Loading...
Report )4G( 1/1V - .2-1.-/Ls 5 RE PAUL .1. FORD - i-4 EI RECVIA) COMPANY wo -2nic SEP 0 5 2(317 OF 1' Date: August 22,2017 ' , y Katie Stana U � DIVISION Crown Castle Paul J Ford and Company 2055 S. an Drive 250 E. Broad Street Suite 600 Chandler,AZ 85286 Columbus,OH 43215 602.845.1747 jsmlth,:pjfweb.com 614.221.6679 Subject: Structural Analysis Report Carrier Designation: Verizon Wireless Co-Locate Carrier Site Number: NA Carrier Site Name: POR Villa Ridge l Crown Castle Designation:g Crown Castle BU Number: 874135 Crown Castle Site Name: West Portland Crown Castle JDE Job Number: 443800 Crown Castle Work Order Number: 1432933 Crown Castle Application Number: 394796 Rev.0 Engineering Firm Designation: Paul J Ford and Company Project Number: 37517-2566.001.7805 Site Data: 10955 SW 65TH AVE,TIGARD,Washington County,OR Latitude 46.26'29,4';Longitude-122°44'38,3" 94 Foot-Monopole Tower Dear Katie Starts, Paul J Ford and Company Is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural'Statement of Work'and the terms of Crown Castle Purchase Order Number 1060852,in accordance with application 394796,revision 0. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation,under the following load case,to be: LC7:Existing+Reserved+Proposed Equipment Note:see Table I and Table II for the proposed and existing/reserved loading,respectively. Sufficient Capacity - Thls analysis has been performed In accordance with the 2014 Oregon Structural Specialty Code based upon an ultimate 3-second gust wind speed of 120 mph converted to a nominal 3-second gust wind speed of 93 mph per section 1609.3.1 as required for use in the ANSIRIA 222-G-2005 Standard,"Structural Antenna Supporting Structures and Antennas",with ANSIRtA-222-G-1-2007 and ANSIRIA 2t22--G 2 2009 Addenda per Exception#5 of Section 1609.1.1. Risk Category II,Exposure Category C,and Topographic Category 1 with a crest height of 0 feet were used in this analysis. We at Paul J Ford and Company appreciate the opportunity of providing our continuing professional services to you and-Crown Castle. If you have any questions or need further assistance on'this or any other projects please give us a call. Respectfully submi ed by: g,��uCTUR,�4 ' - a �, - �@ PROF�9 0 � 89567P Tr Jared Smith, E.I. Structural Design/> -- GON* tnxTower Report-version 7.0.5.1 ��18'%t d' �w K.KEaµ° e:tfP IG 2 2 2011 PAUL J. FORD �•Z:? & COMPANYZo,5 Date: August 22,2017 Katie Stana Crown Castle Paul J Ford and Company 2055 S. Stearman Drive 250 E. Broad Street Suite 600 Chandler,AZ 85286 Columbus, OH 43215 602.845.1747 jsmith eb.com 614.221.6679 Subject: Structural Analysis Report Carrier Designation: Verizon Wireless Co-Locate Carrier Site Number: NA Carrier Site Name: POR Villa Ridge Crown Castle Designation: Crown Castle BU Number: Crown Castle Site Name: W Crown Castle JDE Job Number: Wesstt Portland 443 Crown Castle Work Order Number: 90 1432933 Crown Castle Application Number: 394796 Rev. 0 Engineering Firm Designation: Paul J Ford and Company Project Number: 37517-2565.001.7805 Site Data: 10955 SW 65TH AVE,TIGARD,Washington County,OR Latitude 45°26'29.4'; Longitude-122°44'38.3" 94 Foot-Monopole Tower Dear Katie Stana, Paul J Ford and Company is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural 'Statement of Work' and the terms of Crown Castle Purchase Order Number 1060852, in accordance with application 394796, revision 0. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC7: Existing + Reserved+ Proposed Equipment Note:See Table I and Table II for the proposed and existing/reserved loading,respectively. Sufficient Capacity This analysis has been performed in accordance with the 2014 Oregon Structural Specialty Code based upon an ultimate 3-second gust wind speed of 120 mph converted to a nominal 3-second gust wind speed of 93 mph per section 1609.3.1 as required for use in the ANSI/TIA-222-G-2005 Standard, "Structural Standard for Antenna Supporting Structures and Antennas", with ANSI/TIA-222-G-1-2007 and ANSI/TIA-222-G-2-2009 Addenda per Exception#5 of Section 1609.1.1. Risk Category II, Exposure Category C, and Topographic Category 1 with a crest height of 0 feet were used in this analysis. We at Paul J Ford and Company appreciate the opportunity of providing our continuing professional you and Crown Castle. If you have any questions or need further assistance on this or anyother projec sces to please give us a call. Respectfully submitted by: Jared Smith, E.I. Structural Designer tnxTower Report-version 7.0.5.1 94 Ft Monopole Tower Structural Analysis August 22, 2017 Project Number 37517-2565.001.7805,Application 394796,Revision 0 CCI BU No 874135 Page 2 TABLE OF CONTENTS 1)INTRODUCTION 2)ANALYSIS CRITERIA Table 1 -Proposed Antenna and Cable Information Table 2-Existing and Reserved Antenna and Cable Information 3)ANALYSIS PROCEDURE Table 3-Documents Provided 3.1)Analysis Method 3.2)Assumptions 4)ANALYSIS RESULTS Table 4-Section Capacity(Summary) Table 5—Tower Components vs. Capacity 5)APPENDIX A tnxTower Output 6)APPENDIX B Base Level Drawing 7)APPENDIX C Additional Calculations tnxTower Report-version 7.0.5.1 94 Ft MonopoleTower Structural Analysis August 22, 2017 Project Number 37517-2565.001.7805,Application 394796,Revision 0 CC/BU No 874135 Page 3 1)INTRODUCTION This tower is a 94 ft Monopole tower designed by SABRE COMMUNICATIONS in June of 2006. The tower was originally designed for a wind speed of 75 mph per TIA/EIA-222-F. 2)ANALYSIS CRITERIA This analysis has been performed in accordance with the 2014 Oregon Structural Specialty Code based upon an ultimate 3-second gust wind speed of 120 mph converted to a nominal 3-second gust wind speed of 93 mph per section 1609.3.1 as required for use in the ANSUTIA-222-G-2005 Standard, "Structural Standard for Antenna Supporting Structures and Antennas", with ANSIITIA-222-G-1-2007 and ANSI/TIA-222-G-2-2009 Addenda per Exception#5 of Section 1609.1.1. Risk Category II, Exposure Category C, and Topographic Category 1 with a crest height of 0 feet were used in this analysis. Table 1 -Proposed Antenna and Cable Information Center Number Mounting Line Antenna Number Feed Level(ft) Elevation °f anfac fkntnasIMUtmerI Antenna Model of Feed LiNote 3 encsson RRUS 11 B13 3 encsson --_._. 65.0 65.0 RRUS 32 B2 - 3 ericsson RRUS 32 B66 4 1-3/8 2 raycap RCMDC-3315-PF-48 tnxTower Report-version 7.0.5.1 94 Ft Monopole Tower Structural Analysis August 22, 2017 CCI BU No Project Number 37517-2565.001.7805,Application 394796, Revision 0 Page 874135 4 Table 2-Existing and Reserved Antenna and Cable Information Center Number Mounting Anten jE5!on °fManufacturerAntennas). 3 alcatel lucent B25 RRH4x30-4R 3 kathrein 800 10866 3 1 kathrein 800 10892V01K ( ! 2 { 3/4 5 powerwave I 2 technologies LGP21401 1 3/8 3 alcatel lucent RRH2x40-700AT ' 3 1 alcatel lucent i RRH4X25-WCS 94.0 , 94.0 ( I 1 1 kathrein 742-264 1 kathrein 800 10121 2 kathrein i 860 10025 I 6 7/8 1 tower mounts ;Platform Mount[LP 1001-1] 1 3/8 1 1 raycap DC6-48-60-18-8F powerwave + LGP21401 1 ' technologies 90 0 90.0 1 tower mounts Side Arm Mount[SO 101- 3] 1 - - . 1 ericsson RRU A2 3 ericsson RRU-12 3 1-1/4 3 12 commscope SBNHH-1 D65C w/Mount 65.0 65.0 Pipe ' 3 ericsson RRUS 11 B13 2 raycap RCMDC 3315-PF-48 1 tower mounts Platform Mount[LP 402-1] Notes: 1) Existing Equipment 2) Reserved Equipment 3) Equipment To Be Removed tnxTower Report-version 7.0.5.1 94 Ft Monopole Tower Structural Analysis Augusto N 22, 2017 CCI BU N Project Number 37517-2565.001.7805,Application 394796,Revision 0 o 874135 Page 5 3)ANALYSIS PROCEDURE Table 3-Documents Provided Document Remarks Reference Source 4-GEOTECHNICAL REPORTS Redmond&Associates, 1356168 r CCISITES 110.149.G, 9/15/00 4-TOWER FOUNDATION ! I I Sabre, 01-03017, 3/19/01 1354402 CCISITES DRAWINGS/DESIGN/SPECS 4-TOWER MANUFACTURER DRAWINGS Sabre, 01-03017, 4/24/01 1354388 CCISITES 3.1) Analysis Method tnxTower(version 7.0.5.1), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. This analysis may be affected if any assumptions are not valid or have been made in error. Paul J Ford and Company should be notified to determine the effect on the structural integrity of the tower. tnxTower Report-version 7.0.5.1 94 Ft Monopole Tower Structural Analysis August 22, 2017 CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 6 4)ANALYSIS RESULTS Table 4-Section Capacity(Summary) Section Elevation(ft) Component Type gee Critical SF*P allow % No. Element P(K) — Pass/Fall (K) Capacity L1 94 50 f Pole TP2513x16x0.25 1 -12 01 1423.67 70.8 I Pass L2 50-0 ( PoleTP34.88x23.9x0.31 2 , -20.66 2479.65 88.8 i Pass Summary Pole(L2) ; 88.8 I Pass Rating= 88.8 Pass Table 5-Tower Component Stresses vs. Capacity—LC7 Notes Component Elevation(ft) % Capacity Pass/Fail 1 Anchor Rods 90.2 0 s_ ! Pass 1 ? Base Plate 097.1 Pass Base Foundation Steel 0 88.1 Pass Base Foundation 1 i Soil Interaction 0 70.7 Pass Structure Rating(max from all components)= 97.1% Notes: 1) See additional documentation in"Appendix C—Additional Calculations"for calculations supporting the%capacity consumed. tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 7 APPENDIX A TNXTOWER OUTPUT tnxTower Report-version 7.0.5.1 94 Ft Monopole Tower Structural Analysis Augusto N 22, 2017 CCI BU N Project Number 37517-2565.001.7805, o 874113835 Application 394796,Revision 0 Page 8 - Tower Input Data - There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: 1) Tower is located in Washington County, Oregon. 2) ASCE 7-10 Wind Data is used (wind speeds converted to nominal values). 3) Basic wind speed of 93 mph. 4) Structure Class II. 5) Exposure Category C. 6) Topographic Category 1. 7) Crest Height 0.00 ft. 8) Nominal ice thickness of 1.25 in. 9) Ice thickness is considered to increase with height. 10) Ice density of 56.00 pcf. 11) A wind speed of 30 mph is used in combination with ice. 12) Temperature drop of 50 °F. 13) Deflections calculated using a wind speed of 60 mph. 14) A non-linear(P-delta)analysis was used. 15) Pressures are calculated at each section. 16) Stress ratio used in pole design is 1. 17) Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Options Consider Moments-Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Consider Moments-Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces Consider Moments-Diagonals J Assume Rigid Index Plate Ignore Redundant Members in FEA Use Moment Magnification 'I Use Clear Spans For Wind Area SR Leg Bolts Resist Compression Use Code Stress Ratios Use Clear Spans For KUr All Leg Panels Have Same Allowable Use Code Safety Factors-Guys Retension Guys To Initial Tension Offset Girt At Foundation Escalate Ice .l Bypass Mast Stability Checks .1 Consider Feed Line Torque Always Use Max Kz l Use Azimuth Dish Coefficients Include Angle Block Shear Check Use Special Wind Profile .4 Project Wind Area of Appurt. Use TIA-222-G Bracing Resist. Exemption Include Botts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-G Tension Splice Exemption Leg Bolts Are At Top Of Section Add IBC.6D+W Combination Poles Secondary Horizontal Braces Leg Sort Capacity Reports By Component .1 Include Shear-Torsion Interaction Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets SR Members Are Concentric Tapered Pole Section Geometry Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius _ ft ft ft Sides in in in _ in L1 94.00-50.00 44.00 3.50 18 16.00 25.13 0.25 1.00 A572-65 (65 ksi) L2 50.00-0.00 53.50 18 23.90 34.88 0.31 1.25 A572-65 (65 ksi) tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796, Revision 0 Page 9 Tapered Pole Properties Section Tip Dia. Area I r C I/C J lt/Q w wit in in2 in4 in in in3 in4 in2 in L1 16.25 12.50 391.68 5.59 8.13 48.19 783.87 6.25 2.38 9.504 25.51 19.74 1543.03 8.83 12.76 120.89 3088.09 9.87 3.98 15.928 L2 25.00 23.40 1644.35 8.37 12.14 135.44 3290.85 11.70 3.66 11.7 35.41 34.28 5173.80 12.27 17.72 292.03 10354.41 17.14 5.59 17.882 Tower Gusset Gusset Gusset GradeAdjust.Factor Adjust. Weight Mu/t. Double Angle Double Angle Double Angle Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt Stitch Bolt (per face) A, Spacing Spacing Spacing Diagonals Horizontals Redundants ft ft2 in in in in L1 94.00- 1 1 1 50.00 L2 50.00-0.00 1 1 1 Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component Placement Total CAAA Weight or Shield Type Number Leg ft ft2/ft Of CR 50 1070(7/8) C No Inside Pole 94.00-0.00 6 No Ice 0.00 0.28 1/2"Ice 0.00 0.28 1"Ice 0.00 0.28 2"Ice 0.00 0.28 12 PAIR(3/8) C No Inside Pole 94.00-0.00 1 No Ice 0.00 0.08 1/2"Ice 0.00 0.08 1"Ice 0.00 0.08 2"Ice 0.00 0.08 12 PAIR(3/8) C No Inside Pole 94.00-0.00 1 No Ice 0.00 0.08 1/2"Ice 0.00 0.08 1"Ice 0.00 0.08 2"Ice 0.00 0.08 RLSS 8AWG DC(3/4) C No Inside Pole 94.00-0.00 2 No Ice 0.00 0.49 1/2"Ice 0.00 0.49 1"Ice 0.00 0.49 2"Ice 0.00 0.49 MLCH HYBRID C No CaAa(Out Of 65.00-0.00 1 No Ice 0.14 1.72 6X12(1-318) Face) 1/2"Ice 0.24 2.89 1"Ice 0.34 4.68 2"Ice 0.54 10.10 MLCH HYBRID C No CaAa(Out Of 65.00-0.00 3 No Ice 0.00 1.72 6X12(1-3/8) Face) 1/2"Ice 0.00 2.89 1"Ice 0.00 4.68 2"Ice 0.00 10.10 Feed Line/Linear Appurtenances Section Areas Tower Tower Face AR AF CAAA CAAA Weight Sectio Elevation In Face Out Face n ft ft2 ft2 ft2 r._ ft2 K L1 94.00-50.00 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 2.145 0.23 L2 50.00-0.00 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 7.150 0.48 Feed Line/Linear Appurtenances Section Areas - With Ice tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 10 Tower Tower Face Ice AR AF CAAA CAAA Weight Sectio Elevation or Thickness In Face Out Face n ft Leg in ft2 ft2 ft2 ft2 K L1 94.00-50.00 A 2.698 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 10.239 1.11 L2 50.00-0.00 A 2.429 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 34.130 3.43 Feed Line Center of Pressure Section Elevation CPx CPZ CPx CPZ Ice Ice ft in in in in L1 94.00-50.00 -0.07 0.04 -0.25 0.14 L2 50.00-0.00 -0.17 0.10 -0.60 0.35 Shielding Factor Ka Tower Feed Line Description Feed Line K, Ka Section Record No. Segment No Ice Ice Elev. Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ° ft B25 RRH4x30-4R A From Leg 4.00 0.000 94.00 No Ice 2.14 1.31 0.05 0 1/2" 2.33 1.46 0.07 0 Ice 2.53 1.63 0.09 _ 1"Ice 2.94 1.98 0.14 2"Ice RRH2x40-700AT A From Leg 4.00 0.000 94.00 No Ice 2.56 1.36 0.05 0 1/2" 2.77 1.53 0.07 0 Ice 2.99 1.71 0.09 1"Ice 3.45 2.09 0.15 2"Ice RRH4X25-WCS A From Leg 4.00 0.000 94.00 No Ice 3.84 3.34 0.09 0 1/2" 4.09 3.59 0.13 0 Ice 4.36 3.84 0.16 1"Ice 4.94 4.38 0.25 2"Ice 800 10866 w/Mount Pipe A From Leg 4.00 0.000 94.00 No Ice 13.84 9.49 0.11 0 1/2" 14.55 11.01 0.21 0 Ice 15.26 12.55 0.32 1"Ice 16.63 14.89 0.57 2"Ice 800 10892V01 K w/Mount A From Leg 4.00 0.000 94.00 No Ice 15.55 10.69 0.13 Pipe 0 1/2" 16.33 12.35 0.24 0 Ice 17.09 14.03 0.36 1"Ice 18.58 16.76 0.63 2"Ice 742-264 w/Mount Pipe B From Leg 4.00 0.000 94.00 No Ice 5.10 4.19 0.06 0 1/2" 5.51 4.89 0.10 tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 11 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ° ft 0 Ice 5.91 5.55 0.15 1"Ice 6.75 6.92 0.27 2"Ice 800 10121 w/Mount Pipe B From Leg 4.00 0.000 94.00 No Ice 5.74 4.95 0.07 0 1/2" 6.34 6.02 0.12 0 Ice 6.86 6.81 0.18 1"Ice 7.91 8.41 0.32 2"Ice (2)860 10025 B From Leg 4.00 0.000 94.00 No Ice 0.14 0.12 0.00 0 1/2" 0.19 0.17 0.00 0 Ice 0.25 0.23 0.01 1"Ice 0.40 0.37 0.01 2"Ice LGP21401 B From Leg 4.00 0.000 94.00 No Ice 1.10 0.35 0.01 0 1/2" 1.24 0.44 0.02 0 Ice 1.38 0.54 0.03 1"Ice 1.69 0.77 0.05 2"Ice B25 RRH4x30-4R B From Leg 4.00 0.000 94.00 No Ice 2.14 1.31 0.05 0 1/2" 2.33 1.46 0.07 0 Ice 2.53 1.63 0.09 1"Ice 2.94 1.98 0.14 2"Ice RRH2x40-700AT B From Leg 4.00 0.000 94.00 No Ice 2.56 1.36 0.05 0 1/2" 2.77 1.53 0.07 0 Ice 2.99 1.71 0.09 1"Ice 3.45 2.09 0.15 2"Ice RRH4X25-WCS B From Leg 4.00 0.000 94.00 No Ice 3.84 3.34 0.09 0 1/2" 4.09 3.59 0.13 0 Ice 4.36 3.84 0.16 1"Ice 4.94 4.38 0.25 2"Ice 800 10866 w/Mount Pipe B From Leg 4.00 0.000 94.00 No Ice 13.84 9.49 0.11 0 1/2" 14.55 11.01 0.21 0 Ice 15.26 12.55 0.32 1"Ice 16.63 14.89 0.57 2"Ice 800 10892V01 K w/Mount B From Leg 4.00 0.000 94.00 No Ice 15.55 10.69 0.13 Pipe 0 1/2" 16.33 12.35 0.24 0 Ice 17.09 14.03 0.36 1"Ice 18.58 16.76 0.63 2"Ice (5)LGP21401 B From Leg 4.00 0.000 94.00 No Ice 1.10 0.35 0.01 0 1/2" 1.24 0.44 0.02 - 0 Ice 1.38 0.54 0.03 1"Ice 1.69 0.77 0.05 2"Ice DC6-48-60-18-8F C From Leg 4.00 0.000 94.00 No Ice 0.92 0.92 0.02 0 1/2" 1.46 1.46 0.04 0 Ice 1.64 1.64 0.06 1"Ice 2.04 2.04 0.11 2"Ice B25 RRH4x30-4R C From Leg 4.00 0.000 94.00 No Ice 2.14 1.31 0.05 0 1/2" 2.33 1.46 0.07 0 Ice 2.53 1.63 0.09 1"Ice 2.94 1.98 0.14 2"Ice RRH2x40-700AT C From Leg 4.00 0.000 94.00 No Ice 2.56 1.36 0.05 0 1/2" 2.77 1.53 0.07 0 Ice 2.99 1.71 0.09 1"Ice 3.45 2.09 0.15 2"Ice RRH4X25-WCS C From Leg 4.00 0.000 94.00 No Ice 3.84 3.34 0.09 0 1/2" 4.09 3.59 0.13 tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 12 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ° ft 0 Ice 4.36 3.84 0.16 1"Ice 4.94 4.38 0.25 2"Ice 800 10866 w/Mount Pipe C From Leg 4.00 0.000 94.00 No Ice 13.84 9.49 0.11 0 1/2" 14.55 11.01 0.21 0 Ice 15.26 12.55 0.32 1"Ice 16.63 14.89 0.57 2"Ice 800 10892V01 K w/Mount C From Leg 4.00 0.000 94.00 No Ice 15.55 10.69 0.13 Pipe 0 1/2" 16.33 12.35 0.24 0 Ice 17.09 14.03 0.36 1"Ice 18.58 16.76 0.63 2"Ice Platform Mount[LP 1001- C None 0.000 94.00 No Ice 47.70 47.70 3.02 1] 1/2" 59.50 59.50 3.62 Ice 71.30 71.30 4.22 1"Ice 94.90 94.90 5.43 2"Ice (2)6'x 2"Mount Pipe A From Leg 2.00 0.000 90.00 No Ice 1.43 1.43 0.02 0 1/2" 1.92 1.92 0.03 0 Ice 2.29 2.29 0.05 1"Ice 3.06 3.06 0.09 2"Ice (2)6'x 2"Mount Pipe B From Leg 2.00 0.000 90.00 No Ice 1.43 1.43 0.02 O 1/2" 1.92 1.92 0.03 O Ice 2.29 2.29 0.05 1"Ice 3.06 3.06 0.09 2"Ice (2)6'x 2"Mount Pipe C From Leg 2.00 0.000 90.00 No Ice 1.43 1.43 0.02 0 1/2" 1.92 1.92 0.03 O Ice 2.29 2.29 0.05 1"Ice 3.06 3.06 0.09 2"Ice Side Arm Mount[SO 101- C None 0.000 90.00 No Ice 7.50 7.50 0.25 3] 1/2" 8.90 8.90 0.33 Ice 10.30 10.30 0.41 1"Ice 13.10 13.10 0.58 2"Ice ... (4)SBNHH-1D65C w/ A From Leg 4.00 0.000 65.00 No Ice 11.86 10.03 0.09 Mount Pipe 0 1/2" 12.69 11.65 0.18 0 Ice 13.52 13.29 0.28 1"Ice 15.05 15.97 0.52 2"Ice (2)RCMDC-3315-PF-48 A From Leg 4.00 0.000 65.00 No Ice 3.36 2.19 0.03 0 1/2" 3.60 2.39 0.06 0 Ice 3.84 2.61 0.09 1"Ice 4.34 3.05 0.17 2"Ice (2)RRUS 11 B13 A From Leg 4.00 0.000 65.00 No Ice 2.79 1.19 0.05 0 1/2" 3.00 1.34 0.07 0 Ice 3.21 1.50 0.10 1"Ice 3.67 1.84 0.15 2"Ice RRUS 32 B2 A From Leg 4.00 0.000 65.00 No Ice 2.73 1.67 0.05 0 1/2" 2.95 1.86 0.07 0 Ice 3.18 2.05 0.10 1"Ice 3.66 2.46 0.16 2"Ice RRUS 32 B66 A From Leg 4.00 0.000 65.00 No Ice 2.74 1.67 0.05 0 1/2" 2.96 1.86 0.07 0 Ice 3.19 2.05 0.10 1"Ice 3.68 2.46 0.16 2"Ice tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 13 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Hoa Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ° _ _ _ ft _ RCMDC-3315-PF-48 B From Leg ^4.00 0.000 65.00 No Ice 3.36 2.19 0.03 0 1/2" 3.60 2.39 0.06 0 Ice 3.84 2.61 0.09 1"Ice 4.34 3.05 0.17 2"Ice (4)SBNHH-1 D65C w/ B From Leg 4.00 0.000 65.00 No Ice 11.86 10.03 0.09 Mount Pipe 0 1/2" 12.69 11.65 0.18 0 Ice 13.52 13.29 0.28 1"Ice 15.05 15.97 0.52 2"Ice RRUS 11 B13 B From Leg 4.00 0.000 65.00 No Ice 2.79 1.19 0.05 0 1/2" 3.00 1.34 0.07 0 Ice 3.21 1.50 0.10 1"Ice 3.67 1.84 0.15 2"Ice RRUS 32 B2 B From Leg 4.00 0.000 65.00 No Ice 2.73 1.67 0.05 0 1/2" 2.95 1.86 0.07 0 Ice 3.18 2.05 0.10 1"Ice 3.66 2.46 0.16 2"Ice RRUS 32 B66 B From Leg 4.00 0.000 65.00 No Ice 2.74 1.67 0.05 0 1/2" 2.96 1.86 0.07 0 Ice 3.19 2.05 0.10 1"Ice 3.68 2.46 0.16 2"Ice RCMDC-3315-PF-48 C From Leg 4.00 0.000 65.00 No Ice 3.36 2.19 0.03 0 1/2" 3.60 2.39 0.06 0 Ice 3.84 2.61 0.09 1"Ice 4.34 3.05 0.17 2"Ice RRUS 11 B13 C From Leg 4.00 0.000 65.00 No Ice 2.79 1.19 0.05 0 1/2" 3.00 1.34 0.07 0 Ice 3.21 1.50 0.10 1"Ice 3.67 1.84 0.15 2"Ice (4)SBNHH-1 D65C w/ C From Leg 4.00 0.000 65.00 No Ice 11.86 10.03 0.09 Mount Pipe 0 1/2" 12.69 11.65 0.18 0 Ice 13.52 13.29 0.28 1"Ice 15.05 15.97 0.52 2"Ice RRUS 32 B66 C From Leg 4.00 0.000 65.00 No Ice 2.74 1.67 0.05 0 1/2" 2.96 1.86 0.07 0 Ice 3.19 2.05 0.10 1"Ice 3.68 2.46 0.16 2"Ice RRUS 32 B2 C From Leg 4.00 0.000 65.00 No Ice 2.73 1.67 0.05 0 1/2" 2.95 1.86 0.07 0 Ice 3.18 2.05 0.10 1"Ice 3.66 2.46 0.16 2"Ice Platform Mount[LP 402-1] C None 0.000 65.00 No Ice 33.04 33.04 2.17 1/2" 43.38 43.38 2.68 Ice 53.72 53.72 3.19 1"Ice 74.40 74.40 4.21 2"Ice ... (2)5'x 2'Pipe Mount A From Leg 4.00 0.000 94.00 No Ice 1.00 1.00 0.03 0 1/2" 1.39 1.39 0.04 0 Ice 1.70 1.70 0.05 1"Ice 2.35 2.35 0.08 2"Ice (2)5'x 2'Pipe Mount C From Leg 4.00 0.000 94.00 No Ice 1.00 1.00 0.03 0 1/2" 1.39 1.39 0.04 0 Ice 1.70 1.70 0.05 1"Ice 2.35 2.35 0.08 tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 14 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft " ft 2"Ice Tower Pressures - No Ice GH=1.100 Section z Kz qz AG F AF AR Am, Leg CAAA CAAA Elevation a % In Out c Face Face ft ft psf ft2 e ft2 ft2 ft2 ft2 ft2 L1 94.00- 70.73 1.177 24.67 76.559 A 0.000 76.559 76.559 100.00 0.000 0.000 50.00 B 0.000 76.559 100.00 0.000 0.000 C 0.000 76.559 100.00 0.000 2.145 L2 50.00-0.00 24.74 0.943 19.58 125.85 A 0.000 125.854 125.854 100.00 0.000 0.000 4 B 0.000 125.854 100.00 0.000 0.000 C 0.000 125.854 100.00 0.000 7.150 Tower Pressure - With Ice GH=1.100 Section z Kz q: tz AG F AF AR A,v Leg CAAA CAAA Elevation a % In Out c Face Face ft ft psf in ft2 e ft2 ft2 ft2 ft2 ft2 L1 94.00-50.00 70.73 1.177 2.57 2.70 96.344 A 0.000 96.344 96.344 100.00 0.000 0.000 B 0.000 96.344 100.00 0.000 0.000 C 0.000 96.344 100.00 0.000 10.239 L2 50.00-0.00 24.74 0.943 2.04 2.43 148.338 A 0.000 148.338 148.338 100.00 0.000 0.000 B 0.000 148.338 100.00 0.000 0.000 C 0.000 148.338 100.00 0.000 34.130 Tower Pressure - Service GH=1.100 Section z Kz q: AG F AF AR Aleg Leg CAAA CAAA Elevation a % In Out c Face Face ft ft psf ft2 e ft2 ft2 ft2 ft2 ft2 LI 94.00- 70.73 1.177 9.19 76.559 A 0.000 76.559 76.559 100.00 0.000 0.000 50.00 B 0.000 76.559 100.00 0.000 0.000 C 0.000 76.559 100.00 0.000 2.145 L2 50.00-0.00 24.74 0.943 7.29 125.85 A 0.000 125.854 125.854 100.00 0.000 0.000 4 B 0.000 125.854 100.00 0.000 0.000 C 0.000 125.854 100.00 0.000 7.150 Load Combinations tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 15 Comb. Description No. 1 Dead Only 2 1.2 Dead+1.6 Wind 0 deg-No Ice 3 0.9 Dead+1.6 Wind 0 deg-No Ice 4 1.2 Dead+1.6 Wind 30 deg-No Ice 5 0.9 Dead+1.6 Wind 30 deg-No Ice 6 1.2 Dead+1.6 Wind 60 deg-No Ice 7 0.9 Dead+1.6 Wind 60 deg-No Ice 8 1.2 Dead+1.6 Wind 90 deg-No Ice 9 0.9 Dead+1.6 Wind 90 deg-No Ice 10 1.2 Dead+1.6 Wind 120 deg-No Ice 11 0.9 Dead+1.6 Wind 120 deg-No Ice 12 1.2 Dead+1.6 Wind 150 deg-No Ice 13 0.9 Dead+1.6 Wind 150 deg-No Ice 14 1.2 Dead+1.6 Wind 180 deg-No Ice 15 0.9 Dead+1.6 Wind 180 deg-No Ice 16 1.2 Dead+1.6 Wind 210 deg-No Ice 17 0.9 Dead+1.6 Wind 210 deg-No Ice 18 1.2 Dead+1.6 Wind 240 deg-No Ice 19 0.9 Dead+1.6 Wind 240 deg-No Ice 20 1.2 Dead+1.6 Wind 270 deg-No Ice 21 0.9 Dead+1.6 Wind 270 deg-No Ice 22 1.2 Dead+1.6 Wind 300 deg-No Ice 23 0.9 Dead+1.6 Wind 300 deg-No Ice 24 1.2 Dead+1.6 Wind 330 deg-No Ice 25 0.9 Dead+1.6 Wind 330 deg-No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg-Service 40 Dead+Wind 30 deg-Service 41 Dead+Wind 60 deg-Service 42 Dead+Wind 90 deg-Service 43 Dead+Wind 120 deg-Service 44 Dead+Wind 150 deg-Service 45 Dead+Wind 180 deg-Service 46 Dead+Wind 210 deg-Service 47 Dead+Wind 240 deg-Service 48 Dead+Wind 270 deg-Service 49 Dead+Wind 300 deg-Service 50 Dead+Wind 330 deg-Service Maximum Member Forces Sectio Elevation Component Condition Gov. Axial Major Axis Minor Axis n ft Type Load Moment Moment No. ___.. Comb. K kip-ft _kip-ft__ L1 94-50 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -43.00 -4.24 -2.02 Max.Mx 8 -12.03 -489.52 -5.43 Max.My 14 -12.04 -5.84 -484.06 Max.Vy 8 18.45 -489.52 -5.43 Max.Vx 14 18.39 -5.84 -484.06 Max.Torque 16 2.01 L2 50-0 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -58.63 -0.74 -4.39 Max.Mx 8 -20.66 -1539.69 -12.73 tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 16 Sectio Elevation Component Condition Gov. Axial Major Axis Minor Axis n ft Type Load Moment Moment No. Comb. K kip-ft kip-ft Max.My 14 -20.66 -12.46 -1532.04 Max.Vy 8 20.69 -1539.69 -12.73 Max.Vx 14 20.64 -12.46 -1532.04 Max.Torque 16 1.68 Maximum Reactions Location Condition Gov. Vertical Horizontal,X Horizontal,Z Load K K K Comb. Pole Max.Vert 26 58.63 0.00 0.00 Max.Hx 21 15.53 20.65 0.13 Max.Hz 2 20.70 0.13 20.60 Max.Mx 2 1531.46 0.13 20.60 Max.Mz 8 1539.69 -20.65 -0.13 Max.Torsion 16 1.52 10.22 -17.78 Min.Vert 21 15.53 20.65 0.13 Min.Hx 9 15.53 -20.65 -0.13 Min.Hi 15 15.53 -0.13 -20.60 Min.Mx 14 -1532.04 -0.13 -20.60 Min.MZ 20 -1539.54 20.65 0.13 Min.Torsion 4 -1.52 -10.22 17.78 Tower Mast Reaction Summary Load Vertical Shearx Shear Overturning Overturning Torque Combination Moment,Mx Moment,MZ K K K kip-ft kip-ft kip-ft Dead Only 17.25 -0.00 -0.00 0.23 0.00 -0.00 1.2 Dead+1.6 Wind 0 deg- 20.70 -0.13 -20.60 -1531.46 12.45 1.29 No Ice 0.9 Dead+1.6 Wind 0 deg- 15.53 -0.13 -20.60 -1512.94 12.28 1.27 No Ice 1.2 Dead+1.6 Wind 30 deg- 20.70 10.22 -17.78 -1320.10 -759.13 1.52 No Ice 0.9 Dead+1.6 Wind 30 deg- 15.53 10.22 -17.78 -1304.20 -749.93 1.50 No Ice 1.2 Dead+1.6 Wind 60 deg- 20.70 17.82 -10.19 -754.84 -1327.28 1.34 No Ice 0.9 Dead+1.6 Wind 60 deg- 15.53 17.82 -10.19 -745.79 -1311.17 1.32 No Ice 1.2 Dead+1.6 Wind 90 deg- 20.70 20.65 0.13 12.73 -1539.69 0.80 No Ice 0.9 Dead+1.6 Wind 90 deg- 15.53 20.65 0.13 12.49 -1521.01 0.79 No Ice 1.2 Dead+1.6 Wind 120 deg 20.70 17.95 10.41 776.91 -1339.62 0.05 -No Ice 0.9 Dead+1.6 Wind 120 deg 15.53 17.95 10.41 767.41 -1323.35 0.05 -No Ice 1.2 Dead+1.6 Wind 150 deg 20.70 10.44 17.91 1333.02 -780.64 -0.71 -No Ice 0.9 Dead+1.6 Wind 150 deg 15.53 10.44 17.91 1316.79 -771.14 -0.71 -No Ice 1.2 Dead+1.6 Wind 180 deg 20.70 0.13 20.60 1532.04 -12.46 -1.29 -No Ice 0.9 Dead+1.6 Wind 180 deg 15.53 0.13 20.60 1513.43 -12.28 -1.27 -No Ice 1.2 Dead+1.6 Wind 210 deg 20.70 -10.22 17.78 1320.66 759.11 -1.52 -No Ice 0.9 Dead+1.6 Wind 210 deg 15.53 -10.22 17.78 1304.61 749.93 -1.50 -No Ice tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 17 Load Vertical Shear Shear Overturning Overturning Torque Combination Moment,M, Moment,Mx K K K kip-ft kip-ft _ kip-ft 1.2 Dead+1.6 Wind 240 deg 20.70 -17.82 10.19 755.39 1327.24 -1.34 -No Ice 0.9 Dead+1.6 Wind 240 deg 15.53 -17.82 10.19 746.19 1311.16 -1.32 -No Ice 1.2 Dead+1.6 Wind 270 deg 20.70 -20.65 -0.13 -12.18 1539.54 -0.80 -No Ice 0.9 Dead+1.6 Wind 270 deg 15.53 -20.65 -0.13 -12.07 1520.92 -0.79 -No Ice 1.2 Dead+1.6 Wind 300 deg 20.70 -17.95 -10.41 -776.33 1339.57 -0.05 -No Ice 0.9 Dead+1.6 Wind 300 deg 15.53 -17.95 -10.41 -766.98 1323.32 -0.04 -No Ice 1.2 Dead+1.6 Wind 330 deg 20.70 -10.44 -17.91 -1332.43 780.61 0.71 -No Ice 0.9 Dead+1.6 Wind 330 deg 15.53 -10.44 -17.91 -1316.36 771.13 0.71 -No Ice 1.2 Dead+1.0 Ice+1.0 Temp 58.63 -0.00 -0.00 4.39 -0.74 0.00 1.2 Dead+1.0 Wind 0 58.63 -0.01 -2.78 -220.52 -0.14 0.17 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 30 58.63 1.38 -2.41 -190.05 -112.77 0.26 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 60 58.63 2.40 -1.39 -107.45 -195.40 0.27 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 90 58.63 2.78 0.01 5.14 -225.89 0.21 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 120 58.63 2.41 1.40 117.58 -196.10 0.10 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 150 58.63 1.39 2.41 199.72 -113.93 -0.05 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 180 58.63 0.01 2.78 229.49 -1.45 -0.17 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 210 58.63 -1.38 2.41 199.02 111.19 -0.26 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 240 58.63 -2.40 1.39 116.42 193.81 -0.27 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 270 58.63 -2.78 -0.01 3.83 224.30 -0.21 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 300 58.63 -2.41 -1.40 -108.58 194.47 -0.10 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 330 58.63 -1.39 -2.41 -190.70 112.32 0.05 deg+1.0 Ice+1.0 Temp Dead+Wind 0 deg-Service 17.25 -0.03 -4.79 -354.16 2.86 0.38 Dead+Wind 30 deg-Service 17.25 2.38 -4.14 -305.24 -175.65 0.40 Dead+Wind 60 deg-Service 17.25 4.15 -2.37 -174.47 -307.09 0.31 Dead+Wind 90 deg-Service 17.25 4.81 0.03 3.12 -356.26 0.14 Dead+Wind 120 deg- 17.25 4.18 2.42 179.93 -309.97 -0.07 Service Dead+Wind 150 deg- 17.25 2.43 4.17 308.60 -180.63 -0.26 Service Dead+Wind 180 deg- 17.25 0.03 4.79 354.64 -2.90 -0.38 Service Dead+Wind 210 deg- 17.25 -2.38 4.14 305.72 175.61 -0.40 Service Dead+Wind 240 deg- 17.25 -4.15 2.37 174.94 307.06 -0.31 Service Dead+Wind 270 deg- 17.25 -4.81 -0.03 -2.64 356.22 -0.14 Service Dead+Wind 300 deg- 17.25 -4.18 -2.42 -179.46 309.93 0.07 Service Dead+Wind 330 deg- 17.25 -2.43 -4.17 -308.12 180.60 0.26 Service Solution Summary tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 18 Sum of Applied Forces Sum of Reactions Load PX PY PZ PX PY PZ %Error Comb. K K K K K K 1 0.00 -17.25 0.00 0.00 17.25 0.00 0.000% 2 -0.13 -20.70 -20.60 0.13 20.70 20.60 0.002% 3 -0.13 -15.53 -20.60 0.13 15.53 20.60 0.004% 4 10.22 -20.70 -17.78 -10.22 20.70 17.78 0.000% 5 10.22 -15.53 -17.78 -10.22 15.53 17.78 0.000% 6 17.82 -20.70 -10.19 -17.82 20.70 10.19 0.000% 7 17.82 -15.53 -10.19 -17.82 15.53 10.19 0.000% 8 20.65 -20.70 0.13 -20.65 20.70 -0.13 0.002% 9 20.65 -15.53 0.13 -20.65 15.53 -0.13 0.001% 10 17.95 -20.70 10.41 -17.95 20.70 -10.41 0.000% 11 17.95 -15.53 10.41 -17.95 15.53 -10.41 0.000% 12 10.44 -20.70 17.91 -10.44 20.70 -17.91 0.000% 13 10.44 -15.53 17.91 -10.44 15.53 -17.91 0.000% 14 0.13 -20.70 20.60 -0.13 20.70 -20.60 0.002% 15 0.13 -15.53 20.60 -0.13 15.53 -20.60 0.001% 16 -10.22 -20.70 17.78 10.22 20.70 -17.78 0.000% 17 -10.22 -15.53 17.78 10.22 15.53 -17.78 0.000% 18 -17.82 -20.70 10.19 17.82 20.70 -10.19 0.000% 19 -17.82 -15.53 10.19 17.82 15.53 -10.19 0.000% 20 -20.65 -20.70 -0.13 20.65 20.70 0.13 0.005% 21 -20.65 -15.53 -0.13 20.65 15.53 0.13 0.004% 22 -17.95 -20.70 -10.41 17.95 20.70 10.41 0.000% 23 -17.95 -15.53 -10.41 17.95 15.53 10.41 0.000% 24 -10.44 -20.70 -17.91 10.44 20.70 17.91 0.000% 25 -10.44 -15.53 -17.91 10.44 15.53 17.91 0.000% 26 0.00 -58.63 0.00 0.00 58.63 0.00 0.001% 27 -0.01 -58.63 -2.78 0.01 58.63 2.78 0.001% 28 1.38 -58.63 -2.41 -1.38 58.63 2.41 0.001% 29 2.40 -58.63 -1.39 -2.40 58.63 1.39 0.001% 30 2.78 -58.63 0.01 -2.78 58.63 -0.01 0.001% 31 2.41 -58.63 1.40 -2.41 58.63 -1.40 0.000% 32 1.39 -58.63 2.41 -1.39 58.63 -2.41 0.000% 33 0.01 -58.63 2.78 -0.01 58.63 -2.78 0.001% 34 -1.38 -58.63 2.41 1.38 58.63 -2.41 0.001% 35 -2.40 -58.63 1.39 2.40 58.63 -1.39 0.001% 36 -2.78 -58.63 -0.01 2.78 58.63 0.01 0.001% 37 -2.41 -58.63 -1.40 2.41 58.63 1.40 0.001% 38 -1.39 -58.63 -2.41 1.39 58.63 2.41 0.001% 39 -0.03 -17.25 -4.80 0.03 17.25 4.79 0.006% 40 2.38 -17.25 -4.14 -2.38 17.25 4.14 0.005% 41 4.15 -17.25 -2.37 -4.15 17.25 2.37 0.006% 42 4.81 -17.25 0.03 -4.81 17.25 -0.03 0.006% 43 4.18 -17.25 2.42 -4.18 17.25 -2.42 0.006% 44 2.43 -17.25 4.17 -2.43 17.25 -4.17 0.006% 45 0.03 -17.25 4.80 -0.03 17.25 -4.79 0.006% 46 -2.38 -17.25 4.14 2.38 17.25 -4.14 0.005% 47 -4.15 -17.25 2.37 4.15 17.25 -2.37 0.005% 48 -4.81 -17.25 -0.03 4.81 17.25 0.03 0.006% 49 -4.18 -17.25 -2.42 4.18 17.25 2.42 0.006% .. 50 -2.43 -17.25 -4.17 2.43 17.25 4.17 0.006% Non-Linear Convergence Results Load Converged? Number Displacement Force Combination of Cycles Tolerance Tolerance 1 Yes 6 0.00000001 0.00000001 2 Yes 13 0.00000001 0.00006650 3 Yes 12 0.00000001 0.00014540 4 Yes 15 0.00000001 0.00009607 5 Yes 15 0.00000001 0.00006296 6 Yes 15 0.00000001 0.00008814 7 Yes 15 0.00000001 0.00005759 8 Yes 13 0.00000001 0.00007332 9 Yes 13 0.00000001 0.00005249 10 Yes 15 0.00000001 0.00009617 tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 19 11 Yes 15 0.00000001 0.00006271 12 Yes 15 0.00000001 0.00009823 - 13 Yes 15 0.00000001 0.00006415 14 Yes 13 0.00000001 0.00009979 15 Yes 13 0.00000001 0.00007174 16 Yes 15 0.00000001 0.00008725 - 17 Yes 15 0.00000001 0.00005702 18 Yes 15 0.00000001 0.00009570 19 Yes 15 0.00000001 0.00006269 20 Yes 12 0.00006056 0.00014616 21 Yes 12 0.00000001 0.00010941 22 Yes 15 0.00000001 0.00009601 23 Yes 15 0.00000001 0.00006270 24 Yes 15 0.00000001 0.00009340 25 Yes 15 0.00000001 0.00006094 26 Yes 10 0.00000001 0.00000516 27 Yes 13 0.00000001 0.00002175 28 Yes 13 0.00000001 0.00003342 29 Yes 13 0.00000001 0.00003047 30 Yes 13 0.00000001 0.00002292 31 Yes 14 0.00000001 0.00001576 32 Yes 14 0.00000001 0.00001594 33 Yes 13 0.00000001 0.00002323 34 Yes 13 0.00000001 0.00003019 35 Yes 13 0.00000001 0.00003298 36 Yes 13 0.00000001 0.00002137 37 Yes 13 0.00000001 0.00002897 38 Yes 13 0.00000001 0.00002874 39 Yes 11 0.00000001 0.00014071 40 Yes 11 0.00000001 0.00014845 41 Yes 11 0.00000001 0.00010959 42 Yes 11 0.00000001 0.00013835 43 Yes 11 0.00000001 0.00012446 44 Yes 11 0.00000001 0.00013995 45 Yes 11 0.00000001 0.00014248 46 Yes 11 0.00000001 0.00010726 47 Yes 11 0.00000001 0.00014419 48 Yes 11 0.00000001 0.00013711 49 Yes 11 0.00000001 0.00012744 50 Yes 11 0.00000001 0.00011373 Maximum Tower Deflections - Service Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° L1 94-50 18.530 43 1.680 0.012 L2 53.5-0 6.230 43 1.088 0.003 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft 94.00 B25 RRH4x30-4R 43 18.530 1.680 0.012 16285 90.00 (2)6'x 2"Mount Pipe 43 17.155 1.626 0.011 16285 65.00 (4)SBNHH-1 D65C w/Mount 43 9.152 1.273 0.005 2807 Pipe Maximum Tower Deflections - Design Wind tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 20 Section Elevation Holz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° ° L1 94-50 79.840 10 7.241 0.049 L2 53.5-0 26.906 10 4.703 0.010 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ° ft 94.00 B25 RRH4x30-4R 10 79.840 7.241 0.050 3873 90.00 (2)6'x 2"Mount Pipe 10 73.926 7.012 0.045 3873 65.00 (4)SBNHH-1 D65C w/Mount 10 39.489 5.501 0.019 663 Pipe Compression Checks Pole Design Data Section Elevation Size L Lu KM. A Pu OP„ Ratio No. Pu ft ft ft in K K OP„ L1 94-50(1) TP25.13x16x0.25 44.00 0.00 0.0 19.16 -12.01 1423.67 0.008 L2 50-0(2) TP34.88x23.9x0.31 53.50 0.00 0.0 34.28 -20.66 2479.65 0.008 Pole Bending Design Data Section Elevation Size Mux 4M0x Ratio Muy OM„y Ratio No. Mux Muy ft - kip-ft kip-ft 4M0,, kip-ft kip-ft piny L1 W 94-50(1)' TP25.13x16x0.25 492.88 705.23 0.699 0.00 705.23 0.000 L2 50-0(2) TP34.88x23.9x0.31 1548.61 1760.28 0.880 0.00 1760.28 0.000 Pole Shear Design Data Section Elevation Size Actual OV„ Ratio Actual T. Ratio No. Vu Vu Tu Tu ft K K OV„ kip-ft kip-ft OT,, L1 94-50(1) TP25.13x16x0.25 18.55 711.83 0.026 0.22 1412.18 0.000 L2 50-0(2) TP34.88x23.9x0.31 20.79 1239.83 0.017 0.05 3524.85 0.000 tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 21 Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. Pu Mex M,,, Vu T„ Stress Stress _ ft $Pn OMnz lM„y 016, i,T„ Ratio Ratio L1 94-50(1) 0.008 0.699 0.000 0.026 0.000 0.708 1.000 4.8.2 V V L2 50-0(2) 0.008 0.880 0.000 0.017 0.000 0.888 1.000 482 V V Section Capacity Table Section Elevation Component Size Critical P OPapow % Pass No. ft Type Element K K Capacity Fail L1 94-50 Pole TP25.13x16x0.25 1 -12.01 1423.67 70.8 Pass L2 50-0 Pole TP34.88x23.9x0.31 2 -20.66 2479.65 88.8 Pass Summary Pole(L2) 88.8 Pass RATING= 88.8 Pass tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 22 APPENDIX B BASE LEVEL DRAWING COMBING PEGS • (PPOSEE) oo BO (4),_s/a To 65 LEvE. 014.49110)—TO BE R ) • (B)3)1-1/4"TO 65 FT LEVEL f Q4 0) (RESERVED) Q3 Q2 ()3/4TO (TR LEVEL L ONSINLED—TO BE PENOVEO) (1) /e'N 94 FI LEVEL 0: (4) 3/4'TO 94 R LEVEL (5) 7/13.TO 94 PT LEVEL \%\ (R) 1-5/01'TO 94 F1 LEVEL ( O/B41)94 R LEVEL •904. (e) lir TO 94 R LEVEL �:•4 • • tnxTower Report-version 7.0.5.1 August 22, 2017 94 Ft Monopole Tower Structural Analysis CCI BU No 874135 Project Number 37517-2565.001.7805,Application 394796,Revision 0 Page 23 APPENDIX C ADDITIONAL CALCULATIONS tnxTower Report-version 7.0.5.1 Ilia 94.011 ' I '�� ' t DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE ELEVATION I'1 B25 RRH4x30-4R 94 (2)5'x2'Pipe Mount 94 RRH2x40.700AT 94 (2)5'x 2'Pipe Mount 94 RRH4X25-WCS 94 (2)6 x 2"Mount Pipe 90 800 10866 w/Mount Pipe 94 Side Ann Mount ISO 101-3] 90 _ 800 10892V01K w/Mount Pipe 94 (2)6'x2"Mount Pipe 90 742-264 w/Mount Pipe 94 (2)6'x 2"Mount Pipe 90 ' 800 10121 w/Mount Pipe 94 (2)RRUS 11 B13 65 (2)860 10025 94 RRUS 32 B2 65 LGP21401 94 RRUS 32 B66 65 B25 RRH4x304R 94 RCMDC-3315-PF-48 65 III' RRH2x40.700AT 94 (4)SBNHH-1D65C w/Mount Pipe 65 RRH4X25-WCS 94 RRUS 11 B13 65 800 10866 w/Mount Pipe 94 RRUS 32 B2 65 800 10892V01K w/Mount Pipe 94 RRUS 32 B66 65 c ro N S c I (5)LGP21401 94 RCMDC-3315-PF-48 65 o ,4 .° N 7ii, DC6-48-60-18-8F 94 RRUS 11 B13 65 B25 RRH4x30.4R 94 (4)SBNHH-1D65C w/Mount Pipe 65 I RRH2x40-700AT 94 RRUS 32 B66 65 RRH4X25-WCS 94 RRUS 32 62 65 �' Ill '�� 80010866 w/Mount Pipe94 (4)SBNPlatform H-1DMoun5P 402-o 65 800 10892V01K w/Mount Pipe 94 (4)SBNHH-1D65C w/Mount Pipe 65 PtaHonn Mount ILP 1001-1] 94 (2)RCMDC•3315-PF48 65 MATERIAL STRENGTH GRADE Fy Fu GRADE 1 Fy I Fu A572-65 65 ksi 80 ksi i TOWER DESIGN NOTES / Tower is located in Washington County,Oregon. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 93 mph basic wind in accordance with the TIA-222-G Standard. 4 50.o n _ 4. Tower is also designed for a 30 mph basic wind with 1.25 in ice.Ice is considered to increase in thickness with height. a i 1 O 5. Deflections are based upon a 60 mph wind. 6. Tower Structure Class II. i 7. Topographic Category 1 with Crest Height of 0.00 ft 1 8. TOWER RATING:88.8% 1 E3. i 1 I 2c N m f7 N 8 N p O N M 1 ALL REACTIONS 1 ! ARE FACTORED ;, AXIAL 59 K 1� SHEAR---- ...f--.. f MOMENT 3 K 1230 kip-ft TORQUE 0 kip-ft 30 mph WIND-1.25 in ICE AXIAL it 21K 1,1 ' SHEA MOMENT 'I 21K/ 1549 kip-ft 0.0 9 , 1i TORQUE 2 kip-ft m v REACTIONS-93 mph WIND q $ S' E 11 i. '8 O O a rn N 3 Z f N 12 m (7 PJF b: Paul J Ford and Company Jo94'Monopole/Tigard,OR 250 E. Broad Street Suite 600 PfojeCt'37517-2565 BU 874135 Coilumbus,OH 43215 C11e"t Crown Castle Drawn by:Jared Smith Aped. Phone:614.221.6679 Code:TIA-222-G Date.08/22/17 scale: NTS FAX:614.448.4105 Path:ovowEnon �u u num,a v.,u w.r.n�n s,Hssu m.,a ,..hnvw n,,.n n.w z Dwg No.E-1 PJF Job No. 37517-2565.001 Project Name: BU 874135 Engineer: JWS page 1 Factored Foundation Loads: LC1 LC2 Factored Axial Load (+Comp,-Ten)= 21 15.75 kips 5 ft Round Factored Horiz. Load at Top of Pier= 21 21 kips Concrete Vol= $ Factored OTM at Top of Pier= 1549 1549 k-ft 29.67 yd"3 r LRFD Resistance and Load Factors: CD Dead Load Factors 'I I1_I I I' I I I I_I I I' a! ♦ A Soil Bearing = 0.75 Soil Weight= 0.75 1.2 0.9 (16)#9 Vert Bars o Concrete Weight= 0.75 1.2 0.9 #4 Ties m Soil Properties: °' = Depth to Water Table= 99 ft H co u) 6 Uplift Cone from Top of footing (18)#7 Rebar I `m Ili Top and Bottom i U id T Soil Wedges have been included to counteract overturning. o I o o v Layer Soil Cohesion Friction Ult Depth .,(� `� Thk Density Angle Bearing 0 T Q N, • • ft pcf ksf degrees ksf ft ♦i♦ ♦ • A • • • , 6 110 0 30 12.5 6.00 (18)#7 Rebar i Top and Bottom i I 6.625 ksf 7.538fti? Dimensions: 216.6 kips Pier Shape= Round Pier Width = 5 ft Diameter 1.923 ft Pier Height above Grade= 1 ft 141 o. Depth to Bottom of Footing= 5.5 ft Footing Thickness= 2.5 ft4 17 ft x 17 ft 10 Footing Width, B= 17 ft Footing Length, L= 17 ft Concrete: Total Pad Reinf Stl= 21.60 inA2>= 11.02 inA2= Min StI, OK Concrete Strength = 4 ksi Total Pier Reinf St!= 16.00 inA2>= 14.14 inA2= Min StI, OK Rebar Strength= 60 ksi Footing Thickness= 2.50 ft>= 1.5 ft= Min Ftg Thk, OK Summary Results: Required Available Maximum Net Soil Bearing= 6.625 ksf 9.375 ksf Stress Ratio= 70.7% in Soil Bearing Uplift= 0.0 kips 172.4 kips Stress Ratio= 0.0% in Uplift Punching Shear Stress= 0.043 ksi 0.190 ksi Stress Ratio= 22.7% in Punching Shear Bending Shear Stress= 175.0 kips 497.1 kips Stress Ratio= 35.2% in Bending Shear Bending Moment= 897.22 k-ft 1225.7 k-ft Stress Ratio= 73.2% in Bending Moment Conc Pier Reinforcing Steel= 1633.0 k-ft 1853.6 k-ft Stress Ratio= 88.1% in Pier Rebar v4.3,Effective 01/31/2017 Stiffened or Unstiffened, Ungrouted, Circular Base Plate -Any Rod Material TIA Rev G Assumption: Clear space between bottom of leveling nut and top of concrete not exceeding(1)*(Rod Diameter) - Site Data Reactions BU#: Mu:. 1549 ft-kips Site Name: Axial,Pu: 21 kips - App#: Shear,Vu: 21 kips Pole Manufacturer:I Other I Eta Factor, rl 0.5 TIA G(Fig.4-4) Anchor Rod Data Ilf No stiffeners,Criteria: I AISC LRFD <-Only Applcable to Unstiffened Cases Qty: 8 Diam: 2.25 in Rod Material: A615-J Anchor Rod Results Non-Rigid Strength(Fu): 100 ksi Max Rod(Cu+Vu/r)): 234.6 Kips AISC LRFD Yield(Fy): 75 ksi Allowable Axial,4*Fu*Anet: 260.0 Kips rp*rn Bolt Circle: 41 in Anchor Rod Stress Ratio: 90.2% Pass Plate Data Diam: 47 in Base Plate Results Flexural Check Non-Rigid Thick: 1.75 in Base Plate Stress: 52.4 ksi AISC LRFD Grade: 60 ksi Allowable Plate Stress: 54.0 ksi c*Fy Single-Rod B-eff: 13.84 in Base Plate Stress Ratio: 97.1% Pass Y.L.Length: 17.50 Stiffener Data(Welding at both sides) n/a Config: 0 * Stiffener Results Weld Type: Horizontal Weld: n/a Groove Depth: in** Vertical Weld: n/a Groove Angle: degrees Plate Flex+Shear,fb/Fb+(fv/Fv)^2: n/a Fillet H.Weld: <—Disregard Plate Tension+Shear,ft/Ft+(fv/Fv)^2:n/a Fillet V.Weld: in Plate Comp. (AISC Bracket): n/a Width: in Height: in Pole Results Thick: in Pole Punching Shear Check: n/a Notch: in Grade: ksi Weld str.: ksi Pole Data Diam: 34.875 in r Thick: 0.3125 in Grade: 65 ksi L #of Sides: 18 "0"IF Round Fu 80 ksi .Reinf.Fillet Weld 0 "0"if None s sa i ____________ S At 4 4 . *0=none,1=every bolt,2=every 2 bolts,3=2 per bolt **Note:for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes CCIplate 1.5-Circular Base G 1.3,Effective March 19,2012 Analysis Date: 8/22/2017