Report (137) r.V1:14)-C)S rCOM check Software Version 4.0.5.3 OFFICE COPY Interior Lighting Compliance irlirill' Certificate Section 1: Project Information Energy Code:2014 Oregon Energy Efficiency Specialty Code ��C! 2 Ur Project Title: Durham Education Center > j f t Project Type: New Construction t` ' < Construction Site: Owner/Agent: Designer/Contractor: 8040 SW Durham Rd Tigard-Tualatin School District Evan Stewart Portland,OR 97224 Glumac 900 SW 5th Ave Suite 1600 Portland,OR 97204 503-345-6356 estewart@glumac.com Section 2: Interior Lighting and Power Calculation A B C D Floor Area Allowed Allowed Watts Watts/ft2 1st and 2nd floors(School/University) 19713 1.01 19910 Total Allowed Watts= 19910 Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1st and 2nd floors(School/University 19713 sq.ft) X1:X1:BACK MOUNT LED EXIT SIGN:LED MR 3.2W: 1 16 4 X2:X2:EXIT SIGN CEILING MOUNT BACK LI:LED MR 3.2W: 15 5 1 3 5 1 FA1:FA1:LED STRIPLIGHT:LED Linear 33W: F131:FB1:LED CYLDINER DOWNLIGHT:LED A Lamp 25W: 1 27 33 891 FC1:FC1:LED LINEAR STRIPLIGHT SURFACE:LED Linear 33W: 1 34 23 782 1 1 44 44 FC2:FC2:LED LINEAR STRIPLIGHT SURFACE M:LED Linear 33W: 1 1 HA1:HA1:SUSPENDED LED LINEAR LUMINAIRE:LED Panel 110W: 1 3 15 460 60 1 HA2:HA2:SHORTER HA1:LED Panel 110W: 4 1 9 HA3:HA3:SHORTER HA1:LED Panel 110W: 69 207 HA4:HA4:SHORTER HA1:LED Panel 110W: 1 14 46 644 HB1:HB1:DECORATIVE LED PENDANT:LED A Lamp 25W: 1 14 23 322 HC1:HCl:PENDANT HUNG LED LUMINAIRE:LED A Lamp 25W: 1 3 87 26113 27 486 HC2:HC2:SAME AS HC1,BUT SMALLER:LED A Lamp 25W: HC3:HC3:SAME AS HCl,BUT EVEN SMALLER:LED A Lamp25W: 1 3 40 120 1 3 24 72 HC4:HC4:SAME AS HC1,BUT LARGER:LED A Lamp 25W: 1 1 64 64 HD1:HD1:HIGH BAY LED LUMINAIRE:LED PAR 17W: 1 12 17 204 RA1:RA1:RECESSED 2'x4'LED LUMINAIRE:LED Panel 44W: 1 2 49 98 RB1:RB1:RECESSED 7"x4"LED DOWNLIGHT LU:LED Panel 19W: SE1:SE1:SURFACE-MOUNT LED LINEAR SLOTLG:LED Linear 22W: 1 29 24 696 1 3 24 72 SE2:SE2:SAME AS SE1 BUT 2 FT SHORTER:LED Linear 17W: 1 2 16 32 UA1:UA1:LINEAR LED UNDERCABINET LUMINAI:LED Undercabinet Unit 24W: 1 WA1:WA1:WALL-MOUNT LIN.LED SLOTLTG, 10:LED Other Fixture Unit 80W: 1 3 70 80 WA2:WA2:SAME AS WA1,BUT 7':LED Other Fixture Unit 50W: 3 72 2 1 3 51 1533 WA3:WA3:SAME AS WA1,BUT WITH BACKBOARD:LED Other Fixture Unit 80W: 1 WA4:WA4:SAME AS WA1,EXCEPT 4':LED Other Fixture Unit 28W: 2 72 144 1 3 30 90 .................__......_.__.......... _._......_ Project Title: Durham Education Center Data filename: C:\Users\exs\Desktop\Durham-TTSD.cck Report date: 08/23/17 Page 1 of 5 22 22 100 WB1:WB1:WALL-MOUNT LED LINEAR VANITY LU:LED A Lamp 25W: 1 7 13 910 WC1:WC1:WALL-MOUNTED DECORATIVE RLM:LED Other Fixture Unit 13W: 1 WD1:WD1:SAME AS WB1,EXCEPT 48":LED A Lamp 25W: 1 11 38 4181 1 40 40 ti WE1:WE1:SURFACE-MOUNTED LED LUMINAIRE:LED Panel 40W: Total Proposed Watts= 7038 Section 4: Requirements Checklist In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met.Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Lighting Wattage: • 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Wattage: 19910 Proposed Wattage:7038 Complies:YES Mandatory Requirements: • 2. Exit signs.Internally illuminated exit signs shall not exceed 5 watts per side. Plans reference page/section: ✓ 3. Daylight zone control.All daylight zones are provided with individual controls that control the lights independent of general area lighting in the non-daylight zone.In all individual daylight zones larger than 350 sq.ft.,automatic daylight controls is provided.Automatic daylight sensing controls reduce the light output of the controlled luminaires at least 50 percent,and provide an automatic OFF control, while maintaining a uniform level of illumination.Contiguous daylight zones adjacent to vertical fenestration may be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations(i.e.,north,east, south,west).Daylight zones under skylights shall be controlled separately from daylight zones adjacent to vertical fenestration. Plans reference page/section: ✓ 4. Interior lighting controls.At least one local shutoff lighting control has been provided for every 2,000 square feet of lit floor area and each area enclosed by walls or floor-to-ceiling partitions.The required controls are located within the area served by the controls or are a remote switch that identifies the lights served and indicates their status. Plans reference page/section: ✓ 5. Sleeping unit controls.Master switch at entry to hotel/motel guest room. Plans reference page/section: ✓ 6. Egress lighting.Egress illumination is controlled by a combination of listed emergency relay and occupancy sensors to shut off during periods that the building space served by the means of egress is unoccupied. Plans reference page/section: ✓ 7. Additional controls.Each area that is required to have a manual control shall have additional controls that meet the requirements of Sections 505.2.2.1 and 505.2.2.2. Plans reference page/section: ✓ 8. Light reduction controls.Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either 1)controlling(dimming or multi-level switching)all luminaires;or 2)dual switching of alternate rows of luminaires,alternate luminaires,or alternate lamps;or 3)switching the middle lamp luminaires independently of other lamps;or 4)switching each luminaire or each lamp. Plans reference page/section: ✓ 9. Buildings larger than 2,000 square feet are equipped with an automatic control device to shut off lighting in those areas.This automatic control device shall function on either: 1)a scheduled basis,using time-of-day,with an independent program schedule that controls the interior lighting in areas that do not exceed 10,000 square feet and are not more than one floor;or 2)an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space;or 3)a signal from another control or alarm system that indicates the area is unoccupied. Plans reference page/section: ✓ 10.Occupancy sensors in rooms that include daylight zones are required to have Manual ON activation. Plans reference page/section: ✓ 11.An occupant sensor control device is installed that automatically turns lighting off within 30 minutes of all occupants leaving a space. Report date: Project Title: Durham Education Center Page 2 08/23/17 5 Data filename: C:\Users\exs\Desktop\Durham-TTSD.cck Plans reference page/section: `/ 12.Additional controls.An occupant sensor control device that automatically turns lighting off within 30 minutes of all occupants leaving a space or a locally activated switch that automatically turns lighting off within 30 minutes of being activated is installed in all storage and supply rooms up to 1000 square feet. Plans reference page/section: 13.Occupant override.Automatic lighting shutoff operating on a time-of-day scheduled basis incorporates an override switching device that: 1)is readily accessible,2)is located so that a person using the device can see the lights or the area controlled by that switch,or so that the area being lit is annunciated,3)is manually operated,4)allows the lighting to remain on for no more than 2 hours when an override is initiated,and 5)controls an area not exceeding 2,000 square feet. Plans reference page/section: 6/ 14.Holiday scheduling.Automatic lighting shutoff operating on a time-of-day scheduled basis has an automatic holiday scheduling feature that turns off all loads for at least 24 hours,then resumes the normally scheduled operation. Plans reference page/section: v 15.Exterior lighting controls.Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination of a photosensor and a time switch,or an astronomical time switch.Lighting designated for dusk-to-dawn operation shall be controlled by an astronomical time switch or photosensor. Plans reference page/section: v 16.Tandem wiring.The following luminaires located within the same area shall be tandem wired: 1.Fluorescent luminaires equipped with one,three or odd-numbered lamp configurations,that are recess-mounted within 10 feet center-to-center of each other. 2.Fluorescent luminaires equipped with one,three or any odd-numbered lamp configuration,that are pendant-or surface-mounted within 1 foot edge-to-edge of each other. Plans reference page/section: v 17.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. Plans reference page/section: v 18.Each dwelling unit in a building is metered separately. Plans reference page/section: Interior Lighting'PASSES:Design %better than Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2014 Oregon Energy Efficiency Specialty Code requirements in COMcheck Version 4.0.5.3 and to comply with the mandatory requirements in the Requirements Checklist. Name-Title Signature Date ............................... Project Title: Durham Education Center Data filename:C:\Users\exs\Desktop\Durham-TTSD.cck Report date: 08/23/17 Page 3 of 5 COMcheck Software Version 4.0.5.3 11111111 ' Exterior Lighting Compliance Certificate Section 1: Project Information Energy Code:2014 Oregon Energy Efficiency Specialty Code Project Title: Durham Education Center Project Type: New Construction Exterior Lighting Zone: 2(Residential mixed use area) Construction Site: Owner/Agent: Designer/Contractor: 8040 SW Durham Rd Tigard-Tualatin School District Evan Stewart Portland,OR 97224 Glumac 900 SW 5th Ave Suite 1600 Portland,OR 97204 503-345-6356 estewart@glumac.com Section 2: Exterior Lighting Area/Surface Power Calculation A B C D E F Exterior Area/Surface Quantity Allowed Tradable Allowed Proposed Watts Wattage Watts Watts /Unit (B x C) Covered Play Area(Plaza area) 1621 ft2 0.14 Yes 227 216 NW Courtyard(Plaza area) 1537 ft2 0.14 Yes 215 22 NE Parking Lot(Parking area) 21763 ft2 0.06 Yes 1306 414 Exterior sidewalk(Illuminated length of facade 505 ft 2.5 No 1263 870 wall/surface or roof path) Total Tradable Watts"= 1748 652 Total Allowed Watts= 3010 *Wattage tradeoffs are only allowed between tradable areas/surfaces.Total Allowed Supplemental Watts**= 600 **A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Section 3: Exterior Lighting Fixture Schedule A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Covered Play Area(Plaza area 1621 ft2):Tradable Wattage SA1:SA1:SURFACE MOUNTED LED LUMINAIRE:LED A Lamp 25W: 1 8 27 216 NW Courtyard(Plaza area 1537 ft2):Tradable Wattage SF1:SF1:SURFACE-MOUNT LED STEPLIGHT:LED MR 2W: 1 11 2 NE Parking Lot(Parking area 21763 ft2).Tradable Wattage 22 SD1:SD1:POLE-MOUNT LED PARKING LUMINAIR:LED Roadway-Parking Unit 1 6 69 414 67W: Exterior sidewalk(Illuminated length of facade wall/surface or roof path 505 ft):Non-tradable Wattage SC1:SC1:SINGLE-HEAD LED PEDESTRIAN LIGH:LED Roadway-Parking Unit 1 10 87 870 82W: Total Tradable Proposed Watts= 652 Section 4: Requirements Checklist In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Project Title: Durham Education Center _®.. 17 Data filename: C:\Users\exs\Desktop\Durham-TTSD.cck Report date: 08/23/17 Page 4 of 5 Controls, Switching,and Wiring: ✓ 1. Lighting designated to operate more than 2000 hours per year for Uncovered Parking Areas shall be equipped with motion sensors that will reduce the luminaire power by thirty-three percent or turn off one-third the luminaires when no activity is detected. Plans reference page/section: Exterior Lighting Restrictions and Exceptions: • ✓ 2. Mercury vapor and incandescent lighting is not permitted for use as exterior lighting. ✓ 3. Exempt lighting fixtures are equipped with a control device independent of the control of the nonexempt lighting and are identified in Section 3 table above. Plans reference page/section: Section 5: Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2014 Oregon Energy Efficiency Specialty Code requirements in COMcheck Version 4.0.5.3 and to comply with the mandatory requirements in the Requirements Checklist. Name-Title Signature Date Report date: 08/23/17 Project Title: Durham Education Center Page 5 of 7 Data filename: C:\Users\exs\Desktop\Durham-TTSD.cck