Loading...
Report (11) { PRIME ELECTRICAL RECEIVED SERVICES, LLC. MAY 15 2018 Electrical ♦Communications ♦ Life Safety♦Security♦ CCTV CITY OF TIGARD PO Box 872395 Vancouver,WA 98687-Phone(503)318-5170 BUILDING DIVISIOi COPY FIRE ALARM SYSTEM SUBMITTAL RICOH TI 9020 SW Washington Square Rd. Tigard, OR 97223 May 14, 2018 Proposed by Prime Electrical Services, LLC PO 18-140 Project Manager: Oleg Primachenko CALY,AO , L :Calloc•fit k 111 C 5495 Technical Specifications • Model 5495 Block Diagram For a complete listing of all compliance approvals and certifications,please visit www.silentknight.com. Signal Circuit Output Signal 1 Signal 1 Input Distributed Signal 2 Windows,Windows,are and Signal Circuit Output Signal 2 P W the Logotrademarks ( Signal registered Module S48$ or trademarks of (Optional) $ nal4 Microsoft Corporation. 120 VAC Aux,Power System Sensory and Honeywell°are registered Trouble Output trademarks of Honeywell Local Fire Control (Afternative to notification International,Inc circuit trouble.) This document is not SUPERVISION intended to be used for Amps per output circuit:3.0(6.0 amps total) installation purposes.We The 5495 supervises a variety of functions Notification circuit output:Alarm Current(for try to keep our product including: typical voltages)drawn from main panel's information up-to • Low AC power notification appliance circuits. date and accurate.We 12 VDC 6.5 mA cannot cover all specific • Low battery condition applications or anticipate 24 VDC One input circuit:15 mA;Both input all requirements.All • Earth ground fault circuits:0 mA specifications are subject • Auxiliary output power limit condition No.of inputs:2 to change without notice. • EOL supervision trouble or power limited Input configuration:2 Class B or 2 Class A For Technical Support, condition at an output Input voltage range:9-32VDC call 800-446-6444 When a trouble condition occurs,the 5495 creates Battery charging capacity:35.OAH a trouble condition on the host control signal circuits to which it is connected.the 5495 still INDICATOR LIGHTS maintains the ability to be activated by the host AC power on:Green control.In addition,the 5495 provides a Form C Battery trouble:Yellow trouble relay output as an alternative to using the Ground fault:Yellow notification circuit trouble. Aux trouble:Yellow PHYSICAL Output troubles(1-4):Yellow Dimensions:12.25"W x 16"H x 3"D(30.88 cm W x ORDERING INFORMATION 40.64 cm H x 7.62 cm D) 5495:Distributed Power Module ENVIRONMENTAL ACCESSORIES Operating Temperature:32°F to 120°F (0°C to SK-SCK:Seismic Compliance Kit 49°C) Humidity:10%-93%non-condensing) AGENCY LISTINGS ELECTRICAL • UL listed AC input:120 VAC at 2A • CSFM 7300-0559:123 Output:24 VDC at 6A • Meets NFPA 72 requirements Current:Standby 75mA;Alarm 205mA Auxiliary power circuit:1 • MEA 429-92-E Vol XII Notification circuits:4 • OSHPD(CA)OSP-0065-10 Output configuration:2 Class A(Style Z);4 Class B (Style Y)(1 Class A&2 Class B) For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 C' Doc 3503951 Rev HI 11/17 r,SILENT' 800-328-0103 ©2017 Honeywell International Inc. P841 KNIGHT SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync-Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30, 75,95,1 10,115,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/s-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"Lx4.7"Wx1.3"D(142mmLx119mmWx33mmD) Wall-Mount Back Box Skirt Dimensions(BBS-2,BBSW-2) 5.9"L x 5.0"W x 2.2"D(151 mm L x 128 mm W x 56 mm D) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS,TRW-HS) 5.7"L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P S,PC,and SC products will operate at 12V nominal onlyfor 15 and 15/75 cd. AVDS00600 UL Current Draw Data • UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR - Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 temporal High 245 259 290 297 Temporal High 215 231 258 265 lernporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8' Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 • 'Settings 7,8,and 9 are not available on 2-wire horn strobes. AVDS00600 SpectrAlert Advance Dimensions 4.7" 1 2.5=—• 5.05' 2.231 1. r ,. 99 Q . 5.6" 5.98"J ( III III) ,: ii0 c ( III c r, 0 r S . o 6 7 `o ' Z� �� ���� ,-- Wall-mount _Wall-mount horn strobes Wall back box skirt SpectrAlert Advance Ordering Infor . ion Model Description Model Description Wall Horn Strobes Horns P2R*1 2-Wire Horn Strobe,Standard cd#,Red HR Horn,Red P2RH* 2-Wire Horn Strobe,High cd,Red HW Horn,White P2W* 2-Wire Horn Strobe,Standard cd,White Accessories P2WH* 2-Wire Horn Strobe,High cd,White BBS-2 Back Box Skirt,Wall,Red P4R* 4-Wire Horn Strobe,Standard cd,Red BBSW-2 Back Box Skirt,Wall,White P4RH 4-Wire Horn Strobe,High cd,Red TR-HS Trim Ring,Wall,Red P4W 4-Wire Horn Strobe,Standard cd,Whit TRW-HS Trim Ring,Wall White Wall Strobes SR*t Strobe,Standard cd,Red SRH*f Strobe,High cd,Red SW* Strobe,Standard cd,White SWH* Strobe,High cd,White Notes: "Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P211-P. t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. t"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. 4 ! SYSTENI ©2011 System Sensor. SENSORS 3825 Ohio Avenue•St.Charles,IL 60174 aodc sae ato b1e to change stn t of e nstsy temsen r:m for Phone:800-SENSOR2•Fax:630-377-6495 urrentproduct mformation,Including the latest vergonoftnudata sheet AVDS00600.6/11•#2807 SYSTEM SENSOR Indoor Selectable Output Strobes and Horn Strobes for Ceiling Applications ' let ,t SpectrAlerto Advance audible visible notification products 5;„ are rich with features guaranteed to cut installation times SPECTFrt and maximize profits. eristry Features The SpectrAlert Advance series offers the most versatile and Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. • With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at 15 and can meet virtually any application requirement. 15/75 candela Like the entire SpectrAlert Advance product line,ceiling-mount • Field-selectable candela settings on ceiling units: 15, 15/75,30, 75,95, 110, 115, 135, 150, 177,and 185 strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature a plug-in design with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,SpectrAlert Advance utilizes a before device installation universal mounting plate so you can mount them to a wide array • Electrically Compatible with legacy SpectrAlert devices of back boxes.With an onboard shorting spring, installers can test • Compatible with MDL3 sync module wiring continuity before the device is installed. • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING ® IMEAQLISTED Apapproved 7125-1653:0186(indoor strobes) 7125-1653:0188(horn strobes, • 54011(chimes,horn strobes,horns) 3023572 MEA452-05-E chime strobes) S5512(strobes) 7135-1653:0189(horns,chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync•Circuit° Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance.Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2,5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCR,SBBCW) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS10101 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 ' UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. AVDS10101 SpectrAlert Advance Dimensions 6.8" 6.922" I—2.5" • Dia. �� d: III \ �, g:- g 1- ___,„,.\., __..----) I I , I/'/ N' 0 0 0 i---_ I. z a 1 j ' (*) J Ceiling-mount horn strobes Ceiling back box surface mount back box SpectrAlert Advance Ordering Information • Model Description Model Description Ceiling Horn Strobes Ceilin. Strobes PC2R 2-Wire Horn Strobe,Standard cd,Red J .CR Strobe,Standard cd,Red • PC2R-P 2-Wire Horn Strobe,Standard cd,Red,Plain SCRH Strobe,High cd,Red (no"FIRE")marking SCW Strobe,Standard cd,White PC2RH 2-Wire Horn Strobe,High cd,Red SCW-P Strobe,Standard cd,White,Plain(no"Fire")marking PC2W 2-Wire Horn Strobe,Standard cd,White SCWH Strobe,High cd,White PC2W-P 2-Wire Horn Strobe,Standard cd,White,Plain Accessories (no"FIRE")marking SBBCR Surface Mount Back Box,Ceiling,Red PC2W-SP 2-Wire Horn Strobe,Standard cd,White,"Fuego" SBBCW Surface Mount Back Box,Ceiling,White marking PC2WH 2-Wire Horn Strobe,High cd,White PC2WH-P 2-Wire Horn Strobe,High cd,White,Plain (no"FIRE")marking PC2WH-SP 2-Wire Horn Strobe,High cd,White,"Fuego" PC4R 4-Wire Horn Strobe,.Standard cd,Red PC4RH 4-Wire Horn Strobe,High cd,Red PC4W 4-Wire Horn Strobe,Standard cd,White Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. *T SYSTEM ©2015 System Sensor. ▪ �� SENSOR' 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Vsasystemsensoccon Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS10102•03/15