Loading...
Plans (58) HERMAN PS ENGINEERING /\ -- 3151 NESANDY BoV,,SUFI" 100 \ INCPcm1� _ av .OD8723% / \ ~� Paoms (S03) %3O'88I6 Con M���������l�l�l0�� ^'��~^'�~^~~^~�~��v�^"u To: Richard L. White The White House Collection 13817 SW Benchview Terrace Tigard, Oregon 97223 Date: January 30, 20187 7 Fro m: StigVV}deU, PE Associate «V\�'' EXPIRES: 6-30— ��E: Sherman Engineering Project:#P17-0Q63 — Smart Residence lZO755VVRose Vista Dr �-- Tigard, OR 97223 This memo is in response to the inspection report by David Young ofthe [itvof Tigard. VVehave revievxedthe |ocahonand details for the Lida box aYthe front nfthe above referenced pject. The attachment of the planter to the standard wall construction shown in detail A2 is acceptable. If you have any questions please give us a call. File K4em0'0l3O18'Smart Residence.doC CooP l,17„,„ Engineering,Inc. Real-World Geotechnical Solutions February 13, 2018 Investigation• Design • Construction Support Project No. 18-4849 Rafe Veenker The Hollman Company 3011 SW Riverfront Terrace Wilsonville, OR 97070 phone503-701-3265 Email rafeOhollmanco.corn FOUNDATION SUBGRADE REVIEW 12075 SW ROSE VISTA DRIVE TIGARD, OREGON GeoPacific Engineering Inc. visited the site yesterday and last week to review the single family home foundation subgrade at the above address. We understand that the proposed building is a two-story home. In our opinion, the observed subgrade is adequate for support to an allowable bearing pressure of 1,500 psf. At the time of our site visit, the excavation was complete and soils exposed in foundation excavation consisted of predominantly stiff native silt soils that could be probed about 3 to 6 inches with moderate pressure using a steel "T" bar probe. The expected maximum anticipated total and differential footing movements (generally from soil expansion and/or settlement) are 1 inch and 3/ inch, respectively, over a span of 20 feet. It should be noted that the on-site soils are very moisture sensitive and will soften significantly in wet weather conditions if not adequately protected. Also some structural backfilling of vertical steps is anticipated to laterally support the exposed cuts. Due to relatively impervious silty and clayey soils encountered throughout the site, all foundations should incorporate appropriate drainage measures in accordance with the International Residential Code. Adequate crawlspace drainage is not something that geotechnical consultants can verify; the purpose of our visit is for observations of foundation bearing conditions only. Our work scope pertains to a geotechnical engineer's foundation excavation review only and the conditions existing and exposed at the time of our site visit. Within the limitations of scope, schedule and budget, GeoPacific attempted to execute these services in accordance with generally accepted professional principles and practices in the fields of geotechnical engineering and engineering geology at the time the report was prepared. No warranty, express or implied, is made. If you have any questions, please call. 14835 SW 72nd Avenue Portland, Oregon 97224 Tel(503)598-8445 Fax (503)941-9281 f GeoPacific Engineering, Inc. Job No. 18-4849 12075 SW Rose Vista Drive Sincerely, GeoPacific Engineering, Inc. oF 14743P / pf V OREGON (4/44. 3 EXPIRES:061301210 James D. Imbrie, G.E. Geotechnical Engineer If q S 002r00' 10244• 1 $ " i \vt- ,, in Vii, o 91,-j5.00'__ 4 V 978 Nit M 1i, 23.00 s 59 A. Q= 66 ".'6 .c 16.5' — N N w o Y o g « Qs,'W' iI! i Y 16.5'— -•- : 31.6' - -I � o-1 �,' � '� �+'� Lyi_] 8 8 di '� '"c n1 .o==tr ' V) .(2. Z. N SSS O a s • O15.33' 2 `. 27,4' — 4 -4-.4.-1.0' F i' S $ ii ' [Z 17.�� p v J. J. JL 0~ O9 4 j: .706 y4,, Iv s oo2roo" $, ( 11asa' 09°5fw n m I L N z 'Z r— m inA Z13 v UJ. iF O U N oa 2r II- 0 ` V ,0 CLIENT: HOLCMANCO. STAKEOUT AdORIG.DATE: 1/18/18 a7 /1 G V/ DRAWN BY: BB LOT2, COLONIAL VIEW CENTERLINE CONCEPTS SHEET No, 1 OF 1 WASHINGTON COUNTY,OREGON LAND SURVEYING,INC. 19376 5$Q,ol A A9E.,5151[120 OREGON an',MOON 97045 `` SCALE:f"=20' Floe romoo.0tee rAx 003,000.0159, Rolla 2/Y3/2018-a t 5pin,1F.\PRO,v7$\H L4GN CO-ROSE 90TH Th-O_tz 7 ONISrAKEVUre,r9,1.5,45 Loywtl