PFI2018-00071 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
• COMMUNITY DEVELOPMENT Permit#: PF12018-00071
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 04/17/2018
Parcel: SEG1170
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: Comcast
Project Description: SEG1170, associated with 12805 SW 77th PI,Tigard, OR. From utility pole#NT/36471 bore to place (1)
-2"conduit containing .625"coax a minimum of 36"below grade 129'to utility pole#839/NT.
Owner: FEES
Description Date Amount
PFI Permit Fee 04/02/2018 $300.00
PHONE:
Contractor:
PHONE:
FAX:
Applicant:
ALEX SILANTIEV
11308 SW 68TH PARKWAY
TIGARD, OR 97223
PHONE: 503-941-8656
Total $300.00
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant I I
Signature: ��� e1 y12U
Issued By:
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12018-00071
Type: Condition Name: Status: Severity:
PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the
City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized
by the City Engineer.
PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987.
If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole
before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at
the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work
with affected utility agencies.
PFI_Utilities 14-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by
the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert
Phone#>, to establish a preconstruction meeting.
PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged
inspection, and after completing work covered by the permit.
Contact Ken Fisher at 503 816 6146 or Kenny@tigard-or.gov
PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 19-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing, the names and 24 hour emergency telephone number of two(2) persons who have
authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI_Utilities 21 -OTHER Applied Notice
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of
any agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited
and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up
and suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes,etc. shall be
reinstalled or replaced,with like kind of material. Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition, American Traffic Safety Services
Association [ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work
area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be
effectively maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and
area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire& Rescue)and to 503-962-8140(Tri-Met)
and 503-431-2345(Tigard School District)and other service providers impacted by such closure.
PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
RECEIVED
City of Tigard MAR 2 12018
g
a PUBLIC WORKS —ENGINEERING
CITY OF TIGARD
G PLANNIIAG/ENGINEERING
Public FacilityImprovement (PFI)
TYPE OF WORK
DESCRIPTION OF WORK(in the right-of-way)
8 TYPE 1—Franchise Unlit}'Work i
Check one: R Utilities ❑Sidewalk/driveway approach ❑Street improvements performed by NWN, PGE j
Detailed description: From utility pole#NT/36471 bore to place and/or utility agency.
(1)-2"conduit containing.625"coax a minimum of 36"below grade 129'to ❑ TYPE 2—Sidewalk/Driveway/Sewer
utility pole#839/NT.
Work performed for the purpose of-
-
f• Sidewalk installation or repair. j
• Driveway approach installation
12805 SW 77th PI,Tigard, OR 97223
Property address/location(s): and/or repair
E6 113-0 • Sanitary sewer lateral installation
and/or main line tap
Applicant: Comcast El TYPE 3—Full scale Development
pP Work performed with Land use
Address: 11308 SW 68th Parkway approval which includes any of
City/state: Tigard, OR Zip: 97223 the following.
503 941-8656 Alexander_Silantiev comcast.com • Subdivisions or Partitions
1 hone: ( ) Email: Silantiev@comcast.com
Silantiev 503 941-8656 • Street widening
Contact name: Phone: ( )
• Alainline installation for Sanitary
Contractor:
Texstar Enterprises sewer, Storm sewer,Tigard water
and/or Tigard Water Service Area
CCB#: 178798 Expiration: 10/10/2019
Address: 14122 Arndt Rd, SUBMIT COMPLETED APPLICATION TO:
City/state: Aurora,OR Zip: 97002 City of Tigard
Phone: (503)793-3109 Email: jim.miner@texstarenterprises.com Planning/Engineet ng
13125 SW Hall Blvd.
Contact name: Jim Miner Phone: (503)793-3109 Tigard,OR 97223
Applications for"minor work in right-of-way"
Engineer: K&B Technical Solutions only may be emailed to:
g rowpermitsa.tigard-or.gov
Address: 6566 SE Lake Rd Suite F
City/state: Milwaukie,OR Zip. 97222 iff]tam FAI a at=MENNi1
Phone: (503)650-6041 x217 Email: KJ—Sprecher@kbmail.net Case No.: fFizr�"'—000
Contact name: KJ Sprecher Application submittal fee: $ dO Oo
Additional fees: $
Estimated value of work is required(if over$5,000):$ Application accepted:
(within the public right-of-way) By: 'SC Date: 3`Z
Application reviewed:
Is work related to a LAND-USE DECISION? ❑ Yes ® No
By: � ate: 3" 3 d'^/�
If so,please specify(MLP,SDR,SUB,etc.) case#:
Applicant notified:
Is work related to a BUILDING PERMIT? ❑ Yes R No By: Date: Z
If so,please specify(BUILDING PERMIT)case#: I.\ENG\PermkApplications\pft applkatlon Rev.12/16/2016
_.
,.....;:7&.+sua�.w's,'L'�_:A:i:.t:er4C+e-.t�".s:
t�1t-4d A Cv !(ti-c--raft W t*.A: f.ka
Y
City of Tigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 xvw .tigard-or.gov 503-718-2421 Page 1 of 4
I?A. YZ_A—?
jk g t.t rt5,0+4 .So 3
APPLICANTS
NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if
required by the city pursuant to TMC 15.041.140.
* With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different
people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the
owner. The owner(s)must sign this application in the space provided or submit a written authorization with this application. Franchised
Utilities are not required to obtain the owner's signature on the application
BY SIGNING BELOW,THE APPLICANTS) SHALL CERTIFY THAT:
• The above request does not violate any recorded deed restrictions that may be attached to or unposed upon the subject
propeiu-
• If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
• All of the above statements and the statements in any plot plan,attaclunents,and exhibits transmitted herewith,are true;and
the applicants so acknowledge that any permit issued,based on tivs application,may be revoked if it is found that any such
statements are false.
• The applicant has read the entire contents of the application,including the policies and criteria,and understands the
requirements for approving or denying the application.
k
KJ Sprecher 03/19/2018
Applicant/Authorized Agent's signature Print name Date
SIGNATURES of each owner of the subject property,if required.
Owner's signature Print name Date
Owner's signature Print name Date
Owner's signature Print name Date
PUBLIC FACILITY IMPROVEMENT PERMIT
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • ,vunvtigard-or.gov 503-718-2421 • Page 2 of 4
N
I
wE 0
o io so
p
H
Ja N LU
SCALE:1*-20' � 2 0'
�M ww,
�CC 4')C)(L'
W U)ip toZ�
1— U)< wp
N0 Q'
~ O O'
a "LL
0
4
z
r`
10'FROM FOC
2'FROM ROW
BEGIN UNDERGROUND CONSTRUCTION AT
EXISTING UTILITY POLE IN CITY OF TIGARD ROW
ii
I/ NN3
FOC 4'S,yv � NT/36471 ii 3
PIS 8•25 I FFFF�
I
b 8
BORE TO PLACE(1)-2'CONDUIT A MIN.OF 36" m
BELOW GRADE
12' ' o
1
•1?g. ?0i'' END UNDERGROUND CONSTRUCTION AT a
� EXISTING UTILITY POLE IN CITY OF TIGARD ROW
F / / r �
O-...
60' ` 839INT 10'FROM FOC e,w
W 36' �•25/ [r-�
/ T FROM ROW w O w
W
NUNZIKF _ N
1✓- -___ \35 34' S41,
m0 w
12' FOC 4' _ o
l '\FO 5 AiS
\`` k o
C OD R
W Fn E U
U
1.ALL WORK AREAS TO BE ° o
—`` RESTORED TO LIKE OR BETTER Q .>
CONDITION. "
md�o
Oo °u
FOS, 2.ALL OTHER UTILITIES ARE BASED U U d X1
OFF EXISTING LOCATES OR UTILITY Q
STRUCTURES,
8011, 3.IT IS THE CONSTRUCTION "E
CONTRACTORS RESPONSIBILITY TO RP
CALL FOR LOCATES BEFORE
DIGGING.
•w•M.Y..aM•u►Yi�•
4.BORE/DRILL-
rrwa�.rsar.F
CMEX-10839-7896
Page 52 2011 Edition
Bicycle and Pedestrian Accommodation Diagrams
The following practices and details address the accommodation of bicycles
and pedestrians within work zones. The following detail drawings should be
incorporated, where appropriate, into the traffic control plan for any short
term work.
1. See Section 1.6—Bicycle and Pedestrian Considerations for additional
guidance.
2. Stay alert for pedestrians and bicycle traffic and accommodate safe
passage for them, as needed.
3. The work space should be protected from bicycle and pedestrian
intrusion by using barricades or closely-spaced channelizing devices.
4. Maintain access to transit stops or clearly close a transit stop using
barricades or channelizing devices.
Bicycle Accommodation Diagram 5-6
Bicycle Accommodation Principles:
1. If a significant volume of bicycles can be expected and work closes a
marked bicycle facility, or requires bicycles to share a travel lane,
install a"(Bicycle) ON ROADWAY" sign (CW11-1)or the Bicycle
symbol (W11-1) sign with an "ON ROADWAY" (OBW1-5) rider, in
advance of the work area.
2. Install temporary signing off the paved shoulder, within the planter
(buffer)strip, or share the width needed between the shoulder and the
sidewalk, as available.
3. Signs are to remain in place until the surface is restored and the width
made available for bicycle use. See Diagram 5-6 for typical bicycle
signing placement.
Sign Spacing and Buffer Lengths(feet)
• Posted Spacing Between Signs "Buffer"
Speed A B C Space
20 SO
25 100 100 100 75
30 100
35 350 3S0 350 125
40 150
45 180
50 S00 500 500 210
55 250
60285
65 700 700 700 325
70 365
Chapter 5 September 2016
2011 Edition Page 53
Bicycle Accommodation Diagram 5-6
i
NOTES:
• Bicycles on Roadway(CW11-1)sign should not
interrupt standard sequences. For example:
I
o BE PREPARED TO STOP/Flagger Symbol
o LANE CLOSED AHEAD/Lane Ends
I Symbol
Bicycles on Roadway sign typically follows ROAD
I
WORK AHEAD sign and used as general warning.
I
I
I
I
Tt
I I
I I
I I A
I I
I I
I I
I I�I I
I I
I I
I I
I I A
I I
I I I
I I
I I
I�
I I •
I I I
I
B
I I
I I
I I
1 I� ON
I ROADWAY
I I
I I
I I C
I
I I ROAD
I I WORK
I I ` AHEAD
September 2016 Chapter 5
Page 54 2011 Edition
Pedestrian Accommodation Diagrams
See Diagrams 5-7 and 5-8, below, for pedestrian accommodations in work
zones.
Pedestrian Accommodation Principles:
1. If the work impacts the sidewalk or pedestrian facility, provide a safe,
accessible path, where practical, in accordance with the requirements
of the ADA.
2. If not practical to match the width of the existing pedestrian facilities,
maintain a 4-ft minimum width.
3. Unless a reasonably safe route can be provided through the work
space, pedestrians should be appropriately directed with advance
signing to cross the road. Do not divert pedestrians into travel lanes.
4. Install pedestrian closure or detour signing on Type II barricades.
Make every practical effort to satisfy the following:
• If work closes a sidewalk or sidewalk ramp, close sidewalks at a point
where an alternate crossing point or route can be provided. Minimize
the amount of out-of-direction travel for pedestrians.
• Use a combination of"SIDEWALK CLOSED" (R9-9), "SIDEWALK
CLOSED USE OTHER SIDE" (R9-10), "SIDEWALK CLOSED AHEAD
CROSS HERE" (R9-11), and "SIDEWALK CLOSED CROSS HERE"
(R9-11 a) signing to direct pedestrians to an alternate facility.
• Where there are business destinations between the nearest crosswalk
and the work area, close the sidewalk at the business access nearest
the work area, where practical using the SIDEWALK CLOSED sign.
Include the SIDEWALK CLOSED AHEAD CROSS HERE sign at the
• nearest crosswalk prior to the closure.
Chapter 5 September 2016
2011 Edition Page 55
Pedestrian Accommodation, Mid-Block Diagram 5-7
The sidewalk should be closed at the nearest intersection on each side of the
work area when a safe, ADA-compliant path through the work area is not
available.
SIDEWALK CLOSED
SIDEWALK CLOSED
-♦ or AHEAD
CROSS HERE
CROSS HERE
24x12
Type"W1 24x18
— — (Mount on B(II)L) Type W"
I=T .
SIDEWALK
CLOSED
24x12
Type.W1
(Mount on B(II)LR)
(2 Reqd.)
\...\.. SIDEWALK CLOSED SIDEWALK CLOSER
44— or AHEAD
CROSS HERE ~-
- --- CROSS HERE
24x12 24x18
TYpe'W1" Type"W1
(Mount on B(II)R)
September 2016 Chapter 5
Page 80 2011 Edition
5.3 Two-Lane, Two-Way Roads
Shoulder Work wl Minor Road Encroachment Diag. 300
Use this detail for non-freeway work which extends into a travel lane and
maintains a minimum 10 foot travel lane. If a minimum 10 foot travel lane
cannot be maintained, or when traffic cannot safely pass by in both lanes
simultaneously, use the appropriate lane closure diagrams—for example,
Diagrams 310 through 350.
A lane closure may be appropriate for conditions such as high traffic
volumes, high speeds, and inadequate approach sight distance to the work
space, or heavy equipment adjacent to the travel lane.
1. Use truck-mounted flashing warning lights on work and protection
vehicles. See Section 4.3— Lights and Lighted Signs for exceptions.
2. For added visibility, a truck-mounted arrow board or PCMS in caution
mode may be used.
3. Cones shall be placed along the entire length of the work space. If a
protection vehicle is used and work is in place one hour or less, the
taper and tangent devices may be omitted.
4. If the speed is 45 mph or higher, volumes exceed 2000 ADT, or there
is limited sight distance, consider placing cones or tubular markers on
centerline.
5. An arrow board in caution mode or truck-mounted PCMS with
"SHOULDER WORK" or other appropriate message may be used for
higher visibility.
Sign Spacing and Buffer Lengths(feet)
Posted Spacing Between Signs "Buffer"
Speed A B C Space
20 50
25 100 100 100 75
30 100
35 350 350 350 125
40 150
45 180
50 500 500 500 210
55 250
60 285
65 700 700 700 325
70 365
Chapter 5 September 2016
2011 Edition Page 81
Shoulder Work w/ Minor Road Encroachment Diag. 300
ROAD
WORK `*� t
•
AHEAD I
•
Initial
Warning A •
Sign
•
•
•
(Optional) •
Protection Vehicle
w/TMA(both Optional)
See Chapter 4 • Buffer
10'
minimum • U3
•
A
ROAD
NARROWS
(Optional)
B
ROAD
1 � WORK
AHEAD
Initial
Warning
Sign
September 2016 Chapter 5