Report (69) Bend Office (541)330-9155 Geotechnical Office (503)601-8250 'C iris on Testing, Inc• Eugene Office (541)345-0289 Salem Office (503)589-1252 Tigard Office (503)684-3460 Special Inspection FINAL SUMMARY LETTER Date: February 12, 2018 Job#: T1701603 RECEIVED City of Tigard FEB 1 2Qj$ 13125 SW Hall Blvd Tigard, OR 97223-8199 CITY OF TIGAiD 3UILDING DIVISION Attn: Building Division Re: Project Name: Skyhook Ninja Fitness—Interior Alteration Address: 12008 SW Garden Place—Tigard, OR Permit#: BUP2016-00350 Per Chapter 17, Section 1704.1.2 of the International Building Code (IBC), we have performed special inspection of the following item(s) per our inspection reports only: Expansion Anchors The non-compliance (NC) items recorded for each of the above inspection categories, as listed on the non-compliance report, have been either repaired and re-inspected by CTI for compliance or reviewed and accepted by the engineer of record for the project in the"As-Built Condition" or through an RFI. The issuance of this final report is based on the engineer's acceptance of the NC items not specifically re-inspected by ion of those items CTI. CTI did not of these individual ittems on the non-compliaional review or nce list. The engineer of beyond has provided the ections that generated e of the non-compliance items and as-built conditions. All requested inspections and tests were performed and reported according to the requirements of project documents and to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship, provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our construction inspection and testing services were provided and intended to help reduce the risk of construction defects, deficiencies or omissions that arose during and after construction. Our services do not constitute a warranty or guarantee of any type. Even with diligent construction monitoring and testing, construction defects, deficiencies or omissions in the contractor's work may exist. It is the contractor's responsibility to perform their work in accordance with the approved construction documents. CTI has provided its professional services with the degree of care and skill currently exercised under similar circumstances by members of its profession in the same locale. Statements made in our reports are based on technical judgments and should not be construed to be conclusive representations of fact. Our reports pertain to the material tested/inspected only. Updated 11/30/11 P:\Projects\General\2017\T1701603\02-12-18 Final Letter.doc Date: ,. February 12, 2018 Job#: T1701603 Page 2 of 2 CTI's services did not include responsibilities related to determining, supervising, implementing or controlling the means, methods, techniques, sequences or procedures of the construction or evaluating or reporting job conditions related to health, safety or welfare. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are further questions regarding this matter please do not hesitate to contact this office. Respectfully submitted, CARLSO► -STING I . E--Ka -n Shepherd Project Manager KS/jng cc: Cody Knope-Jenkins BIYARO@GMAIL.COM City of Tigard Building Division—Walter`Chip' Barnett WALTER@TIGARD-OR.GOV Koble Creative—Terry Amundson TERRY@KOBLECREATIVE.COM Carlson Testing, Inc. Incompleted Items List (NCL) Feb 12,2018 T1701603. Project Name: SKYHOOK NINJA FITNESS - INTERIOR ALTERATION Project Address: 12008 SW GARDEN PLACE TIGARD OR Permit No: BUP2016-00350 P.O.No: Project Manager: K. SHEPHERD Item# Insp. Date Item Description Compliance CTI Sign-Off Date Corrected 1 GP 04/04/2017 SUBMITTAL 5/A2.3 CALLS FOR 3/8" X 3" TITEN HD ACCEPTABLE PER ENGINEER STEVEN W. LEACH 02/12/2018 ANCHORS WITH 2 %" EMBEDMENT. INSTALLERS USED %" X OF RECORD LETTER DATED 5-%Z" ITW RED HEAD WEDGE ANCHORS. 07/14/17 AND LOAD TESTING PERFORMED BY CTI REPRESENTATIVE ON 08/17/17. 2 GP 04/04/2017 PORTION OF ANCHORS PROTRUDING FROM TOP OF ACCEPTABLE PER ENGINEER STEVEN W. LEACH 02/12/2018 CONCRETE RANGES FROM 1-%" TO 2-%" . TOPS OF SOME OF RECORD LETTER DATED ANCHORS HAVE BEEN CUT OFF. NO WAY TO VERIFY EMBED 07/14/17 AND LOAD DEPTH. TESTING PERFORMED BY CTI REPRESENTATIVE ON 08/17/17. CC:CODY KNOPE-JENKINS CITY OF TIGARD BUILDING DIVISION - WALTER 'CHIP' BARNETT KOBLE CREATIVE - TERRY AMUNDSON Page: 1 �I I11203 QW D Y Structural • Civil Engineers July 14, 2017 Skyhook Ninja Fitness 12008 SW Garden Place Tigard, OR 97223 Attn: Cody Knope-Jenkins Re: Trampoline Anchor Testing Recommendations 12008 SW Garden Place,Tigard, OR Dear Cody, At your request, WDY has prepared the following recommendations for testing the trampoline concrete anchors at the subject site. We understand that anchors were installed without special inspection and some anchors did not achieve full embedment. Our recommendations are based on 1.5 times the cracked concrete design capacity of the 3/8" diameter x 3" Titen HD anchors noted on the project drawings, assuming a minimum 5" concrete slab on grade with a minimum 2,500 psi 28 day concrete compressive strength (modified to allowable strength levels). Anchor testing shall be performed by an independent testing agency retained by you or your company. Testing Recommendations: Tension test load: 1,250 pounds. Acceptance criteria—anchor maintains test load for 1 minute. 1. Test all anchors that have had the top of the anchor cut off or anchor length above the slab that would indicate incomplete embedment. 2. Test 10% of remaining anchors. Notify engineer after first failed anchor in this group and load at failure before continuing. 3. If any of the 10%fail—test an additional 10%. 4. If any of the second 10%fail—test all remaining anchors. 5. Prepare a report of findings, including identifying anchors tested, anchors that fail the test (if any) and load at failure. Limitations: WDY has not analyzed the trampoline system. The recommendations contained herein are based solely on the capacity of the anchors specified on the project drawings dated Rev no. 1, 02.10.2017. WDY is not responsible for the design of the trampoline system or trampoline anchorage. Please contract our office if you have any questions or if we can be of any further assistance. WDY, INC. Dale DiLoreto, P.E., S.E. Cell: (503)970-1039 cc: Koble Creative—Attn:Terry Amundson \\WDY-DC011Projects\2017\17156 Skyhook NinjalDocument\17156 Testing Memo.doc 6443 SW Beaverton-Hillsdale Hwy,suite 210•Portland,OR 97221 •ph:503.203.8111 •fx:503.203.8122•www.wdyi.com