Plans
SCOPE OF WORK FIRE EQUIPMENT SYMBOL LIST 4. #,4 -LEASE PHOVIOE o o MODIFY AN EXISTING ADDRESSABLE CENTRAL STATION FIRE ALARM SYSTEM SYMBOL DESCRIPTION PART ROUGH—IN / NOTE MOUNTING HEIGHT m 0o WHICH INCLUDES THE ADDITION OF DUCT DETECTOR MONITORING, MPLETED NFPA 72 s HORN/STROBES, AND STROBES. RECORD OF FIRE ALARM CONTROL PANEL NFW2-100 NOTIFIREV 3 EXISTINGEXISTING EXISTING 3 ®OMPLETION AT s Y ADDRESSABLE MINI MONITOR MODULE NOTIFIER MOUNTS INSIDE 1-GANG MOUNTS INSIDE 1-GANG 15 "NAL INSPECTION NMM-100P I DUCT SMOKE DETECTOR 2 BY OTHERS MONITORED BY NMM-100P Nzz HORN/STROBE - WHITE " 80" MIN TO LENS BOTTOM AFF AFF SYSTEM SENSOR 4 SQUARE, 4" OCT, SINGLE OR gg' MAX TO TOP OF LENS AFF g GENERAL NOTES (NAC AND CANDELA NOTED AT DEVICE) P2WL DOUBLE GANG BACK BOX 6" MIN TOP OF LENS TO CEILING i %g 1. THE FIREQ SYSTEM SENSOR 4 RE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA STROBE — WHITE 80" MIN TO LENS BOTTOM AFF 111%172 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. " SQUARE, 4" OCT, SINGLE OR 96" MAX TO TOP OF LENS AFF Q (NAC AND CANDELA NOTED AT DEVICE) SWL DOUBLE GANG BACK BOX 6" MIN TOP OF LENS TO CEILING 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE 1 41111%Rig THAN ONE FLOOR SHALL BE RISER RATED. C13 CEILING MOUNT STROBE - WHITE 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. STSIrM SENSOR 4" SQUARE, 4" OCT, OR DOUBLE CEILING MOUNT 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. (NAC AND CANDELA NOTED AT DEVICE) SCWL GANG BACK BOX 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND LIGHTNING PROTECTION DEVICES. 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLY PROTECTED. 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS CITY OF TIGARD ;nD "FIRE ALARM CIRCUIT". CrTY Z 11 tliliJ 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.3 PUBLIC MODE REVIEWED FOR CODE COMPLIANCE IVED (NEPA 72). 9. CENTRAL OHE TATION PROJECT IN MONITORING ACCORD NCE WITH SECTION 26.6.3 (NFPA 72).UPON Approved: I • ryry 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTORD �i� OTC: I I AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH � F TI AI D SECTION 14.6.2.4 (NFPA 72). TIG Permit#: FP. a -, coon)) BUILDING DIVISION 0, Address: )41/5 --7o-11 A \/ Suite#: ,) ( -4# ' ,..00 (3) By: 0 B Date: R-)V 0 FIRE ALARM OPERATIONAL MATRIX (1 2 NO CHANGES I— W SITE I- ON co rt 2W SW DARTMOUTH STREET - - - _� vJ c I •;jL� 4117"" '"'7111110: IS j ryi■� 4 BUILDING A 1i; I ilfi e n iry nj C.) W i NI t 1 J U o Tx �"�� 1 .�_I 1.____r? ' W v • I 00 wo co L•61 Q _ w1 7 / ' / N� II I r � "2 V v-CNI— LL i � �� i� %/- 7a r X��IL�'li. LU 1 %. �, • kiA,� AREA OF WORK REVIEWED/APPROVED o: '/UILDING C�j �� .� 1 i I I i i//% /"/:/�,,� �'' '' 1 im BEN BREIT-4460LEA I DWG REV./DATE +`I I 0 02/14/18 tal `'��CT�,I V II I E BUILDING C - FLOOR 2 DRAWN BY: I ITME - - - - ,� 1 ''r I CHECKED BY: BJB I - - ELMHURST ST. DEDICATION A R E A 0 F WORK FIFA.dwg r1 Yi_kMilir NOT TO SCALE DRAWING#: FA-1 ORIG.SHEET SIZE:11•x 17 #OF DWGS IN SET: SHEET1OF5 808 BATTERY CALCULATIONS NOTIFICATION CIRCUIT SCHEDULE #,, NOTIFIER NFW2-100 REV 3 C ) VOLTAGE DROP CALCULATIONS ELEC RM COW1,8 PART # DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL CIRCUIT TOTAL WIRE WIRE VOLT VOLT ACCEPTED VOLT CKT / DEVICE LOCATION / AREA ORIGIN AMPS DIST SIZE DROP AT EOL DROP DROP % w NFW2-100 MAIN CIRCUIT BOARD 1 0.1450 0.1450 0.2750 0.2750 E N-ANN-80 REMOTE ANNUNCIATOR 1 0.0150 0.0150 0.0400 0.0400 N-1 HORN/STROBE FLR1- HALL 108, LOBBY 100 FACP 0.217 130 14 0.17 20.23 YES 0.85% NOT-BG12LX PULL STATION ADDR 1 0.0004 0.0004 0.0005 0.0005 N-2 HORN/STROBE AND STROBES FLR2- LOBBY 200, ADVANCED ENDO, GABEL FACP 0.850 545 14 2.84 17.56 YES 13.94% NP-100 PHOTOELECT ADDR HEAD 5 0.0003 0.0015 0.0065 0.03 N-3 HORN/STROBES AND STROBES FLR2 - GABEL CENTER FACP 1.107 645 14 4.38 16.02 YES 21.49% NH-100 HEAT DETECTOR HEAD 2 0.0003 0.0006 0.0065 0.0130 N-4 HORN/STROBES AND STROBES SPARE FACP 0.000_ 0 14 0.00 20.40 YES 0.00% IP NMM-100P MINI MONITOR MODULE 6 0.0004 0.0024 0.0050 0.0300 ""'END-OF-UNE METHOD OF CALCULATION NC-100R RELAY MODULE 4 0.0003 0.0012 0.0065 0.0260 " 8 GB6-24 6" WATERFLOW BELL 1 0.0000 0.0000 0.1000 0.1000 1 PC2WL HORN STROBE - 15 CD 1 0.0000 0.0000 0.0710 0.0710 1 lt111 P2WL HORN/STROBE - 15 CD 12 0.0000 0.0000 0.0540 0.6480 a P2WL HORN/STROBE - 30 CD 2 0.0000 0.0000 0.0740 0.1480 P2WL HORN/STROBE - 75 CD 1 0.0000 0.0000 0.1210 0.1210 SWL STROBE - 15 CD 16 0.0000 0.0000 0.0430 0.6880 SWL STROBE - 30 CD 2 0.0000 0.0000 0.0630 0.1260 SCWL CEIUNG STROBE - 15 CD 1 0.0000 0.0000 0.0410 0.0410 PC2RL HORN/STROBE - 15 CD 1 0.0000 0.0000 0.0410 0.0410 PC2RL HORN/STROBE - 150 CD 1 0.0000 0.0000 0.2170 0.2170 STANDBY TOTAL 0.1661 ALARM TOTAL 2.6180 'CALCULATIONS BASED ON 24 HR STANDBY TIME do 5 MIN ALARM TIME* AMPS (A) X TIME (H) = AMP-HRS (AH) 20% DEBATE STANDBY 0.1661 X 24 = 3.9864 - ALARM 2.6180 X 0.0833 = 0.2182 - TOTAL AH = 4.2046 5.0455 BATTERIES TO BE INSTALLED: 7.0 AH M N N 0) 0_ 0 C CC ~ W -limm O U N r^ W 3 > >- H o v V) Z mL' 2 W wce C) t-u- a < J w � J W Y - a xirV o -- 0 LTJ re tL DWG REV./DATE 0 02/14/18 DRAWN BY: TME CHECKED BY: BJB FILE NAME: FA.dwg DRAWING#: FA-2 ORIG.SHEET SIZE:11"x it #OF DWGS IN SET: SHEET 2 OF 5 • • DETECTOR SCHEDULE MODULE SCHEDULE FIRE ALARM RISER DIAGRAM (TYPICAL) 4f,",,!.. ADDRESS DEVICE LOCATION AREA ADDRESS DEVICE LOCATION / AREA m oesi 81 D-1 PHOTO FLR1, ELECTRICAL ROOM 106 - AT FACP M-1 SPARE SPARE w D-2 SPARE SPARE M-2 MONITOR FLR1, ELECTRICAL ROOM - COMM TROUBLE D-3 SPARE SPARE M-3 FLOW FLR1, MECH/SPRKLR RM 105 - WET FLOW AT RISER 5 W D-4 SPARE SPARE _ M-4 TAMPER FLR1, MECH/SPRKLR RM 105 - WET TAMPER AT RISER © Q 0 M. 4Mr IL, 4] g D-5 SPARE SPARE M-5 TAMPER FLR1, IN VAULT - DBL CHK VALVE __ . D-6 SPARE SPARE M-6 SPARE SPARE ) D-7 SPARE SPARE ( © © BY OTHERS �g M-7 SPARE SPARE TYPICAL PWR '_— F. D-8 SPARE SPARE M-8 PULL FLR1, LOBBY 100 - PULL AT MAIN ENTRY SLC TO FACP D-9 PHOTO FLR1, AT ELEVATOR LOBBY M-9 SPARE SPARE 18/2C FPLR-\ CI 414.D-10 PHOTO FLR1, AT ELEVATOR CONTROLS M-10 SPARE SPARE I D-11 HEAT F1R1, AT ELEVATOR CONTROLS M-11 SPARE SPARE 1� D-12 SPARE SPARE M-12 RELAY FIR 1, ELEVATOR RECALL TO MAIN 11 D-13 SPARE SPARE M-13 RELAY FIR 1, ELEVATOR RECALL TO ALT1 lit 11111 D-14 SPARE SPARE _ M-14 RELAY FIR 1, ELEVATOR HAT FLASH rELECTRIC ROOM 106 D-15 SPARE SPARE M-15 RELAY FLR 1, ELEVATOR SHUNT TRIP ` I I I AUX 24VDC I 08 D-16 SPARE SPARE M-16 MONITOR FLR 1, ELEVATOR SHUNT VOLTAGE 1 2 EOL 4.7k0 (1ST FLOOR) D-17 SPARE SPARE M-17 SPARE SPARE r • I SLC I V e D-18 SPARE SPARE M-18 SPARE SPARE � �I NFW2-100NOTIFIER 2 0 0 j EOL_4e.7k0(LOBBY, ENDO, GABEL) D-19 SPARE SPARE M-19 SPARE SPARE Il -I-- REV 3 3 ISI ► I EOL 4.7k0(LABEL) D-20 SPARE SPARE M-20 SPARE SPAREVS _ FACP I �e D-21 PHOTO FLR2, AT ELEVATOR LOBBY _ M-21 SPARE SPARE / i WnDAC 4 1 SPARE EOL T _'LAO D-22 PHOTO FLR2, AT TOP OF ELEVATOR SHAFT M-22 SPARE SPARE D-23 HEAT FLR2, AT TOP OF ELEVATOR SHAFT _ M-23 SPARE SPARE I 120VAC DEDICATED) I D-24 SPARE SPARE M-24 MONITOR FIR 2, DUCT DETECTOR (ADVANCED ENDO) L_ J D-25 SPARE SPARE M-25 MONITOR FIR 2, DUCT DETECTOR (VERIFY LOCATION ON AS-BUILT) D-26 SPARE SPARE M-26 SPARE SPARE ***SPARE CONTINUES*** SPARE CONTINUES*** TO/FROM FACP D-99 SPARE I SPARE M-99 I SPARE (SPARE �18/4C FLR 1 LOBBY 100 i1 N I I NOT1F1ER I O L I N-ANN-80 I 0 L FAA I I \-. J 1 W SLC FAC8/2CFPLRP p U N ( ) IX 0 W W Cl)r 1 r ELEVATOR EQUIPMENT CLOSET 1 lese 0 vJ TOP OF SHAFT ' CO W C r `-P `i / m,RECALL TO MAIN TO W , Z G OTHER LOBBIES(� , ,RECALL TO ALT ELEVATOR W W "`PPP ox,HAT FLASH GUTTER w CONTROLS Z Q < MAIN LOBBY m,SHUNT TRIP J W H J CABINET V O SHUNT VOLTAGE PAM SHUNT TRIP W Y l ' JB 0 G. 0 m< x ti ELEVATOR PIT LU rI 0 ,- 18/20 FPLR L J L ,J V ce : IL DWG REV./DATE * INSTALLED IF NEEDED 0 02/14/18 NOTE: WIRE TO BE FPL, FPLR OR FPLP PER NEC DRAWN BY: TME CHECKED BY: BJB FILE NAME: FA.dwg DRAWING#: FA-3 ORIG.SHEET SIZE:Nk it #OF DWGS IN SET: SHEET 3 OF 5 - -- I ops © VERIFY LOCATION • A OM-25 O O 10 9 cc j �I'" 4,- [Ti_±Ilt_IL -I k^- 1s'I L L. i ,1 r-Com.: : :— ry O Ad I j III I I �z 1_)____11:.\,, LI i lb_� 1 i __, III � CONSULT. :., I I CONSULT 2 __ . I _ '' ( � j,; 210 +: 211 --,1 1-_\1__ !.1__; ' t\_. - - - - - - -- 1____I 074. __ r e _ , I Wc_____AITING -, SAS FS i __ _ L_ � 0 (__203 - '_____, ,.F_i,_ x a 209 I N-3.4 J N-3.2 OFF. MGR. g R.i 14h_ I� ' /. — — G 1 o I 15�CiD 212-- r i . _._.u___ l u�C�iII I ' 9 HALL -__ /1r!�''/'�I N-3.5 -3.1 � I' ' "rzipAI / i15CD 20$ 15CD I-� , 1;\, 5,i Ad/Or , Ar0,1 -- Li________ :,,,r 10 / N-3.3pRt 14 J ;_� I J5CD f���J =a FROM FACPI� ' _ ° I PhIS71�O/ L` j ON FLR 1t4 - __-�zdi��/�N• � �Ir , ° ,-3.7 �_ � MKTG. ; _ _�' � � �' � L 207 1 SMALL PR CEDURE 1 I0, 1!15CD RECEPTION - - i �� --PROCEDURE HALL I „yr l=_: i I, I J 204 r � ! _.'1=- -;- - r 213 'iI � IISEC �- , -- I i I - I DR. OFFICE I` ��— HALL } I r-11 - - H Iy ! .1 -J I i' I N-3.20 1( =J PSI. i ' i , ' \, EOL 1I- I� �, 15CD N .__— _4,7,- — ! 1- r ,, _ I -226.- _ I �f I I �����. i. I } 1 sco 1 I rn CC FROM fACP r C 1....7_,____, 0' 0 V 41 ON FLR 1 -Ni, �- I HALL ;i i i HALL I S AII� HALL -- I N-3.16 -- 1 238 41. L - L 223 J I 15cD 222 -1 ' S-3 - _. �f ` _- - _____ _ mss, ---- Ci 2 N-2.2 el ISTORAGE ! °I -�! - -� jr-CrilNum34 I r__232 ---FA--7-1 cD N 15 19 ! _ U N HALL --- I ' 4-,==;:-4,-,r- IRTY 5cD : I I Ce 1 _ 240 236 - r----- 28 !'1!,--;_5 rr,) i (�NISE ; • 11-/ L-Hill'—i----i� Z Or_. N-3.13 +! 18_,. j I I �// j I -HALL '-- ,, ; ,---=-2-35 / r HALL 15CD ° i 1 STERILE i /7-) 219 r + Z m n2�/ N-3.9 229 / 227 I r/ I STOR. - I —1I W w W � 15CD - i \ L 22 W Q I j -1j N-3.10 'MI 3.IrT_J I -1 Cs11 c U C 15CD 15C -fi:. 15C[� I �.. '_ i I 1i I 1 -� W j HAIR WASH I CD CCI 00° W 233 I; _� LARGE PROCEDURE � I ��I = Q to (� TjI I) j r_ 2251 't - i i STAFF ♦^ N II J -/ ,� V LL < <,-�, `, .t-�� i 221 - DWG REV./DATE ! -- l 1 ! -; 0 02/14/18 ,, TREATMT 1-- ., TRTH CD_` 30cD - r ,, I _ — "r 11 II- 1 i - ° __Ir O DRAWN BY: TME CHECKED BY: ' BJB FILE NAME: F L 0 0 R 2 ° ' 8'_ 416' FA.dwg —.-_. --- --- --_ -J 7,,_____,1k0 .�� '\ DRAWING#: �__ SCALE: 1/8"=1'-0" FA-4 ORIG.SHEET SIZE:11"x 17" if OF DWGS IN SET: SHEET 4 OF 5 828 P.4¢n a .1O" ° " " 10 517,1 U, .11 g it `` I g 111 . _ FROM FACP SLC - SLC TO NEXT DEVICE "7„--4.001111, OR SLC IN SLC OUT OR • • PREVIOUS DEVICE (TYPICAL 18/20) (TYPICAL 18/2C) TO FACP FOR SLC + •SLC + OPTIONAL CLASS A 0 � � 0 C ( ) MONITOR MODULE _ si Orr�i-� ,-. 46 -\ OEO 5g -� FROM NAC SOURCE ISI �1 2�i�1 1-1 2�i�\ OR 1"'% ; ® TO NEXT DEVICE 3\-� f (\■ /) PREVIOUS DEVICE u■n - .I um I-� EOL(4.71(0) 10 7p NAC - NAC _ TENS LOOP ONES NAC IN NAC NAC OUT • • • • N 1.voC) (—) (+) (+) (—) CNI NAC + t\ NAC + (3) y YELLOW VIOLET RED BLACK ix 0 _ ‘1111[ 411, ( TYPICAL 18/20 ` TYPICAL 18I2C / r Q O IP C , _ O EOL_ H 1 � 1 11.m_6,7--, Iv�J Iii O Lu er pO �� • 47K A e o I- -1 l 1 U (V CAUTION: - 0 W V) DO NOT LOOP WIRE UNDER DUCT DETECTOR re 0Z TERMINAL 1. SYSTEM SENSOR (BY OTHERS) W BREAK WIRE RUN TO PROVIDE UNIVERSAL MOUNTING PLATE I SUPERVISION OF CONNECTIONS. SW,P2W,SCW,PC2W s s m © S S S m Z m i L-SERIES: ctiErt SWL,P2WL, A o O e O n O W Z SCWL,PC2WL ALARM TROUBLE SUPERVISORY H Q SYSTEM SENSOR J W 0 NOTIFICATION DETECTOR MONITOR MW Q SCALE: NTS ODUCT SCALE: NTS W O (n NW w Ce VW re � u_ DWG REV./DATE 0 02/14/18 DRAWN BY: TME CHECKED BY: BJB FILE NAME: FA.dwg DRAWING#: FA-5 ORIG.SHEET SZE:11"x 17' #OF DWGS IN SET: SHEET 5 OF 5