Report (77) :711n STREET TREE
TIGARD CER TIFICA TION
I, S4-e t,e , owner/agent for L. 2. 140( -,,� ,
(PLEASE PRI (PERMIT HOLDER)
do hereby cert that the following location meets
City of Tigard land use and development standards
for street tree installation and is consistent
with the approved site plan.
PERMIT NO.: — DO 'S
HIE ADDRESS: Fy6 37 S(,J S cjc ,; — — Y
SUBDIVISION• ,el., , , mac,' LOT#:
i
SIGNATURE: wipDATE: g 2ot�
9 (OWNER/AGENT)
RECEIVED &
VERIFIED BY 777. DATE: SC—
(CITY OF TIGARD)
❑ Tree location verified per approved site plan.
I:\Building\Forms\StreetTreeCertificate 05/30/2012
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: ,,�^ f 7-z6, , 0
6 � Jurisdiction: /�
Site Address:�l�/l J 9 GY
Subdivision/Lot
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, ora lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N 1107.2)1
Signature: ���L/ Date: r71� yam, j�I7
O '" e : al Co� for/Authorized Agent T /
Print Name: ` � Mc+
1 ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
IABuilding\Forms\RES-HighEfficiencyLighting.doc 07/01/08
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, 3-kJ Llx.r0A.41 , am the general contractor or the owner-builder
at the following address:
Site Address: 86 37 Sc .,,du_ C
City:
( /3&Dee,
Permit#:
M4S7-20l6 ^ no -nS
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: •� �i�,
,tL/ Date: g 8 l 407
one.ctor 'r Owner-Builder
I:\Building\Form\RES-MoistureSensitiveWood.doc 09/25/08
Form 640S 2017
Completion Certification—Site Inspection y
New Homes Program—Single Family
of
To be completed by Verifier Oregon
CLEAResur is a Program Management Contractor for Energy Trust of Oregon,Inc.
Payment Information
Incentive Payee Company Name: (Performance Insulation and Energy IIs this payment redirected?: (Yes
Builder or Company: D.R.Horton Redirect to Name:
Verifier Payee Company Name: Performance Insulation and Energy Redirect Payee Com Performance Insulation and Energy
Affordable Housing No
Solar Ready Builder Incentive: No ISolar ReadyVerifier Mork()
Site Infonhation
Development Heritage Crossing (Lot 19 *• Axis ID: I (REM/Rate®ID:
Address: j!$yys NNIeitp 1
Street Line 2 Multi-Family No City: Tigard State: OR Zip: 97224
Total conditioned area(sq.ft.): 2,757 House Volume: 1 24,564 Housing Type: Detached single family
Number of Stories: I2 Number of Bedrooms: 5 Foundation Type: Crawlspace
Electric Provider: Portland General Electric Gas Provider: NW Natural Gas
Solar installed Solar Installer Name/Company:
Blue shaded fields are required for EPS sheet
Verification Typo Actual Model Equipment Details&Notes
Slab Perimeter Insulation R- 0.0 Slab Under Insulation R-
Insulation Framed Floor R- 30.0 Secondary Framed Floor R- 30.0
Above Grade Wall Insulation R- 21.0 Below Grade Wall Insulation R.
Flat Ceiling Insulation R- 38.0 Vaulted Ceiling Insulation R-
Windows Windows U- 0.3 SHGC:10.3 Total window area: 1337
Cooling Air Conditioning SEER: Model#:
Primary Heating System Details AFUE: 92.1 Brand Bryant
Type: Gas Furnace HSPF: Model#: 9125C48060017*
Heating Fuel: Gas SEER:
Primary Heat
Source Comment: COP:
Location: Attic Outdoor Unit(for heat pumps)
ECM: No Model#: I
AHRI Certificate:7126231 #of Systems 11
Gallons: 180 Brand: AOSmith
Water Heater Type Storage EF: 12.9 Model#: HPTU-66N 120
Water Heating Fuel Electric Location:'Garage or ope AHRI Certificate:7551746
Duets and Duct Location 'Partial %ducts inside: 1' ,/.Duct Leakage(CFM) 50Pa: 166 ', ����•
Testing
Infiltration Air Changes per Hour(ACH) 50Pa: 2.5
Ventilation Ventilation Type HRV/ERV Model:
Supply Side-Air Cycler Airflow measured or why untestable? (Roof Termination
Appliances
Refrigerator kWh/yr Model:
ENERGY STAR Diswasher kWh/yr Model:
Percent High Efficacy Interior Lighting(%) 100% Thermostat
Showerhead 1.5 GPH 1 Showerwand 1.5 GPH 1 Showerhead 1.6 GPH 1 IShowerhead 1.75 GPH I
Notes: