Loading...
Report (3) STREET TREE TIGARD CER TIFICA T ION kks-h� , owner/agent for 31 goo, -; (LEASE PRINT) (PERMIT HOLDER) do hereby cert that the following location meets City of Tigard land use and development standards for street tree installation and is consistent with the approved site plan. PERMIT NO.: M i Lo - L>(>-2- SIl E ADDRESS: bo 8 t- �\s,-) C SUBDIVISION.• , �� LOT#: SIGNATURE: � � DATE: - (OWNER/AGENT) " RECEIVED & /' d VERIFIED BY. (CITY 0 TIGARD) DALE: J /I ❑ Tree location verified per approved site plan. / I:\Building\Form\StreetTreeCertificate 05/30/2012 Oregon Residential Specialty Code N1107.2 HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS Permit No.: vl 1 ( sl __,t)`..1._T Do.:?_? �.s Jurisdiction: Ti-30_,E01 Site Address: )v—, ?:)43,.AA.,tev,.., L5vi,e,4- Subdivision/Lot#: C r ,i0 A- t) and/or Map and Tax Lot#: By my signature below, I certify that all of the permanently installed lighting fixtures in the above mentioned building contain high-efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement. (Oregon Residential Specialty Code N1107.2)1 Signature: y4.-/ ^� ----4 •- Owner/General Contrac or/Authorized Agent Date: 2 '-jj Print Name: /ice .- (ro7--4 ORSC Section N1107.2.High-efficacy lamps. All permanently installed lighting fixtures shall contain high- efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement. The building official shall be notified in writing at the final inspection that the permanently installed lighting fixtures have met this requirement. Exception: Two permanently installed lighting fixtures are not required to have high-efficacy lamps. IABuildingTonns\RES-HighEfficiencyLightingAcknowledgement 022018 Four Walls, Inc. Home Energy Efficiency PO Box 231062 Portland, OR 97281-1062 CCB#146968 PTCS#2194 Phone: 503-547-7139 fo u rwalls bps�a7gmail.com Whole House Leakage Affidavit Permit #: Builder: JT Roth Site Address: 8082 SW Barnum Drive, Tigard Lot 6 Cond. Floor Area (sq ft ): 2877 Source: Plans Estimated Measured Whole House Leakage Test Target: 6 ACH or less Test result D ACH cfm50 Ring&A1 B2 Building Volume (cu ft): 28,970 Minneapolis Blower Door w/DG 700 manometer I certify that these test results are accurate and determined using PTCS testing protocol. Company Name: Four W?.11s'1nc Technic.:n: Ron Nardozza/Todd P P./- n/Jan Barlow Technician Signature: t ._ Date: May 17, 2018 Oregon Residential Specialty Code R318.2 MOISTURE CONTENT ACKNOWLEDGEMENT FORM I ,1 LA (,x,.,,54-y ei1fet^, am the general contractor or the owner-builder at the following address: Site Address: o& 8 2. 5,„) City: 7-60-471 Permit#: 2_61/ _ 0aZ-33 Subdivision/Lot#: and/or Map and Tax Lot#: To conform with the 2017 Oregon Residential Specialty Code(ORSC), Section R318.2 and OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section R318.2 is provided for reference]. R318.2 Moisture Content: Prior to the installation of interior finishes, the building official shall be notified in writing by the general contractor that all moisture-sensitive wood framing members used in construction have a moisture content of not more than 19 percent by dry weight of dry framing members. Signature: Gene altntractor or Owner-Builder Date: - ��- I:\Building\Form\RES-MoistureContentAcknowledgement 022018