Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (140)
1 Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND - Delete Line OO XXX-XX BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). % z E GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. O w °u MAXIMUM SPACING(TYP) CI i"yJ TIROF GAf BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. o � Add Line — — — SPRINKLER MODEL(TYP) = 1/2°PIPE SIZE J r.� �a_ oz HEAD SYMBOL(TYP) Approved =3/4"PIPE SIZE Add Tee Conditionally Approved [ ] —I— = 1"PIPE SIZE O a w a li ,; , Markup Legend SPRINKLER SYMBOL DEFINITION ft COLOR/LINETYPE LEGEND " Delete Line XXX XX BLUE LINES= FEED TO FIXTURES(BATH,SHOWER,ETC.). % F f 1 GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. MAXIMUM SPACING(TYP) BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. Add Line — — — — — SPRINKLER MODEL(TYP) ._� = 1/2"PIPE SIZE >`,-7.',a HEAD SYMBOL(TYP) L_,-,; u Add Tee =.I- =3/4"PIPE SIZE C a o = 1"PIPE SIZE a°w a U� = 1-1/4"PIPE SIZE w%°'.-,Y �O` Add Elbow 1,-; LL m O QM 'u-'w a W L Add Coupling ti�0 3 E N2¢W Add Head 'C3' 1.2 \-A13\ Q N F w 3 i 1:.,.i, Delete Head - - Move Head of FYLL� �F�s ,O- -0- ;cdr-:,- ¢�uz ro�0.`.Ss�c3 Note:All revisions must be reviewed by Uponor y N m o =i`z x o 0 Table F002-10 i3Q�i =m'�wa ¢ 000>s:z >fh zzr>_.`,w..'�;t.� Multipurpose Fire Safety Systems c c¢ , z The Uponor Residential Fire Safety System is a residential fire protections .6-,,=4,—,,,L,?,,,,,.„--6▪..2,-2..-- system installed in combination with the cold side of the domestic potable W o o m¢>2¢o o z -z water system. Only licensed contractors trained by Uponor can install this system. z oa'.<.FNa�¢zp� -N.,-,,,,..2.,.,-g,` ,7,?-.. .2.^ 64 What to do if Changes are Required z z- .- U • n.� If any features or obstructions require the addition or deletion of sprinkler ftl v o a>o Ei v s>u heads,or significant relocation of sprinkler heads,contact the Uponor Design G x w o z'u Z r z>z= Department to determine if observed changes require a redesign ¢W (888.594.7726). x x y o L x, o0 000¢ - } ?_. —1 N z z c '�L V 'J f F� Com. --. e/ - d _i z< ¢o❑ zo * �, 7 �.} �za<¢o� o oma, ` f L u _ -. -_ 02.E=0.6_7. >9 t ��� � I� PIED; oXNac Is, 1I' r p �,f%t"' RF Fr - �'<',3',c,,,,,a oz a _ .CSG > wzr o oc.d= - - yxoz¢o 4 wo. i m i ,� t ' o CES 18 I 1 T :1 8: •r RC-RES-16 hI To �. z_ LTE - I here b certifythat this plan,specification, r- Y I _ V LCC.,4�- T orreport was re - •"" direct supervision and that I am NICET I - F .di;� SII `I � � Ip prepared by me or under my III "' w Certified at Level[V. I �� 1 1 � Tandem 2-Car - _ �- V f,�� II' 5.1 MAIN SHUTOFF - J :., Garage - a �` / r V VALVE LOCATION i Brent D Kotula �- F r 4E - r � \ 1'/"A uaPEX TO . Date: Reg.No.113889 I— CONNECTIONS FROM SECOND 4; ` �:. \ \ Li i / -�6 \ SYSTEM /Ml ur d FLOOR TO THIRD FLOOR V :::-I__...7. t --• / / / Kfiec11. 1�_ j / - �c Et II . .� 2 f / :tet �w� ,� fi� r1 r - 2 r \ 1' PERI �r _ kRC-RE.S- _ Ef - Jv _ si� ONQUA NFROM IR I ( Fes_N y �- C ETO SEC FIRST °1 r1 - ( r 2 �.' / .�� ,', In, \ FLOOR TO SECOND FLOOR \ �I��� i I r F t w �, f� 1 � ,�-y ''RC-RES-164' ', a , n. r moo; <I - ��, wo " � y' 1 6 _r F{�CJT6 N,.� � RI� -,-_±..., / �,SH am�p1 III RC RFS- 6., 'F _ - '—' ',-1- I ; \ 1`- -L , r r ■ w a°vM�i�.�, . W N m w r J k :`f! N 7 ,'L . �.: I �� -. �, * l i r!- k z u W a vOi o m` .AL( A I ,,.Ir i LII •��.� - W a Q a z '2. � I5 (III 6 M g z a H w u ___J N z o " it 9=� LU o �. 1 -may I I1 ' E s - u r. ' _ • f RGA,.16� V� -, RC RC-RES-01i ES11 r; �� --i,:- , y / . 4_ r ! _,.„,i • IV r 1-. 1 �/ Z H,, 6 '---5,--t,-, ri-,-F . ,I . -�J `�• 1 _ .III . l� L� ?a ,0 Pi _ _ l •, JI �.�/• ..Fz m 1 I� �'� �* I / , _ _ F R ev,E W Y ce dam O' H ?fQzf�ii o m I PER 1 �. 1 '\, L el � LL TT • z o _-. zwFs L 3 THIRD FLOOR z SECOND FLOOR 1 FIRST G3u� FLOOR do���a = SHEET DESCRIPTION ft F101 1/4” = 1 '-o" F101, i/^11 = 1 '-On F101 1/^n = 1 1_On ALL LEVELS MIRROR 1 1 `t1 1 `t1 19 SHEET NUMBER s 0s 15 -,_....-.__—___ F101s 1/4"=1,-0" © UPONOR CONFIDENTIAL A�uaSAFETI" GENERAL NOTES' ProPEX LF Brass In areas subject to freezing,care should be taken in unheated attic spaces See General Notes 8.2.5.7 for Architectural Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations ass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements mvry 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor '^ 3.3.11.3. Blocking Maybe Fire Sprinkler Adapter Document'Uponor AquaSAFE Attic Insulation Guidlines"for attic f Required.If -� , - _- Push-on Nut installation guidelines(Provided in Contractors Documents package or online ` / O SECTION2. COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Blocking is Used, 11/"Min. i i wwwguidelines atw THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND Use The 2 Tap "�~ 4 j^O UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. Screw Hales �^LL1 Bottom f mounting Extreme Temperature Installations Planter Box Window,Bay Window or Similar Feature. a f Bracket to Face of Truss If no additinal floor area is created No Additional S q ni 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE AquaSAFE Residential Fire Safety systems are often installed in attics or Sprinkler is Required. n C RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Fire Sprinkler Adapter - other areas exposed to temperature extremes of heat and/or cold. Follow ¢N'Et''''-.' Ji Mounting Bracket 8'-0"or less u m PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE the recommended extreme weather installation instructions to isolate and / o SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE ,f�� , protect system components from extreme temperatures. Because this RC-RES-16 Fit'u w o SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#10 x 1 1/2" 'tY 5� system also delivers domestic cold water directly to plumbing fixtures, 9'-0"or less ® \ CL u m v?0 Full Course Uponor highly recommends that you protect the tubing with adequate / j°;ry z 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH I I ILI ^u Thread Screws If insulation in warm weather areas to minimize heating of the cold water Z m�,p ft NFPA 13D 2016 EDITION. In Bottom Holes supply. 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE'SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. \ �_ v\ o .l.m m C Installation methods include,but are not limited to: ^' W N Q m 6 MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-Fre Flat-/ Tenting over the fire sprinkler piping. ` ' o\ i/ m\ O'0 m w DAMAGED MUST BE REPLACED. Concealed Sen1u \ ` r" ' )_ • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 ft,be more than 2'-0" Concealed Flat • Increased de Sprinkler Head Cover Plate • depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the o 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. sprinkler.No Additional Sprinkler is Required. Caution: If you will be installing spray foam insulation,make sure to o^ z<a o z Y f x r . .t.,2-,- 8. Dort OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction Protect all components during application.Consult with the spray foam i manufacturer to ensure compatibility p pP u s x o o L- p y with all products before application. NFPA 13D Table Heat Sou 3 Distances From v z ft o _ft ft°o y 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE F...7',<,-,-,n,-,2E'd r<z><�,o co L o z WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Sources PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR Consultation with local building officials is encouraged to ensure compliance o=o�`_c o m x ProPEX LF Brass Fire with local building codes. F�� sF x c?.�o AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler Adapter Tee Fire Sprinkler Adapter Ordinary Intermediate z°s 5 c z o 3 s FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM Heat Source o ft z_d s 'l �y�Push-an Nut Temp. Temp. z v s w F? WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE 135°-170° 175°-225° i m�""�=z z THIS SIGN". `' Bending PEX Tubing Side of Fireplace 36" 12" o c o o z z o o C s 5ql] 5 / 1% Min. The minimum bend radius of Uponor PEX tubing in any direction is six times -' 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEX"UNLESS NOTED. 1%'Max. the outside diameter(6 x OD). Front of Fireplace 60" 36" W m o m- a 5 z 3<x 4z of Fire Sphn der Adapter -/ Bottom cf Mounting Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX Wood Burning Stove 42" 12" z- w,.<°.n o 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket Bracket to race of Truss f,y d_ g tubing to facilitate 90-degree rigid bends. Kitchen Range 18" 9" Q<i u o oz_z z x. S 33 c 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 0BJ ® Wall Oven 18" 9" V z z G G<5 a_,w'm a .7 F BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE 2-#10 z 1 1/2" Recommended Tubing Length Between Fittings Hot Air Flues 18" 9" UJ z:,;',.:=5„.?, -.6.55,,,, < S RESTRICTIVE SPACING LIMITATIONS. Full Course f"f m<5,,s,_.6- a o u-5 Thread Screws i 1- i } Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9" O z u o z F c<,g E z a, - InTopHales �� rzy� 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING 3/8"ProPEX Fitting Uninsulated Hot Water Pipes 12" 6" .w=ft-x 5 o 2" p x�� zc Nd°o-�m" MOUNTED OBSTRUCTIONS. -� Side of Hot Air Diffuser 24" 12" s z 3 o u o N \ 1/2"ProPEX Fitting 2 1/2" 3 d 1 d x o 6,ft o'0 5 0 Front of Hot Air Diffuser 36" 18" 3o o5Pi`ft oc�ymy PLUMBING14. THE TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE 3/4"ProPEX Fitting Hot Water Heater <z a<'u o x 0 w SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Lead-Free-Rat-<� q 3 o c z o p c Concealed Senlu \ Concealed Flat 1"ProPEX Fitting 4 1/2" Furnace 6" 3" >y o E Y u N F o 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN Sprinkler Head Cover Plate 1 1/4"ProPEX Fitting 5 1/2" SOW-250W Light Fixture 6" 3" _O o o m z z z 0 m ft CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS ¢z z<o U s o o N m THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. 250W-499W Light Fixture 12" 6" x F 3�,O w^,u z z<<, us oog- 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Exposed Installation Requirements. .,'. ¢ z o n w • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor AquaPEX''tubing(white)and Pro EP Fittings and ProPEX'"' \ I ^Y a THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT'PER SPRINKLER. Brass Fittings are approved for exposed installastalla tion where the following • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood]Dist Ceiling Assemblies. 71 co a[., ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood Hoist or open ry I I here by certify that this plan,specification, (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. ry SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). �I m or report was prepared by me or under my (a)THE FLOOR AREA SHALL NOT EXCEED 18 Fr(1.7 M') 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. direct supervision and that I am NICET Oil Certified at Level IV. (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ I THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 'I ALONG THE FINISHED FLOOR. 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center 'I 1.55" / 1.66' 'I are used. (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6Brent D Kotula PLANE OF THE PRIMARY WALL. temperature rating of 155°F(68oC).. Listed residential automatic sprinklers of maximum activation 1" 3n 2 -4 Hanger 1�� Hanger Date: Reg.No.113889 (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Support.Metal Tubing ppo . Tubing Support Spacing: (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE (Anchor AquaPEX Tubing Securely Enough to Support the Tubing,Yet Relaxed ARCHITECTURAL FEATURE. 1. Metal tubing supports designed for plastic tubing shall be used. Enough to Allow the Tubingto Expand and Contract) 2. Do not use supports that will damage the tubing.Inspect metal p '' 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. supports for sharp edges. 1. Along Horizontal Runs,Install Supports °� • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 3. Do not rigidly anchor Uponor AquaPEX"tubing with supports.Allow Every 32",if Horizontal Runs are enough tubing for freedom of movement to expand and contract. Continuously Supported,Place Tubing Supports at Six-Foot Intervals. THROUGH 8.3.8. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each F-- :1,-,, • • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FTz(5.1 Mz)AND LESS Floor and at a Mid-story Guide. • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT z MEET ALL OF THE FOLLOWING CONDITIONS: THE AREA OF E z THE SPACE DOES NOT EXCEED 24 FT'(2.2 M°). In-line Flow Test ft f o (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE The In-line Flow Test can be constructed on site. It performs a flow test to � a a ro MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. High Upstream Pressure ensure proper system operation and flow(see Figure F001-8). o m mv • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND If the upstream pressure exceeds 80 psi a pressure reducing valve may z w SIMILAR STRUCTURES need to be installed. Some jurisdictions may require a pressure reducing ^o .. • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE valve regardless of upstream a m"�o ry v 9 p pressure. Uponor AquaPEX < o o EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND Tubing j '1 ' ,� CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, / •.•.r '" 5 CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PRPOSES. W 5 ? m w • 8 3.5 1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR a z 8.3.5.1.2. O F • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING f- w UNITNO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. j j I^ a a Q F w ee • 8.3.5'.1.2 WHERE FUEL FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE V I <z J o w DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE m Male Threaded Coupling ProPEX Fire CT] <a O a o INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED Sprinkler Adapter EQUIPMENT FROM THE OCCUPIED SPACE. 0 `,°y • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT , To Hot Water Heater Male Threaded Coupling `0"Ball Valve o, ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. 1' 1 • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING _ Female Threaded W CONDITIONS: z (i)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED Tee with Water T"-I Ce 3 J 100 FP(2.83 Ma). - Pressure GaugeE. Pressure Gauge Sprinkler Orifice ) O m m r- or Iv (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS .. u u (Optional 6. AT THE LOWER CEILING ELEVATION. /'� o 5 a E y 1..` I Q �uF>55 (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE Main Fire Sprinkler Flow Test LLJY TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. Shut-off Valve �/ fO~z w - To ensure the system provides enough water for proper fire sprinkler L.L o a m to-�+ (4)SKYLIGHTS NOT EXCEEDING 32 FTz(2.97 Mz)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. performance,you should conduct a flow verification test. o D1 • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS ` Uponor Warning Signs ' F (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR _ p Note: The NFPA 13D Installation Standard does not require flow 1 I Z (r'I £Y m Q ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED verification. i-i m a s LL p PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. 1'••i 3 cu cu S c a _ Pressure Reducing Before performing ae flow verification test,confirm the water pressures by 2 • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING Valve EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. contacting the Water and Sewer Department of your local city. Ensure the x w W d o F 18. INSULATION GUIDE LINES PER NFPA 13D. - available water pressure matches the pressure used in the system design. d u u�,m z `w 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40oF. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE - Note: The sprinkler plan indicates the most hydraulically remote sprinkler SHEET DESCRIPTION USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY ,. ji (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS ee INSULATED TO MAINTAIN 40°F. a your local code. •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO ,` COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE Note: It is a good idea to notify the fire inspector at least 24 hours prior to GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) performing a flow verification test. This may speed up the inspection SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. process and eliminate the need to repeat the test for the inspector. SHEET NUMBER CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE v PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED. Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in Contractors Documents package or online at www.Uponorpro.com)for more information on Flow Test Setup,Assembly,Performing the Test and L Troubleshooting. If there are any questions please contact Uponor. F BPs' © UPONOR CONFIDENTIAL FO 0 1 I- PRV Set Pressure