FIRE ALARM TABLE OF CONTENTS
Centene
13221 SW 68th Parkway Suite 500
Tigard, OR 97223
Drawing
Silent Knight - 5495
Booster Panel
Wheelock - HSW
Horn/Strobe, Wall, White
Wheelock - STW
Strobe, Wall, White
Wheelock - HSWC
Horn/Strobe, Ceiling, White
FIRE SYSTEM ACCESSORY
•
SILENT Model 5495
KNIGHT Distributed Power Module
In an emergency,
by Honeywell you need maximum power
The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply
available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for
appliances from System Sensor®,Gentex®,AMSECO®, Wheelock and Faraday—what you need to drive power-
hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years
ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive
linear mode power supplies.And,ADA retrofits are easier and less expensive with the 5495 because it
integrates into current systems without the costly investment in new components.
For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent
Knight today for more information at 1-800-328-0103.
Model 5495 to non-essential high-current
Distributed Power Module accessories like magnetic door
The 5495 is a 6 amp notification power holders
expander that provides its own AC Built-in synchronization for
power connection, battery charging appliances from System
Sensocircuit,and backup battery for use with Wheel®,Centex®,AMSECO®,
fire and security controls such as the Wheelock and Faraday
Silent Knight Model 5208 Fire Control • Stand alone operation
/Communicator.The 5495 is the cost- • Lightweight design adds to ease of
effective solution for powering installation and reduces shipping
notification appliances required by the costs
Americans with Disabilities Act(ADA).
The 5495 has built-in ANSI cadence Operates with most polarized, UL
pattern,which can upgrade older Listed notification devices
control panels that lack cadence • ANSI Cadence pattern output
capability. capability built-in
Features Connection to Local Fire Control
• UL Listed for 6 amps of notification The 5495 may be connected to a local
power fire control which utilizes Class A or Model 5495
• Power supply's advanced switch Class B type notification circuits Distributed Power Module
operating between 9 and 32 VDC.The
mode design reduces damaging control panel's notification circuit is Approvals
heat and manages power up to 50% connected to one of the inputs on the • UL Listed
more efficiently than other systems 5495.The control panel's notification
• Dip switches allow for easyMEA 429-92-E Vol XII
circuit end-of-line resistor is also • CSFM 7300-0559:123
reconfiguration connected across two terminals on the
• 24 VDC filtered output voltage 5495,which provides supervision •
NFPA 72
• Four power-limited notification between the 5495 and the fire control • OSHPD(CA)OSP-0065-10
outputs;2 Class A or 4 Class B,or 1 panel. Polarized audible and/or visual (see accessories)
Class A and 2 Class B notification devices are then connected
• Additional continuous auxiliary to the 5495 signal circuits using the
output 4.71(0 end-of-line resistors provided.
Since the 5495 draws very little power
• 3 amps per output circuit from the control, it is possible to
• 2 inputs;2 Class B or 2 Class A connect one 5495 to each notification
• Ground fault detector/indicator circuit on the control panel and still
• Independent trouble relay provide full supervision of the
• AC loss delay option shuts off power notification circuits all the way back to
the control panel.
FIRE SYSTEM ACCESSORY
r
Model 5495
- Distributed Power Module
Model 5495 Block Diagram
Signal Circuit Output Signal 1 Signal 1
Input
SignalDistributed Signal 2
Signal Circuit Output2 Power
Input Module 5495 Signal 3
(Optional)
Signal 4
120 VAC
I Aux. Power
Trouble Output
Local Fire Control (Alternative to notification
circuit trouble.)
- Supervision Current: Input
The 5495 supervises a variety of Standby 75 mA voltage range: 9-32 VDC
functions including: Alarm 205 mA Battery charging
• Low AC power Auxiliary capacity: 35.0 AH
• Low battery condition power circuit: 1 Ambient temp.: 32°to 120° F
• Earth ground fault °
Notification (0°to 49° C)
• Auxiliary output power limit circuits: 4 Mechanical
condition
• EOL supervision trouble or Output Dimensions: 12.25"W x 16" H x
power limited condition at an configuration: 2 Class A(Style Z) 3"D (30.88 cm W
output 4 Class B (Style Y) x 40.64 cm H x
(1 Class A& 7.62 D cm)
When a trouble condition occurs, 2 Class B)
the 5495 creates a trouble Indicator Lights
condition on the host control signal Amps per AC power on : Green
circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow
5495 still maintains the ability to be Notification Ground fault: Yellow
activated by the host control. In circuit output: 20.4 to 27.3 VDC
addition, the 5495 provides a Form @ 3.0 amps each, Aux trouble: Yellow
C trouble relay output as an 4.7 k.Q EOL Output troubles (1-4): Yellow
alternative to using the notification resistor required Ordering Information
circuit trouble. on each Class B
circuit 5495 Distributed Power Module
Electrical Specification Accessories:
AC input: 120 VAC at 2 amps No. of inputs 2
Input
Output: 24 VDC at 6 amps SK-SCK Seismic Compliance Kit
configuration: 2 Class B or 2
Class A
SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA
CS
KNIGHT ep product information uapte- ate and accurate.We cannot cover all
specifickeour applications or anticipate all requirements.All specifications are FORM#350395 Rev F
e subject to change without notice.For more information,contact Silent Knight
by Honeywell 12 Clintonville Road,Northford,CT 06472-7161 Phone:(800)328-0103, O 2013 Honeywell International Inc.
Fax:(203)484-7118.For Technical Support,please call 800-446-6444.
www.silentknight.com
Wheelock ExcederTM Series
s
Melt Notification
ED Strobe, Horn Strobe, and Horn
Notification Appliances
4
fyr. !,,:,t,.• � ,, ,_:::, ,r
,,,iiik,
. .
_ ---;rN,..
t
Description:
The Wheelock®ExcederTm Series of notification appliances feature
a sleek modern design that will please building owners with reduced
total cost of ownership. Installers will benefit from its comprehensive ,
feature list, including the most candela options in one appliance,
low current draw,no tools needed for setting changes,voltage test
points, 12/24 VDC operation,universal mounting base and multiple )'
mounting options for both new and retrofit construction. s
The Wheelock®ExcederTM Series incorporates high reliabilityand : rz
high efficiency optics to minimize current raw allowing for a greater4111
�� �
number of appliances on the notification appliance circuit.All strobe
models feature an industry first of 8 candela settings on a single Sleek Modern Aesthetics
appliance.Models with an audible feature 3 sound settings(90,95,
99 dB).All switches to change settings,can be set without the use
of a tool and are located behind the appliance to prevent tampering. 0:14Finger Slide Switches
Wall models feature voltage test points to take readings with a
voltage meter for troubleshooting and AHJ inspection.
The Wheelock® ExcederTM Series of wall and ceiling notification Voltage Test Points
appliances feature a Universal Mounting Base (UMB) designed
to simplify the installation and testing of horns, strobes, and
combination horn strobes. The separate universal mounting 12/24 Multiple Voltages
base can be pre-wired to allow full testing of circuit wiring before VDC
the appliance is installed and the surface is finished. It comes
complete with a Contact Cover for protection against dirt,dust,paint
and damage to the contacts. The Contact Cover also acts as a , } 3 Audible Settings
shunting device to allow pre-wire testing for common wiring issues. so,95,99 dB
The Contact Cover is polarized to prevent it from being installed
incorrectly and prevents the appliance from being installed while 8 Candela Settings***
it is on the UMB. When the Contact Cover is removed the circuit Wall-15/1575/30/75/95/110/135/185
will show an open until the appliance is installed.The UMB allows Ceiling-15/30/60/75/95/115/150/177
for consistent installation and easy replacement of appliances if
required. Wall models provide an optional locking screw for extra , Universal Mounting Base ***
secure installation, while the ceiling models provide a captivated v Ceiling and Wall
screw to prevent the screw from falling during installation. Mounts to 5 sackbox Types
Environmentally Friendly
Low Current Draw
Compatibility and Requirements}
-Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol
-Compatible with UL"Regulated Voltage using filtered VDC or unfiltered VRMS input voltage
-Strobes produce 1 flash per second over the&Regulated Voltage"range
*Compared to competitive models ***Patented
**Compared to previous models
s a L_E •:: •s:"t:
Low Current Draw = Fewer Power Supplies
Strobe Ratings per UL Standard 1971
UL Max Current'"
24VDC/24FWR 12VDC
Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75
Range VDC
Jill all/ all/
an 1111111 11111 Ell ® 0.205 0.253 0.110 0.140
STC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0.253 0.110
Horn Strobe Ratings per UL 1971&Anechoic at 24 VDC
UL Max Current at Anechoic 99 dBA
24 VDC 12VDC
Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75
Range VDC
al _ 11111 11111 NIB all 0.242 0.282 0.125 0.159
0.082 _ 0.141 1111 0.176 0.197 0.242 0.282 0.125
UL Max Current at Anechoic 95 dBA
24VDC 12 VDC
Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75
Range VDC
HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230
0.272 0.122 0.153
HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122
UL Max Current`at Anechoic 90 dBA
24VDC 12 VDC
Model RegRulatedange VDC Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75
HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226
0.267 0.120 0.148
HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120
Horn Ratings per UL Anechoic
A
Model Regulated Voltage 99 dB 95 d6 90 d6
Range VDC
HN 16-33.0 0.064 0.044 0.022 k'',
HNC 16-33.0 0.084 0.044 0.022
HN 8.0-17.5 0.047 0.026 0.017
` HNC 8.0-17.5 0.047 0.026 0.017
.
* r "3r4.1naic;i 'ttaii#g ,dle stinal �1 I'' a °cg � - i ; ft '
F. ,i "na • jJs-#s, Ofkt e' 11 {t1 _ 0 ,,,,, ,--,9-..4' c,rr! , m :a. ha '4 :4'. nTfi@1ce�fmu�j bstP{iAgp . Mtr Y t } p4 at f do0 : .
,
A to t '! ✓ �)� �s
1 p t a }
Sync w/
Model Strobe
DSM or
Mounting
Candela Wheelock Power 12/24 VDC*
Supplies
Options
Horn Strobes
HSR11111 111 ,
ci, iii 15/1575/30/75/95/110/135/185 X
, gilt
X v UMB"`
MID
HSRCiii 15/30/60/75/95/115/150/177 X X
v o UMB.*
Strobes 11111 � O
i
as
v
gill
E STR v 15/1575/30/75/95/110/135/185 X X
o UMB**
Ni
MI $
STRC 15/30/60/75/95/115/150/177 X
a) STWC X 6 UMB**
0 15/30/60/75/951115/150/177 X X
w Horn UMB**
O HNR 0
HNW X X N UMB**
w HNRC X
X UMB**
HNVYC X X o UMB**
Ln
o
oo
*12 VDC models feature 15&15/75 settings
X UMB**
**UMB=Universal Mounting Base
i
J
i
, ittiti44:ti7Fli
;r
t
Wr,;:e'''''-'41! , a :.
46,
,M1,'E,,,,,, . , ,a .
,_ , . ..1Y4.. ; 1, -
V
1 {
CI) '''',.., ' ;
C i
I 3
Voltage test points for quick 8 candela settings Common base for wall and ceiling with 5
4 troubleshooting and easy spot mounting options
checking(wall models only)
a
-,,4',-4'
is r -��%�" i °3 . *4. ; -▪ .,.• '1."-.„4.70l,' 3
a,
The notification appliances shall be Wheelock"Exceder'"Series HS Audible Strobe appliances, Series ST Visual Strobe appliances
and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971(Emergency
Devices for the Hearing-Impaired)for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard
464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with
standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC.
Indoor wall models shall incorporate voltage test points for easy voltage inspection.
The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one(1)flash per second over the Regulated
Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design.
Where Multi-Candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75,30, 75, 95, 110,
135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting
the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with
75 candela on-axis is required(e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible
location at all times when installed.
The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal
(Code 3)audible outputs.
The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow
mounting to a single-gang,double-gang,4-inch square, 3.5-inch octal,4-inch octal or 100mm European type back boxes. Two wire
appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to
attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of
an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP). The mounting base shall be the same
base among all horn,strobe, horn strobe,wall and ceiling models. All notification appliances shall be backwards compatible.
The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58"W x 2.19"D. Series HN wall shall measure 5.24"
H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63"D. Series
HNC ceiling shall have a diameter of 6.68"x 1.50"D.
When synchronization is required,the appliance shall be compatible with Wheelock°'s DSM Sync Modules,Wheelock®Power Supplies
or other manufacturer's panels with built-in Wheelock®Patented Sync Protocol.The strobes shall not drift out of synchronization at any
time during operation. If the sync protocol fails to operate,the strobe shall revert to a non-synchronized flash-rate and still maintain(1)
flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced
while maintaining strobe activation when used with Wheelock®synchronization protocol.
Wall Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal(CSFM), ULC, FM
Ceiling Appliances—UL Standard 1971, UL Standard 464,California State Fire Marshal(CSFM), ULC, FM
Nang
Member
WE ENCOURAGE AND SUPPORT NICET CERTIFICATION
3 YEAR WARRANTY
Exceder- Spec Sheet 6/11
N1 LF 11-1,
�I3 uranchport Ac.
Lona Racch.N!07740
F st"� 31- 11,
F:I �-7�2-S70I
c,, ,t1,[1(_
CooperNotificationis Wheelock° SAFEPATH" WAV COOPER Notification