Report tY' .ZUCf'Ucscz 1-1EUEIVED t1jfEi FEB 2 0 2018 Worldwide www.t Fire Protection Contacts yco-fire.com Products CITY OF TIGARD BUILDING DIVISION Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General when exposed to corrosive atmo- spheres. Although corrosion-resistant Description coated sprinklers have passed the standard corrosion tests of the appli- The TYCO Series TY-FRB, 2.8, 4.2, cable approval agencies,the testing is , _ ry ,� 5.6,and 8.0 K-factor,Upright,Pendent, not representative of all possible cor- and Recessed Pendent Sprinklers rosive atmospheres. Consequently, described in this data sheet are quick it is recommended that the end user response, standard coverage, deco be consulted with respect to the suit- ° ,« it Ji rative 3 mm lass bulb-t p y abilit of these coatin s for an9 ype s ra y 9 y givensprinklers designed for use in tight or corrosive environment. The effects ofiambient tem erordinary hazard,commercial occupan p ature,concentration of cies such as banks, hotels, and shop- chemicals, and gas/chemical velocity, ping malls. should be considered, as a minimum, along with the corrosive nature of the The recessed version of the Series chemical to which the sprinklers will be TY-FRB Pendent Sprinkler, where exposed. applicable,is intended for use in areas An intermediate level of the Series with a finished ceiling. This recessed pendent sprinkler uses one of the TY-FRB Pendent Sprinklers is detailed following: in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- • A two-piece Style 10 (1/2 inch NPT) nical Data Sheet TFP780. f' or Style 40(3/4 inch NPT)Recessed Escutcheon with 1/2 inch (12,7 mm) NOTICE of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment The Series TY-FRB, 2.8, 4.2, 5.6, x from the flush pendent position,or a and 8.0 K-factor, Upright, Pendent, 'OR*, ` and Recessed Pendent Sprinklers • A two-piece Style 20 (1/2 inch NPT installed ' described herein must be or Style 30(3/4 inch NPT)Recessed and maintained in compliance with Escutcheon with 1/4 inch6,4 ( mm) this document and with the applica- of recessed adjustment or up to 1/2 ble standards of the National Fire Pro- inch (12,7 mm) of total adjustment tection Association, in addition to the from the flush pendent position. standards of any authorities having The adjustment provided by the jurisdiction.Failure to do so may impair Recessed Escutcheon reduces the the performance of these devices. Sprinkler accuracy to which the fixed pipe drops The owner is responsible for maintain- to the sprinklers must be cut. ing their fire protection system and Identification Corrosion resistant coatings, where devices in proper operating condition. Number (SIN) applicable,are utilized to extend the life The installing contractor or sprinkler of copper alloy sprinklers beyond that manufacturer should be contacted with which would otherwise be obtained any questions. TY1131 -Upright 2.8K, 1/2"NPT TY1231 -Pendent 2.8K, 1/2"NPT TY2131 -Upright 4.2K,1/2"NPT TY2231 -Pendent 4.2K, 1/2"NPT IMPORTANT TY3131 -Upright 5.6K,1/2"NPT Always refer to Technical Data TY3231 -Pendent 5.6K, 1/2""NPT Sheet TFP700 for the "INSTALLER TY4131 -Upright 8.0K,3/4"NPT WARNING" that provides cautions TY4231 -Pendent 8.0K,3/4"NPT with respect to handling and instal- TY4831 -Upright 8.0K, 1/2"NPT lation of sprinkler systems and com- TY4931 - Pendent 8.0K, 1/2"NPT ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 NOVEMBER 2015 TFP171 TFP171 Page 2 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7 - Bushing meltrAmit (117/116"mm) lim1 tmi 1 NOMINAL �� _ 3 .�_ `=1 MAKE-IN (57,2/mm) `� 2 �� I il ' 2-3/16" lip 1 (55,6 mm) 1-9/16" iiIj 4 \ II (39,71 mm) I P. 5 1` 1` �C f oC�� f� ` � .4'% �21e. —6* 1/2" NPT** t WRENCH STYLE 10 or 20 FLATS RECESSED 2-7/8"(73,0 mm)DIA. UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 07/16" —..= 3 (11,1 mm) 1�1'�� 1 A f! i 4 NOMINAL 2-3/16" ���� %` A 2 `=, MAKE IN i (55,6 mm) L r r Iew 1 2-3/16" 10 1-1/2" 4 (55,6 mm) 1 (38,1 mm) I \ Il 1 a IMP * 1/2" NPT** t WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. 6 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on 2 - Button Assembly Screw Deflector. special request. ESCUTCHEON PLATE SEATING 4 Bulb 6 Deflector* SURFACE 1 - 7/16" —= 3 r NOMINALmmomaimi IRr MAKE-IN 2-3/16" ���� !� 2 =� 1 (55,6 mm) �41� !iiiir �� 1 ( 5 62-3/mm) 1-1/2" I 4 (16" 038,1 mm) * 1/2"NPT** t WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. 6 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT TFP171 Page 3 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE fI"// 1� . ��p 1 1/2° J� 3 A (12,7/mm) � `�- ,� 'fi NOMINAL 1 2-6/16" kirA 2 `=, MAKE IN I (58,7 mm) `� Ai r (57,2/mm) ili 1-9/16" 1 1 4 . (39,7 mm) /=��5 3/4" NPT** t WRENCH STYLE 30 or 40 6* FLATS RECESSED -.---2-7/8"(73,0 mm)DIA. UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector fP�-�n 1 I f, 3 Assembly 7/16" '� 4 - Bulb 00 (11,1 m6" :' 2-1/4" 1.1NOMINAL 1 1 (57,2 mm) iAAiiik_ 2 — MAKE-IN 1 * Temperature rating is —1 1 4 indicated on Deflector. l2-3/16" 1-9/16" (55,6 mm) (39,7 mm) 5'L___----5 ** Pipe thread connections \ --AIL— ��� �— 6 * per ISO 7-1 can be ' provided on special 1/2" NPT** t WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT G, WRENCH � RECESS WRECESS (END"A' USED FOR eft./ RENCH 1/2" NPT MODELS) WRENCH RECESS (END"B" USED FOR %'a� 3/4" NPT MODELS) PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 6 FIGURE 7 W-TYPE 6 SPRINKLER W-TYPE 7 RECESSED WRENCH SPRINKLER WRENCH . TFP171 Page 4 of 10 Technical Design Do not attempt to compensate for insufficient adjustment in the Escutch- Data Criteria eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of Approvals The TYCO Series TY-FRB, 2.8, 4.2, the sprinkler fitting to suit. UL and C-UL Listed 5.6,and 8.0 K-factor,Upright,Pendent, Series TY-FRB Upright and Pendent FM,LPCB,and NYC Approved and Recessed Pendent Sprinklers are Sprinklers Refer to Table A and B for complete intended for fire protection systems The Series TY-FRB Pendent and approval information including corrosion- designed in accordance with the stan- Upright Sprinklers must be installed resistant status. dard installation rules recognized by in accordance with the following Maximum Working Pressure the applicable Listing or Approval instructions. Refer to Table C. agency (such as, UL Listing is based on the requirements of NFPA 13, and Step 1.Install Pendent sprinklers in the Discharge Coefficient FM Approval is based on the require- pendent position. Install upright sprin- K=2.8 gpm/psis(40,3 Ipm/barye) ments of FM's Loss Prevention Data klers in the upright position. K=4.2 gpm/psi' (60,5 Ipm/barye) Sheets). Only the Style 10, 20, 30, or Step 2. With pipe-thread sealant K=5.6 gpm/psi'2(80,6 Ipm/barY) 40 Recessed Escutcheon, as applica- applied to the pipe threads, hand- K=8.0 gpm/psiy(115,2 Ipm/barye) ble,is to be used for recessed pendent tighten the sprinkler into the sprinkler Temperature Rating installations. fitting. Refer to Table A and B. Step 3. Tighten the sprinkler into the Finishes Installation sprinkler fitting using only the W-Type Sprinkler:Refer to Table D. The TYCO Series TY-FRB,2.8,4.2,5.6, 6 Sprinkler Wrench(Figure 6).With ref- and 8.0 K-factor,Upright,Pendent,and erence to Figures 1 through 5, apply Recessed Escutcheon:Signal or Purethe W-Type 6 Sprinkler Wrench to the White,Jet Black,Chrome Plated,or Recessed Pendent Sprinklers must sprinkler wrench flats. Natural Brass be installed in accordance with this p section. Series TY-FRB Recessed Pendent Physical Characteristics Sprinklers Frame Bronze General Instructions p Button Brass/Copper Do not install any bulb-type sprinkler The Series TY-FRB Recessed Pendent Sealing Assembly..Beryllium Nickel w/TEFLON if the bulb is cracked or there is a loss Sprinklers must be installed in accor- Bulb Glass of liquid from the bulb. With the sprin- dance with the following instructions. Compression Screw Bronze kler held horizontally,a small air bubble Step A.After installing the Style 10,20,Deflector Copper/Bronze Bushing(K=2.8) Bronze should be present.The diameter of the 30, or 40 Mounting Plate, as applica- air bubble is approximately 1/16 inch ble,over the sprinkler threads and with Operation (1,6 mm)for the 135°F(57°C)and 3/32 pipe-thread sealant applied to the pipe inch(2,4 mm)for the 286°F(141°C)tem- threads,hand-tighten the sprinkler into The glass bulb contains a fluid that perature ratings. the sprinkler fitting. expands when exposed to heat.When the rated temperature is reached, the A leak-tight 1/2 inch NPT sprinkler Step B. Tighten the sprinkler into the fluid expands sufficiently to shatter the joint should be obtained by applying a sprinkler fitting using only the W-Type glass bulb, allowing the sprinkler to minimum to maximum torque of 7 to 7 Recessed Sprinkler Wrench (Figure activate and water to flow. 14 ft.-lbs. (9,5 to 19,0 Nm).A leak tight 7). With reference to Figures 1 to 4, 3/4 inch NPT sprinkler joint should be apply the W-Type 7 Recessed Sprinkler obtained with a torque of 10 to 20 ft.- Wrench to the sprinkler wrench flats. lbs. (13,4 to 26,8 Nm). Higher levels of Step C. After ceiling installation and torque can distort the sprinkler Inlet finishing, slide on the Style 10, 20, 30, with consequent leakage or impairment or 40 Closure over the Series TY-FRB of the sprinkler. Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP171 Page 5 of 10 SPRINKLER FINISH(See Note 5) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTER*** FACTOR COLOR BRASS PLATED 135°F(57°C) Orange PENDENT 155°F(68°C) Red (TY1231) and 175°F(79°C) Yellow 1,2,3,4 UPRIGHT ) (TY1131) (200°F 93°C Green 286°F(141°C) Blue 135°F(57°C) Orange 2.8 RECESSED F C 1/2" 155° 68° NPT PENDENT ( ) Red (TY1231)* 175°F(79°C) Yellow Figure 8 200°F(93°C) Green 135°F(57°C) Orange 1,2,4 RECESSED PENDENT 155°F(68°C) Red (TY1231)** 175°F(79°C) Yellow Figure 9 200°F(93°C) Green 135°F(57°C) Orange (ENDEN)T 155°F(68°C) Red and 175°F(79°C) Yellow UPRIGHT ) (TY2131) (200°F 93°C Green 286°F(141°C) Blue 135°F(57°C) Orange 4.2 RECESSED 155°F 68C 1/2" ° (68°C)PENDENT ( ) Red 1,2 (TY2231)* 175°F(79°C) Yellow Figure 10 200°F(93°C) Green 135°F(57°C) Orange RECESSED PENDENT 155°F(68°C) Red (TY2231)** 175°F(79°C) Yellow Figure 11 200°F(93°C) Green NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. *Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. "Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. ***Frame and Deflector only. N/A:Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH(See Note 8) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTER*** LEAD FACTOR COLOR BRASS PLATED COATED 135°F(57°C) Orange PENDENT (TY3231) 155°F(68°C) Red and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2,3,5 UPRIGHT 200°F(93°C) Green (TY3131) 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red 5.6PENDENT 175°F(79°C) Yellow 1,2,4,5 N/A 1/2"NPT PT (TY3231) Figure 12 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT 175°F(79°C) Yellow 1,2,3,4,5 N/A (TY3231)** Figure 13 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange PENDENT (TY4231) 155°F(68°C) Red and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2,5 UPRIGHT 200°F(93°C) Green (TY4131) 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red 8.0 PENDENT 175°F(79°C) Yellow 1,2,5 N/A 3/4"NPT (TY4231)* Figure 14 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT 175°F(79°C) Yellow 1,2,3,5 N/A (TY4231)** Figure 15 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange PENDENT (TY4931) 155°F(68°C) Red 1/28 NPT and 175°F(79°C) Yellow 1,2,4,5,6 1,2,5 UPRIGHT 200°F(93°C) Green (TY4831) 286°F(141°C) Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k104)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. *Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. **Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. ***Frame and Deflector only. N/A:Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME POLYESTER LEAD FACTOR BRASS PLATED COATED PENDENT(TY1231) and UPRIGHT(TY1131) 1/2"2.8 NPT 175 PSI(12,1 BAR) N/A RECESSED PENDENT(TY1231) PENDENT(TY2231) and 4.2 UPRIGHT(TY2131) 1/2"NPT 175 PSI(12,1 BAR) N/A RECESSED PENDENT(TY2231) PENDENT(TY3231) and 5.6 UPRIGHT(TY3131) 250 PSI(17,2 BAR) 1/2"NPT OR 175 PSI(12,1 BAR) RECESSED (SEE NOTE 1) PENDENT(TY3231) PENDENT(TY4231) 175 PSI and UPRIGHT(TY4131) (12,1 BAR) 3/48.0 NPT 175 PSI(12,1 BAR) — RECESSED N/A PENDENT(TY4231) PENDENT(TY4931) 175 PSI 1/2$NPT and 175 PSI(12,1 BAR) (12,1 BAR) UPRIGHT(TY4831) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Under- writers Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE Care and have not operated,should be replaced Care must be exercised to avoid if they cannot be completely cleaned damage to the sprinklers -before, Maintenance by wiping the sprinkler with a cloth or during, and after installation. Sprin- by brushing it with a soft bristle brush. klers damaged by dropping, striking, The TYCO Series TY-FRB must be Care must be exercised to avoid wrench twist/slippage,or the like,must maintained and serviced in accordance damage to the sprinklers before, be replaced. Also, replace any sprin- with this section. during, and after installation. Sprin- kler that has a cracked bulb or that has Before closing a fire protection system klers damaged by dropping, striking, lost liquid from its bulb. (Ref. Installa- main control valve for maintenance wrench twist/slippage,or the like,must tion Section). work on the fire protection system be replaced. Also, replace any sprin- Initial and frequent visual inspections of that it controls, obtain permission to kler that has a cracked bulb or that has random samples are recommended for shut down the affected fire protection lost liquid from its bulb. (Ref. Installa- corrosion-resistant sprinklers to verify systems from the proper authorities tion Section.) the integrity of the corrosion resistant and notify all personnel who may be The owner is responsible for the material of construction. Thereafter, affected by this action. inspection,testing,and maintenance of annual inspections per NFPA 25 should Absence of the outer piece of an their fire protection system and devices suffice. escutcheon, which is used to cover in compliance with this document, as Inspections of corrosion-resistant a clearance hole, can delay sprinkler well as with the applicable standards sprinklers are recommended at close operation in a fire situation. of the National Fire Protection Asso- range, instead of from the floor level ciation (e.g., NFPA 25), in addition to per NFPA. Inspection at close range Sprinklers which are found to be the standards of any other authorities can better determine the exact sprin- leaking or exhibiting visible signs of having jurisdiction.Contact the install- kler condition and the long-term integ- corrosion must be replaced. ing contractor or sprinkler manufac- rity of the corrosion-resistant material, Automatic sprinklers must never be turer regarding any questions. which can be affected by the corrosive painted, plated, coated, or other- Automatic sprinkler systems are rec- conditions present. wise altered after leaving the factory. ommended to be inspected, tested, Modified sprinklers must be replaced. and maintained by a qualified Inspec- Sprinklers that have been exposed to tion Service in accordance with local corrosive products of combustion, but requirements and/or national codes. TFP171 Page 8 of 10 2-7/8"DIA. - 2-7/8" DIA. (73,0 mm) (73,0 mm) 5/8±1/4" 3/4'(19,1 mm) 1/2±1/8" 1/2"(12,7 mm) (15,9±6,4 mm) 1/4 1/4"(6,4 mm) (12,7±3,2 mm) " 2-1/4" DIA. 2-1/4' DIA. .-- (6,4mm) / FACE OF (57,2 mm) 1 / FACE OF (57,2 mm) SPRINKLER MOUNTING MOUNTING PLATE SPRINKLER PLATE 1/8" . 77-- FITTING7FITTING (3,2 mm) (3,2 mm) j -II— zat ��, f U �J� SURFACEO ��� MOUNTING SURFACE ii•i.�� ivf•N� CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4'(19,1 mm) (73,0 mm) 1/2"(12,7 1/2±1/8" mm) (15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 1/4" 2-1/4" DIA. 2-1/4" DIA. (6,4mm) / FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / 1/8" (3,2 mm) / 1/8" r---- (3,2 mm)m) i t2�i _l - T G _ r =T r \ , J10 f t MOUNTING „ MOUNTING �. i SURFACE ■ SURFACE ._ _. ._ _. CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 4.2 K-FACTOR, 1/2 INCH NPT TFP171 Page 9 of 10 2-7/8" DIA. 2-7/8" DIA. _ (73,0 mm) --.----3/4"(19,1 mm) (73,0 mm) 1/2" (12,7 mm) 5/811/4" 1/211/8" (15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 2 1/4" DIA. 1/4"(6,4 mm) 2-1/4" DIA. / FACE OF (57,2 mm) 1 MOUNTING / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER7------- PLATE FITTING FITTING / (3,2 mm) / (3,2 mm) =�1_1� /zaL 1_J Pr iat f \ , , MOUNTING lip I .MOUNTING SURFACE SURFACE -�����-- . �� �_%-" ' SERIES 1-1/4"(31,8 mm) SERIES 1-1/4" (31,8 mm) CLOSURE CLOSURE TY-FRB TY FRB 1"(25,4 3/4"(19,1 mm) mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) ' 1/2"(12,7 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) (15,9±6,4 mm) 2 1/4" DIA. r 57,2 mm / FACE OF (57,2 mm) MOUNTING FACE OF ( ) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / 1/8" 1/8" (3,2 mm) / (3,2 mm) .r �ri777�i. zt I \ MOUNTING II� MOUNTING '�• SURFACE T SURFACE � • r CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 14 FIGURE 15 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT 8.0 K-FACTOR,3/4 INCH NPT TFP171 Page 10 of 10 P/N 57 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 330 2.8K UPRIGHT(1/2"NPT) TY1131 1 NATURAL BRASS 135 135°F(57°C) 331 2.8K PENDENT(1/2"NPT) TY1231 3 PURE WHITE 1 155 155°F(68°C) POLYESTER(RAL9010) 340 4.2K UPRIGHT(1/2"NPT) TY2131 4 SIGNAL WHITE 175 175°F(79°C) POLYESTER(RAL9003) 341 4.2K PENDENT(1/2"NPT) TY2231 5 JET BLACK2 200 200°F(93°C) POLYESTER(RAL9005)2 5.6K UPRIGHT(1/2"NPT) TY3131 7 LEAD COATED 286 286°F(141°C) 371 5.6K PENDENT(1/2"NPT) TY3231 9 CHROME PLATED 390 8.0K UPRIGHT(3/4"NPT) TY4131 NOTES: 1. Eastern Hemisphere sales only. 391 8.0K PENDENT(3/4"NPT) TY4231 2. Available in only 2.8K,4.2K,and 8.0K,155°F(68°C) and 200°F(93°C);requires lead time to manufacture. 360 8.0K UPRIGHT(1/2"NPT) TY4831" 361 8.0K PENDENT(1/2"NPT) TY4931" TABLE D SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for www.tyco-fire.com. availability. When placing an order, indicate the full product name and Part Number(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright)Sprinkler(specify)temperature rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify") finish, P/N(specify") Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Refer to Technical Data Sheet TFP770 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2015 Tyco Fire Products,LP. All rights reserved. VICO TEFLON is trademark of The DuPont Corporation. Fire Protection Products