Loading...
Report (2) -F/ i osL- 42 72-- ., _ ,,., --‘.-::- --- - y REGH V t l''' APR ;-) Z018 UILDNG 'JSON FN CITY OF B11! cli, ...PK% ., i a : .. •., ''., W yrAT T FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 PBC 196-16505 SPEC OFFICE 7 16505 SW 72ND AVE PORTLAND, OR 97224 FIRE PROTECTION EQUIPMENTSUBMITTAL tyro Fire Protection Worldwide Contacts www.tyco-fire.com Products Series TY-B, 5,6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General NOTICE The Series TY-B Sprinklers described "a x_ Description herein must be installed and maintained The TYCO Series TY B, 5.6 K-factor, in compliance with this document, as " well as with the applicable standards Upright(TY315)and Pendent(TY325) of the National Fire Protection Associa- Sprinklers described in this data sheet tion,in addition to the standards of any are standard response,standard cover- "` .. other authorities having jurisdiction. ,. age,decorative 5 mm glass bulb type Failure to do so mayimpair the erfor- _ $ spray sprinklers designed for use in mance of these devices. p light, ordinary, or extra hazard, com- The owner is responsible for maintain mercial occupancies such as banks, hotels, shopping malls, factories, 9 protection system and pP� 9 in their fire refineries,and chemical plants. devices in proper operating condition. The installing contractor or sprinkler The recessed version of the Series TY-B Pendent Sprinkler, where appli- manufacturerunshould be contacted with any questions. , cable,is intended for use in areas with a finished ceiling.This recessed pendent �+ sprinkler uses one of the following: Sprinkler .-, • A two-piece Style 15 Recessed .-4 Escutcheon with recessed adjust- Identification Y : ment upto5/8inch (15,9mm) from ' the flush pendent cosition. Numbers (S/Ns) " • A two-piece Style 20 Recessed TY315 Upright 5.6K, 1/2"NPT -OrEscutcheon with recessed adjust- TY325 Pendent 5.6K, 1/2-NPT ', ment up to 1/2 inch (12,7 mm)from the flush pendent position. Technical The adjustment provided by the Data Temperature Ratings Recessed Escutcheon reduces the 135°F(57°C) accuracy to which the fixed pipe drops 155°F(68°C) to the sprinklers must be cut. Approvals 175°F(79°C) Intermediate level versions of Series UL and C-UL Listed 200°F(93°C) TY-B Sprinklers are descrf Se in FM, LPCB,and VdS Approved 286°F(141°C) Technical Data Sheet TFP352.Sprinkler CE Certified 360°F(182°C)t guards and shields are described in Sprinklers with Polyester Finish are t UL,C-UL,and VdS Approved only Technical Data Sheet TFP780. UL and C-UL Listed as Corrosion- Resistant Sprinklers. Finishes Sprinkler: Refer to Table A Maximum Working Pressure Recessed Escutcheon:White Coated, 175 psi(12.1 bar) 250 psi(17.2 bar)* Chrome Plated,or Brass Plated The maximum working pressure of 250 psi Physical Characteristics (17.2 bar)only applies to the listing by Un- Frame Bronze IMPORTANT derwriters Laboratories,Inc.(UL). Button Brass/Copper Always refer to Technical Data Sheet TFP700 for the `INSTALLER Discharge Coefficient Sealing Assembly Stainless WARNING" that provides cau- K=5.6 GPM/psi-I/2(80,6 LPM/barli2) Steel w/TEFLON tions with respect to handling and Bulb Glass installation of sprinkler systems and Compression Screw Bronze components.Improper handling and Deflector Bronze installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP152 TFP152 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* c�njE rr u\ ' YlrrrY^i 1��-% I 5 '•I 7/16" ��� (11,1 mm) mr 4 NOMINAL Li MAKE-IN (50,8 mm) ) �,, 2 r `i 0 2" \O_______0/ 1-3/8" - 3 L (50,8 mm) + (34,9 mm) J ( `� 7, WRENCH 1 �' / FLATS 1/2"NPT** DEFLECTOR* -- 2-7/8"(73,0 mm)DIA. - CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE L. Operation Installation WRENCH RECESS The glass bulb contains a fluid which The TYCO Series TY-B, 5.6 K-factor, expands when exposed to heat.When Upright(TY315)and Pendent(TY325) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- ^ END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to FIGURE 2 activate and water to flow. Genera!Instructions W-TYPE 6 Do not install any bulb type sprinkler if SPRINKLER WRENCH the bulb is cracked or there is a loss of esign liquid from the bulb.With the sprinkler Criteria held horizontally, a small air bubble WRENCH should be present.The diameter of the RECESS The TYCO Series TY-B, 5.6 K-factor, air bubble is approximately 1/16 inch Upright(TY315)and Pendent(TY325) (1,6 mm) for the 135°F (57°C) to 3/32 S inch (2,4 mm) for the 360°F (182°C) lo,>r Sprinklers are intended for fire protec /i tion systems designed in accordance temperature ratings. twith the standard installation rules A leak tight 1/2 inch NPT sprinkler recognized by the applicable Listing joint should be obtained by applying a or Approval agency (e.g., UL Listing minimum-to-maximum torque of 7 to 14 is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels iii' 13, and FM Approval is based on the of torque may distort the sprinkler inlet PUSH WRENCH requirements of the FM Loss Preven- and cause leakage or impairment of the IN TO ENSURE tion Data Sheets). Only the Style 15 sprinkler. ENGAGEMENT or Style 20 Recessed Escutcheon, as Do not attempt to compensate for WITH SPRINKLER applicable, is to be used for recessed insufficient adjustment in the escutch- WRENCHING AREA pendent installations. eon plate by under-or over-tightening FIGURE 3 the sprinkler. Readjust the position of W--TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP152 Page 3 of 4 Step 3. Tighten the sprinkler into the - sprinkler fitting using only the W-Type 2-7/8" DIA. 6 Sprinkler Wrench (Figure 2). With (73,0 mm) reference to Figure 1,apply the W-Type 6 Sprinkler Wrench to the wrench flats. 2-1/4" DIA. - Torque sprinklers 7 to 14 ft.-lbs.(9,5 to FACE OF (57,2 mm) 19,0 Nm). SPRINKLER FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers + 1 The Series TY-B Recessed Pendent / _ FLUSH . Sprinklers must be installed in accor- (93/±7,9 mm) / 1 �'V dance with the following instructions. } / II Step A.After installing the Style 15 or —' 1/8" i Style 20 Mounting Plate,as applicable, MOUNTING over the sprinkler threads and with SURFACE (3,2 mm) pipe-thread sealant applied to the pipe CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) threads,hand-tighten the sprinkler into the sprinkler fitting. n'B PLATE 3/4"(19,1 mm) Step B.Tighten the sprinkler into the FIGURE 4 sprinkler fitting using only the W-Type SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) 7 Recessed Sprinkler Wrench (Figure WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After the ceiling is installed or SPRINKLER 2-1/4" DIA. the finish coat is applied, slide on the FITTING (57,2 mm) Style 15 or Style 20 Closure over the 5/16±1/4" Series TY-B Sprinkler and push the (7 g±6,4 mm) 1/2"(12,7 mm) Closure over the Mounting Plate until its flange contacts the ceiling. FLUSH 1 1 + Care and t 1 - _al MOUNTIN/ ' : '� 1/8" J Maintenance SURFAC (3,2 mm) The TYCO Series TY-B, 5.6 K-factor, — - Upright(TY315)and Pendent(TY325) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-B PLATE viced in accordance with this section. 7/8"(22,2 mm) FIGURE 5 Before closing a fire protection system SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) main control valve for maintenance WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. The owner is responsible for the system from the proper authorities Sprinklers that have been exposed to inspection,testing,and maintenance of and notify all personnel who may be corrosive products of combustion, but their fire protection system and devices affected by this action. have not operated,should be replaced in compliance with this document, as Absence of the outer piece of an if they cannot be completely cleaned by well as with the applicable standards escutcheon, which is used to cover wiping the sprinkler with a cloth or by of the National Fire Protection Associa- a clearance hole, can delay sprinkler brushing it with a soft bristle brush. tion (e.g., NFPA 25), in addition to the operation in a fire situation. Care must be exercised to avoid dam- standards of any other authorities hav- ing owner must assure that the age to the sprinklers - before, during, ing jurisdiction. Contact the installing sprinklers are not used for hanging and after installation. Sprinklers dam- contractor or sprinkler manufacturer any objects and that the sprinklers are aged by dropping, striking, wrench regarding any questions. twist/slippage, or the like, must be Automatic sprinklers are recommended only cleaned by means of gently dust- ing with a feather duster; otherwise, replaced. Also, replace any sprinkler to be inspected,tested,and maintained non-operation in the event of a fire or that has a cracked bulb or that has lost by a qualified Inspection Service in inadvertent operation may result. liquid from its bulb. (Ref. Installation accordance with local requirements Sprinklers which are found to be leak- Section.) and/or national codes. ing or exhibiting visible signs of corro- Thereafter, annual inspections per sion must be replaced. NFPA 25 are required;however,instead of inspecting from the floor level, a Automatic sprinklers must never be random sampling of close-up visual painted, plated, coated, or otherwise inspections should be made. altered after leaving the factory. TFP152 Page 4 of 4 P/N* 77 - XXX - X - XXX 1 1 SIN SPRINKLER TEMPERATURE FINISH RATINGS 570 5.6K UPRIGHT(1/2"NPT) TY315 1 NATURAL BRASS 135 135°F(57°C) 571 5.6K PENDENT(1/2"NPT) TY325 3 PURE WHITE(RAL9010)** 155 155°F 68°C POLYESTER ( ) *Use suffix"I"for ISO 7-1 connection; SIGNAL WHITE(RAL9003) for example,77-570-4-175-I 4 175 175°F(79°C) POLYESTER 9 CHROME PLATED 200 200°F(93°C) ""Eastern Hemisphere sales only P86 286°F(141°C) 360 360°F(182°C) 000 OPEN*** ***OPEN indicates sprinkler assembly without Glass Bulb, Button,and Sealing Assembly TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION : -- '' _. Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6, Standard Response, (specify) temperature rating,(specify)finish, P/N (specify,refer to Table A) Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish, P/N(specify') Specify:Style 20 Recessed Escutcheon with(specify')finish, P/N(specify') *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. Vico TEFLON is trademark of The DuPont Corporation. Fire Protection Products Eddythread 40 • A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS NOMINAL PIPE SIZE ® sift) sI (is) BUNDLE. IIZE. 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL SIZE(in) SCHEDULE 40 EDDYTHREAD 40 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems 1819 Clarkson Road For additional information, Chesterfield,MO 63017 contact your salesperson today at C()Us IIBuL,MOOSE TueE connawnw (800)325-4467 (800)325-4467 or(636)537-2600 LISTED FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 11/: A CCR . O company e-mail:sales(a,bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 ' �� Ductile Iron Fittings- Class 300 UL/FM c ® us APPROVED Fig. 35E 3-90°Elbow LISTED Size Part Number ' Parkin Weight in in inner- aster lb -ilk., 1/2 35E 3004 1.13 100 200 0.2 isgellII ,3/4# 35E -'; . -1 1 '7t 14P 0:3 A 1 35E 3010 11.2570, 40 5080 0.5 I Igi4 Is ",, .,. ...'` 1-1/2 � 35E 3014 1.94 18 36 1.1 -2 ' ' = ' .,35E 3020 y .. ',2,2,5'- . , 4-0 20 - 1 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow iv:* Size part Number A B Packing Weight in in in Inner Master Ib 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 IS 1 x 1/2 3&'63010Q04 1.26 1,36 70 140 `0.4 1 x 3/4 35RE3010006 1.38 1 45 50 100 0 4 A 1-1/4x 1/2 :,., 35RE 12004 L84 . L53 ` 3 7Q 1.5 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 0.6 1,,,1/4,.x.,,I . 35R5 12010 1,53 1.67 3 s 0. -,---- 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1x3/4 .`s.25RE14 1,52 1,,75 : ' 25 '56 ".0.,7` 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 14/43 86301401 1:62'.-:' --.,,--,-,_.f,,,,,,I,68 18 36-:-1,2,...,-,;-.-1.0 .` 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 314 . , 35RE602f 1.601 ,- 1.97 . °:1 . 1.0,..,,,,'-- `r 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 11/4 351RE3020012 1.94 2.19 12 '24 ,-.-1-.0-4' - 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2:{1-1/2 35 E 024,014 2,16 2.51 61 '` 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Yi Size Pert Number A Packing Weight in in' Inner Master -• ib' �� 1/2 35F 3004 0.88 150 300 0.2 ./� ,314 ' 3-'I✓,3 0:98 39 . „" :1 1 c0.3 - 1 35F 3010 1.13 40 80 0.5 11)4 �E X122 429 2 } (37: ��i IA 1 1!2 35F 3 4 .0 2 35F 3424014 11..6944 1020 0I0 11.. 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee SizeinP `i ' ett Number bn' Inner' PackingMaster Weight . illiCpl A 1!2 35T 3004 1 13 80 160 0.3 , ., ,-' -- i 314 354.3#06 .-.1 31' 1 35T 3010 1.50 25 50 0.7 41J4 X30`12 '., 123 401 9 i (-A-41+-A-) 1-1/2 35T 3014 1.94 10 20 1.5 alb 2< 351 .1.c015,:-.-.:,-.1--_,.:,:!.?.-- =f :2. i`# 2-1/2 35T 3024 2.70 4 8 4.3 • 111 SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • wwwsmithcooper.com Ductile Iron Fittings- Class 300 UL/FM • c (DI usAli>,,,,,,,,,,.. LISTED Fig. 35CP3 -Straight Coupling with Ribs A n Size pert Number A - '- - Packing Weight - 111/12 35CP3004 11318 Inner2Mas olb • .1 • - 2/4- -=-"'-.-' 350P3006"--.'-"f;"- ' ,'"_1;..6,3-i----_-':f.-_ -..".--;-,:,:tpp :---, _-_,- ."---._. -,-200:*--_--"'-, - --,4? -_ I -,,, .,..,-,- ....-4,................. 11111 1 35CP3010 1.75 60 120 0.4 2 lair j A ,, ,.-:--..,1.,,,,11121-11xx--.213-11:11,,,.//22442"i',.:-.,:'-,',-,-,:'" "'3.5;-33-55H.:53s3R13.55GP,5cc.aCcC33apPe:00.1,P334:40.0°0022101140420tr4.-_.,',,-,',.,,'"..,,---,,-"11122,3,25.,6.6..P09°.-19.909i::,',..z,;.,--:,::'".,,s-'"-.,'-7.,„,,,',',.,78,8521.090:5 :','„,-,,.-,--,.:,-_:',,-'.,..,,,',:-_.4..1'1-60:3:1 06280000, E.',.,,..,'',','",,.,"-"..,--.00-020014:.:4..322":.--,:,,'.,-,,,',1,--,,,, Fig. 35RC3 -Hex Reducing Coupling 006 , 7_7 ... Sizein , Part Number A - Packing Weight 1 in Inner Master - lb 11.1111, _ 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 - 2 -1(riot hex)- -35Rc3020040----" - - :2,01 -'-- -, -20 - 4Q ,--„---. -':--..=,.:,-... 1.0 Fig. 35HB3 -Hex Bushing Ili ( B Size - - A _ Packing Weight Part Number - . ,, in in " inner Master lb 1 x 1/2 35HB3010004 1.06 180 360 0.2 lir IA -- -'.1.k.-.8.14 ' 35H83010005 1.O& -'-.:---: ,''' 1100:',' '-'..-'-''''.-',"'9e0-::" i,' ---:-,- .,..-6,4' 11 , ' , — 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 21.--."';---",,r_-.7----1A17113QQ20.01-0'...f.. - : "1.40'-`,-':- "-r..f!::::','-'40-=i'-";"-"-i '-- ::".=:80' - -"'"-,.,'' ' '0-,6 ,-;-...-1.- , ----.4- 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 ,- ,,2,x.1,-J/2,,",' ----39.1K1029014- '.-'','f..,$4-- .-t,,-..,-,--_ . , ....A.p..,,_ ..,-,-. ' '_ 80 _--,-- "",..-_,-.--,13.6',--F ..... ..,..,.... . k•:::.,-oi..ritii . ...,,,, Fig. 35SP3 -Square Head Plug .,---,i--- ' , ' A - Packing Weight Size Packi Partum Nber ----.45: In . - in ., Inner Master - lb 2 i IA 31/14/,_.,,, , ..,335SP30064 : . 10:9124 .,.,.„. , , 350600 : . ,1720031. ,..06.017, 1 35SP3010 1.25 200 400 0.1 I7114"i''-."-"-?";;-r.,e'-'"84SPV;12-f"-",,- --,-,-,:-4-'4,91,-:-.-''"'•5':',..k-100-1:.,',--,-::---,-"---'--.000.; -,:-.,---..-_..-,----. "--.--:0.3 1-1/2 35SP3014 1.44 80 160 0.4 ',2---,---',-;....12. '-...35SP30.2Q-"..,-'.'-' -S .-"4.50...:-..2-',7.,;-:..„-,.-.,.•,--...:4§,---,-.s..r. ;„ ..--,,90:--.-4,-_„:.,.. Fig. 35U 3-Union with Brass Seat . _ A , ,size 0....1iiimh.,.. A - - ,.., Packing -.. Weight - in . t u"" ..-"'""-°' -,, in- . , Inner -, Master lb 1 35U 3010 2.19 20 40 1.0 IIII ' 4ti'1Z+;,,',-;:i .1:17---:':"4:6i.l740I2 --,"'"--' ;--- 'Z502.-'-f-;1-----'...-",--, '---1,-.§-,:'',-,:-;: : :1-10.;""-I-j, -'' '.--';'1'g: , __ I 1-1/2 35U 3014 _ 2.62 10 20 4 .,1.7 ., ,- 861Nktirhitatoilemai g4,,,-,.-',..:1-'4'';::....-.;;.i,..a.:62u 0,0,201.,,;",...;:i!,;-,,,---,'„4,=(.2:-;;;"' -,"?..,,":5--'!6----,--:,f--';':.,.,"7.,-,,,,,_-:"10„:"'--.,e,,,:"."..-.'„,f---.,-_,.--.1M„:, , 113 SNII1'1-1-COOPER INTERNNI1()NA1,® • "I'OLI,FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com I* c �L u8 VdS LISTED 491a/27 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating'h,3/4,and 1715,20 and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 1'/4 through 76.1 mm/32 to 76.1 mm piping systems,Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Ail ill Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up r to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Gasket: • Grade"E"EPDM-Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America, Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �Ctal/lI�.'• REV G 1.0,52 1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock'') STYLE 922 DIMENSIONS -....-_-.. Nominal Size Hole inches/mm Diameter Dimensions inches/millimeters Approx. Weight Each Y rtCane#t rfl=tt8d+15 Z Ott V V 4" 2 I 11/2 X Ya1.83 1.10 3.87 .... . 045 .11 L- 13/16 1.30lbstag ���� T 32 15 30.2 33.0 46.5 27.9 98.3 1.0 65 0.. /a 13/16 1.28 1.83 1.10 3.87 2.56 1.7 TAW 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 ■ ■ W �L]-� 1 13/16 1.52 2.18 1.10 3.87 2.56 1.2 llf 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 l Yz X '1 1 3/16 1.42 1.95 1.22 4.08 40 15 2.56 .5 30.2 36.1 49.5 31.0 103.6 65.0 0.54 '/ 13/16 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 50 X 15 13/16 1.66 2.19 1.46 4.60 2.56 1.3 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.641 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 % 13/16 1.91 65 X 15 2.44 1.71 5.40 2.56 1.6 30.2 48.5 62.0 43.4 137.2 65.0 0.73 N 13/16 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1 3/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X 1/2 1 3/76 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2. 48.5 62.0 43.4 139.7 65.0 0.73 3 13/16 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 13/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �CitaulIC° 2(7.52 REV_G IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL Inches/nun Feet/meters Run Sae x Outlet Size 213,Section 161(C=120(,FT 1%< X 1 8.5 32 25 2.6 11 X • _... 40 25 2.6 2 X 1 8.5 50 25 2.6 21/2X 1 8.5 65 _._. 25 2.6 76.1 mm X Z15 8.5 2.6 *Hazen-Williams coefficient of friction's 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaul,c REVD , . 10,523 art L STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are Installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaullri 10.52 Pipe Hangers Fig.200- "Trimline"Adjustable Band Hanger (B-Line Fig.B317ONF) t►7"Oi.CC} Fig.200F- "Trimline"Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) Fig.200C- "Trimline"Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) C@LIS Fig.200S - "Trimline"Adjustable Band Hanger with Non-Captured Nut LISTED Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled io swivel nut design permits hanger adjustment after installation. Features: • (1/2" (15mm)thru 2" (50mm1) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design -.\ keeps adjusting nut from separating with hanger. Hanger is easily ;, B installed around pipe. For hanger with non-captured nut order Fig. 200S. n % • (21/2" (65mm)thru 8" (200mm)) Spring tension on nut holds it securely in ,, 1:: / hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) _ in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Fig.200-1/2.200-3/4 Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (200mm)). Fig.200-1to200-2 Fig.200-21/2 to 2008 Conforms to Federal Specifications WW-H-171 E &A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F(343°C) 4.` ^T Finish: Pre-Galvanized. Stainless Steel ' ri materials will be supplied with (2) hex nuts in place of a knurl nut. g' Order By: Figure number and pipe size s Designed to meet or exceed requirements of FM DS 2-0. ' Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) "`. in. (mm) in. (mm) lbs. (kg) ': 200-1/2 1/2' (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1° (25) 3/9".46 33/8" (85.7) 23/4" (66.7) 12 (5.5) ,,.?200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200-1'/2 11/2" (40) 3/8"-16 31/8" (98.41 27/8" (73.0) �` 14 (6.4) : 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2"; (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/8"-16 51/8" (149.1) 4" (101.6) 29 (13.3) _ 200-31/2 31/2". (90) 3/8"-16 73/8" (187.3)' 51/4" (133.3) 34 115.6► Fig. 200-4 4" (100) 3/8'-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8 (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4)` 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. . ... a a Id-Line Fire Protection Solutions 21 Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (Tolco Fig.103) B3205L - Threaded Rod (right& left hand threads) TL ) Size Range: 3/8"-16 thru 3"-4 rod Specify Length 1111 1�1�1 Material: Steel 'L Function: Recommended for use as a hanger support in hanger assemblies. TL �� Rod is threaded on both ends with right hand threads of the length shown.Also ��ll�ll�• l available with left and right hand threads-specify Fig. B3205L when ordering. �11�1i a Maximum Temperature: 750°F(399°C)• thread size Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) 83205-3/8 X'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21/2 (63.5) 1350 � + , (6.00) 1057 (4.70) 03205./0 x L 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-8/4 x'1' 3/4"-10 3 (76.2) 3230 (14.37) 2530 (11.25) 63205.7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) 83205-1 x'�.r 1°-8 4° (101.6) 5900 (26.24) 4620 (20.55) 63205-11/0 x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) 133205.11/4 x'L' 11/4"-7 5 (127.0) 9500 (42.25) 7440 (33.09) 63205-11/2 X'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) 83205.13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) 83205-2 x'L' 2'-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 63205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) 03205-21/2 X'L' 21/2"-4 10 (254.0) 39800 (177.03) 31169 (138.64) . 8 3205-2314 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08)B3205-3 X'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths croico Fig.100) Fig. 99 -All Threaded Rod Cut To Length »��11111� Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length 11yl��y1 .a 11%)11111��1111111 Material: Steel ���� � Maximum Temperature: 750°F(399°C) 40 H d'i. c 0 Finish: Plain.Contact B-Line for alternative finishes and materials. andOrder By: Part number, rod diameter and finish Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig 99 Per Inch Lbs. (kN) Lbs. (kg) 01111/4"x 120 20 240 (1.07) 12 (5.44) ATR 3/0"x 120 99-/0"x I�j> 16 730 (3.24) 29 (13.15) ATR 1/2"x.120 ..1/2"X,length 13 1350 (6.00) 53 (24.04) ATR I8"ix 120 995/s"x 11 2160 (9.64) 89 (40.37) AIR 3/4"x 12i1 = /4"x length 10 3230 (14.37) 123 (55.79) ATR7/34, 120 99-z/8"1t length 9 4480 (19.93) 170' (77.11) ATE).1"x 120. 1"x length ' 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B- Pipe Hangers&Supports ine 236 Revised 4/28/2014 by E.'[+N VERTICAL MOUNT SAMMYS MYS° for ��- � SAM R Concrete . . i`-:r.3 1,,EA:',,:::--._._, � , I..,t�,,� . , .,- ?*„.4#2.,,,1-',.p.,:*,--: •Easy two step process(Drill hole& -,r,,...G, s'* drive Sammy concrete anchor). :44' 1 , _ •%" •pre-drilled pilot hole required. ", •Concrete Installation Tool available for =. 4 a one tool installation process. a Metal Deck # Black 4 ? 1/4" 8058957 CST 200 5M6x13/4" 2400 25 125 Driver 3/8' 8059957 CST 20 5/16 x 1-3/4' 2400 1475 25 125j}_Nut Part# 0, ,. . 3/8" 8145925, CST 20-SS 5/16 x 1374" 2400 25 125 8113910 ▪ ,e,,,,::-.- 1/2" 8060925 CST 2 5/16 x 1-3/4" 2400 25 125 a r=: "Tested in 3000 PSI concrete The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes $4a/ Red r_ .�>,- into contact with the material you are installing into,continue drilling until nut driver spins tree,Installation is then complete.Warranty requires the use of the appropriate nut driver for Nut Driver > installations. past„ 8114910 Concrete / Wood Installation Kit �.:L i .--,� , S -S,r.I . r, � �rvvu� r�{s - ��� .ris tz,,..,f1;';;;:;!',4,j';'...„,.4,.t.I'Ff:-.41:ft''..t.:.,:t.,77,,,,1 f',,,"'r7:.:Ei'.V4:,:zzie'„'„';-:F:S,:;'i.',„':Atr'':'.,-.i:'1:::::!!J',.::=',1:,..t,:gi:::',.,i4.,,t'.":*,„,.'"-,"l''s.,..t,'-'''',-T,::;?::o-4V,4,''':„::64:::4:-,a''-,4 8122910 Concreteinstallation �Ks{a ) Kit includes the following items: 8113910 #14 Black Nut Driver(b) 1 ONE tool to . � 8114910 #14 BW Red Nut Driver(c) 1 A ' • 8116910 #250 Bit(1/4")(d) 1 8117910DRILL SDS Bit(1/4")(e) 1 the hole and 8118910 7/32 Wood Bit(I) 1 8120910 HEX,250 Bit Receiver(1/4")(g) 1 DRIVE the anchor! eil„-„i ,-..,,,,,::25,,!!!,4 , ... „„„ „,„,-, 8098910 SI 250 Sleeve(b) 1 , „. ,. , l (a) 8121910, SOS B250 Bit Receiver(1/4")* 1 .▪ ' � *Onlysoldseparately-notincludedinkit Rotary Hammer Drill into concrete Hammer Drill into concrete ▪ -''''''� (b) Aalillillow ▪ '',*-'&-t-- -1, _ ° '� (o) For the most up to date information,visit www sammysuperscrew.com 10 r 1F'{�