PFI2018-00046 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
= COMMUNITY DEVELOPMENT Permit#: PF12018-00046
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 03/05/2018
Parcel: SEG2276
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: PGE
Project Description: SEG 2276/2277. Replace 3 phase between vault 6984 and vault 6983. Change C phase lateral in vault
6984. M2430961.
Owner: FEES
Description Date Amount
PHONE:
Contractor:
PHONE:
FAX:
Applicant:
TOM COX
10800 SW AVERY STREET
TUALATIN, OR 97062
PHONE: 503-612-2935
Total $0.00
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant V-(,
Signature: ) ' G0�GL �w
Issued By: +
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12018-00046
Type: Condition Name: Status: Severi
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of
any agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited
and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up
and suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be
reinstalled or replaced,with like kind of material. Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition, American Traffic Safety Services
Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work
area. Traffic control devices, flag persons, etc.,shall be in place prior to initiation of construction work and shall be
effectively maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and
area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met)
and 503-431-2345(Tigard School District)and other service providers impacted by such closure.
PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the
City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized
by the City Engineer.
PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987.
If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole
before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at
the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work
with affected utility agencies.
PFI_Utilities 14-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by
the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert
Phone#>, to establish a preconstruction meeting.
PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged
inspection, and after completing work covered by the permit.
PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 19-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have
authority to resolve problems,take corrective action and, in general, will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI_Utilities 21 -OTHER Applied Notice
RECEIVED
City of Tigard FEB 2 6 2018
N PUBLIC `STORKS—ENGINEERING CITY OF TIGARD
L NING/EN-GINEERING
provement Public FadhtyIm (PF ern�t
TYPE OF WORK
DESCRIPTION OF WORK(in the right-of-way)
TYPE 1—Franchise Utility Work
Check one: Utilities ❑Sidewalk/driveway approach ❑Streetimprovements performed by NWN, PGE
Detailed description: Replace 3 phase between vault 6984 and vault and/or utility agency.
6983. Change a phase lateral in vault 6984. ❑ TYPE 2—Sidewalk/Driveway/Sewer
PGE Job M2430961 Work performed for the purpose of-
- Sidewalk installation or repair.
15695 SW Old Orchard Place
Property address/location(s): - Driveway approach installationand/or repair
2� Tigard,OR 97224 - Sanitary sewer lateral installation
and/or main line tap
Applicant: Portland General Electric[Submitted by Amy Sweany] ❑ TYPE 3—Full scale Development
Work performed with Land use
Address: 10800 SW Avery Street approval which includes any of
City/state: Tualatin,OR Zip: 97062 the following
Phone: 503-612-2935 Email: preregcoord@pgn.com - Subdivisions or Partitions
Ph
Contact name: one:
SDPM Tom Cox 503-736-5419 - Streetwidening
- Mainline installation for Sanitary
Contractor: PGE approved contractor TBD after bid walk. sewer, Storm sewer,Tigard water
and/or Tigard Water Service Area
CCB#: Expiration:
Address: SUBMIT COMPLETED APPLICATION TO:
City/state: Zip: City of Tigard
Planning/Engineering
Phone: Email: 13125 SW Hall Blvd.
Contact name: Phone: Tigard,OR 97223
Applications for"tnuior work in right-of-way"
Engineer. NSA only may be emailed to:
ronRermitsQ.jjg` ar�gov
Address:
City/state: Zip:
Phone: Email: Case No.:
Contact name: Application submittal fee(.007%of
Engineer's Estimate) _
Estimated value of work is required(if over$5,000):$ 39,396.74 Additional fees: pz� `
(within the public right-of-way) Application accepted: �7
By: Date: b
Is work related to a LAND-USE DECISION? ❑ Yes No
If so,please specify (MLP,SDR,SUB,etc.) case#: Applicadoreviewed:' Date:
ate:
Is work related to a BUILDING PERMIT? ❑ Yes R( No Applicant notified: ll
If so,please specify(BUILDING PERMIT)case#: By: �' Date: 3 1'5 I I
I:\EM\PermitAppikations\pfl pppliation Rev.10/16/2017
City ofTigard - 13125 SW Hall Blvd. - Tigard,Oregon 97223 - -'vw\vtigard-or.gov - 503-718-2421 - Page 1 of4
APPLICANTS
NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if
required by the city pursuant to TMC 15.041.140.
* With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different
people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the
owner. The owner(s)must sign this application in the space provided or submit a written authorization with this application. Franchised
Utilities are not required to obtain the owner's signature on the application
BY SIGNING BELOW,THE APPLICANTS)SHALL CERTIFY THAT:
• The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject
Prop9'•
• If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
• All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and
the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such
statements are false.
• The applicant has read the entire contents of the application,including the policies and criteria,and understands the
requirements for approving or denying the application.
Q��LQ "%Jv-S\-\ 23 6CJ18
Applicant/Authorized Agent's signature Print name 4ae
SIGNATURES of each owner of the subject property, if required.
Owner's signature Print name Date
Owner's signature Print name Date
Owner's signature Print name Date
PUBLIC FACILITY IMPROVEMENT PERMIT
City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 2 of 4
www.invarion.com
Lane Closure at lnterseetion with Flagging Diagram 620
ROAD
wow
GNP LAN1
can MAD
MEAD
B
BE
rRrtr�Rm
10 STOP
B
10
A v )
o aRa
ROAD
100 R.Max r1eBE AHEAD READ
° Toara WORK
O
A B B C LL
BuM1r n � r
4- o
coon
0
o o �
� K � II o
100 fl MAK—{
C B B A I II
O
*4
OAD �a o
WONIX rREPARED
TO aTOr 100 R MRx
ONE LAW •
ROAD U
MEAD
oveb�e o A
•
B
9E
rEEPARED
TO aror
B lovl
ow wa
T pOAD
C ARM°
ROAD
WORK
www.invaHon.com
Lane Gilds ire at Intersection with Flagging tMagram 8Zt1
Diagram 620 covers work within an Intersection when normal traffic control
must be interrupted.Work vehicles may or may not be in the work space_
1.During flagging,traffic signals shall be turned off.Contact the road
jurisdiction for approval and assistance(see Chapter 3).
2.For multi-lane facilities,traffic approaching the intersection shall be
reduced to a single lane on each approach.See Chapter 3 for
information on flagging through intersections.
3.There should be one flagger for each approach.One flagger may
control two adjacent approaches if sight distance,low volumes on side
roads,and flagger position allows for safe operation and clear direction
to motorists.For low traffic volume intersections(fewer than 400
entering vehicles per day),one flagger may be used.
4.The'ONE LANE ROAD AHEAD"(W20-4)sign is optional and should
be considered on high volume or high speed roads,or when extended
queues may be expected.
Sign Spacing and Buffer Lengths(feet)
Spacing a SlIgns Buffer
S A B C S ERRATA:
20 50
25 100 100 100 75 Supplement Table
30 100
35 125 Updated:February 12,
350 350 350
40 150 zola
45 180 By:NOT Tran c-RAod"y
50500 500 500 210 section
55 250
Signs Spacing and Buffer Lengths(feet)Supplement
Posted S.pacing 13etween S na "Buffer"
Speed A B C -1i Space'
60 285
65 700 700 700 325
70 365
aOcum 6N0 �I
m Single Flagger Operation0
for Low Volumes (Optional}
UP a �
(ADT<400) BE
F{ ONE LANE
PREPARE
ROAD
1 To stop AHEAD
a y ® ROAD (7
�, I c s • WORK
c
wA
Ati4
loo oro,
L1 mile _l
4M I- max.
—r -Q p 0 0 0-v^0 0 m
�y 0000 ® 000
C B
Buffer
Protection Vehicle
ROAD 0 w/TMA(both Optional) :.
WORK See Chapter 4
ONELAME 9E
ROAD PREPARED Two Flagger Operation
AHEAD MSTOP
w
(Optional) Q
c
d
0
3
www.invarion.com
Stationary Lane Closure with Flagging diagram 320
Diagram 320 covers total closure of one lane of a two-lane,two-way
roadway.See the detail inset for the layout If using a single flagger to control
both directions of traffic on low volume roads(less than 400 ADT)with good
sight distance as discussed below.
1.Use truck-mounted flashing warning lights on work and protection
vehicles.See Section 4.3—Lights and Lighted Signs for exceptions.
2.For added visibility,a truck-mounted arrow board or PCMS in caution
mode may be used.
3.Flaggers at each approach are required if any of the following
conditions exist:
a.Night Operations.
b.Work space is over 200 feet in length.
c.Sight distance is less than 750 feet from each approach
through the lane closure.
d.Traffic volumes are greater than 400 ADT.
4.The length between the Flagger Ahead signs shall not exceed one
mlle.Use Diagram 340—Lane Closure with Pilot Car if exceeding one
mile.
5.Cones should be used to outline the work space when curves or other
roadway alignments prevent dear direction for the motorists to pass
the work space safely.
6_Cones along the work space are recommended when posted speeds
are 45 mph or greater,when working under heavy traffic or when travel
lanes are narrower than 11 feet.
7.Extended queue signing(see Diagram 5-4)should be used when
traffic queues extend beyond the initial advance warning sign.
8.When flagging near an intersection,the"Flagger Ahead"(CW23-2)
sign should be visible to traffic entering from any side road.Additional
advance warning and Flagger Ahead symbol signs may be placed on
the side road(s).
9.Sign set-up and flagger placement shown may be used for Intermittent
full road closures of 20 minutes or less.
10.The"ONE LANE ROAD AHEAD"(W20-4)sign is optional and should
be considered on high volume or high speed roads,or when extended
queues are expected.
10850 LEGEND
10870 10405
_REMOVE/ABANDON FACILITIES_INSTALL FAGIUTIES
10880
_INSTALL ADDITIONAL FACILITIESANOD/FY FACILITIES
1 WORN LOCATIONS
10435 10425 10415 -------- SURVEY GRID BOUNDARY
10890 10455
10505 10445 1 CONDUCTORS
10495 10485 10475 10465
------- IN INSTALL ARCO AL EPR TRIPLEX PRIMARY
WL 1 VT-6983: `PROVIpEp d INSTALLED BY PGE
Install: 1a-CONDUIT
(3)ELBOW KIT-JKTD CABLE-82)0AL `PROVIDED 6 INSTALLED BY PGE APPROVED CONTRACTOF
Ram , ABANDON PRIMARY CABLE
6650 (3)ELBOW KIT-JKTD CABLE-#2/OAL 'GROUND ABANDONED CABLE PER LC22035.7
15535
15625
15645 Syy GREENLEAF T12
E1
EQUIPMENT
25'-Unknown SMALL FAULT INDICATORp)VAR TRIP 200 A
15655 - 1980 TER
Loa 20
15555 10430
B 50 15280 10515
11th
15030
ISEiS P� 1 �� 10440
15685 VT-6906 GN
ARO 10525 ��< 110450
S�00 15640 ;
L
15695 15650
10535
2 C2 1-10D TENSION:522# 1
VT-6984 TENSION:520# A 50 17236 t !
ABC 2/0 AL-_ 8 - _, _647__-_-_� ---_-- ----ABC 2/0 AL-------------------- -------E"'I 3
__ W1 LUBE
7032 .--_-- - 2 AL - 7035 ABC 210 AL ABC 2 AL VT-6983
2s'� 25'-4 1 C21-11C
1974 7033 7034 ts7a SW SUMMERFIELD DR 7037 254 1
♦ 25'-4♦ 25'� ♦ 60 7036 25'-4
1974 1974 ROW ♦ 25'-4♦ 1974♦ 1Y74 A 1 1593
1974 1
1
1 15945
1
�� 15955
LANDSCAPING NOTES
I �
�L PRE-LANDSCAPING
WL 2 VT-6984-CLEAR
10650 5'AROUND VAULT
e
WL 2 VT-6984: 1�
Install: I
(3)ELBOW KIT-JKTO CABLE-#2/0AL s r J
ABC 112 140
Remove: i
(3)ELBOW KR-JKTD CABLE-#2/OAL r
5780 PD-6985
� 15960
1
1
i
15790 i
1
1 � 4
1580'7 7 d �.
( m
0 30 60 1,81120 Feet
I I I I I I I I I e N
I
1-LINE DIAGRAM
�-� VT-4J PD-915 aA 50 VT 151362 m C 50]6156pp_28 pp-29 U i B 5015931 VT-6988 � C 50 28971
3749 D-4 P-902 D 66 8526 C,-� C S 67 C 5015271VT-�91 VI.6990 VT-6989 B 5015926VT 6987 fi9% ABC 112 108pD-6609
A T5 8821 p-72 C 5071 50 � NY DEVIATION FROM THIS DESIGN MUST
ABC 225 27A 11111 PD-85 VT-69921"—C�C I �F I ABC 5071200
U s0 74606 C 50 159�Q11Vi-6993 BE APPROVED BY THE AGE PROJECT MANAGER
PD-9155 C P-7793 C + S015925 —-_-- -
Q C5065547pp-7799 'G.l_
A 100 5 7 _9030 C 759871 VT-8527 �r VT ON- ATTENTION: CALL 811 BEFORE YOU DIG
I VT-68 ABC OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED ,
vl SUMMIrKF YT_7 THINK BY THE OREGON UTILITY NOTIFICATION CENTER.
VT-45 ]VT-7279 { 5
P.4 7280 VT-7265 ---__- A 100 3795VT-7347 A BC THOSE RULES ARE SET FORTH IN OAR OBTAIN
COPIES
1
U 100]01 C 5015253 VT-6935VT 69 P SAFETY THROUGH 951.001.0090 YOU MAY OBTAIN COPIES OF
ABC D-8525 VT-7261 P PL-7521
ABC 500 112 4604 //yREA 4 VT-693 THE RULES BY CALLING THE OREGON UTILITY
d AT o 1 1 E B 50 152181/7-6906 A 100 3735 p 1D0 4 015 FIRST NOTIFICATION CENTER ADMINISTRATION @(502-232-1987)
5017500 �� Know y�ft be�
CZ 1-10D PD- i t I C TO REQUEST UTILITY LOCATES CALL THE OREGON
VT-726 -6 A 501723 .6983 A 75 483 Vi-6754 A 25 4411] .827 675
PD-7678 UTILITY NOTIFICATION CENTER,811 AT LEAST Call before you dig
-7283 PD-7916 5027878m VT 7267 ABC '. ABC { 2 1-11C VT 6945 PD-7674 PL-3014 2 BUSINESS DAYS PRIOR TO EXCAVATION
50 20659 6020662
63 < VT 6859 131 d 6 POE CONSTRUCTION DRAWING
�6 ABC 1121401pD-6985 1671546 d a 1 VERIFICATION 8 ESC VIOLATIONS C
PD-79.17 VT 7258 ® .n-m�� m.«„,m�N��w..<�acIELLATIO
8123 VT-7568B 50 1747 50 20656- PD-7615
TS 7719PD-8022 49 VT-6152
PL-1590 Foreman: Date:
B 5B 2 75 6602 I 25 45678
,p A General Foreman: Date:
B A 75 4934 PD-7677 PD-8 15 6501
A pp IVT-7569 B 50 179 VT-6710 VT-6795 't 50 65868 alum ordrequired forlleld construction changes PD-802 BSO 17194 B 501261 VT-6 11 50124% VT-6751 P PL-6262 l
7570 '9 VT.757� PD-B 0 B5014226VT-671 B 5014760VT-6750 d_PD 7676 SDPMENG REVIEW ASBUILTBYDESIGNER
P SQ
31 1350 23901 A A 50 14715 -6753 WA 50 20637 DATE S= AV No
P-4 P PL-10 B 60 23802 a A d 12/8/2017 1 in=60 ft 1070001 0000014628 M2430961
A 82548465 PD VT-9 VT-10 PD-12 VT•1 PD-5PL-19 TITLE
- -- ABC=ABC ---� A _ ABC_ 552962 ABC �ABCwABCABC�►ABC � C 5030169 �C C ABC_ PL-158 B PL- REPLACE B/O 30 PRIMARY
PO-26
D 954 342 B I U PD-9537 C 100 5710 t A t VT-16P1--21 CIRC 17 SIZE
PL-355 875964 m d G'C1005514 pD-9532 v KING CITY-SUMMERFIELD 17 x 22
1 00 A 11 p C2 1.148 C) m PD- LOCATION
VT-6 n RD.2 B 23389
m d
C2 1-15A PO 028779 PD-811 t PO 8097 B 2567892 E 15695 SW OLD ORCHARD PL,TIGARD,OR,97224
m PD-1 PD-9531 PD-95 CSO 70112 1llVi■75 31691�s
DESCRIPTION
5 29333 C 167 2357 75 9827 C U PQ-92 1 p-9270 C*C B PD•8465 REPLACE BIO 30 PRIMARY BETWEEN VT-6984 AND VT-6983
PL 2]BjPfj27. 30 PD-31 VT-70 p-538 PD 953 551 C 50 27207 B 50 24114 ' ( COUNTY SECTIONS WORK INTISHEET
43 S 8 75 925 PO-19 [5029205 [759945 r PO-80 3 1
-954 Im 6 50 2931 PD-15 C t00 5 pp_69 ¢ C d J 7561789 d WASHINGTON C2110D 1 OF 1
m PD-9272 ws.sowvar.t DESIGNBY PHONE DRAWNBY
150 300 600 Feet D-67 CT59843PO-953 PO-8466 TOM COX 503-867-0414 HEIDI BOOMER
_C 50 27171 PD-8096 B ur+e cR[w cearTele
-1 1005332 D-66 U U C C -BFB = PU-80 502310`IPGF N �BOEc M.IRD
0 POR-LAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED