Report (36) FIRE ALARM IMPROVEMENT ' VED SUBMITTAL GUIDE MAY 21 2018 CITY OF TIGARD BUILDING DIVISION TIGARD HIGH SCHOOL ROLL-DN DOOR INTERFACE DETAILS A, B &C 9000 SW DURHAM RD TIGARD, OR 97224 Prepared By: PERFORMANCE SYSTEMS INTEGRATION 7324 SW Durham Road Portland, Oregon 97224 info@psintegrated.com (503) 641-2222 Phone (503)641-1464 Fax 5/18/2018 'RS CCC 61,0 hC 4v Lit-AA vY\ 4 Simplex TrueAlarm® Smoke Detectors UL, ULC, CSFM Listed; FM Approved; TrueAlarm Photoelectric Smoke Detectors MEA (NYC)Acceptance* for Two-Wire and Four-Wire Bases Features Photoelectric smoke detector with on-board TrueAlarm sensitivity drift compensation** , Functional chamber enclosure: f • Louvered design enhances smoke capture by directing flow to chamber 1 ' / " A • Entrance areas are minimally visible when ceiling mounted Multi-function indicator LED indicates normal 4098-9601 TrueAlarm Photoelectric and alarm conditions Detector Mounted in Base Magnetically operated functional test: • Initiates alarm and verifies performance • Identifies general sensitivity status using detector LED Models available in two sensitivity settings: • 4098-9601,Standard Sensitivity,nominal 2.8%/ft S•ecifications obscuration* Voltage 15 to 32 VDC from Fire Alarm • 4098-9605,Special Application Sensitivity,nominal Control Panel IDC 3.5%/ft obscuration Standby Current 100 NA @ 24 VDC Available options: Alarm Current,2-Wire Up to 86 mA maximum,exact • Bases for 2-wire or 4-wire operation Operation current is determined by alarm current limiting of connected IDC • Auxiliary alarm relay output Alarm Current,4-Wire • Remote alarm indicating LED Operation 24 mA typical @ 24 VDC Designed for EMI compatibility AuxiliaryRelayRatings Refer to page 2 under Product 9 Selection UL listed to Standard 268 Air Velocity Range 0-2000 ft/min(0-610 m/min) UL Listed Temp. 32°to 100°F(0°to 38° Range C) Descri•tion Operating Temp. 15°to 122°F(-9°to+50°C) ® Range Simplex®TrueAlarm photoelectric detectors provide many of the proven TrueAlarm analog sensing Humidity Range 10°to RH from 32°to 122°F (0°to 500°°C)non-condensing features for applications where detectors are connected to conventional 2-wire or 4-wire initiating device circuits Color Frost White (IDCs).Each TrueAlarm detector has an on-board 4-7/8"Dia.x 1-7/8"H,mounted in microprocessor that evaluates its photoelectric light Dimensions base(124 mm x 48 mm); refer to scattering chamber activity and makes an intelligent page 3 for detail decision based on light obscuration history as to whether an alarm condition is present. TrueAlarm detectors are packaged in a patented ° ULC listed model is 4098-9601.This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety housing that minimizes the visibility of the air intake Code.See CSFM Listing 7272-0026:219 for allowable values and/or conditions concerning louvers from the normal viewing locations while material presented in this document.It is subject to re-examination,revision,and possible cancellation.Accepted for use—City of New York Department of Buildings—MEA35-93E. maintaining a high performance smoke capture ability**. Additional listings may be applicable;contact your local Simplex product supplier for the Bases are available for remote alarm LED indicator latest status.Listings and approvals under Simplex Time Recorder Co.are the property of connections and auxiliary relay outputs. Tyco Safety Products Westminster. TrueAlarm smoke detector operation is protected by one or more of the following U.S. Patents:5155,468;5173,683;5,400,014;5,543,777;5,710,541;D393,407;D388,352; 0392,573. S4098-0015-6 8/2009 TrueAlarm Smoke Detector Features Application Reference Intelligent Data Evaluation.Conventional smoke detectors will typically drift toward being too sensitive Detector Locations.Locations should be determined due to the accumulation of dust and dirt.With TrueAlarm only after careful consideration of the physical layout and analog detection,data from the photoelectric chamber is contents of the area to be protected.Refer to NFPA 72, monitored and analyzed at the detector to provide a the National Fire Alarm Code.On smooth ceilings, continuously shifting reference point. smoke detector spacing of 30 ft(9.1 m)may be used as a Drift Compensation.The data evaluation and its guide.For detailed installation information,refer to 4098 shifting reference point provide a software filtering Detectors, Sensors, and Bases Application Manual process that compensates for environmental factors(dust, (574-709). dirt,etc.)and component aging,establishing an accurate Sensitivity Selection.The 4098-9601 standard reference for evaluating new activity.With this filtering, sensitivity detector is recommended for most applications. the resulting drift compensation provides a significant When a special application for a reduced sensitivity reduction in the probability of false or nuisance alarms detector is required,the 4098-9605 should be considered. caused by shifts in sensitivity—either up or down. Consult your local Simplex product supplier for Magnetic Test Information.Status information is assistance in determining the proper selection. available by performing the magnetic test and observing the detector LED pulses.The LED will normally go directly into alarm with the magnetic test.If there is an off-normal condition,the LED pulses first to indicate the condition and then goes into alarm.(See page 3.) Product Selection Smoke Detectors Model Nominal Sensitivity Description Compatibility 4098-9601 2.8%/ft(standard) o TrueAlarm Photoelectric Detector Compatible with bases:4098-9788, 4098-9605 3.5/o/ft(special application sensitivity, 4098-9682,and 4098-9683 not ULC listed) Compatible Bases Model Description Details` 4098 9788 2-Wire Base with connections for IDC and LED connections are screw terminals for in/out wiring, Remote Alarm LED Indicator 18 to 14 AWG 4-Wire Base with Auxiliary Alarm Relay Ratings,Single Form"C",For Suppressed Loads: Relay Contacts and connections for Power limited,3 A @ 28 VDC;Non-power limited,3 A @ 120 VAC 4098-9682 Remote LED Alarm Indicator Wiring Connections(In/Out where required): NOTE:Requires external 24 VDC for Relay contacts and IDC wiring,color coded 18 AWG leads; operation LED wiring,screw terminals for 18 to 14 AWG 2-Wire Base with Auxiliary Alarm Relay Ratings,Dual Form"C",For Suppressed Loads: Relay&connections for Remote LED Power limited, 1 A @ 28 VDC;Non-power limited, 1/2 A @ 120 VAC 4098-9683 Indicator NOTE:Must be connected as the only Wiring Connections(In/Out where required): device on the IDC to ensure relay Relay contacts and IDC(-),color coded 18 AWG leads; operation. IDC(+)and LED wiring,screw terminals for 18 to 14 AWG Detector Accessories Model Description Details* Required for mounting to surface mounted 4"(102 mm)square or 4"octagonal boxes,and to 4"square flush mounted boxes 4098-9832 Adapter Plate May be used when retrofitting existing bases Compatible with detector bases 4098-9788,-9682,&-9683 4098-9830 Remote LED Indicator Mounted on single gang stainless steel plate 2098-9739 Encapsulated Dimensions:2-1/2"x 1-1/2"x 1" Required for 4-wire circuits using 24 VDC (64 mm x 38 mm x 25.4 mm) 4098-9682 base,one per circuit;select End-of-Line RelayMounted on single gang mounting type as required;wiring is color 2098-9735 Plate Mountedstainless steel plate coded 18 AWG wire leads *Refer to pages 3 and 4 for dimensions and additional mounting details; 18 AWG=0.82 mm2; 14 AWG=2.08 mm2 2 S4098-0015-6 8/2009 Detector Status LED Indications LED Indication Status Pulses approximately every 4 seconds Normal Steady On Alarm LED Response to Magnetic Test* LED Indication Followed By Status Action LED turns ON Alarm is initiated Normal,sensitivity is within None compensation range LED pulses quickly, More sensitive,out of normal 6 times in 3 seconds, Alarm is initiated compensation range then turns ON Cleaning or other service is required LED pulses slowly, Alarm is initiated Less sensitive,out of normal 4 times in 8 seconds, compensation range then turns ON Does not initiate Alarm Detector is malfunctioning Service is required *Testing requires placing a magnet at the designated location on the detector cover for 4 seconds.Refer to Application Manual 574-709 for further test and maintenance information. Dimensions and Reference Information 1/4" (6.4 mm) _I__I e 6-3/8"(162 mm) II I 4098-9832 Adapter Plate I e 4-7/8"(124 mm) s� ig=M1 Base height 1-7/8„ 11/16" (48 mm) (17 mm) I MUM \ta1 'I'��/�/ LED Status Indicator (with clear lens) 4098-9601 &-9605 Dimensions Mounted on Base ALARM 0 Simplex N 4098-9830 Remote LED Indicator(not to scale) 3 S4098-0015-6 8/2009 Mountin• Information (Electrical boxes are supplied by others.) Electrical Box Requirements: Without relay(base 4098-9788): 4"octagonal or 4"square, 1-1/2"deep Single gang, 2"deep With relay(bases 4098-9682 and 4098-9683): 4"octagonal, 1-1/2"deep,with 1-1/2"extension ring 4"square, 1-1/2"deep,with 1-1/2"extension ring Surface mount reference 4"(102 mm) 4"(102 mm) square box octagonal box 1-1/2"(38 mm) Flush mount reference, mount even with final minimum box depth surface, or with up to 1/4"(6.4 mm)maximum recess 4098-9832 Adapter Plate, required for mounting i to surface mounted boxes and to 4"square flush mount boxes 4098-9682 and 4098-9683 include a relay module that mounts in base electrical box 11111110 Smoke Detector Bases III 4098-9788, 9682,&-9683 womimmp MrEli,_ 96 4098-9601,-9605 Smoke Detector Tyco is a registered trademark of Tyco International Services GmbH and is used under license.Simplex,TrueAlarm,and the Simplex logo are trademarks of Tyco International Ltd and its affiliates and are used under license.NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association(NFPA). Simplex Tyco Safety Products Westminster•Westminster, MA•01441-0001•USA S4098 0015-6 8/2009 a www.tycosafetyproducts usa-wm.com 2009 Tyco Safety Products Westminster.All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. ®Simplex MAPNET II® Communicating Devices UL, ULC, CSFM Listed; Zone Adapter Modules (ZAMs) FM Approved* Addressable Interface to Conventional Circuits Features y, MAPNET II ZAMs provide an addressable interface - ®J ` k. to conventional fire alarm zone circuit devices** Q HMV! r including: €i"F _ - 1 :t.sg . • Initiating devices(Monitor ZAM) 0 wilco a • Notification appliance circuits(Signal ZAM) • Control relays(Control ZAM) 0' These ZAMs are compatible with the following v1 , / Simplex®fire alarm control panels when equipped with MAPNET II communications: \ O ® • 4100/4100U Series fire alarm control panels Signal/Control ZAM • 4100 Series Universal Transponders • 4120 Series Network node fire alarm control panels • 4020 Series fire alarm control panels g )s ) ) C .Sye:q:x • 2120 Communicating Device Transponders ! azogm 2 8. MAPNET II communications can be wired: ' • NFPA Style 4/Class B or Style 6/Class A , o • Style 4/Class B communications may be wired either"T"tapped or In/Out ° Convenient DIP switch address selection @ O 5 UL listed to Standard 864 \ Monitor ZAM Descri•tion MAPNET II zone adapter modules(ZAMs)provide Descri•tion (Continued an addressable interface between conventional zone Control ZAMs provide addressable control functions devices and the host fire alarm control panel. such as elevator capture,HVAC control,pressurization fan control,and damper control.The control relay Monitor ZAMs provide status monitoring and supervision of an initiating device circuit(IDC)zone and provides a DPDT contact(contact ratings are shown on are used for circuits with non-addressable detectors and page 4). for other contact closures such as waterflow and tamper switches or non-addressable manual stations.Different General S•ecifications models of Monitor ZAMs are available for two-wire IDCs Class B,or Class A,and for four-wire IDCs with Class B Communications Supplied by MAPNET II, IDC input.Each type required a separate 24 VDC input 24 to 40 VDC with data power from a listed fire alarm power supply. Power Separate 24 VDC required from listed fire alarm power supply Signal ZAMs supervise and operate 24 VDC notification appliances,speakers,and telephone circuits.Output Wring Information Refer to reference diagrams on pages 3 and 4 capacity is up to 2 A @ 24 VDC,or 50 W of 25 VRMS speakers,or up to three simultaneously activated Wire Connections Screw terminals for in/out wiring, firefighter phones.The signal ZAM is available for either 18 to 12 AWG wire Style Y/Class B or Style Z/Class A operation for Address Means DIP switch,8 position notification appliance circuits. Temperature Range 32°F to 120°F(0°C to 49°C) ' This product has been approved by the California State Fire Marshal(CSFM)pursuant to pintended for indoor operation Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7300-0026:182 for allowable values and/or conditions concerning material presented in this Humidity Range Up to 85%RH at 86°F(30°C) document.It is subject to re-examination,revision,and possible cancellation.Additional listings may be applicable,contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety ** MAPNET II addressable communications are protected by U.S.Patent No. Products Westminster. 4,796,025. S2190-0012-15 5/2010 Product Selection Zone Adapter Modules,Monitor ZAMs(separate 24 VDC power is required) Model Cover Type Description Supervisory Current Alarm Current 2190-9153 Surface Monitor ZAM,Class A(Style D) 2190-9154 Flush 2190-9155 Surface Monitor ZAM,Class B(Style B) 20 mA @ 24 VDC 90 mA @ 24 VDC 2190-9156 Flush 2190-9157 Surface 4-Wire Detector ZAM, Class B IDC input 2190-9158 Flush Zone Adapter Modules,Signal and Control ZAMs(separate 24 VDC power is required) Model Cover Type Description Supervisory Current Alarm Current 2190-9159 Surface Signal ZAM, Class A(Style Z) 15 mA @ 24 VDC 65 mA @ 24 VDC 2190-9160 Flush 2190-9161 Surface Signal ZAM,Class B(Style Y) 15 mA©24 VDC 2190-9162 Flush 40 mA @ 24 VDC 2190-9163 Surface Control Relay ZAM, DPDT Contacts 10 mA @ 24 VDC 2190-9164 Flush T •ical ZAM Mountin• 4-11/16" (119 mm) Square box, 2-1/8" (54 mm)deep \i �V rJ Typical ZAM assembly ( 1 o r 1 rJ r 0 r 1 J I -11-'1 ' 111111 l SC-; J — , atteai ( J o sib p •-__.-- X t ET c______, c_____Th,, l ® 1\ o 4-11/16" (119 mm) o Square extension ring, awl 1-1/2" (54 mm) deep Flush cover, 5-7/16" 1 aSimPlex I O o square (138 mm) Surface cover, 4-15/16" square (125 mm) 2 S2190-0012-15 5/2010 Monitor ZAM Reference Wirin• Dia•ram 24 VDC Monitor • • • Class Style B A ZAM 2-Wire monitor circuit "T Tapped + I MAPNET II // �/ or IN/OUT - wiring - communications / I� Shield Monitor 1111 Monitor V V V circuit circuit A • /// 111 Resettable End of line Return • Detector power • • • _ relay Class A/Style D 4-Wire detector 2-Wire monitor circuit ZAM wiring Si•nal ZAM Wirin• Reference + 011 24 VDC Class B/Style Y ■, notificationappliance circuit(speakers• 'T Tapped or MAPNET IIIN/OUT wiring communications - • Shield Signal input,audio or phone Primary Ma Class A/Style Z notification appliance circuit Return I Signal input,audio or phone 3 S2190-0012-15 5/2010 Control ZAM Reference Wirin• Dia•ram Control ZAM 0 0 N.C.1 24 VDC �I Common 1 O 0 N.O. 1 "T"Tapped or MAPNET II IN/OUT wiring _ communications 0 0 N.C.2 Shield • • • • Common 2 Controlled //5 �0 0 _ device N.O.2 Control Power Control ZAM Rela Ratin•s DPDT Contacts Application Resistive Rating Inductive Rating** Power Limited* 2 A @ 28 VDC 1 A @ 28 VDC 2A@28VDC 1A@28VDC Non-Power Limited 1/2A@120 VAC 1/2A@120 VAC * DC Voltage must be from a listed Fire Alarm power supply. ** Inductive loads must be properly suppressed. Tyco is a registered trademark of Tyco International Services GmbH and is used under license.Simplex,the Simplex logo,and MAPNET 11 are trademarks of Tyco International Ltd and its affiliates and are used under license. ®Simplex Tyco Safety Products Wewww.tycosafetyproducts-usa-wm.tminster•Westminster, com01441-0001•USA S2190-0012-15 5/2010 ©2010 Tyco Safety Products Westminster.All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice.