Report
tIjILlWorldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage • General NOTICE The TYCO Series TY-FRB Sprinklers Description described herein must be installed , and maintained in compliance with The TYCO Series TY-FRB,5.6 K-factor, this document, as well as with the S ,, Upright (TY313) and Pendent (TY323) applicable standards of the National Sprinklers described in this data sheet Fire Protection Association,in addition ` are quick response,standard coverage, to the standards of any other authori- decorative 3 mm glass bulb-type spray ties having jurisdiction.Failure to do so ".. ,• sprinklers designed for use in light or may impair the performance of these ordinary hazard,commercial occupan- devices. p ng mallscies such as banks, hotels, and shop The owner is responsible for main _. taining their fire protection system The recessed version of the Series and devices in proper operating con- TY-FRB Pendent Sprinkler, where dition. Contact the installing contrac- applicable, is intended for use in areas tor or product manufacturer with any :.1.1,ift_,„*"..:.-1-•••.4-t•" .,. ,.,,,•••*:-.•-• , with a finished ceiling. This recessed questions. pendent sprinkler uses one of the `° following: Sprinkler • A two-piece Style 15 Recessed Escutcheon with recessed adjust- Identification ment up to 5/8 inch (15,9 mm)from ........,....•:,...-4„... ' - ...:.:c."0- the flush pendent position. Number (SIN) • A two-piece Style 20 Recessed TY313 Upright 5.6K,1/2"NPT ,.. Escutcheon with recessed adjust- TY323 Pendent 5.6K,1/2"NPT ment up to 1/2 inch (12,7 mm)from the flush pendent position. Technical The adjustment provided by the Operation Recessed Escutcheon reduces theData accuracy to which the fixed pipe drops The glass bulb contains a fluid which to the sprinklers must be cut. Approvals expands when exposed to heat.When Intermediate level versions of Series Refer to Table A the rated temperature is reached, the TY-FRB Sprinklers are described in Maximum Working Pressure fluid expands sufficiently to shatter the Technical Data Sheet TFP357. Sprin- 175 psi(12.1 bar) glass bulb, allowing the sprinkler to kler guards and shields are described 250 psi(17.2 bar)* activate and water to flow. in Technical Data Sheet TFP78O. "The maximum working pressure of 250 psi(17.2 bar) Design only applies to the listing by Underwriters Laborato- ries,Inc.(UL). Discharge Coefficient Criteria K=5.6 GPM/psi' (80,6 LPM/bar' ) The TYCO Series TY-FRB,5.6 K-factor, Temperature Rating Upright (TY313) and Pendent (TY323) Refer to Table A Sprinklers are intended for fire protec- IMPORTANT Finishes tion systems designed in accordance Always refer to Technical Data Sprinkler:Refer to Table B with the standard installation rules Sheet TFP700 for the "INSTALLER recognized by the applicable Listing or Recessed Escutcheon:White Coated, WARNING"that provides cautions Black Coated,Chrome Plated,or Brass basedd) agency (such as, UL Listing with respect to handling and instal- Plated is13, ndFMon the requirements o aisbased of on the lation of sprinkler systems and com- ponents. Improper handling and Physical Characteristics requirements of FM's Loss Prevention installation can permanently damage Frame Bronze Data Sheets).Only the Style 15 or Style Button Brass/Copper 20 Recessed Escutcheon is to be used a sprinkler system or its compo nests and cause the sprinkler to fail Sealing Assembly...Stainless Steel w/TEFLON for recessed pendent installations. Bulb to operate in a fire situation or cause nze Compression Screw Bronze it to operate prematurely. Deflector Bronze Page 1 of 4 JULY 2017 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* ' Gi'Fi$ -- / EjTb\ i'-rT1.1Z1�r } I ■R�=5 =l 7/16 (11,1 mm) 1Fc NOMINAL 2" I) 4 R MAKE IN (50,8 mm) /EI fir 2 D. a 1 dm 2" NJ I`V 1 3/8" 3 L ii dm (50,8 mm) Ij (34,9 mm) gi' 7� ` WRENCH 1 3, ¢ / I _ FLATS 1/2"NPT** DEFLECTOR* 2-7/8"(73,0 mm)DIA. - CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE L. Installation Step 2. With pipe-thread sealant applied to the pipe threads, hand- The TYCO Series TY-FRB,5.6 K-factor, tighten the sprinkler into the sprinkler WRENCH RECESS Upright (TY313) and Pendent (TY323) fitting. (USE ONLY Sprinklers must be installed in accor- dance with this section. sprinkler fitting using only the W-Type General Instructions 6 Sprinkler Wrench(Figure 2).With ref- FIGURE2 Do not install any bulb-type sprinkler erence to Figure 1,apply the W-Type 6 W-TYPE 6 if the bulb is cracked or there is a loss Sprinkler Wrench to the wrench flats. SPRINKLER WRENCH of liquid from the bulb.With the sprin- Torque sprinklers 7 to 14 ft.-lbs.(9,5 to kler held horizontally,a small air bubble 19,0 Nm). should be present.The diameter of the Recessed Pendent Sprinklers WRENCH air bubble is approximately 1/16 inch The Series TY-FRB Recessed Pendent RECESS (1,6 mm)for the 135°F(57°C)and 3/32 Sprinklers must be installed in accor- inch(2,4 mm) °F(141°C)tem- dance with the following instructions. � btained by applying a �f perature ratings. /IStep A. After installing the Style 15 A leak-tight 1/2for the inch286 NPT(141 sprinkler or Style 20 Mounting Plate over the joint should be osprinkler threads,and with pipe-thread minimum to maximum torque of 7 to 14 sealant applied to the pipe threads, ., ft.-lbs. (9,5 to 19,0 Nm). Higher levels hand tightensprinkler the sprinkler into the of torque can distort the sprinkler Inlet �'�, with consequent leakage or impairment fitting. PUSH WRENCH of the sprinkler. Step B. Tighten the sprinkler into the IN TO ENSURE sprinkler fitting using only the W-Type ENGAGEMENT Do not attempt to compensate for 7 Recessed Sprinkler Wrench (Figure WITH WRENCHING insufficient adjustment in the Escutch- 3).With reference to Figure 1,apply the WRTHCHINN AREA eon Plate by under- or over-tightening W-Type 7 Recessed Sprinkler Wrench the sprinkler. Re-adjust the position of to the sprinkler wrench flats. Torque FIGURE 3 the sprinkler fitting to suit. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 W--TYPE 7 RECESSED Upright and Pendent Sprinklers Nm). SPRINKLER WRENCH The Series TY FRB Upright and Step C. After ceiling installation and Pendent Sprinklers must be installed finishing, slide on the Style 15 or Style in accordance with the following 20 Closure over the Series TY-FRB instructions. Sprinkler and push the Closure over the Step 1.Install Pendent sprinklers in the Mounting Plate until its flange comes in pendent position. Install upright sprin- contact with the ceiling. klers in the upright position. TFP172 Page 3 of 4 Care and _ 2-7/8" DIA. Maintenance (73,0 mm) 2-1/4" DIA. — The TYCO Series TY-FRB,5.6 K-factor, FACE OF (57,2 mm) Upright (TY313) and Pendent (TY323) SPRINKLER Sprinklers must be maintained and ser- FITTING 5/8"(15,9 mm) viced in accordance with this section. + 1 _ IN FLUSH Before closing a fire protection system 3/s±5/16" �`�`� 1 • main control valve for maintenance (9,5±7,9 mm) , t% j work on the fire protection system } / that it controls, obtain permission to ��� 1/8" shut down the affected fire protection MOUNTING systems from the proper authorities SURFACE (3,2 mm) and notify all personnel who may be r affected by this action. CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) TY-FRB PLATE 3/4"(19,1 mm) Absence of the outer piece of an escutcheon, which is used to cover FIGURE 4 a clearance hole, can delay sprinkler SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) operation in a fire situation. WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 The owner must assure that the sprin RECESSED ESCUTCHEON klers are not used for hanging any objects and that the sprinklers are only 2-7/8"DIA. cleaned by means of gently dusting (73,0 mm) - with a feather duster; otherwise, non- FACE OF operation in the event of a fire or inad- SPRINKLER 2-1/4"DIA. vertent operation may result. FITTING (57,2 mm) - Sprinklers which are found to be 5/16±1/4" leaking or exhibiting visible signs of (7,9±6,4 mm) 1/2"(12,7 mm) corrosion must be replaced. + FLUSHI Automatic sprinklers must never be / 1pained, plated, coated, or other- wise altered after leaving the factory. t / 4—=-1 , Modified sprinklers must be replaced. MOUNTING 1/8" j Sprinklers that have been exposed to SURFACE (3,2 mm) corrosive products of combustion, but have not operated,should be replaced if they cannot be completely cleaned CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) by wiping the sprinkler with a cloth or TY-FRB PLATE 7/8"(22,2 mm) by brushing it with a soft bristle brush. FIGURE 5 Care must be exercised to avoid SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) damage to the sprinklers before, WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 during, and after installation. Sprin- RECESSED ESCUTCHEON klers damaged by dropping, striking, wrench twist/slippage,or the like,must Limited Recessed Escutcheon be replaced. Also, replace any sprin- Specify: Style 15 Recessed Escutch- kler that has a cracked bulb or that has with(specify')finish,P/N(specify*) lost liquid from its bulb. (Ref. Installa- Warranty tion Section.) Specify: Style 20 Recessed Escutch- For warranty terms and conditions,visit eon with(specify*)finish,P/N(specify*) The owner is responsible for the www.tyco-fire.com. inspection,testing,and maintenance of *Refer to Technical Data Sheet TFP770 their fire protection system and devices Sprinkler Wrench in compliance with this document, as Ordering Specify: W-Type 6 Sprinkler Wrench, well as with the applicable standards Procedure P/N 56-000-6-387 of the National Fire Protection Asso Specify: W-Type 7 Sprinkler Wrench, ciation (e.g., NFPA 25), in addition to Contact your local distributor for avail- P/N 56-850-4-001 the standards of any other authorities ability.When placing an order, indicate having jurisdiction.Contact the install- the full product name and Part Number ing contractor or product manufacturer (P/N). with any questions. Automatic sprinkler systems are rec- Sprinkler Assemblies with NPT ommended to be inspected, tested, Spread ConnectionsTY-FRB and maintained by a qualified Inspec- Specify:Pendent (specify)es Upright Ior N tion Service in accordance with local y) K=5.6, QuickSprinkler, SIN requirements and/or national codes. (specify),temperature ag, (specify)Response,) (specify) rating, (specify) finish, P/N (specify, refer to Table A). TFP172 Page 4 of 4 SPRINKLER FINISH(See Note 7) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME FACTOR COLOR BRASS PLATED POLYESTER 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red (TY313) and 175°F(79°C) Yellow 1,2,3,4,5,6 PENDENT 5.6 (TY323) 200°F(93°C) Green 1/2"NPT 286°F(141°C) Blue 135°F(57°C) Orange RECESSED - PENDENT 155°F(68°C) Red (TY313) 175°F(79°C) Yellow 1,2,3,4 Figures 4a and 5b 200°F(93°C) Green Notes: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. VdS Approved(For details,contact TYCO Fire Protective Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-54-428-3377.) 6. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. a. Installed with Style 15(1/2"NPT)5/8"Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only.Listings and approvals apply to color(Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/N* 77 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 370 5.6K UPRIGHT(1/2"NPT) TY313 1 NATURAL BRASS 135 135°F(57°C) 371 5.6K PENDENT(1/2""NPT) TY323 3 PURE WHITE(RAL9010)** ° 155 155°F POLYESTER (68°C) *Use suffix"I"for ISO 7-1 connection; SIGNAL WHITE(RAL9003) for example,77-370-4-175-I 4 POLYESTER 175 175°F(79°C) 5 JET BLACK(RAL9005) POLYESTER 200 200°F(93°C) 9 CHROME PLATED 286 286°F(141°C) **Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2017 Tyco Fire Products,LP. All rights reserved. 'two TEFLON is a registered trademark of DuPont Fire Protection Products Pipe Hangers Fig.200- "Trimline"Adjustable Band Hanger (B-Line Fig.133170NF) ' `r' - C► Fig.200F- "Trimline"Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) U )US Fig.200C - "Trimline"Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTER Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications s Function: For fire sprinkler and other general piping purposes. Knurled --, swivel nut design permits hanger adjustment after installation. Features: • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe �� types and protect CPVC plastic pipe from abrasion. Captured design - 1 keeps adjusting nut from separating with hanger. Hanger is easily o B installed around pipe. For hanger with non-captured nut order Fig. 200S. n • (21/2" (65mm)thru 8" (200mm)) Spring tension on nut holds it securely in ,Y� ,,1' �;_ '' hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) _ in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Fig,Zoo-�/z.200-3/4 Factory Mutual Engineering Approved (FM) (3/4" (20mm)thru 8" (200mm)). Fig.200-1 to 200-2 Fig.2002V2to200-8 Conforms to Federal Specifications WW-H-171 E &A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized. Stainless Steel f materials will be supplied with (2) hex nuts , in place of a knurl nut. " =,,: Order By: Figure number and pipe size -. f Designed to meet or exceed requirements of _. ' FM DS 2-0. T ,. ''' Fig.200 Fig.200C Fig.200E Pipe Size Rod Size A B Approx.WtJ100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) 3/8°-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2' (63.51 11 (5.0) • 200-1 1" (25) 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) a' 200-11/4 11/4" (321 3/8%16 33/4" (94.0) 27/8' (73.0) 13 (5.9) 200-11/2 11/2" ;1401 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) 200-2 2' (501 3/8%16 41/2" (114.31 3" (76.31 15 (6.9) ' 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.31 200-3 3' (751 3/8'-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" 190) 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" 1127.0) 35 (16.0) 200-5 5" (1251 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 112"-13 131/8" (333.4) 83/4" (222.2) 136 (62.31 All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions B-Line 21 by E `C+1