Report (24) fns/0 o j'7 'J.2 I ( L/4-1 s L c2 kin G W b,,t 1-31 c..
Form 6405 2017 .
Completion Certification—Site Inspection
New Homes Program—Single Family EnergyTrust
of Oregon
To be completed by Verifier
CLEAResult is a Program'Management Contractor for Energy Trust of Oregon,Inc.
1?* enf In tl A..,.., .. ... .,. ,..A �. ,. .
Incentive Payee Company Name:
[William Lyon Homes Is this payment redirected?: AINo
Builder or Company: William Lyon Homes Redirect to Name:
Verifier Payee Company Name: Performance Insulation and Energy Redirect Payee Com
Affordable Housing No
Solar Ready Builder Incentive: No (Solar ReadyVerifier IncelNo
Development NE River-Area 3-Alley Lot As ID: I REM/Rate®ID.
Address: ' -1vM "'
Street Line 2 Muni-Family No City: Tigard State: OR Zip: 97224
Total conditioned area(sq.ft.): 2,065 House Volume. I 18,405 Housing Type: Detached single family
Number of Stories: I2 Number of Bedrooms: 4 Foundation Type: Crawlspace
Electric Provider: Portland General Electric Gas Provider: INW Natural Gas
Solar installed None Solar Installer Name/Company:
u
,....
Blmad far'irvpO.sheaf
Slab Perimeter Insulation R- 0.0 Slab Under Insulation R-
InsuWtion Framed Floor R- 30.0 Secondary Framed Floor R- 59.0
Above Grade Wall Insulation R- 23.0 Below Grade Wall Insulation R-
Flat Ceiling Insulation R- 49.0 Vaulted Ceiling Insulation R-
Windows Windows U- ammo 0.3 Total window area: 314
Coding Air Conditioning SEER: 0 Model#:
Pdmary Heating System Details AFUE: Bryant
Type: Gas Furnace HSPF: Model#: 8126C36040517'
Heating Fuel: Gas SEER:
Primary Heat
Source Comment: COP:
Location: Condltioned A Outdoor Unit(for heat pumps)
ECM: No Model#:
AHRI Certificate:7126229 #of Systems 1
Gallons: MIME=AOSmilh
Water Heater Type Storage EF: Model#: HPTU-50N 120
Water Heating Fuel Electric Location: Garage or ope
Ducts and Duct Location Conditioned %ducts inside: `��'f� Duct Leakage(CFM)(8 50Ra: "�,•
..
Testing
Infiltration Air Changes per Hour(ACH) 50Pa: 3.22
Vemilation Ventilation Type HRV/ERV Model:
Supply Side-Air Cycler Airflow measured or why untestable? (Roof Termination
Refrigerator Ig
kWh/yr Model:
ENERGY STAR Diswasher kWh/yr 268 Model: FGID2466'•'A
Percent High Efficacy Interior Lighting(%) 100% Thermostat
Showerhead 1.5 GPH I Showerwand 1.5 GPH I Showerhead 1.6 GPH I IShowerhead 1.75 GPH I
....,ittslog4 $,,„
New Water Heater Model:
•
•
• Oregon Residential Specialty Code 4408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
kiki6 is (1) QJSflSJ J, am the general contractor or the owner-builder
at the following address:
Site Address: 1 E Q l{cf 9,0 J, a,-•1 G rl.A-s s LA-
City: tint o F dada"-O •
Permit#: M/1 S'r20/ 7- - 6042-2-
Subdivision/Lot
oo422Subdivision/Lot#: 1 1(04 t 1- pluw,/-,69Apc
and/or 1�1
Map and Tax Lot#: 2_4,4
To conform with the 2014 Oregon Residential Specialty Code(ORSC),Section R408.1
Ventilation.I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
req I—let:
`T4 The ground surface of the under floor space is covered with 6-mil black polyethylene
shee •t
J.'' ' lapped 12"at seams and
V Extending up the foundation walls 12".
Signalize: / i Date: j I8
ignat�e:
L1BuildmgTotm\REs-Moi$tU,eB.ai .ddoc 09/13/2016
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: MST 2-0/ - oo Z Jurisdiction: 6-rua t*I, C'n' `"',
Site Address: 1 to D Li 4 1.4-Ase
Subdivision/Lot#: )se
iti -1;eit.dope
and/or ll
Map and Tax Lot#: so4
By my signature below,I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent,or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: jdli
Date: 05 n\\5
/Authorized Agent
•
Print Name: 'u pc Orttseraft.
i ORSC Section N11072.High-efficiency interior lighting systems. A mins—muni of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumen per input watt. Screw-in-in compact fluorescent lamps comply with this
requirement
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fnctnres are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
inert watt
•
L; ormS-HighElfCiwcyla�Ogdoc 07ro1/O8
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, [6,E-LA. ( ruij . am the general contractor or the owner-builder
at the following address:
Site Address: , to 644 /,GU A - D,Lt [s:4A--`6S h
City: 0111- �" Ti a Al
Permit#:
Subdivision/Lot#: 1 ►urn4 Ei c 1 1? W1L �` A Ce
and/or ,fit
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC),Section R318.2 and
OAR 918-480-0144,I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R3182 and have taken steps to meet this code requirement
[Section R3182 is provided for reference].
R318.2 Moisture Content Prior to the installation of interior finishes,the building
official ial shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry flaming members.
,
Signature: �i JA1. _____
41/iiDate: o 'LlC
•
L ana "vewood.doc 09/25/08