Loading...
Plans 4TXK1609A-SUB-1 C-EN TAG: SUBMITTAL R-410A Split System 16 Series, Inverter Systems - 60 Hz 4MXW1609A1 / 4TXK1609A1 Specifications MODEL-Heat Pump Only 4MXW1609A10NO/4TXK1609A10NO Cooling Heating RATED Volts/PH 208/230/1 Frequency(Hz) 60Hz Rated Cooling/Heating Capacity(Btu/h): 9000 9500 Minimum Cooling Capacity(0955 (Btu/h): 3100 Maximum Cooling Capacity(©95F)(Btu/h): 9600 RECEIVED Minimum Heating Capacity(@47F)(Btu/h): - 3100 Maximum Heating Capacity @47F) Btu/h : - 12000 Maximum HeatingCapacity(@17F)(Btu/h): - 5600 JUN 6 Total Capacity(W)(H h/Standard/Low): 2800/2600/900 3500/2700/900 2 Rated Power Input(W) 900 800 SENminal ER/HSPF Input Current(A) 16.004.0 3.6 CITY 9.0 F TIGARD Air Flow Volume(CFM)(H/M/L) 310/280/240/170 � � �� n 1 C Dehumidifying Volume(pt./h) 1.69 5 r EER(Btu/W hr)/COP 10.0 11.9 Indoor Veil 4MXW1609A10N0 Fan Motor Speed(r/min)(SH/H/M/L) 1350/1200/1050/750 1350/1200/1050/850 Fan Motor RLA(A) 0.20 Evaporator Aluminum Fin-Copper Tube Pipe Diameter(inch) 1/5 Row Fin Gap(inch) 2-1/18 Coil length(L)x depth(D)x coil width(W)(inch) 23 x 7/8 x 101/2 Output tp t of Swing Motor(W) 1.5 Fuse 3.15 Sound Power Level dB(A)(SH/H/M/L) 53/49/45/39 Sound PRESSURE Level dB(A)(SH/H/M/L)0 43/38/34/28 Uncrated Dimension(W/H/D) inch) 31 1/9 x 10 5/6 x 7 7/8 Crated Dimension of Package L/W/H)(inch) 34 x 10 2/3 x 14 4/9 Net Weight/Gross Weight(lbs 19.8/24.2 Outdoor Unit 4TXK1609A10NO Compressor ype Swing Rotary Compressor Oil DAPHNE FVC50K(PVE Oil) L.R.A.(A) 16.50 Compressor RLA(A) 6.60 Compressor Power Input(W) 845 Throttling Method Capillary Working Temp Range(°F) 0-115 -4.75 Condenser Aluminum Fin-Copper Tube Pipe Diameter(inch) 2/7 Row Fin Gap(inch) 1-1/18 Coil length(I)x depth(D)x coil width(W)(inch) 28 x 3/4 x 20 Fan Motor Speed(rpm) 820±20 Output of Fan Motor(W) 30 Fan Motor RLA(A) 0.37 Air Flow Volume of Outdoor Unit(CFM) 942 Fan Diameter(inch) 15 3/4 Defrosting Method Automatic Defrosting Sound Power Level dB(A) 62 Sound PRESSURE Level dB(A)0 52 Uncrated Dimension(W/H/D) inch) 30 5/9 x 21 1/4 x 12 3/5 Crated Dimension of Package(W/UH)(inch) 331/2 x 14 2/7 x 23 3/7 Net Weight/Gross Weight(lbs 65.0/70.6 Refrigerant Charge(oz) 24.7 MCA 9.0 MOP 15.0 Connection Pipe Gas additional charge(oz/ft) 0.2 Outer Diameter Liquid Pipe(inch) 1/4 Outer Diameter Gas Pipe(inch) 3/8 Max Height Distance(ft) 65 Max Length Distance(ft) 100 0 Sound PRESSURE Level 0 3.3 ft.dB(A) © 2018 Ingersoll Rand All Rights Reserved Unit Dimensions W D i t Mil 1111, 6 5/8 18 3/16 6 5/16 9K i rail b� �cc o f o� o 2.0 00 O o a p°� 1 023/16 u - 01 c23/16 1 i li 12Ti/1/ .�`:. �- ° x/12 1/8 The dimensions in these drawings 6 are rounded according to standard 3 1/?, measurement. Unit: inch MODEL W H D 09K 31 1/8 10 5/6 7 7/8 12K 33 1/4 11 3/8 8 1/4 10 1/8 28 [..: P. sr 1 ______________ _._________== ,..,.._,...„...2....._=,_,...........=_,. ..„__ _,. .. ._....=.=.7= _____._... __=„.....„ =__,.....:i_..___ .__:___=:=.___=...._..._=...__ _,.._...., 4 4_____.,)...._ e _-- -_- :.._. ___ , 6. _____i_ 12 3/5 30 9/16 i "CP, j The dimensions in these drawings are rounded according to standard measurement. !' ���*—�- 20 ro M Clearance Requirements Space to the ceiling or more --*—` Space to the wall artarig v6 in.or more � t= a . r I/ 6 in o more ...z:22,45_ yi t 1 ♦f..� J 1 . f I`�.`y�V�y Space to the wall `- - - ®1 4 18 in. 66 � or mor in. l r mor 1 IIS; r- Air outlet side • -- Space to the floor • The dimensions of the space necessary for correct • installation of the appliance including the minimum 0 permissible distances to adjacent structures ri I II rill Space to the obstruction \ 0 n 101 0 c /i %� 110 o J r Air inlet side P ' ' '. 11/4'`'r../ �, % X0 1 0 >' -' ' ,.2 in-or more I ��, / - r Space to the wall Sp-- to th-wall �' I $ r �� 0 ,20 in.or more' C ' y'i'ool.. ' ,. ....* v g�/ / `� • Airoutlet side NOTE: " Ii/ \valve cover The maximum recommended height from the floor to the bottom of the indoor unit is 11.5 ft.(3.5 m). Air Velocity Patterns for High Wall Max Horizontal Distance Unit:ft. (m) Model Cooling Mode Heating Mode 4MXW1609 13.1 (4) 13.1 (4) Performance Data 4TXK1609A10N/4MXW1609A10N and 4TYK1609A10N/4MYW1609A10N-Cooling Mode Performance Data Indoor Entering Air Temperature(Dry Bulb/Wet Bulb) Outdoor Ambient Air 68/57°F 73/61°F 79/64°F 80/67°F 82/68°F Temperature(°F) TC* SHC** TC SHC TC SHC TC SHC TC SHC 0 5500 4300 5800 4600 6200 4900 6600 5200 6700 5200 10 5700 4500 6000 4700 6400 5000 6800 5300 6900 5400 20 6000 4700 6400 5000 6800 5400 7300 5700 7400 5800 30 7100 5600 7700 6000 8200 6400 8400 6600 8500 6700 40 8300 6500 8900 6900 9200 7200 9500 7400 9600 7500 50 8300 6500 8900 6900 9200 7200 9500 7400 9600 7500 60 8100 6400 8700 6800 9000 7100 9400 7400 9500 7400 70 7900 6200 8400 6600 8900 6900 9200 7200 9300 7300 80 7600 6000 8100 6400 8600 6800 8900 7000 9000 7000 90 7400 5800 7900 6200 8500 6600 8800 6900 8800 6900 100 7200 5600 7700 6000 8300 6400 8600 6700 8600 6800 110 6900 5400 7400 5800 7900 6200 8300 6500 8400 6600 120 6600 5100 7100 5500 7600 5900 8000 6200 8100 6300 122 6600 5100 7000 5500 7500 5900 7900 6200 8000 6200 *Total Capacity**Sensible Heat Capacity 4TXK1609A10N/4MXW1609A10N-Heating Mode Performance Data Indoor Entering Air Temperature Outdoor Ambient Air 68°F 73°F 80°F 86°F Temperature(°F) TC* TC TC TC -4 4800 4800 4700 4600 0 5200 5200 5100 5000 5 5500 5500 5400 5300 . 10 5800 5700 5600 5500 15 5900 5900 5800 5700 20 6200 6100 6000 5900 25 6800 6800 6700 6600 30 7300 7300 7200 7100 35 7800 7800 7700 7600 40 8300 8300 8200 8100 45 9100 9000 8900 8700 50 9500 9400 9300 9100 55 9600 9500 9400 9200 60 9800 9700 9500 9300 65 10000 9900 9700 9500 70 10200 10100 9900 9700 75 10300 10200 10000 9800 *Total Capacity Capacities in these performance tables reflect normal operation at the temperatures indicated. See specifica- tion tables above for certified values under prescribed test conditions. Mechanical Specifications Mini-Split Outdoor Unit General Refrigerant Controls Condenser Coil This unit is fully charged from the factory for Refrigeration system controls include The coil shall consist of aluminum finned up to 25 feet of piping. This unit is designed condenser fan and compressor relay. coils brazed to copper tubing. The coil to operate at outdoor ambient temperatures High and low pressure controls are inher- Provides air flow resistance and efficient as high as 115°F.Cooling capacities with the ent to the compressor.A suction line heat transfer.The coil is protected by the mini-split air handler shown in the catalog are multi function service valve is standard casing. AHRI certified.The unit is ETL listed for out- door application. Compressor Low Ambient Cooling p Unit Casing The compressor features internal over Matched American Standard ductless temperature and pressure protection; products,have cooling capabilities at out- The unit casing is constructed of heavy total dipped hermetic motor windings. door ambient temperatures as low as 0°F. gauge, galvanized steel and painted with a Other features include:centrifugal oil weather-resistant powder paint. pump and low vibration and noise. Mini-Split Indoor High Wall General Discharge Airflow and Distribution Remote Controller System The High Wall mounted type air handler The unit shall have a wireless infrared re- shall be completely factory assembled Unit shall have auto swing,dual horizon- mote controller with easy reading digital including coil,condensate drain pan,fan tal blades to optimize the aperture outlet display panel to start,stop and regulate motor,washable filter,air purifying filter and for vertical airflow and air distribution. the air conditioner from a distance. electric controls to be used with a wireless Blade shall close automatically when the The wireless controller is available for all remote controller.Unit shall be shipped with air conditioner is turned off to minimize units.(Sold separately) a unit mounting plate.Unit shall be matched dust entering the unit.Five-Step preset with an American Standard outdoor unit, program on the remote controller shall be Healthy Filters rated and tested in accordance with AHRI available to control the blade angle. standard.Unit shall be ETL listed. Manually adjusted wide-angle louvers The unit shall have an active carbon and shall be provided to adjust the coverage catechin filter with the unit.The filters Unit Casing and direction of airflow. need to be cleaned at least once a year. Casing shall be provided with knockouts on Controls the right,and left of the unit to facilitate pip- ing and electrical connection on either side of the unit.An electrical service cover shall be Units shall have the capability to be con provided to permit easy access to the electri• trolled remotely through wall-mounted cal terminal strip. wired options as well as a wireless remote option. AIL riue :��1 CERTIFIED, anldtrectery.nrg V5 Unitary Smal AC NrrTlO ANAI Stan lard 210/240 Intertek g1/ta The manufacturer has a policy of continuous product and product data improvement and it reserves the right / ,feIngersoll Rand to nhange decign and apenifications without notice