
City:
N
e CA—r-01
Permit#:
i 0-0 - vc ( 1-,D
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code (ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
`i Signature: Date: ���S '
en- al Contractor or Owner-Cull.er
L\Building\Fonn\RES-MoistureSensitiveWood.doc 09/25/08
Four Walls, Inc.
Home Energy Efficiency
PO Box 231062
Portland, OR 97281-1062
CCB#146968
PTCS#2194
Phone: 503-547-7139
fourwallsbps(r�gmail.com
Whole House Leakage Affidavit
Permit#: Builder: JT Roth
Site Address: 8015 SW Barnum St, Tigard OR
Cond. Floor Area (sq ft ): 3511 Source: Plans Estimated Measured
Whole House Leakage Test Target: 6 ACH or less Test result 5.51 ACH
2940 cfm50 Ring 0 Al B2 Building Volume (cu ft): 31,999
Minneapolis Blower Door w/DG 700 manometer
I certify that these test results are accurate and determined using PTCS testing protocol.
Company Name: Four Walls Inc Technician: Ron Nardozza/Todd Poehlman/Jan Barlow
Ron NardozzaDigitally
a
Date:2018.04.25 531"a-0i o
Technician Signature: Date:April 25, 2018