Specifications -4 Project C_Bi i Construction Lot 6 Oak Woods page Avery 99 � -�—+—� Keith A Kudrna Location:Beam Nr.09-Rear Patio Roof Beam Suntel Design Roof Beam " 16865 Boones Ferry Rd of/ [2012 International Building Code(2012 NDS)] ,., - Lake Oswego,Oregon 97035 3.5 IN x 9.25 IN x 10.0 FT #2-Douglas-Fir-Larch(North)-Dry Use StruCalc Version 10.0.1.6 1/18/2018 7:33:14 AM Section Adequate By:30.4% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.12 IN L/1010 Dead Load 0.06 in Total Load 0.18 IN U658 Live Load Deflection Criteria:U240 Total Load Deflection Criteria:U180 REACTIONS A la Live Load 975 lb 975 lb Dead Load 522 lb 522 lb Total Load 1497 lb 1497 lb Bearing Length 0.68 in 0.68 in BEAM DATA Span Length 10 ft Unbraced Length-Top 0 ft 10a Unbraced Length-Bottom 0 ft Roof Pitch 0 :12 Roof Duration Factor 1.15 ROOF LOADING MATERIAL PROPERTIES Side One: #2-Douglas-Fir-Larch(North) Roof Live Load: LL= 30 psf Rase Values Adjusted Roof Dead Load: DL= 15 psf Bending Stress: Fb= 850 psi Fb'= 1173 psi Tributary Width: TW= 1.5 ft Cd=1.15 CF=1.20 Side Two: Shear Stress: Fv= 180 psi Fv'= 207 psi Roof Live Load: LL= 30 psf Cd=1.15 Roof Dead Load: DL= 15 psf Modulus of Elasticity: E= 1600 ksi E= 1600 ksi Tributary Width: TW= 5 ft Min.Mod.of Elasticity: E_min= 580 ksi E_min'= 580 ksi Comp.-L to Grain: Fc-1= 625 psi Fc--1-'= 625 psi Wall Load: WALL= 0 plf Moment: 3742 ft-lb SLOPE/PITCH ADJUSTED LENGTHS AND LOADS Controlling from left Moment: Adjusted Beam Length: Ladj= 10 ft 5.0 Beam U Created by combining all dead and live loads. Weight: w = = 7 plf Beam Uniformif Live Load: L= 195 plf Controlling Shear: 1287 lb Beam Uniform Dead Load: wD_adj= 104 plf At a distanced from support. Total Uniform Load: wT= 299 plf Created by combining all dead and live loads. Comparisons with required sections: Read Provided Section Modulus: 38.28 in3 49.91 in3 Area(Shear): 9.33 in2 32.38 in2 Moment of Inertia(deflection): 63.14 in4 230.84 in4 Moment: 3742 ft-lb 4879 ft-lb Shear: 1287 lb 4468 lb NOTES Project:Avery C_Biggi Construction_Lot 6 Oak Woods • "NW Page Keith A Kudrna Location:Beam Nr.11 -Rear Deck Beam Suntel Design Uniformly Loaded Floor Beam 16865 Boones Ferry Rd or [2012 International Building Code(2012 NDS)] Lake Oswego,Oregon 97035 3.5 IN x 11.25 IN x 9.5 FT #2-Douglas-Fir-Larch(North)-Dry Use StruCalc Version 10.0.1.6 1/18/2018 7:33:15 AM Section Adequate By:42.3% Controlling Factor:Moment DEFLECTIONS Center I-OADING DIAGRAM Live Load 0.08 IN L/1378 Dead Load 0.02 in Total Load 0.10 IN L/1154 Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240 REACTIONS L4 B Live Load 1425 lb 1425 lb Dead Load 277 lb 277 lb Total Load 1702 lb 1702 lb Bearing Length 0.78 in 0.78 in SEAM DATA Center Span Length 9.5 ft Unbraced Length-Top 0 ft Floor Duration Factor 1.00 Notch Depth 0.00 MATERIAL PROPERTIES FLOOR LOADING #2-Douglas-Fir-Larch(North) Side 1 Side 2 Base Values Adjusted Floor Live Load FLL= 60 psf 0 psf Bending Stress: Fb= 850 psi Fb'= 935 psi Floor Dead Load FDL= 10 psf 0 psf Cd=1.00 CF=1.10 Floor Tributary Width FTW= 5 ft 0 ft Shear Stress: Fv= 180 psi Fv'= 180 psi Cd=1.00 Wall Load WALL= 0 plf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi BEAM LOADING Comp.-L to Grain: Fc-1= 625 psi Fc- = 625 psi Beam Total Live Load: wL= 300 plf nt: Controlling Moment: 4043 ftIb Beam Total Dead Load: wD= 50 plf seBeam Self Weight: BSW= 8 plf 4.7ft from left Created by combining all dead and live loads. Total Maximum Load: wT= 358 plf Controlling Shear: -1396 lb At a distance d from support. Created by combining all dead and live loads. Comparisons with required sections: Req'd Provided Section Modulus: 51.89 in3 73.83 in3 Area(Shear): 11.63 in2 39.38 in2 Moment of Inertia(deflection): 108.49 in4 415.28 in4 Moment: 4043 ft-lb 5752 ft-lb Shear: -1396 lb 4725 lb NOTES ��1�� page Project:Avery C_Biggi Construction Lot 6 Oak Woods us_.—'-- Keith A Kudrna Location:Beam Nr.11 a-Rear Deck BeamSuntel Design Multi-Span Floor Beam 16865 Boones Ferry Rd of [2012 International Building Code(2012 NDS)] ,�,t'"— Lake Oswego,Oregon 97035 3.5 IN x 12.0 IN x 15.25 FT(2.2+13) 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 10.0.1.6 1/18/2018 7:33:15 AM Section Adequate By:27.5% Controlling Factor:Deflection DEFLECTIONS Loft Center LOADING DIAGRAM Live Load -0.12 IN 2L/458 0.21 IN U734 Dead Load -0.02 in 0.04 in Total Load -0.14 IN 2L/392 0.25 IN L/621 Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240 REACTIONS A B Live Load 2683 lb 1950 lb Dead Load 529 lb 373 lb Total Load 3212 lb 2323 lb Bearing Length 1.41 in 1.02 in REAM DATA Left Center Span Length 2.25 ft 13 ft Unbraced Length-Top 0 ft 0 ft I-2.25ft 13 ft Unbraced Length-Bottom 0 ft 13 ft Floor Duration Factor 1.00 Notch Depth 0.00 FLOOR LOADING Let Center MATERIAL PROPERTIES Floor Live Load FLL= 60 psf 60 psf 24F-V4-Visually Graded Western Species Floor Dead Load FDL= 10 psf 10 psf Base Values Adjusted Floor Tributary Width Side One TW1 = 5 ft 5 ft Bending Stress: Fb= 2400 psi Controlled by: Floor Tributary Width Side Two TW2= 0 ft 0 ft Fb_cmpr= 1850 psi Fb'= 2400 psi Wall Load WALL= 0 plf 0 plf Cd=1.00 REAM LOADING Left Center Shear Stress: Fv= 265 psi Fv'= 265 psi Reduced Floor Live Load 60 psf 60 psf Cd=1.00 Total Live Load 300 plf 300 plf Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi Total Dead Load 50 plf 50 plf Comp.-I-to Grain: Fc-1= 650 psi Fc-1'= 650 psi Beam Self Weight 9 plf 9 plf Total Load 359 plf 359 plf Controlling Moment: 7511 ft-lb 6.5 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: 2077 lb At a distance d from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)1,2 Comparisons with required sections: Req'd Provided Section Modulus: 37.56 in3 84 in3 Area(Shear): 11.76 in2 42 in2 Moment of Inertia(deflection): 395.42 in4 504 in4 Moment: 7511 ft-lb 16800 ft-lb Shear: 2077 lb 7420 lb NOTES