Specifications /145 Tom/F - oa6s- 1 5,—t re, &/-J41(S S oi.„4 MAR 2 9 fl 8 ` ` ` a, "E SWIMMING POOL 15150 SW Missouri Place Tigard, OR 97224 STRUCTURAL CALCULATIONS VLMK Project Number:20180004.08 Often Landscape Architects, Inc. 3933 SW Kelly Avenue, Suite B Portland, Oregon 97239 s,c R u c r tJ Rq \�RED PROFFS ` 14: i ; , - v'0-. GON 2 ' • • 23, 2 �/ KPP\'2 I EXPIRES: 6-30-20 ICI I r Prepared By: Natalie Lyons,BT VLMK February 26,2018 ENGINEERING + DESIGN Structural Calculations:Maginnis Residence Swimming Pool DC-1 Project: Maginnis Residence Swimming Pool Project Number: 20180004.08 Project Address: 15150 SW Missouri Place Document: Structural Calculations for Tigard, OR 97224 Building Permit TABLE OF CONTENTS Design Outline and Criteria DC - 1 thru DC 2 Structural Calculations C - 1 thru C - 6 Swimming Pool Site Plan SK- 1 DESCRIPTION OF STRUCTURAL SYSTEM This project consists of a reinforced concrete below-grade swimming pool. This package includes structural calculations providing the required reinforcing steel for the radius walls of the pool for varying radii. These structural c• •. . - .-• • •_ -. • compliment drawings provided by others. This design is done with 2,500 psi concrete to avoid the need for concrete special inspection, though oncrete to be used is specified at 3,000 psi. This design is done based on 60 ksi reinforcin• Due to the specified hydrostatic relief valve, no provisions or •uoyancy ave been incorporated. This design is based on a flat site, assumed geotechnical design criteria, code prescribed minimum properties, and without the use of a geotechnical investigation. The client and owner have declined to obtain a geotechnical investigation and by doing so, have accepted all liability for soil related design issues. It is the responsibility of the pool contractor to notify VLMK Engineering + Design if the pool is not being constructed on a flat site. ***LIMITATIONS*** VLMK Engineering + Design was retained in a limited capacity for this project. The design is based upon information provided by the client, who is solely responsible for the accuracy of the information. No responsibility and/or liability is assumed by, nor is any to be assigned to, VLMK Engineering + Design for items beyond that shown in this Structural Calculation Package. G`~ttCAD2O18'20180004\08 Maginnis Residence Swimming Pool 2-22.18\O2 Calculations\Oregon Residence Swimming Pool DC_Maginnis Residence.docx 3933 SW Kelly Avenue Portland,OR 97239 tel:503.222.4453 fax:503.248,9263 www.vlmk.com Structural Calculations:Maginnis Residence Swimming Pool DC-2 CODES 2014 Oregon Structural Specialty Code (Based on the 2012 International Building Code) MATERIALS Concrete Swimming Pool Walls f = 2,500 psi Reinforcing Steel ASTM A615 Gr. 60 Fy = 60 ksi SOILS Lateral Earth Pressure (EFP) Cantilevered Wall 30 pcf GN4CAD2018\20180004\08 Maginnis Residence Swimming Pool 2-22-18\02 Calculations\Oregon Residence Swimming Pool DC_Maginnis Residence.dco 3933 SW Kelly Avenue Portland,OR 97239 tel:503.222.4453 fax:503.248.9263 www.vImk.com VL M K Project: Maginnis ResidenceJob#: 20180004.08 BY NAL Date: 2/26/2018 Sheet#: C-1 ENGINEERING.DESIGN v3.01-Software Copyright 2015 VLMK Consultin. En.sneers. All RI.hts Reserved. Pool Wall Reinforcing Calculations - General 1' Radius Based on 2012 International Building Code and ASCE7-10 S r t____H(top) DESIGN INPUT AND GEOMETRY R = 1 ft Input 1'-0" < R < 6'-0" h1= 9 in h2= 6 in .. h3= 24 in ttop= 12 in P `-,-:. to= 6 in Wall/Floor Thickness T = 6 in Min Thickness p = 30 pcf Soil Pressure — Wconc= 150 pcf Weight of Concrete �., Fy= 60 ksi Steel Strength t(o) R 0 = 0.9 Load Factor i r' Cc= 3 in Reinforcing Clear Cover , f,� F',= 2500 psi Concrete Strength 'S k . ,�"/ DESIGN OUTPUT 1V1 ,6 e h4= 4.5 ftIP 4NillipPmax= 136 psf Max Pool Depth _I ` t1= 6.0 in ) t2= 6.0 in p(max) T = 6.0 in MOT,A=(1/2*h4*Pmax)(1/3*h4)*1.6= 0.74 kip-ft Point Load Distance to 'A' Resisting Moments P1= 0.113 kip d1= 0.72 ft PI*d1= 0.08 k-ft P2= 0.019 kip d2= 0.88 ft P2*d2= 0.02 k-ft P3= 0.188 kip d3= 0.47 ft P3*d3= 0.09 k-ft P4= 0.036 kip d4= 0.43 ft P4*d4= 0.02 k-ft Ps= 0.036 kip ds= 0.25 ft Ps*d5= 0.01 k-ft P6= 0.024 kip d6= 0.00 ft P6*d6= 0.00 k-ft 0.9*MREs,A= 0.19 k-ft MNET,A= 0.56 k-ft REINFORCING DESIGN SUMMARY d = T-Cc= 2.81 in (distance to reinforcing) AS,REQ'D = 0.04 int/ft Quantity Size Spacing Fy= 60 ksi 'A' Bars 1 # 3 at 12 in o.c. AS= 0.11 in2 'B' Bars 0 # 3 at 12 in o.c. AS= 0 in2 As,TOTAL= 0.11 in2 As,TOTAL > As,REQ'D REINFORCING IS ADEQUATE 3933 SW Kely Avenue Portland,OR 97239 tel: 503.222 4453 fax.503.248.9263 www,v'r k,car VVLIVIK Project: Maginnis Residencelob#: 20180004.08 By NAL Dote: 2/26/2018 .Sheet#: C-2 ENGINEERING•DESIGN v3.01-Software Copyright 2015 VLMK Consulting Engineers. All Rights Reserved. Poo/ Wall Reinforcing Calculations - General 2' Radius Based on 2012 International Building Code and ASCE7-10 DESIGN INPUT AND GEOMETRY t(tap) R = 2 ft Input 1'-0" < R < 6'-0" h1= 9 in h2= 6 in01 4 - h ' I = 3- 24 in ti ttop= 12 in P2 �� rR to= 6 in Wall/Floor Thickness T = 6 in Min Thickness p = 30 pcf Soil Pressure ti- s _ Mom= 150 pcf Weight of Concrete —, Fy= 60 ksi Steel Strength (�) R 0 = 0.9 Load Factor 1, NI f4' ti�� ,: Cc= 3 in Reinforcing Clear Cover F'c= 2500 psi Concrete Strength �, �,.-` r DESIGN OUTPUT '11,`x. s '61 h4= 5.3 ft 6II o Pmax= 158 psf Max Pool Depth \ I ... . .. . t1= 6.0 in 51-311 t2= 6.0 in p(mox) �(�) T = 6.0 in MoT,A=(1/2*h4*Pmax)(1/3*h4)*1.6= 1.17 kip-ft Point Load Distance to 'A' Resisting Moments P1= 0.113 kip d1= 1.02 ft P1*d1= 0.11 k-ft P2= 0.019 kip d2= 1.19 ft P2*d2= 0.02 k-ft P3= 0.188 kip d3= 0.77 ft P3*d3= 0.14 k-ft P4= 0.065 kip d4= 0.68 ft P4*d4= 0.04 k-ft Ps= 0.065 kip d5= 0.37 ft Ps*ds= 0.02 k-ft P6= 0.029 kip d6= 0.00 ft P6*d6= 0.00 k-ft 0.9*MREs,A= 0.31 k-ft MNET,A= 0.85 k-ft REINFORCING DESIGN SUMMARY d = T-C,= 2.81 in (distance to reinforcing) AS,REQ'D = 0.06 in2/ft Q Y Quantity Size Spacing F„= 60 ksi ° 'A' Bars 1 # 3 at 12 in o.c. A5= 0.11 in2 'B' Bars 0 # 3 at 12 in o.c. A5= 0 in2 As,TOTAL= 0.11 in2 As,TOTAL > AS,REQD REINFORCING IS ADEQUATE 3933 SW Kedy Avenue Part!and,OR 97239 tel:503.222.4453 fax:503.240.9263 wwuVw vltnk.COM . 1 VV L M K Project: Maginnis ResidenceJob#: 20180004.08 BY' NAL Date: 2/26/2018 Sheet#: C-3 ENGINEERING«DESIGN v3.01-Software Copyright 2015 VLMK Consultin. En.sneers. All Rights Reserved. [ Pool Wall Reinforcing Calculations - General 3' Radius Based on 2012 International Building Code and ASCE7-10 d l DESIGN INPUT AND GEOMETRY *op) R = 3 ft Input 1,-0" < R < 6'-0" ' h1= 9 in h2= 6 in h3. 24 in -z------ trop= 12 in P`: to= 6 in Wall/Floor Thickness T = 6 in Min Thickness p = 30 pcf Soil Pressure Wconc= 150 pcf Weight of Concrete Fy= 60 ksi Steel Strength (") R 0 = 0.9 Load Factor / Ce= 3 in Reinforcing Clear Cover 1P4 �,1 F'a= 2500' psi Concrete Strength ., kk 'tet,./ DESIGN OUTPUT IJ '`'3 Q h4= 6.0 ft 6 4 Pmax= 180 psf Max Pool Depth h t1= 6.0 in 61-3" d(;) p(mox) t2= 6.0 in T = 6.0 in ¢ f MOT,A=(1/2*h4*Pmax)(1/3*h4)*1.6= 1.72 kip-ft Point Load Distance to 'A' Resisting Moments P1= 0.113 kip d1= 1.31 ft P1*d1= 0.15 k-ft P2= 0.019 kip d2= 1.48 ft P2*d2= 0.03 k-ft P3= 0.188 kip d3= 1.06 ft P3*d3= 0.20 k-ft P4= 0.094 kip d4= 0.93 ft P4*d4= 0.09 k-ft P5= 0.094 kip d5= 0.48 ft P5*d5= 0.04 k-ft P6= 0.031 kip d6= 0.00 ft P6*d6= 0.00 k-ft 0.9*MREs,A= 0.46 k-ft MNET,A= 1.26 k-ft REINFORCING DESIGN SUMMARY d = T-Ce= 2.81 in (distance to reinforcing) As,REQ'D = 0.10 in2/ft Quantity Size Spacing Fv= 60 ksi 'A' Bars 1 # 3 at 12 in o.c. As= 0.11 in2 'B' Bars 0 # 3 at 12 in o.c. As= 0 in2 As,TOTAL= 0.11 in2 As,TOTAL > As,REQ'D REINFORCING IS ADEQUATE 3933 SW Kelly Avenue Portland,OR 97239 tel. 503.222.4453 fox:503,243.9263 w w.vr1mk.corn . 1 VVLIVIK Project: Maginnis Residencelob# 20180004.08 BY NAL Date: 2/26/2018 Sheetp: C-4 ENGINEERING ,DESIGN v3.01-Software Copyright 2015 VLMK Consulting EnglatemNl Rights Reserved. r---- - ........_ Pool Wall Reinforcing Calculations - General 4' Radius Based on 2012 International Building Code and ASCE7-10 DESIGN INPUT AND GEOMETRY t(top) ral R = 4 ft Input l'-0" < R < 6'-0" h2= 6 in 0001 f h3= 24 in ttop= 12 in P t,= 6 in Wall/Floor Thickness T = 7 in Min Thickness • , p = 30 pcf Soil Pressure .c Wconc= 150 pcf Weight of Concrete — t(o) R i Fy= 60 ksi Steel Strength 0 = 0.9 Load Factor /// s4 Cc= 3 in Reinforcing Clear Cover kk.".\-) F'c= 2500 psi Concrete Strength ../r„, 1114‘,1/466.,,_(CA1 DESIGN OUTPUT 8 IOW — h4= 6.8 ft Mile, 0 —, Pmax= 204 psf Max Pool Depth s, I A ti= 6.4 in 7..3.1 p(max) d(i) t2= 6.9 in T = 7.0 in MOT,A=(1/2M4*Pmax)(1/3*1.14)*1.6= 2.51 kip-ft Point Load Distance to 'A' Resisting Moments P1= 0.113 kip d1= 1.60 ft Pi.*di= 0.18 k-ft P2= 0.019 kip d2= 1.76 ft Pz*dz= 0.03 k-ft P3= 0.188 kip d3= 1.35 ft P3*d3= 0.25 k-ft P4= 0.127 kip d4= 1.18 ft Pa*da= 0.15 k-ft P5= 0.137 kip d5= 0.60 ft 1:36*ds= 0.08 k-ft P6= 0.043 kip d6= 0.00 ft P6*d6= 0.00 k-ft 0.9*MREs,A= 0.63 k-ft MNET,A= 1.89 k-ft REINFORCING DESIGN SUMMARY d = T-Cc= 3.81 in (distance to reinforcing) As,REQ'D = 0.11 in2/ft Quantity Size Spacing Fv= 60 ksi 'A' Bars 1 # 3 at 12 in o.c. As= 0.11 in2 'B' Bars 1 # 3 at 12 in o.c. A5= 0.1104 in2 As,TOTAL= 0.221 in2 As,TOTAL > As,REQ'D REINFORCING IS ADEQUATE 3933 SW Kelly Avenue Portland,OR 97239 tel:503 222 4453 fax: 503 248 9263 www.vinik fon • I I Nir V L M K Project: Maginnis ResidenceJob# 20180004.08 BY NAL Date: 2/26/2018 Sheet#: C-5 ENGINEERING*DESIGN v3.01:Software Copyright 2015 VLMK Consulting Engineers. All Rights Reserved. ....... Pool Wall Reinforcing Calculations - General 5' Radius Based on 2012 International Building Code and ASCE7-10 DESIGN INPUT AND GEOMETRY t(top) R = 5 ft Input V-0" < R < 6'-0" ri hi= 9 in h2= 6 in higi -1E.- h 3= 24 in 04 ttop= 12 in P ii to= 6 in Wall/Floor Thickness T = 8 in Min Thickness —.7 p = 30 pcf Soil Pressure Wconc= 150 pcf Weight of Concrete .1*. t(o) R i Fv= 60 ksi Steel Strength , ..c 0 = 0.9 Load Factor kihe p•-.) / . , • .., Cc= 3 in Reinforcing Clear Cover •ty,) /7 F'c= 2500 psi Concrete Strength ‘-),.). /// UM DESIGN OUTPUT OUTPUT El h4= 7.6 ft Pmax= 229 psf Max Pool Depth ..• '"''A"-----,__:: p(max) d( ) t2= 7.8 in T = 8.0 in MOT,A=(1/2*h4*Pmax)(1/3M4)*1.6= 3.53 kip-ft Point Load Distance to 'A' Resisting Moments Pi= 0.113 kip d1= 1.88 ft Pedi= 0.21 k-ft P2 = 0.019 kip d2= 2.04 ft ped _ 0.04 k-ft P3= 0.188 kip d3= 1.63 ft P3*d3= 0.31 k-ft P4= 0.163 kip d4= 1.43 ft Reda= 0.23 k-ft P5= 0.186 kip d6= 0.72 ft P3*d5= 0.13 k-ft P6= 0.057 kip d6= 0.00 ft Ped6= 0.00 k-ft 0.9*MREs,A= 0.83 k-ft MNET,A= 2.70 k-ft REINFORCING DESIGN SUMMARY d = T-Cc= 4.81 in (distance to reinforcing) As,REQD = 0.12 in2/ft Quantity Size Spacing F = 60 ksi 'A' Bars 1 # 3 at 12 in o.c. A,= 0.11 in2 'B' Bars 1 # 3 at 12 in o.c. As= 0.1104 in2 As,TOTAL= 0.221 in2 A5 TOTAL > As,REQ'D REINFORCING IS ADEQUATE _......._ 3933 SW Kelly Avenue Portland,OR 97239 tel 503.222 4453 Fox: 503 248.9263 www.vlmk.com IvV LING M K Project: Maginnis Residencejob#: 20180004.08 BY NAL Date: 2/26/2018 Sheet#: C-6 ENGINEERDESIGN v3.01-Software Copyright 2015 VLMK Consulting Engineers. All Rights Reserved. — — Pool Wall Reinforcing Calculations - General 6' Radius Based on 2012 International Building Code and ASCE7-10 DESIGN INPUT AND GEOMETRY t(top) R = 6 ft Input 1'-0" < R < 6'-0" ri h1= 9 in h2= 6 in -c h3= 24 in ____ tt 0 p= 12 in P''\ '---- -...c....4„. to= 6 in Wall/Floor Thickness T = 9 in Min Thickness * in p = 30 pcf Soil Pressure WConc= 150 pcf Weight of Concrete , ...t t(0) / Fy= 60 ksi Steel Strength R — 0 = 0.9 Load Factor 4 '4 Cc= 3 in Reinforcing Clear Cover , L23A /7 '‘ ) mr. -.) F'c= 2500 psi Concrete Strength ..././ 'Ntf*Iiiiiii\1/4,,,\PAili16) DESIGN OUTPUT 0 11%6 I ii.3.44r h 4= 8.4 ft Pmax= 253 psf Max Pool Depth \ i -,..v 4 to r , .... A t1= 7.3 in 91-3" d(i) p(max) t2= 8.6 in T = 9.0 in MOT,A=(1/2*h4*Pmax)(1/3*h4)*1.6= 4.78 kip-ft Point Load Distance to 'A' Resisting Moments P1= 0.113 kip d1= 2.16 ft Pi*di= 0.24 k-ft P2= 0.019 kip d2= 2.33 ft 132*d2= 0.04 k-ft P3= 0.188 kip d3= 1.91 ft P3*d3= 0.36 k-ft P4= 0.201 kip d4= 1.68 ft P4*d4= 0.34 k-ft P5= 0.243 kip cis= 0.85 ft P3*d5= 0.21 k-ft P6= 0.073 kip d6= 0.00 ft P6*d6= 0.00 k-ft 0.9*MREs,A= 1.07 k-ft MNET,A= 3.72 k-ft REINFORCING DESIGN SUMMARY d = -r-cc= 5.81 in (distance to reinforcing) As,REQ'D = 0.14 in2/ft Quantity Size Spacing Fy= 60 ksi 'A' Bars 1 # 3 at 12 in o.c. A5= 0.11 in2 'B' Bars 1 # 3 at 12 in o.c. A5= 0.1104 in2 A5TOTAL= 0.221 •m 2 , A5 TOTAL > As,REQ'D REINFORCING IS ADEQUATE 3933 SW Ketly Avenue Portland,OR 97239 tel 503.222 4453 fax:503.248.9263 www.vIrnk.com • SK-1 22'-2" }4' P,OPERTY LINE 4' \ 7 I ZI I ao , O oa I M CLI t I I SHED Ln 88.-6n Iw 1 GATE: SELF CLOSING ��' // /SELF LATCHING �7 FENCE PER CODE Iw O re POOL I I 16'x32' I RESIDENCE * I AUTOCOVER _ � fn I o DRIVEWAY 1- I L. O i 0 I /n O Z O I r7 i� co CO wad i a1 EQUIPMENT / AREA I 6 I / I - I i rloh. \\\\NN.................- ... 1. Swimmingcover NIN pod has a powered meaty / 1319-91 standard complies performance F specification.and requirements to exempt o barrier. S. IMre a wall of a dwdling srw w '°.9. '-',6‘., _ cord ti s barrierbone of he or osF shall dof t mbar e mel:fie pod qui. conditions equipped with a powered safety cover ` in compliance with ASTM F1319 r other ' of proledlael ed as edf-dosing dors with self-latching deNcw.Latches Nal be located 42'-51'above ground S. Grading d camp*of all 01 e by others. SITE PLAN [�//�\� SCALE 1•_30.-0. \IQI