Loading...
Permit (66) CITY OF TIGARD MASTER PERMIT IN I COMMUNITY DEVELOPMENT Permit#: MST2018-00141 and OR 97223 503.718.2439 13125 SW Hall Blvd.,Ti Date Issued: 05/31/2018 Tft�Al-:i7 9 Parcel: 2S109DB07600 Jurisdiction: Tigard Site address: 13020 SW KOSTEL LN Subdivision: SUMMIT RIDGE NO.5 Lot: 144 Project: GANDHINATHAN Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $8,074.31 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof Top PV System Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: GANDHINATHAN,SIDDHARTH BLUE RAVEN SOLAR LLC Required Items and Reports(Conditions) PALANIAPPAN,ARUNA 1220 S 630 EAST,STE 430 13020 SW KOSTEL LN AMERICAN FORK,UT 84003 TIGARD,OR 97224 PHONE: PHONE: 385-498-4408 FAX: Total Fees: $321.88 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other -pp -'.le law. work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if w• is - s.- •r or more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center i.• e i re set forth in OAR 952-001-0010 through 0A;- 001-0090. Yo. may obtain a cop of the rules or direct questions to OUNC by calling 503.2.3"i !: • /$s 344. -4 1 /ice _ -- ,„-' _Adidri Issued By: ''1 � ,Al LI/ - Permittee rgnature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date.I " This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential FOR OFFICE L:SE ONLY City of Tigard RECEIVED Received . Date/By: 7 877— II Permit No.:�S%ys �/ ` 13125 SW Hall Blvd.,Tigard,OR 97223 nqp Plan �J"LJ _ Phone: 503.718.2439 Fax: 503.598.1960 i 0 .Z U 1 O p Other Permit: DateBy: Z T 1 C ARD Inspection Line: 503.639.4175 MAY Date Ready/By. Jaris: ® See Page 2 for Internet: www.tigard-or.gov 1.t Ye OF TIG NIL) Not ethod: . �'!n Supplemental Information �ima :, `. . 4 :: s .,.q r„te.-i a � •t7 .rr ¢ ltd `i dal • itai�xtgei r, le .g.ii. I r ` ! f � ir r x. _ ,e.. 4 . s . 1:... � . n._,s , . _i ,, a. .. , .... ,, , ,« . ». .3 ,,.,_te . .,:.i Permit fees*are based on the value of the work performed. ❑New construction ❑Demolition Indicate the value(rounded to the nearest dollar)of all 0 Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the TI WWtx r �,. - PAS 1. . +r.xa - ` work indicated on this application. El 1-and 2-family dwelling 0 Commercial/industrial Valuation: $$,074.31 1::Accessory building ❑Multi-family Number of bedrooms: ,. ❑Master builder 0 Other: Number of bathrooms: a •• tt` ,,rt„”•,4 554, as• eta• l'a tiq i i r'o ''-+ . Total number of floors: Job site address:13020 SW Kostel Ln New dwelling area: square feet City/State/ZIP:Tigard, OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Gandhinathan 3.48kw Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet tri: A q;':i4 47 " E�t2a°i4 @ 'i % �. cit# / In Subdivision:CP04b Bull Mtn "" •' ••' i '•., Lot no.:R2195188 Permit fees*are based on the value of the work performed. Tax map/parcel no.:2S109DB07600 Indicate the value(rounded to the nearest dollar)of all 4 � a equipment,materials,labor,overhead,and the profit for the '• g"` 7 r• , V v i, `; •' i itt� ,'t ' , 4 . • t fi'""�< work indicated on this application. Rooftop solar PV 3.48kw Valuation: $ Existing building area: square feet New building area: square feet S1m Y^ 74 Illirnw"�`.'t ,1.ta � 7�.tal�aiir '.n tip ; ir' : 1 14s` , tm� `i rt'`'�.•..1"'"x: Number of stories: Name:Siddharth Gandhinathan Type of construction: Address:13020 SW Kostel Ln Occupancy p y groups: City/State/ZIP:Tigard, OR 97224 Existing: Phone:( ) Fax:( ) �•�. ,���.'-r=�'t,:�. .. ��, New: ,tar VI-:7.1.,•:. . :. 4 t ;.:e..„ :t.-3'at iift •? ..x'r. e«x® lifint i.'.'-..4I 'a,ni•.».'c :'�,Sci v: �RX,„,.�' 1-'4.:77:17i .. , a«'w -i,....,.,..-mr,•»•,,.«..,?ra••'»•,..L,. rr°.s«.3:....,::fu,^^�,�,,a,.«. .. •..e.• .,... ..� -,i.. -'7'5'7 '''n'41;+4"'''''°' .sib'Ka n.:�':.' �";`:� �.�' J �6,: •G •a, i Business name: Blue Raven Solar r,,,.,i d: . .. , r, x ' Contact name: Tara Mount Structural plan review fee(or deposit): Address: 1220 S 630 E STE 430 FLS plan review fee(if applicable): rican Fork,UT 84003 City/State/ZIP: AmeTotal fees due upon application: Phone:(385) 482-0045 I Fax::( ) Amount received Email permitting.department@blueravensolar.com '' O t j int c tlfr gig„ �sr rte, '' .:i� , � 13t• .,. _,, _sem-:-• -•-• �=•_.>�`:� :.: . .s?=�'«:'�«=°���t Commercial and residential prescriptive - - _. a I 'i;•.-44-'4. .. ;: . °1•a i• st, } t •: `s ig nra;- amtm p installation of •- _=' :i==;i• =w ctmh v x1€ :• roof-top mounted Photovoltaic Solar Panel System. Business name: Blue Raven Solar Submit two(2)sets of roof plan with connection details Address: 1220 S 630E and fire department access,along with the 2010 Oregon Solar Installation Specialty Code checklist. City/State/ZIP: American Fork,UT,84003 Permit Fee(includes plan review $180.00 Phone:( ) Fax:( ) and administrative fees): State surcharge(12%of permit fee): $21.60 CCB lie.: #210112 Total fee due upon application: $201.60 Authorized signature: )4 V {_ ' This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Jeffery Lee Date:5/4/2018 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Building Permit Application Checklist One- and Two-Family Dwelling FOR OFFICE USE ONLY • City of Tigard Received Associatedlig Permit No.: 13125 SW Hall Blvd.,Tigard,OR 97223 Y` _ Phone: 503.718.2439 Fax: 503.598.1960 permits: T I G A K p 24-Hour Inspection Line: 503.639.4175 0 Electrical 0 Plumbing 0 Mechanical Internet: www.tigard-or.gov ❑ Other: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. 0 0 0 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ ❑ ❑ 3 Verification of approved plat/lot. 0 0 0 4 Fire district approval required. Name of district: • ❑ 0 ❑ 5 Septic system permit or authorization for remodel. Existing system capacity ❑ ❑ ❑ 6 Sewer permit. ❑ 0 0 7 Water district approval. ❑ ❑ ❑ 8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ 0 ❑ 9 Erosion control 0 plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ 0 ❑ basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ❑ ❑ 0 building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if 0 ❑ 0 there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ 0 ❑ and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ ❑ 0 furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- 0 ❑ 0 floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ 0 0 Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- 0 ❑ ❑ prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing 0 0 0 locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ 0 ❑ systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. ❑ ❑ 0 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ p ❑ for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or 0 0 0 architect licensed in Ore•on and shall be shown to be as.licable to the .ro'ect under review. JURISDICTIONAL SPECIFICS 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 0 0 ❑ 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ❑ ❑ ❑ 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. 0 ❑ ❑ 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. 0 ❑ ❑ 27 "Drawn to scale"indicates standard architect or engineer scale. ❑ 0 ❑ 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ 0 0 Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, 0 ❑ 0 and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 ❑ 0 including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application RECEIVE �� � FOR OFFICE USE ONLY CityofTigard Received g Date By: Permit#: "t 13125 SW Hall Blvd.,Tigard,OR 97223 MAY 1 0 2018 plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit#: Inspection Line: 503.639.4175 Read Date/B : Jurist TICAPD CITY OF Y YSee®Supplemental Internet www t1 and or. ov Notified/Method S tal I f t g g men Information xe :• x t ■ �o \ ■ �6\� uPP e ❑New construction Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): 0 Demolition 11 Other: ❑Service or feeder 400 amps or more 0 Building over three stories. where the available fault current 0 Marinas and boatyards. .i, '�-c1. ....� {° �Il �i t!'sn 1 y-• ..:r. .: ,.__ exceeds 10,000 amps at 150 volts or 0 Floating buildings. ❑■ 1-and 2-family dwelling ❑Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural amps for all other installations. buildings. 0 Multi-family 0 Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or - v - ua..c�.:.._ f�a _3 ❑Einer enc system. larger separately derived 0 Addition of new motor load of system. Job#: Job site address:13020 SW Kostel Ln 100HP or more. ❑°`A", °E","1-2", `1-3", 0 Six or more residential units. occupancy. City/State/ZIP:Tigard, OR 972240Recreational vehicle IDHealth-carefacilities. parks. Suite/bldg./apt.#: Project name:Gandhinathan 3.48kw 0 Hazardous locations. ❑Supply voltage for more than 60 0 Service or feeder Cross street/directions to job site: amps or more. 600 volts nominal. Ng Description Qty. Each Total * New residential single-or multi-family dwelling unit. Subdivision:CPO4b Bull Mtn Lot#:R2195188 Includes attached garage. Tax map/parcel#:2S109DB07600 1,000 sq.ft.or less 168.54 4 Ea.add'l 500 sq.ft.or portion 33.92 1 E?�..�t. _.. `ey.. L: °` k' ,`k •' 9� `t. ° 1' ! 4�.! t!A 4 - 6 • E 4" .{ •-' ••-;� ... �® :••;... �.::' .r ,•. " ,;i; Limited energy,residential (with above s ft. 75.00 2 Rooftop solar PV 3.48kw q ) Limited energy,multi-family 75.00 2 residential(with above sq.ft.) ;11- RenewableServicesor Ener '' ` """'''!`lam`''a' � W ' 5 � .'i feeders installation,alteration,and/or relocation Name:Ed Elkins 200 amps or less 100.70 2 Address:16692 SW Jordan Way 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard, OR 97224 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email:elkins1119@comcast.net relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 ! -"'• Branch circuits-new,alteration,or extension,per panel ::rH -'1 A.Fee for branch circuits with Business name: Blue Raven Solar above service or feeder fee, 7.42 2 Tara Mount each branch circuit Contact name: B.Fee for branch circuits without Address: 1220 S 630 E STE 430 service or feeder fee,first 56.18 2 branch circuit City/State/ZIP: American Fork,UT,84003 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(385 482-0045 I Fax: : ( ) Each manufactured or modular 67.84 2 ermittin de artment dwelling,service and/or feeder Email: P g blueravensolar.com P @ t .-.�-. ,x:• Reconnect only 67.84 2_ �-,:�_ a " .4,7k �_ "� RNa a517: Pump or irrigation circle 67.84 2 Business name: Blue Raven Solar Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address: 1220 S 630 E STE 430 0 See Page 2 2panel,alteration,or extension. City/State/ZIP: American Fork,UT.84003 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:( 385)482-0045 Fax: ( ) Investigation(1 hr min) 90.00/hr Email: permitting.department@blueravensolar.com S .lc r, Industrial plant(1 hr min) 78.18/hr 4 Inspections for which no fee is CCB Lic.: 210112 Electrical Lic.: C1214 Suprv.Lic.:"61397S specifically listed 'h hr min 90.00/hr Suprv.Electrician signature,required: / Subtotal: Print name: Sam Collier I Date: 5/4/2018 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Ben Wade Date:5/4/2018 days after it has been accepted as complete. * Number of inspections allowed per permit. C\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: ..._:::; ._ ^+..n ._..a .,:'r. .,..r_.:e•. E:i.... •y ,."ui sem- : % . .. ":r"......:EEEnE`e?SfE ..nl 'iiE? :,;E„ .i„• :»aW;.v_ nv:b 'P. a:: 8 :2?f i� :: •a...:ir.:_...a. ...:it ..v r.a,;.». «n•..: j"i..2'.;•y:.::m:: a ¢gip r.E;•[r:n;;nEr • ryy gggg „ .. :�.. .,... ..#� �•;.. ., Y S ...E:�:. ,..�. ia• .`t-N 4�.vt�t H.l�3. ..�� _^. � ..#B +� a:,: 9 {., $::: ':. :a:.;,•;:..r.::mE;;?� �(µ6 .,lE...roil Mgt m�1 .�C.. ^:,.. r., �.>6M Description I Qty. Each Total Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed V2 hr min '•• ,*.. :.« - _.� �_. f r�'EE•' _s.;::» .,.a,r. #. $fes" .' :1 :::1 1 ...... ..... a, .. ... R.i ,..a.:.,.Si:3'e:F's6EE:: Su Fee for each commercial system: $75.00 allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 • City of Tigard ' Building Division 13125 SW Hall Blvd, Tigard, OR 97223VEll Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.63 9.4175 18 www.tigard-or.gov CITY OF TIGARD 31 11.DtNG DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 13020 SW Kostel Ln City: Tigard Zip: 97224 Owner's Name: Siddharth Gandhinathan Date: 5/4/2018 Contractor's Name: Blue Raven Solar CCB #: 210112 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation 11] Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? El No OSSC or ORSC for design requirements. Is the wind exposure ❑� Yes Wind Exposure p If"Yes", qualifies for "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ❑■ Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for above 0 Yes the prescriptive path. ❑ No 1 I:Building/Forms/Photovoltaic-Checklist.docx Is the construction material wood and does ID Yes Type of If"Yes", qualifies for the construction qualify Construction as "conventional light ElNo the prescriptive path. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ❑■ Yes the prescriptive path. ❑ No Is the combined weight ❑■ Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ❑■ Yes with Section 305.4(3) of If"Yes", qualifies for ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is RoofingCheck type ❑ of wood the of one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. of composition shingle. Is the roof mounted ❑l Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/Photovoltaic-Checklist.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for El Yes the prescriptive path. 1111 No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for El Yes the prescriptive path. Ill No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directl to inches inches, qualifies for the Y Maximum 60 inches prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of Yes If"Yes", qualifies for fastener? El prescriptive path. 111 No Is the roof decking of WSP min. '/2"thickness, El Yes decking connected to If"Yes", qualifies for framing members El No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ❑� Yes the prescriptive path. surface. El No 3 I:Building/Forms/Photovoltaic-checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer:Solar World Model Number:Sunmodule Plus SW 290M Black Listing Agency:CSA 4 I:Building/Forms/Photovoltaic-Checklist.docx City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 13020 SW KOSTEL LN, TIGARD, OR, 97224 Record Type: Record ID: Residential - Master Permit MST2018-00141 Inspection Type: Inspector: 299 Final inspection Jeff Grove Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 13020 SW KOSTEL LN, TIGARD, OR, 97224 Record Type: Record ID: Residential - Master Permit MST2018-00141 Inspection Type: Inspector: 199 Electrical final Jeff Grove Result: PASS Comments: Violation Summary: Inspector Contractor