Loading...
Plans 4,4- 11 51-90/ 8 - 6)06.5-0 /(6 I( s ii,t) s tie 1,4-,d4 Le s-7- f "RIVER TERRACE EAST" LOT 90 HUB AND TACK CERTIFICATION NE & SE 1/4 SEC. 6, T 2 S, R 1 W, W.M. CITY OF TIGARD, WASHINGTON COUNTY, OREGON SURVEYED MARCH 14. 2018 PREPARED FOR: POLYGON NORTHWEST COMPANY SW SNOWDALE STREET 703 BROADWAY ST., SUITE 510 VANCOUVER, WA. 98660 - — — — — — — i() 0 4 S89'58'43"E 50.00' 0 0 0 0 E ' $2 6' PUBLIC UTILITY EASEMENT F.: b 0 0 ,...... 0 0) 0. 0 5.00-1P- LLI LOTL3,1 a LOT w r--, LOT ,.=. 89 ts, 90 , - 91 LIJ f5-V) P 0 0) . 0 0 t . 0 z z c 0 6 s , REGISTERED PROFESSIONAL o LAND SURVEYOR <0 No-- 0 0 i \\ < OREGON ,-- JULY 9,2002 a.. S89.58431°E 50.00' ..- ›, TRAVIS C.JANSEN 0 z 57751 (rii;14 .0 0 RENEWS;6/30/2019 .g) I, TRAVIS C, JANSEN, A REGIS IERED PROFESSIONAL LAND SCALE 43 SURVEYOR IN THE STATE OF OREGON, HEREBY CERTIFY THAT 2,0 0 10 20 I HAVE ACCURATELY SURVEYED AND STAKED THE OFFSETS 1.11=1111/mil.6.0.111111.11.111 TO THE FOUNDATION ENVELOPE FOR LOT 90 OF THE PLAT 1 INCH =20 FEET OF "RIVER TERRACE EAST", 2" DRAWN BY: FAA DATE: 3/15/18 fr) PACIFIC COMMUNITY DESIGN T REVIEWED BY: CJ DATE: 3/15/18 ..< PLANNING - ENGINEERING - SURVEYING Z , PROJECT NO.: 395-041 \-.. (503) 941-9484 ..1 GEODES IGNk FIELD REPORT Page 1 of 2 GDI Project: Polygon-129-03 Prepared By: Bret Moskal Project Name: River Terrace East Date: 3/22/18 Location: SW Scholls Ferry&Roy Rogers, Bvrtn. Report#: 216 Arrival: 1040 Departure: 1100 Weather: Overcast, 40's Permit#: TBD ........................ Site Visit Requested By: Ken (Polygon) Met With (on site): Ken (on phone) Purpose: Observe lot 90 subgrade Outstanding Issues: Proof roll road and curb base rock and repair as needed before paving FR-58 (12/06) Decommission temporary storm and sewer lines through Tract E FR-177 soft fill from slope cut in lots 153, 154 and 155 FR-214 (03/20/18) Low density backfill for lot 200 Upon arrival, I observed earthwork crew had prepared lot subgrade for lot 90 and placed approx. 2"to 6"of compacted crushed rock on the surface. Using a Y2"diameter steel foundation rod I probed the subgrade through the compacted aggerate base. Probing resistance indicated stiff subgrade. I observed the aggerate base to appear well-keyed and firm underfoot. Based on our observations and probing, it is our opinion that subgrade areas for lot 90 indicated, where observed today and indicated on attached site plan, been prepared in general accordance with our geotechnical recommendations. Distribution: Attachments: Site Plan (1) Reviewed by: This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services. We rely on the contractor to comply with the plans and specifications throughout the duration of the project irrespective of the presence of our representative. Our work does not include supervision or direction of the contractor,the contractor's employees or agents. Our firm is not responsible for site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations.The report can only be considered final upon review of the GeoDesign project manager,as indicated by initials in the"Reviewed By'section. Signature: 9450 SW Commerce Circle,Suite 300 I Wilsonville,OR 97070 1503.968.8787 I www.geodesigninc.com