Loading...
Report (76) 4 11 r 20/2 Yrs � . . E Date: November 28, 2017 DEC L, 2017 MORRISON HERSHFIELD Mr. Michael Murray c Y CF , 4 o Morrison Hershfield Crown Castle MAC,. f � 1455 Lincoln Parkway, Suite 500 2055 S. Stearman Drive Atlanta, GA 30346 Chandler, AZ 85286 (770) 379-8500 Subject: Structural Opinion Letter Carrier Designation: Verizon Wireless Co-Locate Carrier Site Number: 172114 Carrier Site Name: POR Barrows Crown Castle Designation: Crown Castle BU Number: 855864 Crown Castle Site Name: Scholls Ferry Beef Bend Crown Castle JDE Job Number: 472523 Crown Castle Work Order Number: 1494305 Crown Castle Application Number: 416333 Rev.4 Engineering Firm Designation: Morrison Hershfield Project Number: CN4-226R2/ 1800030 Site Data: 17026 SW Friendly Lane, Beaverton,Washington Co.,OR 97007 Latitude 45°25'32.01", Longitude-122°51'7.53" 78.5 Foot—FWT Monopole Tower Dear Mr. Murray, Morrison Hershfield is pleased to submit this"Structural Opinion Letter" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural `Statement of Work' and the terms of Crown Castle Purchase Order Number 1111712, in accordance with application 416333, revision 4. The purpose of this opinion letter is to determine the suitability of the tower with the proposed and existing loading as specified in Tables 1 and 2 on the next page. This opinion is consistent with the guidelines as stated in the ANSI/TIA-222-G standard and the 2014 Oregon Structural Specialty Code (OSSC) based upon an ultimate 3-second gust wind speed of 120 mph converted to a nominal 3-second gust wind speed of 93 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure Category C with a maximum topographic factor, Kit, of 1.0 and Risk Category II. Based on a comparison of the previous' analysis loads (including wind speeds), the current loads and the proposed loads, we have determined the tower structure and foundation ARE sufficient for the proposed loading. We at Morrison Hershfield appreciate the opportunity of providing our continuing professional services to you and Crown Castle. If you have any questions or need further assistance on this or any other projects please give us a call. Respectfully submitted by: t -- Azz,cot.1 ,t ff 58474 Shawn W. Stevenson, S.E. (OR License No. 58474) Senior Engineer au Go t I 5g F , ',,,at 1 301,201e5 'Refer to the previous structural analysis completed by Morrison Hershfield,Project No.CN4-226/6150003,Dated 02/03/2015 . 4 November 28, 2017 78.5 Ft Monopole Tower Structural Opinion Letter CCI BU No. 855864 Project Number CN4-226R2/1800030,Application 416333,Revision 4 Page 2 Table 1 -Proposed Antenna and Cable Information Center NumberNumber Feed Mounting Line Antenna Line Antenna Model of Feed Note of Level(ft) Elevation Manufacturer Size (ft) Antennas Lines (in) 60.0 60.0 1 1 RFS SC2-190BB 1 1 ? 1/2 -- Table 2-Existing Antenna and Cable Information Center Number Number Feed Mounting Lineof Antenna Antenna Model of Feed Line Note Level(ft) Elevation Manufacturer Size (ft) Antennas Lines (in) 83.0 2 Kathrein 1AP14/17-880/1940/065D/ADT/XXP i w/pipe mount 1 1 1 Kathrein IAP14/17-880/1940/065D/ADT/XXP i w/pipe mount 3 Lucent 3JR52703AAAA w/pipe mount 1 Kathrein 742-265 w/pipe mount 4 j Ericsson i KRY 112 13/1 1 1/4 4* Powerwave � LGP21401 1 3/8 82.082,0 ` 2 Powerwave TT19-08BP111-001 2 3/4 1 6 7/8 2 T Lucent RRH2X40-07-L 6 ' 1-5/8 1 Lucent RRH2X40-07L-AT r 1 rRaycap DC6-48-60-18-8F 1 - Miscellaneous[NA 509-3] 1 - Miscellaneous [NA 510-1] - Platform Mount[LP 1001-1] 81.0 2 Kathrein 742-265 w/pipe mount 3 Antel j BXA-70063/8CF w/pipe mount i 3 Antel j BXA-80080/8CF w/pipe mount 3 T CSS AXP18-80-0 w/pipe mount CSS XP18-80-0 w/pipe mount 60.0 60.0 6 i Andrew 850/1900 DUAL BAND TMA 12 7/8 1 r 3 Ericsson RRUS 12 B4 1 1-1/4 r f-T Raycap - RCMDC-3315-PF-48 3 Rosenberger j FB-15-ABOX 3 - T-Arm Mount[TA 701-1] 37.0 1 T GPS GPS_A 36.0 36.0 1 - j LL Side Arm Mount[SO 701-1] 1 1/2 I 1 Notes: 1) Existing Equipment. CUMBING PEGS W/SAFELY CUMB • (INSTALLED) —— (1) 1/2•TO 38 FT LEVEL / (PROP0SEO-TEMPORARY) 1 1/4•TO 82 FT LEVEL / N (1) 1/2'TO 60 FT LEVEL 1) 3/8'TO 82 FT LEVEL 2 3/4'TO 82 Fi LEVEL / \ + (1 7u%B(INSTALLED) 60 FT LEVEL. 6) 7/8'TO 82 FT LEVEL • / / — 1:\ 1) 1-1/4'TO 60 FT LEVEL (6) 1-5/8'TO 82 FT LEVEL C.:. • / / \ ( . 1 / \ \ 1 / a \ \ 1 eiro a ' y o0 1 I \ \ / I \ \ / I \\ \�`— �/ // N / N i -,.----- BUSINESS UNIT:855864 TOWER ID:C_BASELEVEL N