Loading...
Report (55) /f- cij--,cf 2.. 1.-_ ...--__, t e Dv ,pt pi c() OFFI .irCE • r Carrie 9 SG4i8a nsKglC 14 SEHeP e pR 3 to 5 N oaa tmicEk-nlae agcl etTr a_oi•ic nRr-so OoOftloinpg t u_ , T o the expert Product Data RECEIVED APR 11 2'1b-, (All? ()Icf„: PA§oto _ ® euiLDIN weatherMaer k „ ' „ -„ff.:.„--„-.3:z„,,,:7„.5;,-44,-,1,1?-:„,-,,,,„-_,,,,:-__,:„.„-_,Ett;f,--;;7. .7 2,::,,,-,,ri., ,,:„..-,z,.,,.,,,•-,,,,:-,,,,„:-,,.::::,-..,72:1 tr.S-1 ..N '-; '.; -,.---44.—'-,,,•-' ?1,41ii. ..4.74-g.4,-,-zott;;..-.,4q-s*.:1,,--t..-,...::-.., -,:-.,:trii-4.,,,!..-:;-,-..,---- 114.-..::- .r '.. .....''' ., 'l g;':,,y' 1.14',. '1Alli,K*11.;'7-*14.-P1"..17,,t4.A'Z'-.:•I'A.:'''','-'-''''AIP,',P,N,444:?'---'— ---------,.'..,4.---ii,”, , - . 'tralN''''''' ''';31,QtrA1/4.444%-r''-±:tA,...''.'141g,04,7,4`, .,-;•'4t.--7'.'Ayt.*:,;#17'.'—77777------ - - -1'4-: -- 1,itj'oz,,-,,,,"'., n„--„, r, :vi.i.„,,„i--,,,,c,,,,,sk,+,,;,%,•,%54,-,t.,,,,,,,c,-. ,„......,. , ,,,,,,-______ „. i, „, , ,::4:-..1,-'..,A,%,-•..m.NitiA14,--4,1-F-'2.-,4;',-"''''-'-. :4-11-5,._-1.'''.4.11-Y-:--- - -r '': -r :'''"'''.0'...:',,' '. ,4'.4!<;Tt4tif co8613 .... 4 1406,41r,„ Com4 V ptiron 917 TABLE OF CONTENTS PAGE PAGE FEATURES AND BENEFITS 3 APPLICATION DATA 19 MODEL NUMBER NOMENCLATURE 4 COOLING TABLES 21 FACTORY OPTIONS AND/OR ACCESSORIES 5 STATIC PRESSURE ADDERS 27 AHRI COOLING RATING TABLES 8 FAN PERFORMANCE 29 HEAT RATING TABLE 8 ELECTRICAL INFORMATION 39 SOUND PERFORMANCE TABLE 9 SEQUENCE OF OPERATION 42 PHYSICAL DATA 11 GUIDE SPECIFICATIONS 45 CURBS,WEIGHTS&DIMENSIONS 14 0 co .zr Carrier Turn to the Experts. The Carrier rooftop unit(RTU)was designed by customers for customers. With "no-strip screw" collars, handled access panels, and more we've made your unit easy to install,easy to maintain and easy to use. Easy to install: All WeatherMaker®units are field-convertible to horizontal air flow which makes it easy to adjust to unexpected job site complications. Lighter units make easy replacement. Carrier 48KC rooftops fit on existing Carrier curbs dating back to 1989.Also,our large control box gives you room to work and room to mount Carrier accessory controls. Easy to maintain: Easy access handles by Carrier provide quick and easy access to all normally serviced components. Our"no-strip"screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit's metal.Take accurate pressure readings by reading condenser pressure with panels on. Simply remove the black,composite plug,route your gauge line(s)through the hole,and connect them to the refrigeration service valve(s). Easy to use: The newly designed, central terminal board by Carrier puts all your connections and troubleshooting points in one convenient place,standard.Most low voltage connections are made to the same board and make it easy to find what you're looking for and easy to access it. Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. 2 FEATURES AND BENEFITS •Single cooling stage models are available from 3-5 ton. •SEER up to 14.1. •EER's up to 12.0. • Up to 28%lighter than similar industry units.Lighter rooftops make easier replacement jobs. • Utility connections are the same because 3-5 ton units fit on existing Carrier rooftop curbs.This saves time and money on replacement jobs. • Standardized components and layout.Standardized components and controls make service and stocking parts easier. • Scroll compressors on all units.This makes service,stocking parts,replacement,and troubleshooting easier. •Field convertible airflow.Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. • Standard Direct Drive-ECM indoor motor with optional belt drive system to meet nearly all applications. •Provisions for bottom or side condensate drain. • Capable of thru-the-base or thru-the-curb gas line routing. U •Single-point gas/electrical connection. 4 �t •Sloped,composite drain pan sheds water;and won't rust. •Standardized controls&control box layout.Standardized components&controls make stocking parts&service easier. •Tool-less filter access door. • Clean,large,easy to use control box. • Color-coded wiring. •Large,laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy. • Single,central terminal board for test and wiring connections. •Fast-access,handled,panels for easy access on normally accessed service panels. • "No-strip"screw system guides screws into the panel&captures them tightly without stripping the screw,the panel,or the unit. •Mechanical cooling(115°F to 40°F or 46°C to 4°C)standard on all models.Winter Start Kit allows cooling operation down to 25°F(-4°C)and MotorMaster to-20°F(-29°C). • High efficiency,gas heat with induced-draft flue exhaust design. • Induced draft motor ensures no flue gas can escape into the indoor air stream. • Carrier designed naturally draining heat exchanger,unlike positive pressure heat exchangers,do not need to be periodically,manually drained.This saves labor and maintenance expense. •2-in(51mm)disposable filters on all units. • Refrigerant filter-drier on each circuit. • Each circuit is protected with a high and low pressure switch. •Many factory-installed options ranging from air management economizers,2 position dampers,plus convenience outlets, disconnect switches and smoke detectors. •Standard(parts only)Warranty: 15 yr.Stainless steel, 10 yr.aluminized heat exchanger,5 yr.compressor, 1 yr.parts. •Factory-installed Humidi-MiZer®adaptive dehumidification system on all sizes with round tube/plate fin condenser coils,includes MotorMaster I controller. 3 MODEL NUMBER NOMENCLATURE Example:Position:l 4 8 I K 141 C D I A I 0 7 4 8 I A 9I10 0 1111121131 f A 15 1131 104 11A5I 1061 1A7I O8I Unit Heat Type J FactoryAssigned 48-Gas Heat Packaged Rooftop a 9 d 0 = Standard 1 = LTL Model Series-WeatherMaker® KC-Standard 14 SEER Efficiency Electrical Options A= None Heat Options C= Non-Fused Disconnect D = Low Gas Heat D= Thru-The-Base Connections E = Medium Gas Heat F = Non-Fused Disconnect and F = High Gas Heat Thru-The-Base Connections L = Low Nox—Low Gas Heat M= Low Nox—Medium Gas Heat Service Options N = Low Nox—High Gas Heat 0 = None S = Low Heat w/Stainless Steel Exchanger 1 = Unpowered Convenience Outlet Y R= Medium Heat w/Stainless Steel Exchanger 2 = Powered Convenience Outlet T = High Heat w/Stainless Steel Exchanger 3 = Hinged Access Panels (Low Nox models include—Stainless Steel HX) 4 = Hinged Access Panels and Unpowered Convenience Outlet Refrig.Systems Options 5 = Hinged Panels and A= Standard One Stage Cooling Models Powered Convenience Outlet B= Standard One Stage Cooling Models with Humidi-Miler® Intake/Exhaust Options A= None Cooling Tons B= Temperature Economizer w/Barometric Relief 04-3 ton F= Enthalpy Economizer w/Barometric Relief 05-4 ton K= 2-Position Damper 06-5 ton U= Temperature Ultra Low Leak Economizer w/ Barometric Relief W= Enthalpy Ultra Low Leak Economizer w/ Sensor Options Barometric Relief A= None B= RA Smoke Detector C= SA Smoke Detector Base Unit Controls D= RA+SA Smoke Detector 0 = Electro-mechanical Controls can be used with W7212 E= CO2 EconoMi$er IV(Non-Fault Detection and Diagnostic F= RA Smoke Detector and CO2 1 = Premiert.ink Controller G= SA Smoke Detector and CO2 2 = RTU Open Multi-Protocol Controller H= RA+SA Smoke Detector and CO2 6 = Electro-mechanical with W7220 Economizer controller Controls.Can be used with W7220 EconoMi$er X(with Fault Detection and Diagnostic) Indoor Fan Options 0 = Direct Drive ECM 2 = Medium Static Option Design Revision 3 = High Static Option – = Factory Design Revision Coil Options-Round Tube/Plate Fin Condenser Coil Voltage (Outdoor-Indoor-Hail Guard) 1 = 575/3/60 A= Al/Cu-Al/Cu 3 = 208-230/1/60 B= Precoat Al/Cu-Al/Cu 5 = 208-230/3/60 C= E-coat Al/Cu-Al/Cu 6 = 460/3/60 D= E-coat Al/Cu-E-coat Al/Cu E= Cu/Cu-Al/Cu Note:On single phase(-3 voltage code)models,the F = Cu/Cu-Cu/Cu following are not available as a factory installed option: M= Al/Cu-Al/Cu—Louvered Hail Guard - Humidi-MiZer N= Precoat Al/Cu-AI/Cu—Louvered Hail Guard - Coated Coils or Cu Fin Coils P= E-coat Al/Cu-Al/Cu—Louvered Hail Guard - Louvered Hail Guards Q= E-coat Al/Cu-E-coat Al/Cu—Louvered Hail Guard - Economizer or 2 Position Damper R= Cu/Cu-Al/Cu—Louvered Hail Guard - Powered 115 Volt Convenience Outlet S= Cu/Cu-Cu/Cu—Louvered Hail Guard C14312 4 ' Table 1—FACTORY-INSTALLED OPTIONS AND FIELD-INSTALLED ACCESSORIES CATEGORYFACTORY FIELD ITEM INSTALLED INSTALLED OPTION ACCESSORY Cabinet Thru—the—base electrical or gas—line connections X X Hinged Access Panels X Cu/Cu indoor and/or outdoor coils 5 X Coil Options Pre—coated outdoor coils 5 X Premium,E—coated outdoor coils 5 X Humidity Control Humidi—MiZer Adaptive Dehumidification System 5 X Condenser Protection Condenser coil hail guard(louvered design)5 X X Thermostats,temperature sensors,and subbases X PremierLink DDC communicating controller X X Controls RTU Open multi—protocol controller X Smoke detector(supply and/or return air) X Time Guard II compressor delay control circuit X Phase Monitor X Y EconoMi$er IV for electro—mechanical controls — Non FDD vm (Standard air leak damper models)5,s X X EconoMi$er2 for DDC controls,complies with FDD(Standard Economizers and Ultra Low Leak air damper models)5,7 X X &Outdoor Air Motorized 2 position outdoor air damper 5 X X Dampers Manual outdoor air damper(25%and 50%) X Barometric relief 1 X X Power exhaust X EconoMi$er X for electro—mechanical controls,complies with FDD.(Standard and Ultra Low Leak air damper models)5,6 X X Single dry bulb temperature sensors 2 X X Economizer Differential dry bulb temperature sensors 2 X Sensors Single enthalpy sensors 2 X X & Differential enthalpy sensors 2 X KG Devices Wall or duct mounted CO2 sensor 2 X Unit mounted CO2 sensor 2 X Propane conversion kit X Stainless steel heat exchanger X Gas Heat High altitude conversion kit X Flue Shield X Flue Discharge Deflector X Indoor Motor&Drive Multiple motor and drive packages X Low Ambient Winter start kit 3 X Control Motormaster®head pressure controller 3 X Convenience outlet(powered)5 X Opt ons Convenience outlet(un—powered) X Non—fused disconnect 4 X Roof Curbs Roof curb 14—in(356mm) X Roof curb 24—in(610mm) X NOTES: 1. Included with economizer. 2. Sensors used to optimize economizer performance. 3. See application data for assistance. 4. Available on units with MOCP's of 80 amps or less. 5. Not available as factory installed option on single phase(208/230/1/60)models.Use field—installed accessory where available. 6. FDD(Fault Detection and Diagnostic)capability per California Title 24 section 120.2. 7. Models with RTU Open DDC controls comply with California Title 24 Fault Detection and Diagnostic(FDD).PremierLink is non FDD. 5 FACTORY OPTIONS AND/OR ACCESSORIES Economizer Power Exhaust with Barometric Relief Economizers save energy, money and improve comfort Superior internal building pressure control. This field levels in the conditioned space. They bring in fresh, installed accessory may eliminate the need for costly, outside air for ventilation; and provide cool outside air to external pressure control fans. cool your building. This also is the preferred method of low ambient cooling. When integrated with CO2 sensors, PremierLink, DDC Controller economizers can provide even more savings by coupling This CCN controller regulates your rooftop's performance the ventilation air to only that amount required based on to tighter tolerances and expanded limits, as well as space occupancy. Economizers are available, installed and facilitates zoning systems and digital accessories. It also tested by the factory, with either enthalpy or temperature unites your Carrier HVAC equipment together on one, dry-bulb inputs. There are also models for coherent CCN network. The PremierLink can be factory electromechanical and direct digital controllers. Additional sensors are available as accessories to optimize installed,or easily field installed. the economizer. Economizers include gravity controlled RTU Open,Multi-Protocol Controller barometric relief that helps equalize building pressure and Y ambient air pressures.This can be a cost effective solution Connect the rooftop to an existing BAS without needing co to prevent building pressurization. Economizers are complicated translators or adapter modules using the RTU Open controller. This new controller speaks the 4 most available in Ultra Low Leak and standard low leak versions. common building automation system languages (Bacnet, Modbus, N2, and Lonworks). Use this controller when CO2 Sensor you have an existing BAS. Improves productivity and saves money by working with Time Guard II Control Circuit the economizer to intake only the correct amount of outside air for ventilation.As occupants fill your building, This accessory protects your compressor by preventing the CO2 sensor detects their presence through increasing short-cycling in the event of some other failure, prevents CO2 levels, and opens the economizer appropriately. the compressor from restarting for 30 seconds after stopping. Not required with PremierLink, RTU Open, or When the occupants leave, the CO2 levels decrease, and authorized commercial thermostats. the sensor appropriately closes the economizer. This Motorized 2-Position Damper intelligent control of the ventilation air, called Demand Control Ventilation (DCV)reduces the overall load on the The new Carrier 2-position,motorized outdoor air damper rooftop,saving money. admits up to 100%outside air. Using reliable,gear-driven technology, the 2-position damper opens to allow Smoke Detectors ventilation air and closes when the rooftop stops,stopping Trust the experts. Smoke detectors make your application unwanted infiltration. safer and your job easier. Carrier smoke detectors Manual OA Damper immediately shut down the rooftop unit when smoke is detected. They are available, installed by the factory, for Manual outdoor air dampers are an economical way to supply air,return air,or both. bring in ventilation air. The dampers are available in 25% and 50%versions. Louvered Hail Guards Optional Humidi-MiZer Adaptive Sleek, louvered panels protect the condenser coil from Dehumidification System hail damage,foreign objects,and incidental contact. Carrier's Humidi-MiZer Adaptive Dehumidification System Convenience Outlet (powered or un-powered) is an all-inclusive factory installed option that can be Reduce service and/or installation costs by including a ordered with any WeatherMaker 48KC*B04-06 rooftop unit. convenience outlet in your specification. Carrier will This system expands the envelope of operation of install this service feature at our factory. Provides a Carrier's WeatherMaker rooftop products to provide convenient, 15 amp, 115v GFCI receptacle with "Wet in unprecedented flexibility to meet year round comfort Use" cover. The "powered" option allows the installer to conditions. power the outlet from the line side of the disconnect or load side as required by code.The"un-powered"option is The Humidi-MiZer adaptive dehumidification system has to be powered from a separate 115/120v power source. the industry's only dual dehumidification mode setting. The Humidi-MiZer system includes two new modes of Non-fused Disconnect operation. This OSHA-compliant, factory installed, safety switch allows a service technician to locally secure power to the rooftop. 6 FACTORY OPTIONS AND/OR ACCESSORIES (cont.) Opt.Humidi-Wer Adap. Dehum. Sys. (cont.) Hinged Access Panels The WeatherMaker 48KC*B04-06 rooftop coupled with Allows access to unit's major components with the Humidi-MiZer system is capable of operating in specifically designed hinged access panels. Panels are: normal design cooling mode, subcooling mode, and hot filter,control box,fan motor, and compressor. gas reheat mode.Normal design cooling mode is when the unit will operate under its normal sequence of operation Flue Discharge Deflector by cycling compressors to maintain comfort conditions. The flue discharge deflector is a useful accessory when flue gas recirculation is a concern. By venting the flue Subcooling mode will operate to satisfy part load type conditions when the space requires combined sensible and discharge upwards,the deflector minimizes the chance for a higher proportion of latent load control. Hot Gas Reheat a neighboring unit to intake the flue exhaust. mode will operate when outdoor temperatures diminish Optional Stainless Steel Heat Exchanger and the need for latent capacity is required for sole humidity control. Hot Gas Reheat mode will provide The stainless steel heat exchanger option provides the neutral air for maximum dehumidification operation. tubular heat exchanger be made out of a minimum 20 gauge type 409 stainless steel for applications where the Motormaster Head Pressure Controller mixed air to the heat exchanger is expected to drop below V The Motormaster motor controller is a low ambient, head 45°F (7°C). Stainless steel may be specified on pressure controller kit that is designed to maintain the applications where the presence of airborne contaminants unit's condenser head pressure during periods of low require its use (applications such as paper mills) or in ambient cooling operation. This device should be used as areas with very high outdoor humidity that may result in severe condensation in the heat exchanger during cooling an alternative to economizer free cooling when economizer usage is either not appropriate or desired. The operation. Motormaster will either cycle the outdoor fan motors or Flue Discharge Heat Shield operate them at reduced speed to maintain the unit operation, depending on the model. The flue discharge heat shield keeps people from touching the rooftop unit's potentially hot flue discharge. This is Winter Start Kit especially useful for ground level applications, where more, untrained people could have access to the unit's exterior. The winter start kit by Carrier extends the low ambient limit of your rooftop to 25°F(-4°C).The kit bypasses the Alternate Motors and Drives low pressure switch, preventing nuisance tripping of the low pressure switch. Other low ambient precautions may Some applications need larger horsepower motors, some still be prudent. need more airflow,and some need both. Regardless of the case, your Carrier expert has a factory installed Propane Heating combination to meet your application.A wide selection of Convert your gas heat rooftop from standard natural gas motors and pulleys (drives) are available, factory operation to propane using this field installed kit. installed, to handle nearly any application. High Altitude Heating Thru-the-Base Connections High altitudes have less oxygen, which means heat Thru-the-base connections, available as either an exchangers need less fuel. The new gas orifices in this field accessory or as a factory option, are necessary to ensure installed kit make the necessary adjustment for high altitude proper connection and seal when routing wire and piping applications. They restore the optimal fuel to air mixture and through the rooftop's basepan and curb. These couplings maintain healthy combustion at altitudes above 2000 ft eliminate roof penetration and should be considered for (610m).Kits may not be required in all areas. gas lines,main power lines, as well as control power. 7 ' Table 2-AHRI COOLING RATING TABLE NET NOM. TOTAL UNIT COOLING CAPACITY COOLING POWER SEER EER STAGES (TONS) CAPACITY (MBH) 48KC**04 1 3 35.4 3.0 14.0 12.00 48KC**05 1 4 47.5 4.0 14.0 12.00 48KC**06 1 5 58.5 4.9 14.1 12.00 LEGEND NOTES: AHRI - Air Conditioning,Heating and Refrigeration 1. Rated in accordance with AHRI Standard 210/240. Institute Test Standard 2. Ratings are based on: ASHRAE - American Society of Heating,Refrigerating Cooling Standard:80°F(27°C)db, 67°F(19°C) wb indoor and Air Conditioning,Inc. air temp and 95°F(35°C)db outdoor air temp. EER - Energy Efficiency Ratio 3. All 48KC units comply with ASHRAE 90.1 and Department of SEER - Seasonal Energy Efficiency Ratio Energy(DOE)Energy Standard for minimum SEER and EER requirements. 4. 48KC units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and A■.0 p local codes. �� ru...1 CERTIFIED m ,:t• C liCk Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the •�:P program For verification of certification for individual products,go to www.ahridirectoryorg. COMP Table 3-HEATING RATING TABLE-NATURAL GAS&PROPANE AL/SS HEAT EXCHANGER THERMAL UNITS GAS HEAT TEMP RISE EFFICIENCY AFUE INPUT/OUTPUT INPUT/OUTPUT (DEG 9 (96) STAGE 1 (MBH) STAGE 2(MBH) (%) LOW - 65/50 25-55 82.0% 81.0% 04 MED - 90/73 45-85 82.0% 81.2% m HIGH - - - - - aLOW - 65150 20-55 82.0% 81.0% m 05 MED - 90/73 30-65 82.0% 81.2% c HIGH - 130/105 45-80 82.0% 81.0% co LOW - 65/50 15-55 82.0% 81.0% 06 MED - 90/73 25-65 82.0% 81.2% HIGH - 130/105 35-80 82.0% 81.0% LOW - 72/56 25-55 82.0% N/A 04 MED 82/66 115/89 55-85 80.0% N/A HIGH - - - - tLOW - 72/56 25-55 82.0% N/A m05 MED - 115/90 35-65 81.0% N/A = HIGH 120/96 150/117 50-80 80.0% N/A ~ LOW - 72/56 20-55 82.0% N/A 06 MED - 115/90 30-65 81.0% N/A HIGH 120/96 150/117 40-80 80.0% N/A NOTES: Heat ratings are for natural gas heat exchangers operated at or below 2000 ft (610 m).For information on propane or altitudes above 2000 ft (610 m),see the Application Data section of this book.Accessory Propane/High Altitude kits are also available. In the USA the input rating for altitudes above 2000 ft(610m)must be derated by 4%for each 1000 ft(305 m)above sea level.In Canada, the input rating must be derated by 10%for altitudes of 2000 ft(610 m)to 4500 ft(1372 m)above sea level. 8 Table 4-HEATING RATING TABLE-LOW NOR' LOW NOx HEAT EXCHANGER UNIT GAS TEMP RISE THERMAL AFUE HEAT INPUT/OUTPUT INPUT/OUTPUT (DEG F) EFFICIENCY(%) (%) STAGE 1 (MBH) STAGE 2(MBH) LOW - 60/47 20-50 82.0% 81.3% 04 MED - 90/72 30-60 82.0% m 81.5% z HIGH - - - - - o. LOW - 60/47 20-50 82.0% 81.3% t05 MED - 90/72 30-60 82.0% 81.5% HIGH - 120/97 40-70 82.0% 81.3% 13) c LOW - 60/47 15-50 82.0% 81.3% m 06 MED - 90/72 25-60 82.0% 81.5% HIGH - 120/97 35-70 82.0% 81.3% NOTE: 1. Units meet California's South Coast Air Quality Management District(SCAQMD)Low-NOxemissions requirement of 40 nanograms per joule or less. 0 - Not Applicable Y co cr Table 5-SOUND PERFORMANCE TABLE UNIT COOLING OUTDOOR SOUND(dB)@60HZ STAGES A-WEIGHTED 63 125 250 500 1000 2000 4000 8000 A04 1 76 78.2 78.0 74.2 73.3 70.6 66.0 62.4 56.9 A05 1 81 90.9 84.6 79.5 77.9 76.5 71.1 66.9 62.5 A06 1 77 87.5 82.5 76.1 73.6 71.3 67.1 64.1 60.0 LEGEND NOTES: dB-Decibel 1. Outdoor sound data is measure in accordance with AHRI standard 270. F1E11 TO,pq,, 2. Measurements are expressed in terms of sound power. Do ,p1 e` s not compare these values to sound pressure values because sound pressure depends on specific environmental factors Um 4 f which normally do not match individual applications. Sound '. •z power values are independent of the environment and there- fore more accurate. "e,STAN�Po�° 3. A-weighted sound ratings filter out very high and very low frequencies,to better approximate the response of"average" human ear.A-weighted measurements for Carrier units are taken in accordance with AHRI standard 270.9 9 Table 6—MINIMUM-MAXIMUM AIRFLOW RATINGS-NATURAL GAS&PROPANE VOLTAGE UNIT HEAT COOLING AL HX HEATING SS HX HEATING LEVEL MINIMUM MAXIMUM MINIMUM MAXIMUM MINIMUM MAXIMUM LOW 900 1970 900 1970 48KC**04 MED 900 1500 800 1520 800 1520 HIGH - - - - LOW 900 2470 900 2470 SINGLE 48KC**05 MED 1200 2000 1050 2280 1050 2280 PHASE HIGH 1230 2190 1230 2190 LOW 900 3290 900 3290 48KC**06 MED 1500 2500 1050 2730 1050 2730 HIGH 1230 2820 1230 2820 LOW 990 2190 990 2190 48KC**04 MED 900 1500 1000 1550 1000 1550 HIGH - - - - LOW 990 2190 990 2190 PHASE 48KC**05 MED 1200 2000 1330 2460 1330 2460 HIGH 1390 2220 1390 2220 LOW 990 2730 990 2730 48KC**06 MED 1500 2500 1330 2880 1330 2880 HIGH 1390 2780 1390 2780 10 • Table 7—PHYSICAL DATA (COOLING) 3-5 TONS Refrigeration System 48KC*AJC 48KC*A/805 48KC*A/B06 #Circuits/#Comp./Type 1/1/Scroll 1/1/Scroll 1/1/Scroll Purone refrig.(R-410A)1 phase (lbs—oz) 7-2 10-8 16-0 Puron®refrig.(R-410A)3 phase (lbs—oz) 7-2 10-8 14-8 Humidi—MiZer Puron®refrig.charge(lbs—oz) 10-6 15-5 26-0 Metering Device(A) Acutrol Acutrol Acutrol Humidi—MiZer Metering Device(B) Acutrol+TXV Acutrol+TXV Acutrol+TXV High—press.Trip/Reset(psig) 630/505 630/505 630/505 Low—press.Trip/Reset(prig) 54/117 54/117 54/117 Compressor Capacity Staging(%) 100% 100% 100% Evap.Coil Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8—in RTPF 3/8—in RTPF 3/8—in RTPF Rows/FPI 3/15 3/15 4/15 Total Face Area(ft2) 5.5 5.5 7.3 Condensate Drain Conn.Size 3/4—in 3/4—in 3/4—in Humidi—MiZer®Coil Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8—in RTPF 3/8—in RTPF 3/8—in RTPF Rows/FPI 1/17 2/17 2/17 Total Face Area(ft2) 3.9 3.9 5.2 Evap.Fan and Motor U Motor Qty/Drive Type 1/Direct 1/Direct 1/Direct Standard Max BHP 1 1 1 Static RPM Range 600-1200 600-1200 600-1200 1 pSe Motor Frame Size 48 48 48 Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Medium Max BHP 1.2 1.2 1.5 Static RPM Range 770-1175 770-1175 1035-1466 1 phase Motor Frame Size 48 48 56 Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10x 10 Motor Qty/Drive Type 1/Belt 1/Belt N/A High Max BHP 1.5 1.5 N/A Static RPM Range 1035-1466 1035-1466 N/A 1 phase Motor Frame Size 56 56 N/A Fan Qty/Type 1/Centrifugal 1/Centrifugal N/A Fan Diameter(in) 10 x 10 10 x 10 N/A Motor Qty/Drive Type 1/Direct 1/Direct 1/Direct Standard Max BHP 1 1 1 Static RPM Range 600-1200 600-1200 600-1200 3 phase Motor Frame Size 48 48 48 Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 11 x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Medium Max BHP 1.7 1.7 2.9 Static RPM Range 770-1175 920-1303 1035-1466 3 phase Motor Frame Size 48 56 56 Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt High Max BHP 2.9 2.9 2.9 Static RPM Range 1035-1466 1208-1639 1303-1687 3 phase Motor Frame Size 56 56 56 Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10x 10 10x 10 Cond.Coil 1 phase Material(Tube/Fin) Cu/Al Cu/AI Cu/Al Coil type 3/8—in RTPF 3/8—in RTPF 3/8—in RTPF Rows/FPI 1/17 2/17 2/17 Total Face Area(ft2) 16.5 16.5 21.3 3 phase Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8—in RTPF 3/8—in RTPF 3/8—in RTPF Rows..Fins/in. 1/17 2/17 2/17 Total Face Area(ft2) 16.5 14.6 18.8 Cond.fan/motor Qty/Motor Drive Type 1/Direct 1/Direct 1/Direct Motor HP/RPM 1/8/825 1/4/1100 1/4/1100 Fan diameter(in) 22 22 22 Filters -, RA Filter#/Size(in) 2/16x25x2 2/16x25x2 4/16x16 x2 OA inlet screen#/Size(in) 1/20x24x 1 1/20x24x 1 1/20x24x 1 N/A—Not Available 11 917 ' Table 8—PHYSICAL DATA (HEATING-SINGLE PHASE UNITS) 3 -5 TONS 48KC**04 48KC**05 48KC**06 Electrical Single Phase Single Phase Single Phase Gas Connection #of Gas Valves 1 1 1 Nat.gas supply line press(in.w.g.)/(PSIG) 4—13/0.18—0.47 4—13/0.18—0.47 4—13/0.18—0.47 LP supply line press(in.w.g.)/(PSIG) 11 —13/0.40—0.47 11 —13/0.40—0.47 11 —13/0.40—0.47 Heat Anticipator setting(Amps) 1st stage 0.14 0.14 0.14 2nd stage 0.14 0.14 0.14 Natural Gas Heat #of stages/#of burners(total) 1/2 1/2 1/2 LOW Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT Rollout switch opens/doses 195/115 195/115 195/115 Temperature Rise 25—55 20—55 15—55 U #of stages/#of burners(total) 1 or 2/3 1/3 1/3 Y. co MED Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT cr Rollout switch opens/doses 195/115 195/115 195/115 Temperature Rise 45—85 30—65 25—65 #of stages/#of burners(total) — 1 or 2/3 1 or 2/3 HIGH Connection Size — 1/2—in NPT 1/2—in NPT Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 45—80 35—80 Liquid Propane Heat #of stages/#of burners(total) 1/2 1/2 1/2 LOW Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT Rollout switch opens/doses 195/115 195/115 195/115 Temperature Rise 25—55 20—55 15—55 #of stages/#of burners(total) 1 or 2/3 1/3 1/3 MED Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 45—85 30—65 25—65 #of stages/#of burners(total) — 1 or 2/3 1 or 2/3 HIGH Connection Size — 1/2—in NPT 1/2—in NPT Rollout switch opens/doses — 195/115 195/115 Temperature Rise — 45—80 35—80 Low NOx Gas Heat #of stages/#of burners(total) 1/2 1/2 1/2 LOW Connection Size 1/2—in NPT 1/2—In NPT 1/2—in NPT Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 20—50 20—50 15—50 #of stages/#of burners(total) 1/3 1/3 /3 MED Connection Size 1/2—in NPT 1/2—in NPT 1/2-51in NPT Rollout switch opens/doses 195/115 195/115 19 /115 Temperature Rise 30—60 30—60 25—60 #of stages/#of burners(total) — 1/3 1/3 HIGH Connection Size — 1/2—in NPT 1/2—in NPT Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 40—70 35—70 — Not applicable 12 , Table 9—PHYSICAL DATA (HEATING-THREE PHASE UNITS) 3-5 TONS 48KC**04 48KC**05 ** 48KC 06 Electrical Three Phase Three Phase Three Phase Gas Connection #of Gas Valves 1 1 1 Nat.gas supply line press(in.w.g.)/(PSIG) 4—13/0.18—0.47 4—13/0.18—0.47 4—13/0.18—0.47 LP supply line press(in.w.g.)/(PSIG) 11 —13/0.40—0.47 11—13/0.40—0.47 11 —13/0.40—0.47 Heat Anticipator setting(Amps) 1st stage 0.14 0.14 2nd stage 0.14 0.14 0.14 0.14 Natural Gas Heat #of stages/#of burners(total) 1/2 1/2 1/2 LOW Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 25—55 25—55 20—55 #of stages/#of burners(total) 1 or 2/3 1/3 1/3 0 MED Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT c0 Rollout switch opens/doses 195/115 195/115 195/115 Temperature Rise 55—85 35—65 30—65 #of stages/#of burners(total) — 1 or 2/3 1 or 2/3 HIGH Connection Size — 1/2—in NPT 1/2—in NPT Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 50—80 40—80 Liquid Propane Heat #of stages/#of burners(total) 1/2 1/2 1/2 LOW Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT Rollout switch opens/doses 195/115 195/115 195/115 Temperature Rise 25—55 25—55 20—555 #of stages/#of burners(total) 1 or 2/3 1/3 1/3 MED Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 55—85 35—65 30—65 #of stages/#of burners(total) — 1 or 2/3 1 or 2/3 HIGH Connection Size — 1/2—in NPT 1/2—in NPT Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 50—80 40—80 Low NOx Gas Heat #of stages/#of burners(total) 1/2 1/2 1/2 LOW Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 20—50 20—50 15—50 #of stages/#of burners(total) 1/3 1/3 1/3 MED Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT Rollout switch opens/doses 195/115 195/115 195/115 Temperature Rise 30—60 30—60 25—60 #of stages/#of burners(total) — 1/3 1/3 HIGH Connection Size — 1/2—in NPT 1/2—in NPT Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 40—70 35—70 - Not applicable 13